Business Conceptions OESTONIA Keemia 4 Tallinn 10616 T: +372 8840581 E-mail: in[email protected]
BLUE STERI BST –100 MINI
ULTRAVIOLET AIR & OBJECT PURIFICATION SYSTEMS
User Manual / Technical Instructions
Please read this manual before using the device and keep it for future reference. This manual is intended to be used as a reference project by individuals, professionals
and authorized users, to assist them in the safe installation, use, maintenance and repair of the units. No part of this publication may be copied or published via print,
photocopy, microfilm or otherwise without prior written consent of the manufacturer. This restriction also appliesto the corresponding drawings and diagrams. The information
given in this manual has been collected for the general convenience of our customers. Subject, at any time, to change or modification by the manufacturing company.
SAFETY INSTRUCTIONS
Read this manual carefully before using the device. Installation of the device must be carried out in
accordance with domestic safety rules. In case you have any doubt about the suitability of your electrical
supply/wall outlet, if it is properly grounded or protected by safety, call a qualified technician/electrician.
This device has been tested and certified for its safe operation. In any case, however, like any
electrical appliance, it should be used with caution. Make sure the device is turned off. Then unplug the
appliance before cleaning, assembling or disassembling the appliance.
This device only connects toa grounded socket at220-240V / 50Hz. Avoid touching ormoving parts
of the device. Never put your fingers or other objects in the air inlets and outlets. Children should be
supervised to ensure that they do not play with the appliance.
This device is not intended for use by persons (including children) with reduced physical, sensory or
mental capacity or by persons with a lack of experience or knowledge, unless supervised or instructed
in the use of the device by any person responsible for their safety.
Do not clean the appliance by splashing it or immersing it in water. Never plug the appliance into
the outlet using an extension cord/ballad. In the event that there is no socket available, it should be
installed by a qualified technician. Do not plug in or unplug the appliance with wet hands. Danger of
electric shock.A damaged power supply cable should only be replaced by a qualified technician toavoid
possible injury.
Do not use the device for purposes other than those for which it was designed. This device must
always be stored and moved to an upright position. Do not switch the appliance on or off by plugging in
and unplugging it. Use the ON / OFF button to turn the device on or off. The appliance must not be
placed in the bathroom or in damp places.
ENERGY SAVING AND USEFUL SAFETY TIPS
Do not cover or prevent air from entering and leaving the grilles.
Keep the filters clean. Under normal conditions, the filters need cleaning every 3-5 weeks.
Clean the filters with a vacuum cleaner. Never clean the filters with water.
Call our authorized partner for the annual check of the device.
INTENDED USE
NON FORESEEABLE USE
The device is used to control and deactivate viruses and air pollutants.
Provides certified effective disinfection to bacteria, fungi, allergens, volatile
and organic loads and has a photocatalytic dosage inside the reactor to
inactivate SARS-CoV-2.
It is designed for use in private and commercial buildings. The user must
comply with the operating parameters specified in these instructions.
Operate the appliance on flat, stable and dry surfaces, in a temperature
range between 0 °C and 50 °C and humidity below 70%.
The appliance must not be operated outdoors or in damp areas with a humidity of more than
70% or next to a humidifier next to heaters, fireplaces or appliances using gas.In environments
with temperature fluctuations, as this can lead to water condensation inside. The device is not
intended for drying items.
Do not place the appliance near other heat sources. It may cause deterioration of its plastics
and fire. Do not use the device near flammable gases or materials such as gasoline, solvents,
etc. Fire hazard. Do not place objects on the device. Always place the appliance in a dry place
and on a flat surface.
Business Conceptions OESTONIA Keemia 4 Tallinn 10616 T: +372 8840581 E-mail: [email protected]
DIAGRAM AND BASIC PARTS OF THE DEVICE
1
DEVICE FILTER
2
FILTRER COVER
3
FLOOR BASE
4
DEVICE POWER SUPPLY
5
GENERAL DEVICE SWITCH
6
AIR SUPPLY REGULATOR ANALOG
7
AIR OUTLET
8
WIRELESS CONTROL
9
LAMPS LIGHT INDICATION
10
AIR INLET
TECHNICAL CHARACTERISTICS
ΒST 100
CLEAN AIR DELIVERY RATE :
m3/h
70 / 100
VOLTAGE :
(V)
230
AMPERAGE :
(Α)
1,3 –2,9
ENERGY CONSUMPTION :
(W)
100 –110
MOTOR POWER :
(W)
18
DECIBEL :
Db(a)
30 –45
DIMENSIONS (W-D-H) :
mm
212 x 210 x 790
WEIGHT :
kg
5
FILTRATION
SILVER FILTER :
Fiber shield™
150 x 200 x 2 (mm)
CARBON FILTER :
CARBON
150 x 200 x 8 (mm)
IONIZATION NEGATIVE
ION/ POSITIVE IONS :
PLASMA (V)
Neg-11.000 / Pos+ 9.000 (V)
OZONE OUTPUT :
SILVER FILTER :
PPM
0,04
STERILIZATION
UVC LAMPS :
(W)
1 x 20 W
FREQUENCY :
Nm
254
CONTROL
ANALOG MOTOR REGULATOR :
██
WIRELESS CONTROL (on/off) :
██
WIFI REMOTE MANAGEMENT:
██
AIR QUALITY DIGITAL DETECTOR :
OPTION
AIR CARACITY PROCESS
SPACE COVERAGE
(Height 2,5m)
CLEAN AIR per m2/min :
m2/ min
40 m2/ 60 min
20 m2/ 30 min
10 m2/ 15 min
INSTALLATION AND OPERATION OF THE DEVICE
Open the package and dispose of allits materials in an environmentally safe manner. Waste electrical equipment does notbelong to household waste. Electrical and electronic
equipment must be disposed of separately from general household waste through government waste disposal facilities in accordance with directive 2002/96/EC and national
legislation. This can be done by returning it, when buying a similar device or by handing it over to an authorized collection point for the recycling of electrical and electronic
equipment waste.
The device can be mounted on the floor with a distance
from the wall of 10 cm. Insert the package cable into the
power inlet of the appliance (4) and then into the
corresponding socket.
Turn on the device from the on/off button (5). From
the on /off wireless control (8) switch on the device
from a distance of up to 8 meters. Caution in case
there are intermediate obstacles there will be no
activation.
Adjust the motor volume by the analog regulator (6)
located next to the power button.
Business Conceptions OESTONIA Keemia 4 Tallinn 10616 T: +372 8840581 E-mail: [email protected]
SHELF LIFE OF APPLIANCES & PROPER OPERATING
The filter and sterilization components of the device have the following time limits for proper operation and if you carry out the necessary supervision and maintenance of the
devices. The appliance must not be operated outdoors or in damp rooms, with a humidity of more than 70% or next to a humidifier, next to heaters, fireplaces or appliances
using gas. In environments with temperature fluctuations, as this can lead to water condensation inside. Under normal conditions, filters need cleaning every 3-5 weeks.
Activated carbon filter 1 - 2 years
Bipolar Ionization 4 - 5 years
Fiber Shield™filter 2 έως 3 έτη
Ultraviolet technology 9.000 operating hours (required check annually)
CAUTION: THE DEVICE FILTERS MUST BE CLEANED ONLY WITH AN ELECTRIC VACUUM CLEANER AND NOT WITH WATER.
BASIC EQUIPMENT AND FILTRATION & STERILIZATION DEVICES STAGES
Activated carbon filter: Elimination of pollutants such as HCS, SOx, NOx, CH2O,
H25, chlorine compounds. The ejected air follows EU regulations.
Fibershield™Filter: Is a Nylon, non-woven antimicrobial fiber, infused with specified
concentrations of silver particle technology.
This new technology adds an important layer of protection, as FiberShield™ will
inactivate 99% of microbes that come into contact with it.
The product of PureAir FiberShieldTM showed the Antiviral Activity Rate of
96.58% for SARS-CoV-2, 98.13% for H1N1, 98.48% for H7N9, and 98.62% for
Rhinovirus (host cell: MDCK) according to ISO 18184-2019 based on the test
reports WP-20096694-JC (01-04) of the third-party independent lab testing.
Ultraviolet technology: the models of the BLUE STERI series are equipped with
UVC lamps without Ozon production. Low-pressure lamps that do not contain
mercury, but a special compact amalgam, with alloys of noble metals. Long service
life (up to 9,000 hours) with greater UVC efficiency than conventional lamps (up to
45%).
Bipolar ionization: the technology produces a natural bioclimate rich in positive and
negative oxygen ions. All products have been designed and tested in accordance with
applicable UL or ETL safety standards. PLASMA CONTROL devices can collect
particles as small as 0.001 µm, up to 10 times faster than standard filters. The heat
of electrons is not perceived due to their minuscule mass. Plasma constitutes the
most high energy state of matter and is characterized by the energy and density of
electrons.
MAINTENANCE AND SUPERVISION INSTRUCTIONS
To maintain the filters, the device must be closed by the main switch (6) unscrew the filter Hatch (2) and pull out
the stem. Clean the reattach to the exact same layout screw the hatch again. The device is designed so that
you can easily supervise and maintain its equipment in complete safety. Under normal conditions, filters need
cleaning every 3-5 weeks. You can clean them with a vacuum cleaner. Never clean the filters with water because
they will be damaged.
DEVICE & APPLIANCE ACCESSORIES CERTIFICATION
EUROPEAN COMMUNITY CERTIFICATION
As defined by the Directive of EU LVD 2014/35/EU with the following Standards IEC EN 60335 -1 IEC EN 60335 -2 IEC EN 60529 IEC EN
60417
BuildingService of
Hospitals.
49727/26-04-2010
Compliance based on specifications of the Ministry of Health for E / M ΔΥ8 / Β/49727 / 26-04-2010 / Checking devices against leaks (Leak
Integrity Test) / Hygiene Certificate (Hygiene Certificate) / Absolute filter class (Filter category) / Viruses Neutralization, with UVC power
spreadsheets. Certificates and test report are delivered separately for each device, with a unique production number. ISO 29463-2: 2018 / EN
1822: 2019 Greek Regulations for the Hospital Building Service 49727 / 26-04-2010.
Paint Antibacterial activity on plastic surfaces and other non-porous surfaces for Staphylococcus aureus ATCC 6538P and Escherichia coli ATCC 8739 according to ISO
22196:2011-08, REPORT NO. 20.8.3.0016
Filter Antibacterial activity Pure Air Fiber ShieldTM demonstrated its Inhibitory rate > 99.99 for tested bacteria and fungi, including Staphylococcus Aureus, Escherichia
coli, Pseudomonas Aeruginosa, Hemolytic Streptococcus, Klebsiella Pneumoniae, and Fungi according to GB/T 20944.3-2008, based on the test reports WP-
20096694-JC (05-10) of the third-party independent lab testing. It carries the approvals of EN and FDA, with antibacterial efficacy test compared with standards AATCC 100,
AATCC147, JIS L1902, EN ISO 20645, ISO 18184. Using the ISO 18184 standard, which controls the antiviral activity of any garment or woven material against viruses and
in particular tested against COVID-19 (SARS-CoV-2) as filter material showed a reduction of pathogens by 96.5% after 30 minutes and 98.7% in 1 hour.
US FOOD & DRUG ADMINISTRATION
210(K) MEDICAL DEVICE CLEARANCES
US ENVIRONMENTAL PROTECTION
AGENCY ANTIMICROBIAL REGISTRATIONS
CLEARED FOR USE IN CLASS 1,2,3
MEDICAL DΕVICE FOR AIR FILTER
WARRANTY TERMS
The guarantee is considered valid only in case of possession of the purchase document.
The five-year (5) warranty covers the proper operation of the motor and the electrical equipment management board. Required maintenance, with compatible
consumables and Authorized service.
The warranty is waived for damages caused by failure to comply with the instructionsaccompanying the product at the time of purchase:
Failure to periodically inspect, maintain, repair or replace components due to proper use. Use of incompatible spare parts or consumables. Compatibility is ensured only by
using products purchased or offered by our company. Damage caused by modification of device / system without prior consent of the company. Improper use of the product,
drop. Modifications or repairs by unauthorized personnel.
Business Conceptions OESTONIA Keemia 4 Tallinn 10616 T: +372 8840581 E-mail: [email protected]
REFUNDS
To return defective materials, you must request the authorization to return goods by sending an email to the store that supplied the device or by calling its phone number.
Only authorized products will be accepted, otherwise they will be rejected and returned to the sender.
RESPONSIBILITY AND COMMITMENTS OF MANUFACTURER AND DISTRIBUTION COMPANY
The Company assumes no responsibility for any damage to individuals or property, due to failure to follow instructions or use of technology without the safety provisions
provided. We suggest you carefully read all the instructions or consult the Engineering Department of our company. The manufacturer agrees with the buyer to provide,
upon request, circuit diagrams, lists of spare parts, instructions for calibrating lamps and other information, which are useful for repairing parts that the manufacturer
considers serviceable. The company reserves the right to make changes without notice.

Other Blue Steri Air Cleaner manuals

Blue Steri BST-200 User manual

Blue Steri

Blue Steri BST-200 User manual

Blue Steri BST500 User manual

Blue Steri

Blue Steri BST500 User manual

Popular Air Cleaner manuals by other brands

Steel City 65120 user manual

Steel City

Steel City 65120 user manual

CFM CX1000 user guide

CFM

CFM CX1000 user guide

Amana Media MAC1 Series installation instructions

Amana

Amana Media MAC1 Series installation instructions

Glaziar PUR50 Instructions for use

Glaziar

Glaziar PUR50 Instructions for use

Panasonic F-PXR40H operating instructions

Panasonic

Panasonic F-PXR40H operating instructions

Lightair IonFlow 50 manual

Lightair

Lightair IonFlow 50 manual

Lennox Healthy Climate PMAC-12C brochure

Lennox

Lennox Healthy Climate PMAC-12C brochure

IKEA UPPÅTVIND quick start guide

IKEA

IKEA UPPÅTVIND quick start guide

Nash AP-1 PureSmart instruction manual

Nash

Nash AP-1 PureSmart instruction manual

Aktobis WDH-220B manual

Aktobis

Aktobis WDH-220B manual

Honeywell HHT-013-HD user guide

Honeywell

Honeywell HHT-013-HD user guide

LG PH-U450 Series owner's manual

LG

LG PH-U450 Series owner's manual

Sharp FU-40SE Operation manual

Sharp

Sharp FU-40SE Operation manual

Philips AC2721 user manual

Philips

Philips AC2721 user manual

Filtrete FAP-T02 manual

Filtrete

Filtrete FAP-T02 manual

DeLonghi DDSX 220WFA manual

DeLonghi

DeLonghi DDSX 220WFA manual

TruSens Z-2000 manual

TruSens

TruSens Z-2000 manual

Motorola MBP87SN quick start guide

Motorola

Motorola MBP87SN quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.