blossom-ic Magelan ZR-3997 User manual

MAGELAN
Circulation Pump
Controller
Assembly instructions
intelligent | economic | cost-saving | individual | exible | user-friendly | smart | protable | innovative
1.1
Version
blossom-ic radio and app-controlled Circulation Pump Controller with
contact Sensor. For controlling the circulation pump. As soon as the
motion Sensors on the selected appliances detect people, the controller
activates the circulation pump for the set running time. Furthermore, it
is possible to set a certain temperature of the return pipe. As soon as the
temperature falls below this temperature, the controller also activates
the circulation pump. This process is repeated when the temperature is
subsequently recorded. In addition, the controller oers a drinking water
hygiene function against legionella. In conjunction with Gateway GT-100.
Brief description:

blossom-ic GmbH & Co. KG |Intelligent Controls
2
Contents...
Connection of the Gateway GT-100 ............3
Registration of Circulation Pump Controller ...3
Connection diagram............................... 4
Control via blossomic app ........................ 5
Technical data...................................... 7
Safety instructions ............................... 7
Declaration of conformity ........................ 7
Warning notice .................................... 7
Attention........................................... 7
Intended Use....................................... 7

Assembly instructions: Magelan Circulation Pump Controller 3
Connection of the Gateway GT-100
Screw on the antenna Connect power supply unit Connect the network cable
Both diodes light up
permanently: Gateway active
Check status
Green diode lights up constantly: Internet
connection is establishing.
Green diode lights up constantly: Internet
connection is successfully established
1. 2. 3.
4. 5. Hint:
Functionality in the home safe area. Internet
connection is used for convenient setting
and control via smartphone.
The system functionality is guaranteed even
if no Internet connection is available.
Registration of Circulation Pump
Controller
Connect the Circulation pumps
controller as described in the
connection diagram
Mount the contact Sensor at a
suitable point in the return pipe
Press the „Register“ button on
the gateway
1. 2. 3.
Contact
Sensor
Circulation
pump
Contact sensor
Return Pipe

blossom-ic GmbH & Co. KG |Intelligent Controls
4
Press the „Register“ button on
the Circulation Pump Controller
for 3 seconds
4.
LED on controller starts flashing,
controller registers
5.
LED on the controller lights up
continuously => The registration
was successful
6.
Note:
If the LED on the Circulation Pump Controller goes o => The registration has failed
(Please repeat previous steps)
Connection diagram
Contact
Sensor
Circulation
pump

Assembly instructions: Magelan Circulation Pump Controller 5
m
1
2
3
4
5
6
Circulation system
As soon as the Circulation Pump
Controller is registered on the
gateway, the symbol “Circulation
system” appears in the app.
Manual mode
Naming the Circulation
Pump Controller
Status display
Setting the running time
The circulation pump is active for
the set running time (between 1 and
5 minutes). This enables hot water
to be available at the hot water
extraction points.
Save changes
All changes must always be con-
firmed
Setting the interval
The circulation pump is deactivated
for the duration of the set interval.
Aer this time, the controller acti-
vates the circulation pump for the
set running time. The process is then
repeated.
System overview
Device control
Radiator Underfloor Boiler
Leakage
system
Security
system
PI-SensorBlinds Socket
Help
PDF Manuals
system Fan-Coil
5 min
Interval 30 min
Albrecht
Flat 3 / ID: 12 ID: 12
Submit
1
4
3
2
5
6
Control via blossomic app

blossom-ic GmbH & Co. KG |Intelligent Controls
6
1
2
3
4
5
6
7
1
2
3
4
5
7
6
Automatic mode
Naming the Circulation
Pump Controller
Last circulation
Time of the last circulation run.
(Note: Aer this circulation run,
Sensor detection is disabled for 30
minutes to avoid unnecessary circu-
lation runs)
Save changes
All changes must always be con-
firmed
Selected Sensors
In the overview you can see the
Sensors that have been selected for
Sensor acquisition.
Detection
Selection of devices (thermostat,
motion Sensor) for detection.
Setting the running time
The circulation pump is active for
the set running time (between 1 and
5 minutes). This enables hot water to
be available at the hot water tapping
points.
Temperature Mode
Naming the Circulation
Pump Controller
Status display
Save changes
All changes must always be con-
firmed
Current return tempera-
ture
This field shows how high the cur-
rent return temperature is.
Switch-on temperature
If the return temperature falls below
this value, the controller switches on
the circulation pump.
Switch-off temperature
If the return temperature reaches
the set switch-o temperature, the
controller switches o the circula-
tion pump.
When the return temperature falls
below the activation temperature
again, the process is repeated.
Flat 3 / ID: 12
Bedroom ID: 1
Living room ID: 8
Kitchen ID: 13
Online
Online
Online
ID: 12
3 min
Submit
7
1
3
2
4
5
6
Switch-on Temperature 30 °C
60 °C
Albrecht
Flat 3 / ID: 12 ID: 12
Current return Temperature 39,1 °C
Submit
1
3
2
4
5
6
7

Assembly instructions: Magelan Circulation Pump Controller 7
Attention! Important Note:
Installation and assembly of electrical devices may only be carried out by a qualified electrician. Failure to observe the assembly and installa-
tion instructions can result in fire or other dangers.
Safety instructions
Hereby blossom-ic GmbH & Co. KG hereby declares that the following product: Magelan Circulation Pump Controller ZR-3997 is in conformity
with the essential requirements and other relevant provisions of Directive 2014/53/EU. The complete declaration of conformity can be found
at the following address: www.blossomic.de/downloads Declaration of conformity.
Declaration of conformity
The Circulation Pump Controller is not suitable for children and must not be used as a toy. Store and dispose of packaging materials in a child-
proof manner. Do not disassemble the Circulation Pump Controller, as it does not contain any user-serviceable parts. If defects occur, please
return the Circulation Pump Controller to the dealer. This appliance may be used by children over 8 years of age and by persons with reduced
physical, Sensory or mental abilities or lack of experience and knowledge, provided they have been supervised or instructed in the safe use
of the appliance and understand the dangers involved. Children must not play with the device. Cleaning and user maintenance must not be
performed by children without supervision.
Warning notice
Please observe the drinking water regulations with regard to legionella protection!
Attention
The Circulation Pump Controller is only suitable for controlling circulation pumps.
Intended Use
Technical data
Technical data - Magelan Circulation Pump Controller
Ambient temperature
Mains voltage
Dimension
Wireless frequency
Protection class
RF-Test
CE
RoHs
Type of antenna
Probe length
0 ~ 50°C
230V AC / 50/60Hz
L86 x W86 x H44 (mm)
2.4GHz, ISM band, 16 channels
IP 30
RED 2014/53/EU
Available
Available
PCB antenna
2 meter

blossom-ic GmbH & Co. KG
Oberer Buxheimer Weg 60, 87700 Memmingen, Germany
P: +49 8331-756 965 80 E: [email protected]
W: www.blossomic.de