BioSmart PV-WM User manual

BioSmart PV-WM
Installation Guide
www.biosmart-tech.com

1 PV-WM Installation Guide v1.2|10.2018|en
Contents
Contents.............................................................................................................................................................1
Safety Instructions.............................................................................................................................................2
1. Overview ....................................................................................................................................................3
Specifications......................................................................................................................................3
Part names and functions...................................................................................................................4
Package contents................................................................................................................................4
Opening the case................................................................................................................................4
Circuit board.......................................................................................................................................5
Circuit board LEDs and jumpers .........................................................................................................5
Connector names and description .....................................................................................................5
2. Installation .................................................................................................................................................6
Cable types .........................................................................................................................................6
General installation notes ..................................................................................................................6
Mounting on wall ...............................................................................................................................6
Power supply connection ...................................................................................................................7
UniPass connection ............................................................................................................................8

2 PV-WM Installation Guide v1.2|10.2018|en
Safety Instructions
Safety instructions must be followed in addition to International Standards (ISO/IEC)*, and other
safety regulations.
Caution
Caution indicates a hazard with a low level of risk which, if not avoided, could
result in minor or moderate injury.
Note
Note indicates an important remark, which should be taken into attention.
Caution
General requirements:
Read, follow and retain instructions –All safety and operating instructions
must be read and followed properly before putting the unit into operation.
Do not turn on the power supply until all installation procedures are
finished –this may lead to injury or equipment damage.
Do not disconnect or connect cables while unit is powered on –this may
lead to unit malfunction and software errors.
Do not expose unit to heat or fire –high temperature impact may lead to
case deformation and circuit board damage.
Make sure that all cables and screws are fastened properly - otherwise
case damage or circuit shortcut may happen.
Note
Additional requirements:
Use a clean, dry cloth to remove any dirt or dust from the unit.
*IEC 60204-1: Safety of machinery –Electrical equipment of machines. (Part 1: General requirements)

3 PV-WM Installation Guide v1.2|10.2018|en
1. Overview
The BioSmart PV-WM Reader is a wall-mounted device, designed to capture a palm-vein template
or RFID card code and send it to BioSmart UniPass controller. Reader is not suited for stand-alone
application.
Specifications
Scanner type
Infrared
Scanning range
40-60 mm
Integrated RFID card reader
EM-Marine, HID, Legic, Mifare,
Card scanning range, mm
Up to 50 mm
Communication interface
Ethernet (IEEE 802.3,100BASE-T)
Case opening sensor
Yes
Power supply
12VDC±15%, 0,4 A, PoE
IEEE802.3af class 3
Operating temperature
-40 to +50 °C
Design
Laid-on plastic
Installation
Wall mount
Dimensions (H x W x D)
175 х 150 х 140 mm
Weight
Net: 650 g; gross: 675 g
Warranty
5 years

4 PV-WM Installation Guide v1.2|10.2018|en
Part names and functions
Name
Description
LED indicator
Blue –waiting mode
Green –identification successful
Red –identification failed
RFID card reader
RFID card identification
Palm vein scanner
Palm vein identification
Mounting holes
Suited for fixing screws
Cable inputs
Detachable panels, suited for cable inputs
Package contents
Item
Number, pcs
BioSmart PV-WM Reader
1
Mounting kit (four 6х35 dowels, four
3.5х38 self-tapping screws)
1
Opening the case
1) Remove two mounting screws on bottom and detach the steel plate;
2) Remove four mounting screws on back cover;
2) Detach the cover from the front part of the case to access the circuit board.

5 PV-WM Installation Guide v1.2|10.2018|en
Circuit board
Circuit board LEDs and jumpers
Name
Type
Description
VL26
LED
Indicates if board is powered up
VL27
LED
Indicates if PoE supply is on
IP RST
Jumper
IP settings reset
BOOT
Jumper
Boot mode
Connector names and description
№
Name
Description
Used for
1
GND
Power supply -ground
Power supply
2
+12V
+12VDC Power supply
Power supply
3
Ethernet
Ethernet interface connection
UniPass controller connection, PoE supply

6 PV-WM Installation Guide v1.2|10.2018|en
2. Installation
Cable types
№
Cable connection
Max. length
Type
1
Ethernet (IEEE 802.3)
100 m.
Four twisted pair cables of no lower than category five
with a wire size of no less than 0.2 mm2
2
Power source
50 m.
Duplex cable with a wire size of no less than 0.75 mm2(for
example, 3192Y)
General installation notes
Install the reader on vertical surface;
Cables must be installed in accordance with the operational code for electrical
installations;
Do not lay cables within 30 cm of sources of electromagnetic interference;
All cables must only intersect power cables at a right angle;
All cable extensions must be soldered.
Carefully check for mechanical damage on the surface of the reader circuit board and case;
In order to avoid short circuits, the protected ends of cables used to connect the reader
must not exceed 5 mm.
Mounting on wall
1. Decide where to install reader, using a mounting template.
2. Drill holes, according to a mounting template and insert dowels inside the holes.
3. Place metal plate on wall and fix it with self-tapping screws.
4. Put cables through back cover cable input.
5. Attach the cover to reader and fix it with four mounting screws.
6. Connect cables according to p.2.4-2.5.
7. Attach reader to the plate and fix the retaining screws.

7 PV-WM Installation Guide v1.2|10.2018|en
Power supply connection
Use a DC 12 V power supply adaptor with a minimum of 1,000 mA, which has obtained the
approval of IEC/EN 60950-1;
See recommended cable type and maximum length of the cable in Cable types table;
Power supply can also be provided via PoE from UniPass (see 2.5);

8 PV-WM Installation Guide v1.2|10.2018|en
UniPass connection
UniPass Ethernet connection ports are equipped with PoE sources;
See recommended cable type in Cable types table;
The order of connections in the cable’s modular connector must correspond to the TIA/EIA-568-
B standard.
Table of contents
Other BioSmart IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

Schlage
Schlage Panel Interface Module RS485 Installation & operating instructions

Inokey system
Inokey system BT 512 user manual

TH COMMUNICATIONS
TH COMMUNICATIONS MZ11D7 quick start guide

IDTECK
IDTECK iTDC Troubleshooting

SCHEIDT & BACHMANN
SCHEIDT & BACHMANN entervo.lane Device manual

Alarm Lock
Alarm Lock PDL3000 series Programming instructions