Installing the Battery
nsure laser on/off switch (A) is in the full off position by moving laser button to "O" position.
Remove the battery compartment cover (H). Insert 2 fresh 1.5 volt AA alkaline batteries
making sure to match (+) and (-) terminals correctly. Replace battery compartment cover.
WARNING: Batteries can explode, or leak, and can cause injury or fire. To reduce this
risk:
• Carefully follow all instructions and warnings on the battery label and package. • Always
insert batteries correctly with regard to polarity (+ and -), marked on the battery and the
equipment. • Do not short battery terminals. • Do not charge batteries. • Do not mix old
and new batteries. Replace all of them at the same time with new batteries of the same
brand and type. • Remove dead batteries immediately and dispose of per local codes. •
Do not dispose of batteries in fire. • Keep batteries out of reach of children. • Remove
batteries if the device will not be used for several months.
“Transporting batteries can possibly cause fires if the battery terminals inadvertently come
in contact with conductive materials such as keys, coins, hand tools and the like. The US
Department of Transportation Hazardous Material Regulations (HMR) actually prohibit
transporting batteries in commerce or on airplanes (i.e. packed in suitcases and carryon
luggage) UNL SS they are properly protected from short circuits. So when transporting
individual batteries, make sure that the battery terminals are protected and well insulated
from materials that could contact them and cause a short circuit.”
L W BATTERY INDICAT R
A battery energy level indicator is displayed in the lower left hand corner of
the display screen.
perating Instructions
NOTE: Detecting elements for wood and metal studs and AC Wires are
located in the lower part of the unit.
STUD DETECTI N
For stud detection through up to 3/4 inch (19mm) thick drywall.
1). Hold unit straight up and down and place flat against wall as shown in Figure 1.
2). Press in and hold the detector on/off button (B). LCD screen (D) will light and detector will
run initialization process.
3). R ADY message will appear on LCD screen and the unit will beep once to indicate it is
calibrated and ready for detection.
4). Slide unit slowly, Figure 2, horizontally across surface of wall without lifting or tilting. When
the STUD FOUND message appears on the LCD screen, slow down and keep sliding until
DG message appears and beep sounds as shown in Figure 3. This is the stud edge. Mark
this spot (at arrow on lower part of unit).
5). Keep moving past mark until DG and STUD FOUND disappear.
6). Continue holding detector button and reverse direction.
7). Find and mark other stud edge, following step 4).
8). Center of the stud is between marks.
AC WIRE SENSING
Test on a known “live” AC wire before each use. For AC Detection up to 1-1/2 inches (38mm)
from the surface. The sensor detects AC voltage and will identify only live wires. AC voltage
detection feature works continuously when detecting studs. It assists in identifying when the
sensor is near live AC wiring and detector button (B) is depressed. Once AC voltage has
been detected AC wire indicator L D (C) will light.
If the unit is calibrated close to AC wire, it may decrease AC wiring sensor sensitivity. Static
charge may spread detection 12 inches (30.4cm) on both sides of wire.
WARNING: Occasionally, pipes and electrical wiring may not be detected by this product.
Observe caution when cutting or drilling into areas that may contain concealed pipes or
wiring. The sensor will not detect live wires inside metal pipe or metal conduit, behind
metallic wall covering, or behind some plywood or other dense materials.
Use caution if area has plywood, thick wood backing behind drywall, or thicker than normal
walls.
WARNING: Always turn off the power when working near electrical wires, electric
shock may result.
AUT LEVELING LASER LINES
Operation of aser: Place unit flat against wall as shown in Figure 1. Move laser on/off
button (A) to "I" position to actuate the auto leveling horizontal laser lines.
HANGING N DRYWALL SURFACES NLY
Hands Free Operation of aser: To hang the unit on a wall, remove the orange protective
cap from the drywall pin (F) and store it on the cone as shown in Figure 4. Push pin into
drywall (Figure 5). When pressing pin into drywall, make sure it is straight and seated firmly.
Hang the laser on the cone as shown in Figure 6 and check to make sure that the unit is
secure on the wall. Figure 7 illustrates a typical application for the laser when it is wall
mounted.
CAUTI N: Pin is sharp and should be handled with care. The drywall pin should always be
pushed in by hand and never driven by a hammer. Replace protective cap after each use.
NOTE: The pin is only for use on drywall NOT other surfaces including plaster.
HANGING N THER SURFACES
Hands Free Operation of aser: For surfaces other than drywall, the (key hole) hanging
cone ( ) can be used with a standard nail or screw in a predrilled hole. To use the keyhole
hanging cone, place it over a nail or screw on a vertical surface with the narrow portion of the
opening pointing upward. Push the laser onto the hanging cone until it snaps into place. To
remove the laser, lift it slightly and pull it straight off. The unit can also be used with the
hanging cone attached to the back and then hanging the unit on the nail or screw. Make sure
it is straight and seated firmly on the cone and that the unit is secure on the wall.
DANGER: Laser Radiation, avoid direct eye exposure.
Helpful Hints
• If the laser light becomes dim or is no longer visible when the switch is in the on position
check or change the battery.
• The laser lines are only level on the wall against which the unit is held or hung. The short
line visible on any adjacent wall is not level.
• The laser unit is a wall use tool only and only generates level lines when held against a
vertical surface.
• The laser unit is equipped with a pendulum lock that stops pendulum motion when the laser
on/off switch is moved to the off position.
• If the laser on/off switch is pushed part way to the on position, the laser lines may be on
while the pendulum lock is still engaged.
• Hold stud sensor straight up and down.
For your convenience and safety, the following labels are on your laser. Helpful Hints (Con’t).
• Because studs are normally spaced 16 inches or 24 inches apart and are 1-1/2 inches wide,
beware of anything closer together or of a different width. Doors and windows are
constructed with studs and headers which are closer together.
• When using unit over a stucco wall, place a piece of cardboard over the surface to help
provide a smooth motion across the wall.
•Avoid materials which have inconsistent density such as:
• Carpeting and padding
• Ceramic floor tile
• Wallpaper containing metallic foils or fibers. Generally, surfaces covered with regular
wallpaper or fabric will scan with no difference in function.
• Walls that are freshly painted and are still damp.
• xcessively thick plaster and lath.
Storage
Always store this product indoors and in its protective case.
Maintenance
Use only mild soap and damp cloth to clean the tool. Never let any liquid get inside the tool;
never immerse any part of the tool into a liquid.
IMPORTANT: To assure product SAF TY and R LIABILITY, repairs, maintenance and
adjustment (other than those listed in this manual) should be performed by authorized service
centers or other qualified service organizations, always using identical replacement parts.
Accessories
Recommended accessories for use with your tool are available from your local dealer or
authorized service center. If you need assistance regarding accessories, please call:
1-800-544-6986.
WARNING: The use of any accessory not recommended for use with this tool could be
hazardous.
SERVICE INF RMATI N
All Black & Decker Service Centers are staffed with trained personnel to provide customers
with efficient and reliable power tool service. Whether you need technical advice, repair, or
genuine factory replacement parts, contact the Black & Decker location nearest you. To find
your local service location, refer to the yellow page directory under "Tools— lectric" or call: 1-
800-544-6986 or visit www.blackanddecker.com
FULL TW -YEAR H ME USE WARRANTY
Black & Decker (U.S.) Inc. warrants this product for two years against any defects in material
or workmanship. The defective product will be replaced or repaired at no charge in either of
two ways.
The first, which will result in exchanges only, is to return the product to the retailer from whom it
was purchased (provided that the store is a participating retailer). Returns should be made
within the time period of the retailerʼs policy for exchanges (usually 30 to 90 days after the
sale). Proof of purchase may be required. Please check with the retailer for their specific return
policy regarding returns that are beyond the time set for exchanges.
The second option is to take or send the product (prepaid) to a Black & Decker owned or
authorized Service Center for repair or replacement at our option. Proof of purchase may be
required.Black & Decker owned and authorized Service Centers are listed under
"Tools- lectric" in the yellow pages of the phone directory.
This warranty does not apply to accessories. This warranty gives you specific legal rights and
you may have other rights which vary from state to state or province to province. Should you
have any questions, contact the manager of your nearest Black & Decker Service Center. This
product is not intended for commercial use.
FREE WARNING LABEL REPLACEMENT: If your warning labels become illegible or are
missing, call 1-800-544-6986 for a free replacement.
ATIN AMERICA: This warranty does not apply to products sold in Latin America. For
products sold in Latin America, check country specific warranty information contained in the
packaging, call the local company or see the website for warranty information.
T CHNICAL SP CIFICATIONS OF LAS R L V L:
Laser Diode Wavelength: 650 ± 5 nm (red color)
Laser Class: Class IIIa
Working Range: Up to 20 feet (depends on light conditions)
Leveling Accuracy: ±1/8 inch (3 mm) @ 10 feet (3 m)
Auto Leveling Range: ±4.5°
Auto Leveling Lines Settling Time: <5 sec
Batteries: 2 AA Alkaline (included)
Voltage: 3 Volt
Operating Temperature: 50°F (10°C)- 104° F (40°C)