BioSmart 5M-O User manual

BioSmart 5M-O/5M-E
Installation Guide
www.biosmart-tech.com

1 BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en
Contents
Contents.............................................................................................................................................................1
Safety Instructions.............................................................................................................................................2
1. Overview ....................................................................................................................................................3
Specifications......................................................................................................................................3
Part names and functions...................................................................................................................5
Package contents................................................................................................................................5
Opening the case................................................................................................................................6
Circuit board.......................................................................................................................................7
Circuit board LEDs and jumpers .........................................................................................................7
Connector names and description .....................................................................................................7
2. Installation .................................................................................................................................................8
Cable types .........................................................................................................................................8
General installation notes ..................................................................................................................8
Mounting on wall ...............................................................................................................................9
Power supply connection .................................................................................................................10
Network connection.........................................................................................................................11
Locks connection ..............................................................................................................................11
Exit buttons and door sensors connection.......................................................................................12
Wiegand output connection.............................................................................................................13

2 BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en
Safety Instructions
Safety instructions must be followed in addition to International Standards (ISO/IEC)*, and other
safety regulations.
Caution
Caution indicates a hazard with a low level of risk which, if not avoided, could
result in minor or moderate injury.
Note
Note indicates an important remark, which should be taken into attention.
Caution
General requirements:
Read, follow and retain instructions –All safety and operating instructions
must be read and followed properly before putting the unit into operation.
Do not turn on the power supply until all installation procedures are
finished –this may lead to injury or equipment damage.
Do not disconnect or connect cables while unit is powered on –this may
lead to unit malfunction and software errors.
Do not expose unit to heat or fire –high temperature impact may lead to
case deformation and circuit board damage.
Make sure that all cables and screws are fastened properly - otherwise
case damage or circuit shortcut may happen.
Note
Additional requirements:
Use a clean, dry cloth to remove any dirt or dust from the unit.
*IEC 60204-1: Safety of machinery –Electrical equipment of machines. (Part 1: General requirements)

3 BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en
1. Overview
BioSmart 5M-O Controller is designed for identification of users by fingerprints and RFID cards. It
can also control a lock or a turnstile (from one side only).
BioSmart 5M-E is a modification of BioSmart 5M-O designed to operate at the below zero
temperatures (in Celsius). The controller is equipped with a capacitive fingerprint scanner that
improves the quality of biometric identification. The controller internal elements have special
protection against corrosion and condensate, making device suitable for outdoor application.
Fingerprint scanner is equipped with a heating circuit that ensures comfortable scanning even at
low temperatures down to -40 °С.
Controller is compatible with BioSmart Studio software version V5.7.0 and above.
Specifications
Parameters
5M-O
5M-E
Authentication types
Biometric or card
Card + biometric
Biometric or card
Card + biometric
Users
1000
1000
Fingerprint templates
4 500
4 500
Event log capacity
25 000
25 000
Match time (1:1000) in local mode, by
fingerprints
< 970 ms
< 970 ms
Verification time (1:1)
< 600 ms
< 600 ms
FAR (False Acceptance Rate)
10-4 -10-8
10-4 -10-8
FRR (False Rejection Rate), at FAR = 10-5**
1%
1%
Sensor technology
Optical
Capacitive
Image size
272 x 320
272 x 320
Resolution
500 dpi
500 dpi
Smart card reader
HID Prox/iClass/iClass SE
(125 kHz / 13.56 MHz)
Legic Advant (13.56 MHz)
EM Marin (125 kHz)
HID Prox/iClass/iClass SE
(125 kHz / 13.56 MHz)
Legic Advant (13.56 MHz)
EM Marin (125 kHz)
LED indication
Tri-color (blue, red, green)
Tri-color (blue, red, green)
Communication
Ethernet (100 BASE-T),
Ethernet (100 BASE-T),

4 BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en
ZFlex Relay Module support
None
None
WIEGAND I/O
Output, 26/32 bit
Output, 26/32 bit
Discrete inputs
1
1
Onboard lock control relay
12VDC, 1A
12VDC, 1A
Tamper detection
1 sensor –on case
opening
1 sensor –on case
opening
Power requirements
12VDC±15%, 0.5 A
12VDC±15%, 0.5 A
PoE (Power over Ethernet)
None
None
Operating temperature
0 … +50°C
-40 … +50°C
Housing type
Aluminum, wall mount
Aluminum, wall mount
Dimensions (H x W x D)
160 x 50 x 43 mm
160 x 50 x 43 mm
Weight
260 g
260 g
Warranty
5 years
5 years
Note: * - Each user can be provided with single card code

5 BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en
Part names and functions
Name
Description
LED indicator
Blue –waiting mode
Green –identification successful
Red –identification failed
RFID card reader
RFID card identification
Fingerprint scanner
Fingerprint identification
Package contents
Item
Number, pcs
BioSmart 5M Controller
1
Mounting kit (two 6х35 dowels, two
3.5х38 self-tapping screws)
1

6 BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en
Opening the case
1) Remove the back cover retaining screw;
2) Detach the case from the back cover to access the circuit board.

7 BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en
Circuit board
Circuit board LEDs and jumpers
Name
Type
Description
VL3
LED
Indicates if Relay 2 is powered on
IP RST
Jumper
IP settings reset
BOOT
Jumper
Boot mode
Connector names and description
№
Name
Description
Used for
1
GND
Power supply -ground
Power supply
2
+12V
+12VDC Power supply
Power supply
3
REL
Relay output
Fail-safe lock/ Fail-secure lock, turnstile
4
REL
Relay output
Fail-safe lock/ Fail-secure lock, turnstile
5
IN+
Discrete input «+»
Enter/exit buttons, door sensors
6
IN
Discrete input
Enter/exit buttons, door sensors
7
WG1
Wiegand output DATA1
External controller wiegand output
DATA1
8
WG0
Wiegand output DATA0
External controller wiegand output
DATA0
9
Ethernet
Ethernet connection
Local network connection

8 BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en
2. Installation
Cable types
№
Cable connection
Max. length
Type
1
Ethernet (IEEE 802.3)
100 m.
Four twisted pair cables of no lower than category five
with a wire size of no less than 0.2 mm2
2
Power source
50 m.
Duplex cable with a wire size of no less than 0.75 mm2(for
example, 3192Y)
3
Turnstile, lock
20 m.
Duplex cable with a wire size of no less than 0.75 mm2(for
example, 3192Y)
4
Exit buttons, sensors
10 m.
CQR-6 or RAMCRO-6 cable
5
Wiegand interface
60 m.
Four twisted pair cables of no lower than category five
with a wire size of no less than 0.2 mm2
General installation notes
Install the controller on vertical surface;
Cables must be installed in accordance with the operational code for electrical
installations;
Do not lay cables within 30 cm of sources of electromagnetic interference;
All cables must only intersect power cables at a right angle;
All cable extensions must be soldered.
Carefully check for mechanical damage on the surface of the controller circuit board and
case;
In order to avoid short circuits, the protected ends of cables used to connect the controller
must not exceed 5 mm.
Caution
BioSmart 5M-E should be protected from rain and water.

9 BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en
Mounting on wall
1. Decide where to install controller, using a mounting template.
2. Drill holes, according to a mounting template and insert dowels inside the holes.
3. Place back cover on wall and fix it with self-tapping screws.
4. Connect power supply, lock and buttons, if needed, according to p.2.4-2.8. Put cables
through cable input.
5. In order to protect controller from electrostatic discharge, connect an annular crimp in a top
left corner of PCB with a grounding device (see figure below).

10 BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en
6. Attach the case and fix the retaining screw.
Power supply connection
Use a DC 12 V power supply adaptor with a minimum of 0,500 mA, which has obtained the
approval of IEC/EN 60950-1;
See recommended cable type and maximum length of the cable in Cable types table.

11 BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en
Network connection
See recommended cable type in Cable types table;
The order of connections in the cable’s modular connector must correspond to the TIA/EIA-568-
B standard.
Locks connection
See recommended cable type in Cable types table;
Install a diode as it shown on figure, to protect controller relay from reverse current. Use 1N4007
diode (1000V,1A) or similar;
Use separate power supplies for lock and controller;

12 BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en
Caution
Turn on “Relay inversion” in BioSmart Studio v5, if connecting an
electromagnetic lock.
Exit buttons and door sensors connection
See recommended cable type in Cable types table;

13 BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en
Wiegand output connection
See recommended cable type in Cable types table;
This manual suits for next models
1
Table of contents
Other BioSmart IP Access Controllers manuals