Blue Steri BST500 User manual

BLUE STERI
User
Manual
/ Technical
Instructions
Please read this manual before using the device and keep it for
authorized users, to assist them in the safe installation, use, maintenance and repair of the units.
No part of this publication may be copied or
published via print, photocopy, microfilm or otherwise without prior written consent of the manufacturer. This restriction al
applies to the corresponding drawings and diagrams. The information given in this manual has been collected for the general c
time, to change or modification by the manufacturing company
SAFETY INSTRUCTIONS
Read this manual carefully
before using the device. Installation of the device must be
carried out in accordance with domestic safety rules. In case you have any doubt about the
suitability of your electrical supply/wall outlet, if it is properly grounded or protected by safety,
call a qualified technician/electrician.
This device has been tested and certified for its safe operation.
like any electrical appliance, it should be used with caution.
off. Then unplug the appliance
before cleaning, assembling or disassembling the appliance.
This device only connects to a grounded socket at 220
moving parts of the device. Never put your fingers or other objects in the air inlets and outlets.
Children
should be supervised to ensure that they do not play with the appliance
This device is not intended for use
by persons (including children) with reduced physical,
sensoryor mental capacity or by persons with a lack of experience or knowledge, unless
supe
rvised or instructed in the use of the device by any person responsible for their safety.
Do not clean the appliance by splashing it or immersing it in water.
appliance into the outlet using an extension cord/ballad. In the event that there
available, it should be installed by a qualified technician. Do not plug in or unplug the
appliance with wet hands. Danger of electric shock. A damaged power supply cable should
only be replaced by a qualified technician to avoid possible inj
Do not use the device for purposes other than those for which it was designed.
device must always be stored and moved to an upright position. Do not switch the appliance
on or off by plugging in and unplugging it. Use the ON / OFF button to turn
off. The appliance must not be placed in the bathroom or in damp places.
ENERGY SAVING AND USEFUL SAFETY TIPS
Do not cover or prevent
air from entering and leaving the grilles.
Keep the filters clean.
Under normal conditions, the filters need cleaning every
Clean the filters with a vacuum cleaner.
Never clean the filters with water.
C
all our authorized partner for the annual check of the device.
INTENDED USE
The
device is used to control and deactivate viruses and air
pollutants. Provides certified effective disinfection to bacteria,
fungi, allergens, volatile and organic loads and has a
photocatalytic dosage inside the reactor to inactivate SARS
2.
It is des
igned for use in private and commercial buildings. The
user must comply with the operating parameters specified in these
instructions. Operate the appliance on flat, stable and dry
surfaces,
in a temperature range between 0 °C and 50 °C and
humidity below 70%.
BLUE STERI
BST500 – 1000 - 2000
ULTRAVIOLET AIR & OBJECT PURIFICATION SYSTEMS
Instructions
Please read this manual before using the device and keep it for
future reference. This manual is intended to be used as a reference project by individuals, professionals and
authorized users, to assist them in the safe installation, use, maintenance and repair of the units.
published via print, photocopy, microfilm or otherwise without prior written consent of the manufacturer. This restriction al
applies to the corresponding drawings and diagrams. The information given in this manual has been collected for the general c
on
time, to change or modification by the manufacturing company
.
before using the device. Installation of the device must be
carried out in accordance with domestic safety rules. In case you have any doubt about the
suitability of your electrical supply/wall outlet, if it is properly grounded or protected by safety,
This device has been tested and certified for its safe operation.
In any case, however,
like any electrical appliance, it should be used with caution.
Make sure the device is turned
before cleaning, assembling or disassembling the appliance.
This device only connects to a grounded socket at 220
-240V / 50Hz. Avoid touching or
moving parts of the device. Never put your fingers or other objects in the air inlets and outlets.
should be supervised to ensure that they do not play with the appliance
.
by persons (including children) with reduced physical,
sensoryor mental capacity or by persons with a lack of experience or knowledge, unless
rvised or instructed in the use of the device by any person responsible for their safety.
Do not clean the appliance by splashing it or immersing it in water.
Never plug the
appliance into the outlet using an extension cord/ballad. In the event that there
is no socket
available, it should be installed by a qualified technician. Do not plug in or unplug the
appliance with wet hands. Danger of electric shock. A damaged power supply cable should
only be replaced by a qualified technician to avoid possible inj
ury.
Do not use the device for purposes other than those for which it was designed.
This
device must always be stored and moved to an upright position. Do not switch the appliance
on or off by plugging in and unplugging it. Use the ON / OFF button to turn
the device on or
off. The appliance must not be placed in the bathroom or in damp places.
ENERGY SAVING AND USEFUL SAFETY TIPS
air from entering and leaving the grilles.
Under normal conditions, the filters need cleaning every
3-5 weeks.
all our authorized partner for the annual check of the device.
NON FORESEEABLEUSE
device is used to control and deactivate viruses and air
pollutants. Provides certified effective disinfection to bacteria,
fungi, allergens, volatile and organic loads and has a
photocatalytic dosage inside the reactor to inactivate SARS
-CoV-
igned for use in private and commercial buildings. The
user must comply with the operating parameters specified in these
instructions. Operate the appliance on flat, stable and dry
in a temperature range between 0 °C and 50 °C and
The appliance must not be operated
outdoors or in damp areas with a humidity of
more than 70% or next to a humidifier next to heaters, fireplaces or appliances using
gas. In environment
s with temperature fluctuations, as this can lead to
condensation inside. The device is not intended for drying
Do not place the appliance near other heat sources. It may cause deterioration of its
plastics and fire. Do not use the device nea
gasoline, solvents, etc. Fire hazard. Do not place objects on the device. Always
place the appliance in a dry place and on a flat surface.
future reference. This manual is intended to be used as a reference project by individuals, professionals and
published via print, photocopy, microfilm or otherwise without prior written consent of the manufacturer. This restriction al
so
on
venience of our customers. Subject, at any
outdoors or in damp areas with a humidity of
more than 70% or next to a humidifier next to heaters, fireplaces or appliances using
s with temperature fluctuations, as this can lead to
water
condensation inside. The device is not intended for drying
items.
Do not place the appliance near other heat sources. It may cause deterioration of its
plastics and fire. Do not use the device nea
r flammable gases or materials such as
gasoline, solvents, etc. Fire hazard. Do not place objects on the device. Always
place the appliance in a dry place and on a flat surface.

DIAGRAM AND BASIC PARTS OF THE DEVICE
1 Αmbient air inlet
2 Dust filter G3
3 CARBON filter
4 HEPA filter
5 Filter supervision visiting port
6 General device switch
TECHNICAL CHARACTERISTICS
AIR SUPPLY: m3/h
VOLTAGE : (V)
AMPERAGE : (Α)
ENERGY CONSUMPTION : (ΚW)
MOTOR POWER: (W)
DECIBEL : Db(a)
FILTRATION
PRE FILTER G3 : (ΕΝ 779)
HEPA FILTER: (HEPA)
CARBON FILTER: (CARBON)
STERILIZATION
UVC LAMPS : TEM / (W)
FREQUENCY : Nm
NEGATIVE ION/ POSITIVE IONS : (V)
OZONE OUTPUT : PPM
SPACE COVERAGE (Height 2,5m) : m2 / min
MOTOR POWER CONTROL:
DIGITAL DETECTOR :
Air quality detector with temperature, humidity, carbon dioxide, TVOC and formaldehyde (HCHO) sensor
DIMENSIONS (W-D-H) : mm
WEIGHT : kg
DIAGRAM AND BASIC PARTS OF THE DEVICE
7 Air supply regulator analog 13
8 Centrifugal ventilator 14
9 Lamp supervision compartment 15
10 Electrical supply compartment 16
11 Device power supply 17
12 Liquid solution tank 18
19
ΒST 1000
500 έως 1000
230
4.3 – 4.9
0.98 – 1.27
135
30 – 45
340 x 370 x 5
340 x 370 x 5
340 x 370 x 5
2 Χ 80W
254
Neg-11.000 / Pos+ 9.000
0,04
200 m2 / 60min 400 m2 / 60min
100 m2 / 30min200 m2 / 30min
60 m2 / 20min100 m2 / 20min
40 m2 / 10min70 m2 / 10min
Speed adjustment
Air quality detector with temperature, humidity, carbon dioxide, TVOC and formaldehyde (HCHO) sensor
450*400*1000
55
UVC lamps
Air extraction
Device scroll wheels
Screen switch
Environment measurement table
Fresh air supply box
Co2Controller
ΒST 2000
1000 - 2000
230
2.1 – 6.2
0.48 – 1.40
250
30 - 55
340 x 370 x 5
340 x 370 x 5
340 x 370 x 5
4 Χ 80W
254
Neg-33.000 / Pos+ 27.000
700 m2 / 60min
350 m2 / 30min
250 m2 / 20min
200 m2 / 10min
Air quality detector with temperature, humidity, carbon dioxide, TVOC and formaldehyde (HCHO) sensor
450*400*1000
70

INSTALLATION AND OPERATION OF THE DEVICE
Open the package and dispose of all its materials in an environmentally safe
manner. Waste electrical equipment does not belong to household waste.
Electrical and
electronic equipment must be disposed of separately from general
household waste through government waste disposal facilities in accordance with
directive 2002/96/EC and national legislation.
This can be done by returning it, when buying a similar device
to an authorized collection point for the recycling of
equipment waste.
The device can be mounted on the floor with a distance from the wall of 10 cm.
Insert the package cable into the (11) socket of the app
corresponding socket. Turn
on the device from the ON / OFF button (6) located
above the power switch.
Adjust the motor speed by the analog regulator (7) located next to the power
button (analog models).
Adjust the motor power
from the on/off hand control (DIGITAL models)
Press and hold the button (16) on the air quality diagnostic instrument until the
indications (17) appear.
Air quality detector with temperature, humidity, carbon dioxide, TVOC and
formaldehyde (HCHO) sensor.
BASIC EQUIPMENT AND TECHNOLOGICAL PRESENTATION OF THE DEVICE
FILTRATION PROCEDURES
Dust filter:For therestraining of Pm10 particles
according to ISO16890 and
protection of the absolute filter. Large dust
capacity and very stable and durable
structure. The pre-
filter removes dust, hairs and other larger particles.
Activatedcarbonfilter:
Elimination of pollutants such as HCS, SOx, NOx, CH2O,
H25, chlorine compounds. The ejected air follows EU regulations.
HEPAfilter:
They are used in the medical industry for applications mainly in
operating rooms and places that require prevention of the spread of bacteria and
viruses.
They can collect particles as small as 0.3 µm
applications is ac
companied by strict maintenance and replacement protocols.
Fibershield™ Filter: Is a Nylon, non-
woven antimicrobial fiber, infused with
specified concentrations of silver particle technology.
This new technology adds an important layer of protection, as
inactivate 99% of microbes that come into contact with it.
The product of PureAir FiberShieldTM
showed the Antiviral Activity Rate of 96.58%
for SARS-CoV-
2, 98.13% for H1N1, 98.48% for H7N9, and 98.62% for Rhinovirus
(host cell: MDCK) according to ISO 18184-
2019 based on the test reports WP
20096694-JC (01-04)of the third-
party independent lab testi
MAINTENANCE AND SUPERVISION INSTRUCTIONS
FILTERMAINTENANCE:
To
maintain the filters, the device must be turned off by the central Switch (6) and
unscrew the visiting Port (5). Pull out each strain of the filters and after cleaning them,
reposition them in the exact same arrangement and close the visiting port.
The dev
ice is designed so that you can easily supervise and maintain its equipment in
complete safety. Under normal conditions, filters need cleaning every
can clean them with a vacuum cleaner. Never clean the filters with water
damaged.
LAMPS MAINTENANCE AND SUPERVISION:
To maintain the lamps, close the appliance by the main switch (6) and unscrew the
visiting Port (5). Pull out each bulb stem and after cleaning their surface with a cotton
cloth,
reposition in exactly the same arrangement and close the visiting Hatch.
Under normal conditions, lamps need cleaning every 1 year. Never clean the lamps
with water because they will be damaged.
INSTALLATION AND OPERATION OF THE DEVICE
Open the package and dispose of all its materials in an environmentally safe
manner. Waste electrical equipment does not belong to household waste.
electronic equipment must be disposed of separately from general
household waste through government waste disposal facilities in accordance with
This can be done by returning it, when buying a similar device
or by handing it over
electrical and electronic
The device can be mounted on the floor with a distance from the wall of 10 cm.
Insert the package cable into the (11) socket of the app
liance and then into the
on the device from the ON / OFF button (6) located
Adjust the motor speed by the analog regulator (7) located next to the power
from the on/off hand control (DIGITAL models)
.
Press and hold the button (16) on the air quality diagnostic instrument until the
Air quality detector with temperature, humidity, carbon dioxide, TVOC and
BASIC EQUIPMENT AND TECHNOLOGICAL PRESENTATION OF THE DEVICE
according to ISO16890 and
capacity and very stable and durable
filter removes dust, hairs and other larger particles.
Elimination of pollutants such as HCS, SOx, NOx, CH2O,
H25, chlorine compounds. The ejected air follows EU regulations.
They are used in the medical industry for applications mainly in
operating rooms and places that require prevention of the spread of bacteria and
They can collect particles as small as 0.3 µm
.Their use in commercial
companied by strict maintenance and replacement protocols.
woven antimicrobial fiber, infused with
This new technology adds an important layer of protection, as
FiberShield™ will
showed the Antiviral Activity Rate of 96.58%
2, 98.13% for H1N1, 98.48% for H7N9, and 98.62% for Rhinovirus
2019 based on the test reports WP
-
party independent lab testi
ng.
STERILIZATION PROCEDURES
Ultraviolet technology:
the models of the BLUE STERI series are equipped with
UVC lamps without Ozon production. Low
mercury, but a special compact amalgam, with alloys of noble metals. Long
life (up to 9,000 hours) with greater UVC efficiency than conventional lamps (up to
45%).
Bipolar ionization:
the technology produces a natural bioclimate rich in positive
and negative oxygen ions. All products have been designed and tested in
accordance with applicable UL or ETL safety standards. PLASMA CONTROL
devices can collect particles as small as
standard filters. The heat of electrons is not perceived due to their minuscule mass.
Plasma constitutes the most high energy state of matter and is characterized by the
energy and density of electrons.
Self-cleaning spray system:
the innovative patented automatic disinfection
process of the device aims to directly sterilize the internal chamber of the device
and the surfaces of the filters. For the above procedure the device has an advanced
nanopspray sy
stem dispersing on the surface disinfectant liquid Kohrsolin FF,
complying with the European biocidal products directive. Bactericidal MRSA,
fungicide, according to VAH/DGHM/EN1276/en 1275/EN 1650 active against all
covered viruses, hepatitis B / HIV and h
disinfection and simultaneous cleaning of high and
floors and walls of operating rooms, ICU
dispensaries, etc. It is a liquid of pleasant
surfaces and biologically degradable.
marketingauthorization approved by
National Organization for Medicines
MAINTENANCE AND SUPERVISION INSTRUCTIONS
maintain the filters, the device must be turned off by the central Switch (6) and
unscrew the visiting Port (5). Pull out each strain of the filters and after cleaning them,
reposition them in the exact same arrangement and close the visiting port.
ice is designed so that you can easily supervise and maintain its equipment in
complete safety. Under normal conditions, filters need cleaning every
3-5 weeks. You
can clean them with a vacuum cleaner. Never clean the filters with water
,as they will be
To maintain the lamps, close the appliance by the main switch (6) and unscrew the
visiting Port (5). Pull out each bulb stem and after cleaning their surface with a cotton
reposition in exactly the same arrangement and close the visiting Hatch.
Under normal conditions, lamps need cleaning every 1 year. Never clean the lamps
STERILIZATION PROCEDURES
the models of the BLUE STERI series are equipped with
UVC lamps without Ozon production. Low
-pressure lamps that do not contain
mercury, but a special compact amalgam, with alloys of noble metals. Long
service
life (up to 9,000 hours) with greater UVC efficiency than conventional lamps (up to
the technology produces a natural bioclimate rich in positive
and negative oxygen ions. All products have been designed and tested in
accordance with applicable UL or ETL safety standards. PLASMA CONTROL
devices can collect particles as small as
0.001 µm, up to 10 times faster than
standard filters. The heat of electrons is not perceived due to their minuscule mass.
Plasma constitutes the most high energy state of matter and is characterized by the
the innovative patented automatic disinfection
process of the device aims to directly sterilize the internal chamber of the device
and the surfaces of the filters. For the above procedure the device has an advanced
stem dispersing on the surface disinfectant liquid Kohrsolin FF,
complying with the European biocidal products directive. Bactericidal MRSA,
fungicide, according to VAH/DGHM/EN1276/en 1275/EN 1650 active against all
covered viruses, hepatitis B / HIV and h
epatitis C. Kohrsolin FF covers the needs of
disinfection and simultaneous cleaning of high and
unprotected surfaces such as
floors and walls of operating rooms, ICU
s, patient wards, toilets, lab benches,
dispensaries, etc. It is a liquid of pleasant
smell, low foaming, compatible with metal
surfaces and biologically degradable.
It bears the "CE" marking and has a
National Organization for Medicines
.

SHELF LIFE OF APPLIANCES &PROPER
OPERATING
The filter and sterilization components of the device have the following time limits for proper operation and if you carry ou
the devices. The appliance must not be operated outdoors or in damp rooms, with a hu
appliances using gas. In environments with temperature fluctuations, as this can lead to water condensation inside.
3-5 weeks.
APPLIANCE ACCESSORIES
Dust prefilter
Activated carbon filter
HEPA filter
Fiber shield™ filter
Ultraviolet technology
Bipolar Ionization
DEVICE
&
APPLIANCE ACCESSORIES
CERTIFICATION
EUROPEAN COMMUNITY CERTIFICATION
As defined by the Directive of EU LVD 2014/35/EUwith the following Standards IEC EN 60335
60417
BuildingService of
Hospitals.
49727/26-04-2010
Compliance based on specifications of the Ministry of Health
(Leak Integrity Test) / Hygiene Certificate (Hygiene Certificate) / Absolute
spreadsheets. Certificates and test report are delivered separately for each device
1822: 2019 Greek Regulations for the Hospital Building Service 49727 / 26
PaintAntibacterial activity
on plastic surfaces and other non
22196:2011-08, REPORT NO. 20.8.3.0016.
FilterAntibacterialactivityPureAir Fiber ShieldTM
demonstrated its
Rhinovirus (host cell: MDCK) according to ISO 18184-
2019 based on WP
approvals of EN
and FDA, with antibacterial efficacy test compared with standards AATCC 100, AATCC147, JIS L1902, EN ISO 20645, ISO 18184. Us
standard, which controls the antiviral activity of any garment or woven material against viruses and
showed a reduction of pathogens by 96.5% after 30 minutes and 98.7% in 1 hour.
US FOOD & DRUG ADMINISTRATION
210(K) MEDICAL DEVICE CLEARANCES
HEPA FILTER CLASSIFICATION(S): EN1822 H14
resin binder.
WARRANTY TERMS
The guarantee is considered valid only in case of possession of the purchase document.
The warranty is waived for damages caused by
failure to comply with the instructions
Failure to periodically ins
pect, maintain, repair or replace components due to
using products purchased or offered by our company. Damage caused by modification of device / system without
product, drop. Modifications or repairs by unauthorized personnel.
REFUNDS
To
return defective materials, you must request the authorization to return goods by sending an email to the store that supplied
Only authorized products will be accepted, otherwise they will be rejected and
RESPONSIBILITY AND COMM
ITMENTS OF MANUFACTURER AND DISTRIBUTION COMPANY
The Company assumes no responsibility for any damage to individuals or property, due to failure to follow instructions or use
provided. We suggest you carefully read all the instructions or consult the Engineerin
upon request, circuit diagrams
, lists of spare parts, instructions for calibrating lamps and other information, which are useful for repairing parts that t
consi
ders serviceable. The company reserves the right to make changes without notice.
OPERATING
The filter and sterilization components of the device have the following time limits for proper operation and if you carry ou
t the necessary supervision and maintenance of
the devices. The appliance must not be operated outdoors or in damp rooms, with a hu
midity of more than 70% or next to a humidifier, next to heaters, fireplaces or
appliances using gas. In environments with temperature fluctuations, as this can lead to water condensation inside.
Under normal conditions,
SELF LIFE
4 - 5 years
1 - 2 years
1 - 2 years
1 - 2 years
13.000 operatinghours(required check annually)
4 - 5 years
CERTIFICATION
EUROPEAN COMMUNITY CERTIFICATION
As defined by the Directive of EU LVD 2014/35/EUwith the following Standards IEC EN 60335
-
1 IEC EN 60335
Compliance based on specifications of the Ministry of Health
for E / M ΔΥ8 / Β
/49727 / 26
(Leak Integrity Test) / Hygiene Certificate (Hygiene Certificate) / Absolute
filter class (Filter category) /
spreadsheets. Certificates and test report are delivered separately for each device
,
with a unique production number. ISO 29463
1822: 2019 Greek Regulations for the Hospital Building Service 49727 / 26
-04-2010.
on plastic surfaces and other non
-porous surfaces for Staphylococcus aureus ATCC 6538P a
nd Escherichia coli ATCC 8739 according to ISO
demonstrated its
Antiviral ActivityRateof 96.58% for SARS-CoV-
2, 98.13% for H1N1, 98.48% for H7N9, and 98.62% for
2019 based on WP
-20096694-JC (01-04) test reports from a third party
Independent Testing Laboratory. It carries the
and FDA, with antibacterial efficacy test compared with standards AATCC 100, AATCC147, JIS L1902, EN ISO 20645, ISO 18184. Us
standard, which controls the antiviral activity of any garment or woven material against viruses and
in particul
ar tested against COVID
showed a reduction of pathogens by 96.5% after 30 minutes and 98.7% in 1 hour.
US FOOD & DRUG ADMINISTRATION
210(K) MEDICAL DEVICE CLEARANCES
US ENVIRONMENTAL PROTECTION
AGENCY ANTIMICROBIAL REGISTRATIONS
HEPA FILTER CLASSIFICATION(S): EN1822 H14
@ 2.5 cm/s
Low resistance HEPA filter consisting of borosilicate microfiber with acrylic
The guarantee is considered valid only in case of possession of the purchase document.
failure to comply with the instructions
accompanying the product at the time of purchase
pect, maintain, repair or replace components due to
proper use.
Use of incompatible spare parts or consumables. Compatibility is ensured only by
using products purchased or offered by our company. Damage caused by modification of device / system without
prior consent of the company. Improper use of the
product, drop. Modifications or repairs by unauthorized personnel.
return defective materials, you must request the authorization to return goods by sending an email to the store that supplied
Only authorized products will be accepted, otherwise they will be rejected and
returned to the sender.
ITMENTS OF MANUFACTURER AND DISTRIBUTION COMPANY
The Company assumes no responsibility for any damage to individuals or property, due to failure to follow instructions or use
provided. We suggest you carefully read all the instructions or consult the Engineerin
g Department of our company. The manufacturer agrees with the buyer to provide,
, lists of spare parts, instructions for calibrating lamps and other information, which are useful for repairing parts that t
ders serviceable. The company reserves the right to make changes without notice.
t the necessary supervision and maintenance of
midity of more than 70% or next to a humidifier, next to heaters, fireplaces or
Under normal conditions,
filters need cleaning every
1 IEC EN 60335
-2 IEC EN 60529 IEC EN
/49727 / 26
-04-2010 / Checking devices against leaks
filter class (Filter category) /
Viruses Neutralization, with UVC power
with a unique production number. ISO 29463
-2: 2018 / EN
nd Escherichia coli ATCC 8739 according to ISO
2, 98.13% for H1N1, 98.48% for H7N9, and 98.62% for
Independent Testing Laboratory. It carries the
and FDA, with antibacterial efficacy test compared with standards AATCC 100, AATCC147, JIS L1902, EN ISO 20645, ISO 18184. Us
ing the ISO 18184
ar tested against COVID
-19 (SARS-CoV-2)as filter material
CLEARED FOR USE IN CLASS 1,2,3
MEDICAL DΕVICE FOR AIR FILTER
Low resistance HEPA filter consisting of borosilicate microfiber with acrylic
accompanying the product at the time of purchase
:
Use of incompatible spare parts or consumables. Compatibility is ensured only by
prior consent of the company. Improper use of the
return defective materials, you must request the authorization to return goods by sending an email to the store that supplied
the device or by calling its phone number.
ITMENTS OF MANUFACTURER AND DISTRIBUTION COMPANY
The Company assumes no responsibility for any damage to individuals or property, due to failure to follow instructions or use
of technology without the safety provisions
g Department of our company. The manufacturer agrees with the buyer to provide,
, lists of spare parts, instructions for calibrating lamps and other information, which are useful for repairing parts that t
he manufacturer

Business Conceptions OÜ
E-mail:
info@bluesteri.com
Sales and Service
GERMANY
Lindenstr. 118 – 47798 Krefeld
T: +49 (0)2151 4420806
M: +49 (0)1787 445 876
Business Conceptions OÜ
ESTONIAKeemia 4 Tallinn 10616 T:
+372 8840581
E-mail: contact@businessconceptions.eu
Sales and Service
Departments
ENGLAND
6A Dickensons Place
London, SE 25 5 HL, UK
T: +44 74 521 10279
Evdoxou 1 Metamorfosi Attica14451
T: +30 6938039319 T: +30 6909444697
+372 8840581
GREECE
Evdoxou 1 Metamorfosi Attica14451
T: +30 2102817012
T: +30 6938039319 T: +30 6909444697
This manual suits for next models
2
Table of contents
Other Blue Steri Air Cleaner manuals