3
Specifications
Model Numbers Covered in this Specification
E580-8 / 8E - Electric Bratt Pan, Manual / Electric Tilt - 900 mm wide (80 ltr).
E580-12 / 12E - Electric Bratt Pan, Manual / Electric Tilt - 1200 mm wide (120 ltr).
General
E580-8/8E (80 ltr) Electric Bratt Pan.
A commercial heavy duty, electric Bratt Pan fitted with an 80 ltr capacity pan, of full stainless steel pan
construction, with 3 x 4 kW stainless steel sheathed elements clad to the pan base giving even heat
distribution. This appliance features an electric thermostat burner control and over temperature safety
cut-out.
Created for compact modular kitchens, it is fitted with manual (E580-8 model) or electrical (E580-8E
model) operated tilting mechanism with burner cut-out when the pan is tilted.
E580-12 / 12E (120 ltr) Electric Bratt Pan.
A commercial heavy duty, electric Bratt Pan fitted with an 120 ltr capacity pan, of full stainless steel pan
construction, with 3 x 5.66 kW stainless steel sheathed elements clad to the pan base giving even heat
distribution. This appliance features an electric thermostat burner control and over temperature safety
cut-out.
Created for compact modular kitchens, it is fitted with manual (E580-12 model) or electrical (E580-12E
model) operated tilting mechanism with burner cut-out when the pan is tilted.
Electrical Supply Requirements
E580-8 / 8E - 12 kW. 400-415V ac, 50 / 60 Hz, 3P+N+E, 12.0 kW @ 415V.
Phase loading; L1 = 16.4A.
L2 = 16.4A.
L3 = 16.4A.
E580-12 / 12E - 17 kW. 400-415V ac, 50 / 60 Hz, 3P+N+E, 17.0 kW @ 415V.
Phase loading; L1 = 23.2A.
L2 = 23.2A.
L3 = 23.2A.
Electrical Connection
When connecting a Blue Seal electric appliance to the main supply, ensure that the following is
carried out:-
• An isolating switch is fitted within 2 m of the appliance, but not on the appliance and in
such a position that the user does not have to reach across the cooking surface.
• Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS / NZS
3191 part 2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type.
• The branch supply line shall be individually overload protected to the correct current rating
and the supply chord shall be protected against any mechanical or thermal damage.
• A grommet is fitted around the wiring entry hole into the appliance.
• All wiring connections must be tight.
Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance
for the current drawn on that line.
WARNING:
THIS APPLIANCE MUST BE EARTHED.IFTHE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY ASUITABLY
QUALIFIED PERSON IN ORDER TO AVOID AHAZARD.