BLUE STERI BST –200
ULTRAVIOLET AIR & OBJECT PURIFICATION SYSTEMS
User Manual / Technical Instructions
Please read this manual before using the device and keep it for future reference. This manual is intended to be used as a reference project by individuals, professionals and authorized
users, to assist them in the safe installation, use, maintenance and repair of the units.
No part of this publication may be copied or published via print, photocopy, microfilm or otherwise without prior written consent of the manufacturer. This restriction also applies to the
corresponding drawings and diagrams. The information given in this manual has been collected for the general convenience of our customers. Subject, at any time, to change or
modification by the manufacturing company.
SAFETY INSTRUCTIONS
✓Read this manual carefully before using the device. Installation of the device must be carried out in accordance
with domestic safety rules. In case you have any doubt about the suitability of your electrical supply/wall outlet,
if it is properly grounded or protected by safety, call a qualified technician/electrician
✓This device has been tested and certified for its safe operation. In any case, however, like any electrical
appliance, it should be used with caution. Make sure the device is turned off. Then unplug the appliance before
cleaning, assembling or disassembling the appliance.
✓This device only connects to a grounded socket at 220-240V / 50Hz.. Avoid touching or moving parts of the
device. Never put your fingers or other objects in the air inlets and outlets. Children should be supervised to
ensure that they do not play with the appliance.
✓This device is not intended for use by persons (including children) with reduced physical, sensory or mental
capacity or by persons with a lack of experience or knowledge, unless supervised or instructed in the use of the
device by any person responsible for their safety.
✓Do not clean the appliance by splashing it or immersing it in water. Never plug the appliance into the outlet
using an extension cord/ballad. In the event that there is no socket available, it should be installed by a qualified
technician. Do not plug in or unplug the appliance with wet hands. Danger of electric shock. A damaged power
supply cable should only be replaced by a qualified technician to avoid possible injury.
✓Do not use the device for purposes other than those for which it was designed. This device must always be
stored and moved to an upright position. Do not switch the appliance on or off by plugging in and unplugging it.
Use the ON / OFF button to turn the device on or off. The appliance must not be placed in the bathroom or in
damp places.
ENERGY SAVING AND USEFUL SAFETY TIPS
✓Do not cover or prevent air from entering and leaving the grilles.
✓Keep the filters clean. Under normal conditions, the filters need cleaning every 3-5 weeks.
✓Clean the filters with a vacuum cleaner.
✓Never clean the filters with water.
✓Call our authorized partner for the annual check of the device..
INTENDED USE
NON FORESEEABLE USE
The device is used to control and deactivate viruses and air pollutants. Provides
certified effective disinfection to bacteria, fungi, allergens, volatile and organic
loads and has a photocatalytic dosage inside the reactor to inactivate SARS-CoV-
2.
It is designed for use in private and commercial buildings. The user must comply
with the operating parameters specified in these instructions. Operate the
appliance on flat, stable and dry surfaces, in a temperature range between 0 °C
and 50 °C and humidity below 70%.
The appliance must not be operated outdoors or in damp areas with a humidity of
more than 70% or next to a humidifier next to heaters, fireplaces or appliances using
gas. In environments with temperature fluctuations, as this can lead to water
condensation inside. The device is not intended for drying items.
Do not place the appliance near other heat sources. It may cause deterioration of
its plastics and fire. Do not use the device near flammable gases or materials such
as gasoline, solvents, etc. Fire hazard. Do not place objects on the device. Always
place the appliance in a dry place and on a flat surface...
Business Conceptions OESTONIA Keemia 4 Tallinn 10616 T: +372 8840581 E-mail: info@bluesteri.com
DIAGRAM AND BASIC PARTS OF THE DEVICE
1
FILTERED AIR OUTLET
6
FLOOR BASE
11
IONIZATION SWITCH
2
WALL BASE (ΟPTIONAL PARTS)
7
ANTI-VIBRATION WALL BASES
12
OZONIC DEODORIZATION SWITCH
3
IONIZATION SWITCH
8
AIR INLET
13
LAMPS LIGHT INDICATION
4
DEVICE FILTERS (ΗEPA + Fiber shield™)
9
DEVICE POWER SUPPLY
14
AIR SUPPLY ANALOG REGULATOR
5
FILTER COVER
10
INTERNAL CHAMBER PORT
15
WIRELESS CONTROL (ON/OFF)
TECHNICAL CHARACTERISTICS
ΒST 200
CLEAN AIR DELIVERY RATE (CADR) :
m3/h
70 / 200
VOLTAGE :
(V)
230
AMPERAGE :
(Α)
1.3 –2.3
ENERGY CONSUMPTION :
(ΚW)
120 –150
MOTOR POWER :
(W)
18
DECIBEL :
Db(a)
30 –45
DIMENSIONS (W-D-H) :
mm
420 x 265 x 950
WEIGHT :
kg
12
FILTRATION
HEPA FILTER :
HEPA H10
150 x 365 x 20 (mm)
Fiber shield™ FILTRER :
Fiber shield™
150 x 365 x 2 (mm)
IONIZATION :
PLASMA
██
NEGATIVE ION/ POSITIVE IONS :
(V)
Neg-11.000 / Pos+ 9.000
OZONE OUTPUT :
PPM
0,04
STERILIZATION
UVC LAMPS :
P / (W)
1 x 80W
FREQUENCY :
Nm
254
CONTROL
ANALOG MOTOR REGULATOR :
██
WIRELESS CONTROL (on/off) :
██
WIFI REMOTE MANAGEMENT :
██
AIR QUALITY DIGITAL DETECTOR :
OPTION
STERILIZATION (OPTION) OZONIC OPERATION :
OPTION
AIR PROCESS CAPACITY
SPACE COVERAGE
80 m2/ 60 min
(Height 2,5m)
40 m2/ 30 min
CLEAN AIR per m2/min :
20 m2/ 15 min
Business Conceptions OESTONIA Keemia 4 Tallinn 10616 T: +372 8840581 E-mail: info@bluesteri.com
INSTALLATION AND OPERATION OF THE DEVICE
Open the package and dispose of allits materials in an environmentally safe manner. Waste electrical equipment does not belong to household waste. Electrical and electronic equipment
must be disposed of separately from general household waste through government waste disposal facilities in accordance with directive 2002/96/EC and national legislation. This can
be done by returning it, when buying a similar device or by handing it over to an authorized collection point for the recycling of electrical and electronic equipment waste.
The device can be mounted on the floor with a distance from
the wall of 10 cm. Insert the package cable into the power inlet
of the appliance (9) and then into the corresponding socket.
Turn on the device from the ON / OFF button (11). From the on /off
wireless control switch on the device from a distance of up to 8
meters. Caution in case there are intermediate obstacles there will
be no activation.
Adjust the motor volume by the analog
regulator (14) located next to the power
button.
OZONIC DEODORIZATION PROCEDURE (option)
The ozonic function has been applied to the device as an optional equipment for cases where it will be necessary to deodorize in a minimum period of time annoying odors from surfaces
and fabrics as well as odors that remain in the room after its use. The process is pre-configured and according to the space usage scenario. It takes place without our presence and the
moment the operation ends we will need to ventilate our space with natural ventilation for a minimum period of time. It is activated by the pushbutton (3) of the device and with pre-
set operating time. It has a motion sensor and in case of intrusion into the deodorization field the process will be stopped automatically.
BASIC EQUIPMENT AND TECHNOLOGICAL PRESENTATION OF THE DEVICE
HEPA filter Η10 : They are used in the medical industry for applications mainly in operating rooms and
places that require prevention of the spread of bacteria and viruses. They can collect particles as small as
0.3 µm. Their use in commercial applications is accompanied by strict maintenance and replacement
protocols.
Fibershield™ Filter: Is a Nylon, non-woven antimicrobial fiber, infused with specified concentrations of
silver particle technology.
This new technology adds an important layer of protection, as FiberShield™ will inactivate 99% of
microbes that come into contact with it.
The product of PureAir FiberShieldTM showed the Antiviral Activity Rate of 96.58% for SARS-CoV-2,
98.13% for H1N1, 98.48% for H7N9, and 98.62% for Rhinovirus (host cell: MDCK) according to ISO
18184-2019 based on the test reports WP-20096694-JC (01-04) of the third-party independent lab
testing.
Bipolar ionization: the technology produces a natural bioclimate rich in
positive and negative oxygen ions. All products have been designed and
tested in accordance with applicable UL or ETL safety standards. PLASMA
CONTROL devices can collect particles as small as 0.001 µm, up to 10 times
faster than standard filters. The heat of electrons is not perceived due to
their minuscule mass. Plasma constitutes the most high energy state of
matter and is characterized by the energy and density of electrons.
Ultraviolet technology: the models of the BLUE STERI series are equipped
with UVC lamps without Ozon production. Low-pressure lamps that do not
contain mercury, but a special compact amalgam, with alloys of noble
metals. Long service life (up to 9,000 hours) with greater UVC efficiency than
conventional lamps (up to 45%).
MAINTENANCE AND SUPERVISION INSTRUCTIONS
FILTER MAINTENANCE:
To maintain the filters, the device must be turned off by the central Switch (11) and unscrew the filter visiting port
(5) Pull out the strain of filter after cleaning them, reposition them in the exact same position and screw the visiting
port. The device is designed so that you can easily supervise and maintain its equipment in complete safety. Under
normal conditions, filters need cleaning every 3-5 weeks. You can clean them with a vacuum cleaner. Never clean the
filters with water, as they will be damaged.
SHELF LIFE OF APPLIANCES & PROPER OPERATING
The filter and sterilization components of the device have the following time limits for proper operation and if you carry out the necessary supervision and maintenance of the devices.
The appliance must not be operated outdoors or in damp rooms, with a humidity of more than 70% or next to a humidifier, next to heaters, fireplaces or appliances using gas. In
environments with temperature fluctuations, as this can lead to water condensation inside. Under normal conditions, filters need cleaning every 3-5 weeks.
APPLIANCE ACCESSORIES
SELF LIFE
HEPA filter
1 -2 years
Fiber shield™filter
1 -2 years
Ultraviolet technology
9.000 operating hours (required check annually)
Bipolar Ionization
4 -5 years
DEVICE & APPLIANCE ACCESSORIES CERTIFICATION
Business Conceptions OESTONIA Keemia 4 Tallinn 10616 T: +372 8840581 E-mail: info@bluesteri.com
EUROPEAN COMMUNITY CERTIFICATION
As defined by the Directive of EU LVD 2014/35/EUwith the following Standards IEC EN 60335 -1 IEC EN 60335 -2 IEC EN 60529 IEC EN
60417
BuildingService of
Hospitals.
49727/26-04-2010
Compliance based on specifications of the Ministry of Health for E / M ΔΥ8 / Β/49727 / 26-04-2010 / Checking devices against leaks
(Leak Integrity Test) / Hygiene Certificate (Hygiene Certificate) / Absolute filter class (Filter category) / Viruses Neutralization, with UVC power
spreadsheets. Certificates and test report are delivered separately for each device, with a unique production number. ISO 29463-2: 2018 / EN
1822: 2019 Greek Regulations for the Hospital Building Service 49727 / 26-04-2010.
Paint Antibacterial activity on plastic surfaces and other non-porous surfaces for Staphylococcus aureus ATCC 6538P and Escherichia coli ATCC 8739 according to ISO
22196:2011-08, REPORT NO. 20.8.3.0016.
Filter Antibacterial activity Pure Air Fiber ShieldTM demonstrated its Inhibitory rate > 99.99 for tested bacteria and fungi, including Staphylococcus Aureus,
Escherichia coli, Pseudomonas Aeruginosa, Hemolytic Streptococcus, Klebsiella Pneumoniae, and Fungi according to GB/T 20944.3-2008, based on the test
reports WP-20096694-JC (05-10) of the third-party independent lab testing. It carries the approvals of EN and FDA, with antibacterial efficacy test compared with standards
AATCC 100, AATCC147, JIS L1902, EN ISO 20645, ISO 18184. Using the ISO 18184 standard, which controls the antiviral activity of any garment or woven material
against viruses and in particular tested against COVID-19 (SARS-CoV-2) as filter material showed a reduction of pathogens by 96.5% after 30 minutes and 98.7% in 1
hour.
US FOOD & DRUG ADMINISTRATION
210(K) MEDICAL DEVICE CLEARANCES
US ENVIRONMENTAL PROTECTION
AGENCY ANTIMICROBIAL REGISTRATIONS
CLEARED FOR USE IN CLASS 1,2,3
MEDICAL DΕVICE FOR AIR FILTER
HEPA FILTER CLASSIFICATION(S):
EN1822 H10 @ 5.33 cm/s / EN1822 H14 @ 2.5 cm/s Low resistance HEPA filter consisting of borosilicate microfiber with acrylic
resin binder.
WARRANTY TERMS
The guarantee is considered valid only in case of possession of the purchase document.
The two-year (2) warranty covers the proper operation of the motor and the electrical equipment management board. Required maintenance, with compatible consumables and
Authorized service.
The warranty is waived for damages caused by failure to comply with the instructions accompanying the product at the time of purchase:
Failure to periodically inspect, maintain, repair or replace components due to proper use. Use of incompatible spare parts or consumables. Compatibility is ensured only by using products
purchased or offered by our company. Damage caused by modification of device / system without prior consent of the company. Improper use of the product, drop. Modifications or
repairs by unauthorized personnel.
REFUNDS
To return defective materials, you must request the authorization to return goods by sending an email to the store that supplied the device or by calling its phone number. Only authorized
products will be accepted, otherwise they will be rejected and returned to the sender.
RESPONSIBILITY AND COMMITMENTS OF MANUFACTURER AND DISTRIBUTION COMPANY
The Company assumes no responsibility for any damage to individuals or property, due to failure to follow instructions or use of technology without the safety provisions provided. We
suggest you carefully read all the instructions or consult the Engineering Department of our company. The manufacturer agrees with the buyer to provide, upon request, circuit
diagrams, lists of spare parts, instructions for calibrating lamps and other information, which are useful for repairing parts that the manufacturer considers serviceable. The company
reserves the right to make changes without notice.

Other Blue Steri Air Cleaner manuals

Blue Steri BST-100 MIN User manual

Blue Steri

Blue Steri BST-100 MIN User manual

Blue Steri BST500 User manual

Blue Steri

Blue Steri BST500 User manual

Popular Air Cleaner manuals by other brands

Daikin mc70mvm6 Operation manual

Daikin

Daikin mc70mvm6 Operation manual

Levoit Core 200S user manual

Levoit

Levoit Core 200S user manual

Philips AC4025 user manual

Philips

Philips AC4025 user manual

Field Controls Healthy Home System Duo-2000 Installation & maintenance instructions

Field Controls

Field Controls Healthy Home System Duo-2000 Installation & maintenance instructions

GreenTech GT1500 owner's manual

GreenTech

GreenTech GT1500 owner's manual

Bionaire BAP9200C-CN Instruction leaflet

Bionaire

Bionaire BAP9200C-CN Instruction leaflet

Argo PURY PRO operating instructions

Argo

Argo PURY PRO operating instructions

Fumex FA2 Series Operation manual

Fumex

Fumex FA2 Series Operation manual

Fellowes AeraMax 90 Operator's manual

Fellowes

Fellowes AeraMax 90 Operator's manual

KDK RXL45H operating instructions

KDK

KDK RXL45H operating instructions

MICRO-AIR SC 150 owner's manual

MICRO-AIR

MICRO-AIR SC 150 owner's manual

ELICA SNAP manual

ELICA

ELICA SNAP manual

Guardian AC4175 Use & care instructions

Guardian

Guardian AC4175 Use & care instructions

Honeywell HHT145 - HEPA Tower Air Purifier user guide

Honeywell

Honeywell HHT145 - HEPA Tower Air Purifier user guide

Genano 310 troubleshooting guide

Genano

Genano 310 troubleshooting guide

oxytec CLEANAIR CLOUD Operating and maintenance instructions

oxytec

oxytec CLEANAIR CLOUD Operating and maintenance instructions

Miro MSP20UV user manual

Miro

Miro MSP20UV user manual

HoMedics AR-20-GB instruction manual

HoMedics

HoMedics AR-20-GB instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.