Sensor speed controller
SGS E1/SGS E2.5
The sensor thyristor speed controller SGS E1/SGS E2.5 is designed for output power of ventilation units
and domestic fans as well as their turning on and off. The speed controller is equipped with a sensitive
sensor panel made of hardened glass, with the button and two buttons for speed control from
minimum ( ) to maximum value ( ).
WARNING! Make sure that the speed controller is not damaged. Do not operate a damaged speed controller! Do not install the speed controller
on an uneven surface! Do not apply excessive forces to avoid the product deformation.
Mounting sequence of the sensor speed controller:
Unfasten gently the front panel latches of the speed controller.
Remove the front panel.
Route the cable in the wall to the panel mounting place.
Attach the back panel to the wall or in the mounting box through the mounting holes.
Install the front panel on the latches.
86
62
4
52
86 31
21
R1.5
11
58
Sensor speed controller mounting
OVERALL AND CONNECTING DIMENSIONS
WIRING DIAGRAM
TECHNICAL DATA
MOUNTING
SGS E1 SGS E2.5
Power supply voltage [V] 230/50-60
Maximum load current [A] 1 2.5
Cable cross section [mm²] from 0.35 up to 1 from 0.75 up to 1
Temperature range [°C] from -10 up to +45
Humidity range [%] 5-80 (no condensation)
Service life 100 000 switching operations
Ingress Protection Rating IP30
Weight [g] 138
WARNING! Disconnect the speed controller from power supply prior to any maintenance operations.
All work related to mounting, amendments, modification and maintenance may only be carried out by qualified personnel with
work permit for electric operations.