CHAPTER 3: INSTALLATION
STEP 2: INSTALLING THE MODULE
The module can be DIN rail mounted using the DIN rail mounting clip on the back of the module. The bottom tab of the DIN rail clip
is spring loaded and is used to install and remove the module from the DIN rail.
To install the module to the DIN rail, angle the module so the bottom edge of the spring loaded clip is inserted on the lower edge
of the DIN rail. While pushing the module up, angle the module ush to the DIN rail and insert in the upper edge of the DIN rail clip
around upper edge of the DIN rail.
To remove the module from the DIN rail, hold the module rmly while lifting the module up. Angle the top of the module away
from the DIN rail, disengaging the module from the upper edge of the DIN rail.
STEP 3: APPLY DC POWER
This module is intended for installation in restricted access areas. (“Les matériels sont destinés à être installés dans des
EMPLACEMENTS À ACCÈS RESTREINT”). A restricted access area can be accessed only through the use of a special key,
or other means of security.
The over current protection for connection with centralized DC shall be provided in the building installation, and shall be a UL listed
circuit breaker rated 20 Amps, and installed per the National Electrical Code, ANSI/NFPA-70.
The LIE402A requires +50 to +57 VDC inclusive of tolerances (4.46 A @ 56 VDC maximum rated power).
Be sure to provide appropriate overloading protection on the DC power source outlets used.
TOP VIEW WITH DC POWER CONNECTOR
WARNING: OnlyaDC power source that complies with
safety extra low voltage (SELV) requirements can be
connected to the DC-input power supply.
WARNING REGARDING EARTHING GROUND:
o
o
o
o
This equipment shall be connected to the DC supply
system earthing electrode conductor or to a bonding
jumper from an earthing terminal bar or bus to which the
DC supply system earthing electrode is connected.
This equipment shall be located in the same immediate
area (such as adjacent cabinets) as any other equipment
that has a connection between the earthed conductor of
the same DC supply circuit and the earthing conductor,
and also the point of earthing of the DC system. The DC
system shall not be earthed elsewhere.
The DC supply source is to be located within the same
premises as this equipment.
There shall be no switching or disconnecting devices in
the earthed circuit conductor between the DC source and
the earthing electrode conductor.
Locate the DC circuit breaker of the external power source, and switch the circuit breaker to the OFF position.
Prepare a power cable using a three-conductor insulated wire (not supplied) with 12 AWG to 14 AWG thickness. Cut the power cable
to the length required.