Black BLK-PTZJOY3 User manual

INSTRUCTION MANUAL
BLK-PTZJOY3 3-Axis Joystick Controller
BLK-PTZJOY3

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN
OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR
OTHER OPENINGS ON THE EQUIPMENT.
The lightning flash with arrowhead symbol, within
an equilateral triangle, is intended
To alert the user to the presence of un-insulated
"dangerous voltage" within the
product's enclosure that may be of sufficient
magnitude to constitute a risk of electric
shock to persons.
The exclamation point within an equilateral triangle
is intended to alert the user to
The presence of important operating and
maintenance (servicing) instruction in
the literature accompanying the product
WARNING
SYSTEM CONTROLLER
-2 -
FCC COMPLIANCE STATEMENT
FCC INFORMATION: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A
CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO
PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS
OPERATED IN A COMMERCIAL ENVIRONMENT. THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE
RADIO FREQUENCY ENERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION
MANUAL, MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS. OPERATION OF THIS
EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE
USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE.
CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR
COMPLIANCE COULD VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT.
CE COMPLIANCE STATEMENT
WARNING
THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO
INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES.

CONTENTS
General Descriptions, Features ...……..………………………..…. 5
Installation ...................……………….....………………….…..……. 6
Part names & Functions …………………...………….…….……..…. 7
Display LCD window ……………………....………………….......….. 8
PTZ Control ....................…..….……………....…...……....….…… 9
PTZ Configuration ..........…..….……………....…...……....….…… 11
Hidden command …………………………………....………….…….. 12
Specifications & Dimensions ……...………....………………………. 13
SYSTEM CONTROLLER
-3 -

General Descriptions
The BLK-PTZJOY3 is a pan/tilt controller that allows operators
to perform the following functions :
• Controls camera functions such as pan, tilt, zoom, and focus.
• Sets and calls camera preset positions
• Activates pre-programmed group presets, tour and group sequences.
The LCD is used to display current status as well as to provide a menu system for setting
operational parameters.
Controller is designed for desktop operation; interface connectors are located in the Junctions box
outer of the unit.
Features
• Recalls up to 255 cameras from one keyboard.
• Multiple protocol supported in each channel (Pelco D, DRX-502)
• Preset position control.
• Variable manual control speed from 1°/sec to 90°/sec
• Maximum speeds are proportional to zoom ratio.
• Recalls programmed guard tours from each dome camera.
• Recalls Auto-Swing from selected dome camera.
• Built-in Graphic LCD monitor with blue screen.
• Programmable user preferences. (preset, tour, group, etc.).
• User password support.
• Supported DVR protocol (Need to be modified)
• Easy upload programmed data via serial communication port of computer.
• Slave Keyboard support.
SYSTEM CONTROLLER
-4 -

SYSTEM CONTROLLER
Junction Box
RJ-11 Cable
⑥
⑤
④
③
②
①
⑦
Slave Port Master Port
< Configuration of Junction Box >
① RS-485 (+) : Connect to PTZ (+)
② RS-485 (-) : Connect to PTZ(-)
③ Power input ((DC12V (-)) : Not used.
④Not used
⑤Not used
⑥ Power input :DC12V (+)
⑦ RJ-11 Modular Jack : Connect to Controller
-5 -
UNPACKING
Unpack the equipment and make sure all listed items are included in the box.
Keyboard controller ………………………………………………….……… 1
Junction box ………………………………………………………….………. 2
3m 6p cable RJ-11………………………………………………….………… 2
Instruction manual ….………….…………………………………………….. 1
1. CONNECTIONS
There are two connectors on the controller. These connectors are RJ connector for Master and
Slave control.
1.1 Open the junction box cover and connect the 12VDC power to the junction box number 3 and 6.
(DC 12V, 500mA, Power adaptor is not included in the system box).
1.2 Connect 6-pin multi-wired cable between junction-box and keyboard.
1.3 Connect PTZ communication wires (RS-485, 2-wires) to the junction box number of 1 and 2.
1.4 Turn on the power, then you will get into the starting mode.
Installation

Parts name & functions
1. LCD Display : Displays numeric input, system status, function status, general status, etc.
2. Shows the communication status (Master / Slave)
3. Mon : Select output channel of Matrix Switcher. (TBD)
4. Quad : Select channel of Quad.(TBD)
5. Mux : Select channel of Mux.(TBD)
6. 0~9 :Numeric keypad :
7. CLR : Cancel key .
8. CAM : Select address of Camera, Mux, Quad and Matrix Switcher.
9. SHIFT : Key for special function (Customize).
10. SET : Connected equipment setting and system information setting.
11.12. IRIS Open ,12. IRIS Close :Camera Iris control.
13. 20. Near / Far Focus: Camera focus control.
14. 21. Wide / Tele Zoom : Camera zoom control.
15. AUX On : AUX ON of Receiver unit.
16. AUX Off : AUX Off of Receiver unit.
17. System Hold : Used for system hold
18. Menu : Used for Camera (Pan/Tilt) Menu adjustment.
19. F1 ~ F5 : Function Keys (Preset, Group, Tour, Pattern, Scan).
22. Telemetry Joystick – Allows precise control of Pan/Tilt/Zoom & Moving to menu
SYSTEM CONTROLLER
-6 -
1
2
3 4 5
6
7
8 9 10 11 12 13 14
15 16 18
19 20 21
22
17

SYSTEM CONTROLLER
-7 -
12
Drawing of Console Desk
BLK-PTZJOY3 is designed to use on the console desk.
When you install the keyboard on the console desk, please make holes as below drawing.
Unit : mm
1. Slave Port : Connect to Slave Communication Port.
2. Master Port : Connect to Master Communication Port
Parts name & functions

SYSTEM CONTROLLER
- 8 -
Select and control the camera
1CAM
Camera Address Press CAM button
1) How to select Address Number 1 camera
with Pelco-D protocol?
2CAM
2) How to select Address Number 2 camera with
DRX-502 protocol?
Camera Address Press CAM button
PROTOCOL
PTZ ADDR
MON CHAN
PRE GRO TOUR SCAN PATT FOCUS ZOOM
PELCO-D : 2400 BPS
001
001
PROTOCOL
PTZ ADDR
MON CHAN
PRE GRO TOUR SCAN PATT FOCUS ZOOM
PELCO-D : 2400 BPS
001
001
PROTOCOL
PTZ ADDR
MON CHAN
PRE GRO TOUR SWING AUTO FOCUS ZOOM
DRX502A : 9600 BPS
002
001
Display LCD window
(1) Initial display
1. C-001 : Shows the current camera No. (Address).
2. M-001 : Displays output channel of Matrix Switcher. (TBD)
3. DRX5 : Shows the selected camera protocol.
4. Func : Displays entered Key.
Accessing to the camera menu:
This function is only for the speed dome camera
Move to next item
by using joystick
Move to next item
by using joystick

- 9 -
SYSTEM CONTROLLER
• Control and Setting of PTZ Camera Functions
1. Setting to the camera functions
1MENU
Camera Address Press MENU button
① Camera Setting Menu
2.Accessing to the camera functions
①Preset
1F1
Preset number PRE KEY
Press the preset number and PRE key (F1) on the keyboard.
The Monitor will show you the function name and you are
operating now.
①Group
1F2
Group number GRO KEY
<Pressing keypad “1” and holding the “MENU” key
for approximately 2 seconds>
** Note: Dome camera menu is different according to camera manufacturers.
Please be noted dome camera instruction manual in detail menu explanation.
Each menu page is provided with a highlighted cursor which can be moved around the page using the Up,
Down, Left and Right cursor keys with Joystick.
Press the preset number and GRO key (F2) on the keyboard.
The Monitor will show you the function name and you are
operating now.
※To using Preset, Group, Tour, Scan, Auto pan, Focus, Zoom functions of keyboard, user should store
these functions on the camera Menu in advance.
This unit supports DRX-502 and Pelco D protocol.

-10 -
SYSTEM CONTROLLER
• System Controller (Keyboard) Functions setting
1. System functions setting
1SET
①
②
You will be prompted for a password if one has previously been set (factory default is “0000”.)
③ Set the information as LCD show you by using joystick.
④ PTZ Configuration is as below.
System
Setting
‘1’+ SET(-)
(2 seconds)
PASSWORD
Equipment
number Equipment
number
PTZ
CAMERA
QUAD
MATRIX
DVR
ETC.
PROTOCOL
DRX-502
PELCO-D
COMM SPEED
9600BPS
2400BPS
4800BPS
19200BPS
38400BPS
JOYSTICK
PROP.
ON-OFF
EXIT
Save &
Exit
Exit only
PTZ-K1
PTZ Camera (Rx) and Protocol setting.
<Pressing keypad “1” and holding the “SET” key
for approximately 2 seconds>

PROTOCOL PELCO -D : 2400 BPS
PTZ ADDR 001
MON CHAN 001
PRE GRO TOUR SCAN PATT FOCUS ZOOM
SYSTEM CONTROLLER
-11 -
PASSWORD?
1. NO. 001
2. TYPE PTZ
3. PROTOCOL DRX-502
4. COMM SPEED 2400 BPS
NO. : Select camera address to be changed.
TYPE : Select camera type.
PROTOCOL : Protocol select.
COMM SPEED :Select communication speed
** DRX-502 : 9600 bps
** Pelco D : 2400 bps
5. JOYSTICK PROP
6. EXIT
JOYSITCK : Select the way of Joystick control.
PROP : Proportional speed control.
ON-OFF : Fixed speed control.
EXIT
Accessing the system setup menu
Pressing keypad 1 and then holding the SET key for
approximately 2 seconds.
It provides access to the system setup menu system.
Note: You will be prompted for a password if one has
previously been set
(factory default is “0000”)

System
setting
‘2’+ Set(-)
(2 seconds)
PASSWORD
PASSWORD
Setting OP Mode Sleep Time
Slave
Master Factory set
Start
Cancel
Joystick Version OEM Logo
SYSTEM CONTROLLER
-12 -
2SET
①
This hidden menu performs to operator to change PASSWORD and others.
2.Hidden command
<Pressing keypad “2” and holding the “SET” key
for approximately 2 seconds>
②
You will be prompted for a password if one has previously been set (factory default is “0000”.)
③ Set the information as LCD show you by using joystick.
④ PTZ Configuration is as below.
Exit
Save &
Exit
Exit Only
Buzzer
ON
OFF

(376mm (W) x 112mm (H) x 145mm (D), 1.3Kg)
Dimensions
&
Weight
10% - 70% non condensingHumidity
Operating Temperature
Graphic display 240 x 64 dots. Display 4-line x 30-character
alphanumeric LCD display with blue backlight.
LCD Display
Max.150 mAPower Consumption
12 VDC ±2VInput Voltage
Three-axis, vector solving, with twisting, return-to-center head
Joystick
Numeric keyp ad and camera function ke ys.
PC Keyboard button
Keyboard Keypad
RJ-11 6-pin modularConnector Type Data
Protocol: Multiple ( Wonwoo, etc. ) (Baud rate selectable)
Pan/Tilt operating distance: 4000 ft (1029m) on 24 AWG wire
DVR interface: RS-485
Pan/Tilt interface: RS-485
Keyboard Communication
BLK-PTZJOY3Model
SYSTEM CONTROLLER
Dimensions
-13 -
W
D
H
14.8” (W) x 4.41” (H) x 5.71” (D), 2.9 lbs
32°F to 113°F (0°C to 45°C)

Table of contents
Popular Controllers manuals by other brands

Pixsys
Pixsys ATR 621 series user manual

Tyco Security Products
Tyco Security Products DSC Neo Power Series manual

Maguire Products
Maguire Products Weigh Scale Blender WSB Operation & maintenance manual

ABB
ABB Relion 630 Series Comissioning Manual

Koei
Koei Unic Series Operation manual

3Ware
3Ware 9000 Series specification

oventrop
oventrop Aktor M technical information

delta-mobrey
delta-mobrey DMCU800 Installation, operation & maintenance instructions

Honeywell
Honeywell Excel 800 Installation and commissioning instructions

Belimo
Belimo PR QUICK MOUNT VISUAL INSTRUCTION MANUAL

Smallart
Smallart SM2008FFS Series manual

Honeywell
Honeywell UDC3300 product manual