USER MANUAL
The BLUGUARD Control Panel is designed for simple operation yet provides the maximum
protection for you. Please read this manual carefully and follow the instructions contained in this
book. Fill in the system information page and store this manual in a safe place for future reference.
Your security system consists of a main control panel, one or more keypads and home automation
HA) modules, various sensors and detectors. An enclosure will contain the control panel, which
includes the system electronics and standby battery.
To ensure that your system is functioning, it is important that you test your system weekly. Please
refer to testing procedures section in this manual. If your system does not function properly, please
contact your system installer for services. There is normally no reason for anyone other than the
installer or service professional to have access to the control panel.
Even though BLUGUARD is an advanced security system, it does not 100% guarantee the
protection against burglary, fire or other loses. Any alarm system whether commercial or residential
is subjected to compromise or failure-to-warn for a variety of reasons. These include:
Intruders may gain access through unprotected openings or have the technical
sophistication to bypass an alarm sensor or disconnect an alarm warning device.
Intrusion detectors, smoke detectors and many sensing devices will not operate without
power. Devices powered by AC will not work if there is no AC power supply for any reason
and the back-up battery is missing, dead or improperly installed.
Alarm warning devices such as sirens may not alert people or wake up sleepers if they are
located on the other side of closed or partly closed doors.
Telephone line needed to transmit alarm events from the premise to a central monitoring
station may be out or temporary out of service. Telephone line is subject to compromise by
sophisticated method of attack.
Smoke detector used in conjunction with the alarm system may not sense fire that start
from where smoke cannot reach the detector such as wall, roof or the other side of the
doors. Smoke detector also may not sense a fire on another level of the residence or
building. In general, detectors may not always warn you about fire caused by carelessness
and safety hazards like smoking, violent explosions, escaping gas, improper storage of
flammable material, overloaded electrical circuits, children playing with matches.
The most common cause of an alarm system not functioning properly when an intrusion or
fire occurs is inadequate maintenance. Therefore, your system should be tested weekly to
ensure all detectors or sensors are working properly.
Installing an alarm system may make you eligible for lower insurance rates but an alarm
system is not a substitute for insurance. Homeowners, property owners and renters should
continue to insure their lives and properties.
SYSTEM INFORMATION
Central Monitoring Station Number :
________________________________
Central Monitoring Station Account Number :
________________________________
Not : All information is subj ct to chang s without prior notic
.
INTRODUCTION
TESTING
LIMITATIONS

version 1.1
2
SmartBus P900
-
V16
N
NN
N
USER MANUAL
Alarm Memory This is the history of the most recent violations that occurred the last time
when an alarm was triggered.
Arm To set the system into the ARMED mode. In this mode, a zone violation will
activate an alarm condition. If the system is programmed accordingly, it will
cause a reporting code to be sent to the central monitoring station.
Bypass To deactivate zone. When the panel is ARMED, violation of a bypassed zone
will be ignored.
Chime A short beep sound from the keypad to indicate a zone is violated.
Day Arm Instant arming that allows for certain preprogrammed, DAY STAY zones to be
violated while the system is armed. In this mode, an ENTRY delay time will be
given to the user to disarm using the keypad after entering the armed
premises.
Day Stay Zone Zones that are bypassed automatically when the system is DAY ARMED.
Disarm To deactivate the system. FIRE, PANIC and MEDICAL remain active while
the system is disarmed.
Duress Code An ambush code which will disarm the system and simultaneously send a
silent distress signal to the central monitoring station.
Entry/Exit Zone A zone with programmable delay time will allow user to exit the premises after
arming the system and disarm by using the keypad after entering the armed
premises. This zone is generally the last exit point and the first entry point of
the building, i.e. the front door of a house.
Follower Zone A zone that may be temporary violated during exit delay period or after the
first violation of an ENTRY/EXIT zone. This allows the user access to disarm
the system. A FOLLOWER zone will behave as an instant zone if it is violated
prior to the violation of an ENTRY/EXIT zone.
Force Arm Arming with exit delay that allows for certain violated zones to be bypassed
temporary. When the violated zones resume, these zones will be protected.
There is an ENTRY delay time in this arming mode.
Home
Automation
HA)
Optional system expander module that allows you to control different light and
appliances from any keypad, remote telephone, cellular phone. It can also be
programmed to turn on/off light at certain time daily or during alarm condition.
Instant Zone When the system is armed, any violation of an instant zone will immediately
cause an alarm condition to be registered.
Master Code Master code is a 4-digit personal identification number that allows you to
enter certain programming mode, arm or disarm the system and remotely
control the system via telephone line.
Night Arm Instant arming that allows for certain preprogrammed, NIGHT STAY zones to
be violated while the system is armed. In this mode, there is no ENTRY delay
time for the user.
Night Stay Zone Zones that are bypassed automatically when the system is NIGHT ARMED.
Partitioning A partitioned system is a single physical security system that provides
independent areas of protection intended for use by independent users.
Remote Control
Arm
Arming with a momentary or latch remote control module. In this mode, it
allows certain violated zones to be bypassed temporary. When the violated
zones resume, the zone will be protected. There is an ENTRY and EXIT
delay time in this arming mode.
User Code User code is a 4-digit personal identification number that allows you to arm or
disarm the system.
Zone A specific area of your premises guarded by sensors, which detect violations
of that area.
GLOSSARY

version 1.1
3
SmartBus P900
-
V16
N
NN
N
USER MANUAL
UNDERSTAND YOUR KEYPAD INDICATORS
ZONE INDICATORS
(R d)
Indicate the status of
the zones
ARMED INDICATOR
(R d)
The indicator is
illuminated when the
system is armed
POWER INDICATOR
(GREEN)
The indicator is
illuminated when AC
power is present
7 VIEW TROUBLE
This key will activate
the VIEW TROUBLE
mode when hold
down for 2 seconds
8 VIEW ALARM
MEMORY
This key will activate
the VIEW ALARM
MEMORY mode
when hold down for 2
seconds
5 TURN ON/OFF HA
POINT
This key will TURN
ON/OFF HA point
when hold down for 2
seconds
MODE
This key will start the
programming or test
mode command
9 CHIME MODE
This key will activate
the CHIME mode
when hold down for 2
seconds
KEYLOCK
INDICATOR
(Orang )
The indicator is
illuminated when the
keypad is locked
MEMORY
INDICATOR
(Orang )
The indicator will slow
flash when the alarm
is triggered
1 AWAY ARM
This key will activate
the AWAY ARM mode
when hold down for 2
seconds
2 DAY ARM
This key will activate
the DAY ARM mode
when hold down for 2
seconds
4 FORCE ARM
This key will activate
the FORCE ARM
mode when hold
down for 2 seconds
3 NIGHT ARM
This key will activate
the NIGHT ARM
mode when hold
down for 2 seconds
FIRE ALARM
This key will activate
the FIRE ALARM
when hold down for 2
seconds
6 BYPASS ZONE
This key will activate
the BYPASS mode
when hold down for 2
seconds
PANIC ALARM
This key will activate
the PANIC ALARM
when hold down for 2
seconds
MEDICAL ALARM
This key will activate
the MEDICAL ALARM
when hold down for 2
seconds
SERVICE INDICATOR
(Orang )
The indicator is
illuminated when the
system is in trouble
condition
HASH ENTER
This key will confirm
all commands entered
to the system
0 HOLIDAY MODE
This key will activate
HOLIDAY mode when
hold down for 2
seconds
STAR CANCEL
This key will cancel
any unintended
entries
SYSTEM SUMMARY
TABLE
This sticker will show
all zones location and
all 1 touch

version 1.1
4
SmartBus P900
-
V16
N
NN
N
USER MANUAL
Intelligent Disarm [4-digit Us r Cod ] + [#]
Intelligent Arming [4-digit Us r Cod ] + [#]
Away Arm Hold down [1] for 2 seconds
Day Arm Hold down [2] for 2 seconds
Night Arm Hold down [3] for 2 seconds
Force Arm Hold down [4] for 2 seconds
Turn On/Off Home
Automation Point Hold down [5] for 2 seconds + [HA point numb rs 1 to 8] + [#]
Bypass Security Zone Hold down [6] for 2 seconds + [zon numb rs 1 to 16] + [#]
View System Trouble Hold down [7] for 2 seconds
View Alarm Memory Hold down [8] for 2 seconds
Program Chime Zone Hold down [9] for 2 seconds + [zon numb rs 1 to 16] + [#]
Holiday Mode Arming Hold down [0] for 2 seconds
Activate Fire Alarm Hold down [F] for 2 seconds
Activate Panic Alarm Hold down [P] for 2 seconds
Activate Medical Alarm Hold down [M] for 2 seconds
Turn On/Off Keypad
Buzzer Hold down [MODE] for 2 seconds
R mark:
To enter zone number more than 9, press button [F] to represent the ten’s digit.
e.g. To enter zone number 15, press [F] + [5].
SUMMARY OF OPERATION

version 1.1
5
SmartBus P900
-
V16
N
NN
N
USER MANUAL
PARTITION SYSTEM ENABLED
Intelligent Disarm [4-digit Us r Cod ] + [#] + [Partition 1] or [Partition 2]
Intelligent Arming [4-digit Us r Cod ] + [#] + [Partition 1] or [Partition 2]
Away Arm Hold down [1] for 2 seconds + [Partition 1] or [Partition 2]
Day Arm Hold down [2] for 2 seconds + [Partition 1] or [Partition 2]
Night Arm Hold down [3] for 2 seconds + [Partition 1] or [Partition 2]
Force Arm Hold down [4] for 2 seconds + [Partition 1] or [Partition 2]
Holiday Mode Arming Hold down [0] for 2 seconds + [Partition 1] or [Partition 2]
TESTING THE SYSTEM
Sensor Walk Test [MODE] [1] [#]
CMS Reporting Test [MODE] [2] [#]
Siren Test [MODE] [3] [#]
Strobe Light Test [MODE] [4] [#]
Battery Test [MODE] [5] [#]
SUMMARY OF OPERATION

version 1.1
6
SmartBus P900
-
V16
N
NN
N
USER MANUAL
R mark:
The system will automatically cut off telephone line if the user does not key in any number for more
than 60 seconds or key in wrong master code more than 3 times.
P900
-
V16
N
& GSM MODULE TELEPHONY CONTROL DIAGRAM
Call In to Syst m:
# (T rminat T l phon
R porting Imm diat ly)
2 Forc Arm / Disarm syst m
1 Syst m Voic R port on:
- Alarm trigg r d zon
- Syst m Arm / Disarm
- Zon Op n / Clos / Bypass d
- Sir n On / Off / Fail
- AC pow r status
- Hom Automation On / Off
4 On/Off
Hom
Automation
Point
01 to 08
(HA
Points)
0 (ON /
OFF All
HA
Points)
Dial
Phon
Numb r
Wait for
Answ r
Syst m Call Out:
Syst m
w lcom
not and
voic
m nu
3 On/Off Sir n
01 to 16
(Zon
numb r)
Answ r
Call
5 Bypass/
Unbypass
Zon
[Mast r
Cod ] +
[#]
Slow
b ps
[Mast r
Cod ] +
[#]
0 Bypass/
Unbypass
All Zon s
Syst m
voic
r port
and voic
m nu

version 1.1
7
SmartBus P900
-
V16
N
NN
N
USER MANUAL
USER PROGRAMMING SUMMARY DIAGRAM
ENTER USER
PROGRAMMING
MODE
[
] + [MODE] +
[Master Code] + [#]
Correct code or
step – 2 beeps
Wrong code or
step – 1 long beep
MASTER CODE
Press [01] + [New Code] + [Re-enter New Code] + [#]
PROGRAM C
ODES
USER CODE
Press [02 - 14] + [New Code] + [Re-enter New Code] + [#]
DOOR ACCESS CODE
Press [15] + [New Code] + [Re-enter New Code] + [#]
DURESS CODE
Press [16] + [New Code] + [Re-enter New Code] + [#]
SYSTEM TIME CLOCK
Press [17] + [Timer in 24-hour format] + [#]
PROGRAM SYSTEM CLOCK
SECURITY AUTO ARM/DISARM TIMERS
Press [18 - 21] + [Timer in 24-hour format] + [#]
PROGRAM SECURITY TIMERS
HOME AUTOMATION ON/OFF TIMERS
Press [22- 25] + [Timer in 24-hour format] + [#]
PROGRAM HOME AUTOMATION TIMERS
REPORTING TELEPHONE NUMBER
Press [30 - 31] + [Reporting telephone number] + [#]
PROGRAM REPORTING TELEPHONE NUMBER
EXIT USER PROGRAMMI
NG MODE
Press [MODE] + [#]
EXIT USER PROGRAMMING MODE

version 1.1
8
SmartBus P900
-
V16
N
NN
N
USER MANUAL
Enter User Programming Mode [ Ж ] + [MODE] + [4-digit Master Code] + [#]
Exit User Programming Mode [MODE] + [#]
Program New or Change Existing
Master Code [01] + [New Master Code] + [Re-enter New Master Code] +
[#]
Program New or Change Existing
User Code 2 [02] + [New User Code] + [Re-enter New User Code] + [#]
User Code 3 [03] + [New User Code] + [Re-enter New User Code] + [#]
User Code 4 [04] + [New User Code] + [Re-enter New User Code] + [#]
User Code 5 [05] + [New User Code] + [Re-enter New User Code] + [#]
User Code 6 [06] + [New User Code] + [Re-enter New User Code] + [#]
User Code 7 [07] + [New User Code] + [Re-enter New User Code] + [#]
User Code 8 [08] + [New User Code] + [Re-enter New User Code] + [#]
User Code 9 [09] + [New User Code] + [Re-enter New User Code] + [#]
User Code 10 [10] + [New User Code] + [Re-enter New User Code] + [#]
User Code 11 [11] + [New User Code] + [Re-enter New User Code] + [#]
User Code 12 [12] + [New User Code] + [Re-enter New User Code] + [#]
User Code 13 [13] + [New User Code] + [Re-enter New User Code] + [#]
User Code 14 [14] + [New User Code] + [Re-enter New User Code] + [#]
Program New or Change Existing
Door Access Code [15] +[New User Code] + [Re-enter New User Code] + [#]
Program New or Change Existing
Duress Code [16] + [New User Code] + [Re-enter New User Code] + [#]
R mark
:
All programmed codes must be unique from each other. Duplicate code will be rejected during
user programming mode.
Door Access Code is not a security code. This code cannot ARM/DISARM the security system.
Door Access Code is a special code programmed to control your access system.
USER PROGRAMMING SUMMARY TABLE

version 1.1
9
SmartBus P900
-
V16
N
NN
N
USER MANUAL
Program System Timer
System Clock [17] + [Current Time in 24-hour Format] + [#]
Program Security Timers
Partition 1 Auto Arm Timer [18] + [Partition 1 Security Auto ARM Timer] + [#]
Partition 1 Auto Disarm Timer [19] + [Partition 1 Security Auto DISARM Timer] + [#]
Partition 2 Auto Arm Timer [20] + [Partition 2 Security Auto ARM Timer] + [#]
Partition 2 Auto Disarm Timer [21] + [Partition 2 Security Auto DISARM Timer] + [#]
Program Home Automation Timers
Home Automation Auto ON
Timer 1 [22] + [Home Automation Auto ON Timer 1] + [#]
Home Automation Auto OFF
Timer 1 [23] + [Home Automation Auto OFF Timer 1] + [#]
Home Automation Auto ON
Timer 2 [24] + [Home Automation Auto ON Timer 2] + [#]
Home Automation Auto OFF
Timer 2 [25] + [Home Automation Auto OFF Timer 2] + [#]
R mark: All programmed timer must be in 24-hour format e.g. 7 am = 07 00, 8 pm = 20 00.
Program Reporting Telephone Number
Telephone Number 1 [30] + [Reporting Telephone Number 1] + [#]
Telephone Number 2 [31] + [Reporting Telephone Number 2] + [#]
R mark: Button “P” on the keypad is representing a “PAUSE” key of 5 seconds duration,
Button “M” on the keypad is representing a “ Ж ” key of telephone system.
There are various options for arming the system
a. Partition Arming
b. Away Arming
c. Day Arming
d. Night Arming
. Forc Arming
f. Holiday Arming
g. R mot Control Away Arming
h. Tim r Auto Arming
i. T l phon R mot Arming
For information on how to ARM Partition system, please refer to PARTITIONING THE SYSTEM at
page 17.
ARMING THE SYSTEM
USER PROGRAMMING SUMMARY TABLE

version 1.1
10
SmartBus P900
-
V16
N
NN
N
USER MANUAL
[∗
∗∗
∗] + [USER CODE] + [#]
Leave via ENTRY/EXIT Zone)
1. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
2. Press the [∗
∗∗
∗] key to cancel any unintended entries.
3. Enter a valid 4-digit [USER CODE]. If you enter any mistakes, press [∗
∗∗
∗] key and re-enter
the code followed by [#] key to confirm you command.
4. The P1 indicator will illuminate and the keypad audible indicator will sound on and off for
the duration of the EXIT delay. Any bypassed zones will be shown by the flashing zone
indicators.
5. Leave the premises only via the EXIT/ENTRY zone.
6. During AWAY arming, the telephone line will be supervised hourly. If the telephone line is
disconnected, a new trouble condition will be registered please refer to View System
Trouble at page 13).
7. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
[1]
Press and hold down for 2 seconds)
8. It is also possible to AWAY arm by simply enter and hold down [1] key for 2 seconds.
[2]
Press and hold down for 2 seconds)
1. This arming mode is ideal for DAY time arming with user still remains in the protected
premises.
2. In this mode, the system will be armed instantly with certain preprogrammed, DAY STAY
zones bypassed automatically.
3. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
4. DO NOT open the ENTRY/EXIT zone.
5. Enter and hold down [2] key for 2 seconds.
6. The P1 indicator will illuminate and the keypad audible indicator will sound 2 beeps to
confirm the arming.
7. Any DAY STAY zones will be automatically bypassed shown by flashing zone indicators).
8. User will be given an ENTRY delay time to DISARM the system when enter the protected
premises via ENTRY/EXIT zone.
DAY ARMING
AWAY ARMING

version 1.1
11
SmartBus P900
-
V16
N
NN
N
USER MANUAL
[3]
Press and hold down for 2 seconds)
1. This arming mode is ideal for NIGHT time arming with user still remains in the protected
premises.
2. In this mode, the system will be armed instantly with certain preprogrammed, NIGHT STAY
zones bypassed automatically.
3. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
4. DO NOT open the ENTRY/EXIT zone.
5. Enter and hold down [3] key for 2 seconds.
6. The P1 indicator will illuminate and the keypad audible indicator will sound 2 beeps to
confirm the arming.
7. Any NIGHT STAY zones will be automatically bypassed shown by flashing zone
indicators).
8. There is no ENTRY delay in this arming mode. Any violation on the active zones will trigger
the system instantly.
[4]
Press and hold down for 2 seconds)
1. In this mode, the system will be armed with EXIT delay time which allows certain violated
zones to be bypassed temporary. When the violated zones resume, the zone will be
protected again.
2. Enter and hold down [4] key for 2 seconds.
3. The P1 indicator will illuminate and the keypad audible indicator will sound on and off for
the duration of the EXIT delay. Any bypassed zones will be shown by the flashing zone
indicators.
4. User will be given an ENTRY delay time to DISARM the system when enter the protected
premises via ENTRY/EXIT zone.
[0]
Press and hold down for 2 seconds)
1. This arming mode is ideal for long away occasion holiday).
2. In this mode, the system will be AWAY armed. Home Automation points will be random
ON/OFF every hour to simulate occupancy from 7pm to 1am.
3. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
4. Enter and hold down [0] key for 2 seconds.
FORCE ARMING
HOLIDAY ARMING
NIGHT ARMING

version 1.1
12
SmartBus P900
-
V16
N
NN
N
USER MANUAL
5. The P1 indicator will illuminate and the keypad audible indicator will sound on and off for
the duration of the EXIT delay. Any bypassed zones will be shown by the flashing zone
indicators.
6. Leave the premises only via the EXIT/ENTRY zone.
7. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
8. After disarming, Home Automation random ON/OFF function will be deactivated and the
system will resume to normal Home Automation ON/OFF timers setting.
1. This arming mode is ideal for remote control unit or key-switch arming.
2. The system will arm in AWAY arming mode.
3. The system will be armed with EXIT delay time which allows certain violated zones to be
bypassed temporary. When the violated zones resume, the zone will be protected again.
4. Press the remote control button or twist and release the key-switch.
5. The system will be armed instantly. Leave the premises via ENTRY/EXIT zone.
6. The P1 indicator will illuminate and the keypad audible indicator will sound 2 beeps to
confirm the arming.
7. If programmed to do so, the siren will sound briefly for this remote control arming please
refer to Installer Programming section – system option setting).
8. User will be given an ENTRY delay time to DISARM the system when enter the protected
premises via ENTRY/EXIT zone.
1. Your system can be programmed to automatically ARM itself according to a programmed
schedule.
2. This arming mode will automatically turn to FORCE ARM mode when the system timer
reaches the preset AUTO ARM time.
3. Please refer to User Programming section – Program Auto ARM Timers.
1. Your system can be remotely ARM from outside the house through any normal DTMF
telephone or GSM hand phone.
2. This arming mode will automatically turn to FORCE ARM mode when the user enter a
correct Master Code through Telephone or hand phone.
3. Please refer to Telephone Control Diagram at page 6.
There are various options for disarming the system:
a. Partition Disarming
DISARMING THE SYSTEM
TIMER AUTO ARMING
REMOTE CONTROL ARMING
TELEPHONE REMOTE ARMING

version 1.1
13
SmartBus P900
-
V16
N
NN
N
USER MANUAL
b. K ypad Disarming
c. R mot Control Disarming
d. Tim r Auto Disarming
. T l phon R mot Disarm
For information on how to DISARM Partition system, please refer to PARTITIONING THE SYSTEM
at page 17.
[USER CODE] + [#]
1. To disarm the system, enter a valid 4-digit [USER CODE] followed by [#] key before expiry
of the entry delay time.
2. Enter the premises through a designated ENTRY/EXIT zone; entering via other zones will
trigger an alarm instantly.
3. The ENTRY delay begins once the ENTRY zone is violated.
4. The keypad audible indicator will sound for the duration of the ENTRY delay to indicate that
a valid user code is required.
5. If the P1 indicator remains illuminated, an error has been made while entering the user
code, press [∗
∗∗
∗] key and re-enter the user code.
6. Once the system is disarmed, the P1 indicator will extinguish and the keypad audible
indicator will stop.
7. If no valid user code has been entered by the end of the ENTRY delay period, an ALARM
condition will be registered and stored into the system MEMORY.
8. If programmed to do so, the keypad will be locked and non-responsive for a
preprogrammed period for certain number of incorrect user codes, which are entered
consecutively more than the keypad lock counter.
9. If the ENTRY delay is too short, have your installer to change the ENTRY delay period.
10. If the MEMORY indicator is flashing upon entry, there has been an intrusion. Call for
assistance. The intruder may still be inside.
1. To instantly disarm the system, press the remote control button or twist and release the
key-switch.
2. If the P1 indicator remains illuminated, press the remote control button or twist and release
the key-switch again.
3. The system will be disarmed instantly. The P1 indicator will extinguish and the keypad
audible indicator will sound 2 beeps to confirm the disarming.
4. If programmed to do so, the siren will sound briefly for this remote control disarming.
Please refer to Installer Programming Section – System Option Setting).
1. Your system can be programmed to automatically DISARM itself according to a
programmed schedule.
KEYPAD DISARMING
TIMER AUTO DISARMING
REMOTE CONTROL DISARMING

version 1.1
14
SmartBus P900
-
V16
N
NN
N
USER MANUAL
2. Please refer to User Programming section – Program Auto Disarm Timer.
1. Your system can be remotely DISARM from outside the house through any normal DTMF
telephone or GSM hand phone.
2. This disarming mode will automatically turn off the security system when the user enters a
correct Master Code through Telephone or hand phone.
3. Please refer to Telephone Control Diagram at page 6.
[5] + [HA POINT NUMBERS] + [#]
Press and hold down for 2 seconds) 1 to 8)
1. Enter and hold down [5] key for 2 seconds.
2. The POWER and P1 indicators will slow flash and keypad audible indicator will sound 2
beeps.
3. Zone indicators 1 to 8 will turn ON if the respective HA points are ON.
4. Zone indicators 1 to 8 will turn OFF if the respective HA points are OFF.
5. Enter the HA point numb rs followed by [#] key. Keypad audible indicator will sound 2
beeps to confirm the command and the system will be back to normal mode.
6. To turn On/Off all Home Automation (HA) points at once, enter [0] key followed by [#].
7. Keypad audible indicator will sound 2 beeps to confirm the command and the system will
be back to normal mode.
e.g. To turn ON/OFF HA point 3 and 4:
Press and hold down [5] for 2 seconds + [3] + [4] + [#]
Keypad audible indicator will sound 2 beeps to confirm the command. HA point 3 and 4 will
turn ON.
[6] + [ZONE NUMBERS] + [#]
Press and hold down for 2 seconds) 01 to 16)
1. Enter and hold down [6] key for 2 seconds.
2. The P1 and KEYLOCK indicators will slow flash and keypad audible indicator will sound 2
beeps.
3. Press the zone number that needs to be bypassed, e.g. press [2] if you wish to bypass
zone 2.
4. To enter zone number more than 9, press button [F] to represent the ten’s digit.
5. E.g. To enter zone number 12, press [F] + [2], zone number 16 press [F] + [6].
6. Repeat step 3 to bypass other zones.
7. Press [#] key to exit the bypass mode and keypad audible indicator will sound 2 beeps to
confirm the command.
BYPASS ZONE
TURN ON/OFF HOME AUTOMATION POINT
TELEPHONE REMOTE DISARMING

version 1.1
15
SmartBus P900
-
V16
N
NN
N
USER MANUAL
8. To bypass all zones at once, enter [0] key followed buy [#].
9. Keypad audible indicator will sound 2 beeps to confirm the command and the system will
be back to normal mode.
10. The relevant ZONE indicator will slow flash to indicate that the zone is bypassed now.
11. Zones cannot be bypassed once the system is armed.
12. All bypassed zones will be automatically un-bypassed each time the system is disarmed
and must be reapplied before the next arming.
[6] + [ZONE NUMBERS] + [#]
Press and hold down for 2 seconds) 01 to 16)
1. Enter and hold down [6] key for 2 seconds.
2. The P1 and KEYLOCK indicators will slow flash and keypad audible indicator will sound 2
beeps.
3. Press the zone number corresponding to the current bypassed zone.
4. To enter zone number more than 9, press button [F] to represent the ten’s digit.
5. E.g. To enter zone number 12, press [F] + [2], zone number 16 press [F] + [6].
6. Repeat step 3 to un-bypass other zones.
7. Press [#] key to exit the un-bypass mode and keypad audible indicator will sound 2 beeps
to confirm the command.
8. To unbypass all zones at once, enter [0] key followed buy [#].
9. Keypad audible indicator will sound 2 beeps to confirm the command and the system will
be back to normal mode.
10. The relevant ZONE indicator will extinguish to indicate that the zone is now active.
[7]
Press and hold down for 2 seconds)
1. The system will monitor a number of possible trouble conditions. If one of these conditions
occurs, the SERVICE indicator will turn ON.
2. The SERVICE indicator will still be illuminated until the trouble is restored.
3. Enter and hold down [7] key for 2 seconds.
4. The SERVICE and KEYLOCK indicators will slow flash and keypad audible indicator will
sound 2 beeps.
5. One or more ZONE indicators will turn ON to indicate the troubles occur.
6. Press [#] key to exit and keypad audible indicator will sound 2 beeps.
ZONE 1
indicator AC Loss
ZONE
2
indicator Real Time Clock Loss Program System Timer - refer to page 24)
ZONE 3
indicator Siren Fail
ZONE 4
indicator Battery Low Voltage
ZONE 5
indicator Telephone Line/GSM CMS Reporting Fail
VIEW SYSTEM TROUBLE
UN
-
BYPASS ZON
E

version 1.1
16
SmartBus P900
-
V16
N
NN
N
USER MANUAL
ZONE 6
indicator Telephone Line/GSM Personal Reporting Fail
ZONE 7
indicator Telephone Line Connection Fail
Remark: Zone 1, 2, 3 and 4 indicators will only be extinguished after the troubles are restored.
Zone 5, 6 and 7 indicators will be extinguished when they are viewed once.
[8]
Press and hold down for 2 seconds)
1. The system alarm memory will store the most recent alarm condition. An alarm condition
will cause the MEMORY indicator to slow flash.
2. The MEMORY indicator will extinguish once the user enters VIEW ALARM MEMORY
mode.
3. Enter and hold down [8] key for 2 seconds.
4. The MEMORY indicator will turn ON and keypad audible indicator will sound 2 beeps.
5. One or more ZONE indicators will turn ON to indicate the zones that cause the most recent
alarm.
6. Press [#] key to exit and keypad audible indicator will sound 2 beeps.
The chime mode allows user to monitor nominated zones while the system is disarmed. The
audible indicator will sound briefly when the nominated zone is violated – the siren will NOT sound.
If you wish to know there is someone enters or exits the front door, the keypad will beep once when
the door is opened provided the zone is a chime zone.
[9] + [ZONE NUMBERS] + [#]
Press and hold down for 2 seconds) 01 to 16)
1. Press and hold down [9] key for 2 seconds.
2. The POWER and KEYLOCK indicators will slow flash and keypad audible indicator will
sound 2 beeps.
3. To change any zone to chime zone, just press the key corresponding to that zone. The
zone indicator will illuminate constantly.
4. To enter zone number more than 9, press button [F] to represent the ten’s digit.
5. E.g. To enter zone number 12, press [F] + [2], zone number 16 press [F] + [6].
6. Press [#] key to exit the chime mode and keypad audible indicator will sound 2 beeps to
confirm the command.
e.g. To program zone 3 and zone 4 as CHIME zones:
Press and hold down [9] for 2 seconds + [3] + [4] + [#]
Keypad audible indicator will sound 2 beeps to confirm the command. Zone 3 and 4 are
now CHIME zones.
TO CANCEL CHIME ZONE:
Repeat the above steps and ensure that the zone indicator is extinguished.
FIRE MODE
[F]
Press and hold down for 2 seconds)
EMERGENCY SITUATI
ON
CHIME MODE
VIEW ALARM MEMORY

version 1.1
17
SmartBus P900
-
V16
N
NN
N
USER MANUAL
1. This key will activate the FIRE ALARM condition when it is held down for 2 seconds.
2. The FIRE ALARM condition can also be triggered by an installed smoke detector, which is
set as fire zone.
3. The siren will sound and the FIRE REPORTING CODE will be transmitted to the central
monitoring station.
4. To silence the siren, enter a 4-digit user code followed by [#] key.
PANIC MODE
[P]
Press and hold down for 2 seconds)
1. This key will activate the PANIC ALARM condition when it is held down for 2 seconds.
2. The PANIC ALARM condition can also be activated by any FIXED or REMOTE PANIC
button that has been installed.
3. If the panic button is set as silent zone, then the PANIC REPORTING CODE will be
transmitted to the central monitoring station without the siren sounding. Ensure that your
installer has enabled this function if it is required.
4. To silence the siren, enter a valid 4-digit user code followed by [#] key. If the siren is not
cancelled, it will stop automatically after the SIREN TIME OUT period.
5. Press this key only in an emergency situation that requires response by emergency
personnel.
MEDICAL MODE
[M]
Press and hold down for 2 seconds)
1. This key will activate the MEDICAL ALARM condition when it is held down for 2 seconds.
2. The keypad audible indicator will sound to indicate that a MEDICAL ALARM has been
initiated.
3. The siren will sound and the MEDICAL REPORTING CODE will be transmitted to the
central monitoring station.
4. To silence the siren, enter a 4-digit user code followed by [#] key.
DURESS CODE
1. This is a special 4-digit user code that is only used in the unique situation where an intruder
forces one to disarm the system “under duress”.
2. When the duress code is entered, the control panel will be disarmed. However, a DURESS
REPORTING CODE is transmitted to the central monitoring station to inform them that you
have been forced to disarm the control panel by an intruder.
3. It is advisable to choose a code that can be easily remembered by all family or staff)
members.
Depending on your need, your installer can program your control panel to recognize and control 2
separate areas Partition 1 and Partition 2) by activating the system’s partitioning feature. User
codes can also be programmed to ARM/DISARM one partition or both partitions simultaneously.
You can use partitioning in installations where shared systems are more practical, such as
office/warehouse buildings, or apartment/condominium complexes.
PARTITIONING THE SYSTEM

version 1.1
18
SmartBus P900
-
V16
N
NN
N
USER MANUAL
Zones can be divided into two systems. Based on your requirements, the installer designates which
zones belong to Partition 1 and Partition 2, both partitions dual area), or are not given any partition
assignment. A zone belonging to a 2 partitions is armed only when both Partition 1 and Partition 2
are armed. However, this sharing zone will be disarmed if either Partition 1 or Partition 2 is
disarmed.
The installer must program the required user code settings. These settings determine which user
codes can arm Partition 1, as well as which user codes can arm Partition 2. Codes can also be
given access to both partitions.
If your us r cod has acc ss to both partitions
[*] + [USER CODE] + [#] + [1] + [2]
Leave via ENTRY/EXIT Zone)
1. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
2. Press the [*] key to cancel any unintended entries.
3. Enter a valid 4-digit [USER CODE]. If you enter mistakes, press [*] key and re-enter the
code followed by [#] key to confirm your command.
4. If the key in user code is assigned to control 2 partitions, zone indicators 1 and 2 will flash.
Enter key [1] followed by key [2].
5. The P1 and P2 indicators will illuminate and the keypad audible indicator will sound on and
off for the duration of the EXIT delay. Any bypassed zones will be shown by the flashing
zone indicators.
6. Leave the premises only via the EXIT/ENTRY zone.
7. During AWAY arming, the telephone line will be supervised hourly. If the telephone line is
disconnected, a new trouble condition will be registered please refer to View System
Trouble).
8. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
[1] + [1 or 2]
Press and hold down for 2 seconds)
9. It is also possible to AWAY arm by simply enter and hold down [1] key for 2 seconds.
10. Zone indicator [1] and [2] will flash.
11. Enter key [1] followed by key [2] to both partitions.
If your us r cod has acc ss to 2 partitions and you would lik to arm Partition 1 only
[*] + [USER CODE] + [#] + [1] + [#]
Leave via ENTRY/EXIT Zone)
If your us r cod has acc ss to 2 partitions and you would lik to arm Partition 2 only
[*] + [USER CODE] + [#] + [2] + [#]
Leave via ENTRY/EXIT Zone)
1. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
2. Press the [*] key to cancel any unintended entries.
AWAY ARMING EITHER 1 PARTITION
AWAY ARMING 2 PARTITIONS SIMULTANEOUSLY
ARMING A PARTITIONED SYSTEM

version 1.1
19
SmartBus P900
-
V16
N
NN
N
USER MANUAL
3. Enter a valid 4-digit [USER CODE]. If you enter mistakes, press [*] key and re-enter the
code followed by [#] key to confirm your command.
4. Zone indicator [1] and [2] will flash. Enter the partition number that you wish to arm
followed by [#] key.
5. The P1 indicator will illuminate of Partition 1 is armed.
6. The P2 indicator will illuminate of Partition 2 is armed.
7. The keypad audible indicator will sound on and off for the duration of the EXIT delay. Any
bypassed zones will be shown by the flashing zone indicators.
8. Leave the premises only via the EXIT/ENTRY zone.
9. During AWAY arming, the telephone line will be supervised hourly. If the telephone line is
disconnected, a new trouble condition will be registered please refer to View System
Trouble).
10. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
If your us r cod has acc ss to 1 partition only
[*] + [USER CODE] + [#]
Leave via ENTRY/EXIT Zone)
1. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
2. Press the [*] key to cancel any unintended entries.
3. Enter a valid 4-digit [USER CODE]. If you enter mistakes, press [*] key and re-enter the
code followed by [#] key to confirm your command.
4. The P1 indicator will illuminate if the entered user code is Partition 1 user code.
5. The P2 indicator will illuminate if the entered user code is Partition 2 user code.
6. The keypad audible indicator will sound on and off for the duration of the EXIT delay. Any
bypassed zones will be shown by the flashing zone indicators.
7. Leave the premises only via the EXIT/ENTRY zone.
8. During AWAY arming, the telephone line will be supervised hourly. If the telephone line is
disconnected, a new trouble condition will be registered please refer to View System
Trouble).
9. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
[1] + [1 or 2] + [#]
Press and hold down for 2 seconds)
1. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
2. Enter and hold down key [1] for 2 seconds.
3. Zone indicator [1] and [2] will flash.
4. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key.
5. The P1 indicator will illuminate of Partition 1 is armed.
6. The P2 indicator will illuminate of Partition 2 is armed.
7. Leave the premises only via the EXIT/ENTRY zone.
8. During AWAY arming, the telephone line will be supervised hourly. If the telephone line is
disconnected, a new trouble condition will be registered please refer to View System
Trouble).
9. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
[2] + [1 or 2] + [#]
Press and hold down for 2 seconds)
PARTITION DAY ARMING
FASTKEY AWAY ARMING EITHER 1 PARTITION

version 1.1
20
SmartBus P900
-
V16
N
NN
N
USER MANUAL
1. This arming mode is ideal for DAY time arming with user still remains in the protected
premises.
2. In this mode, system will be armed instantly with certain preprogrammed, DAY STAY
zones bypassed automatically.
3. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
4. DO NOT open the ENTRY/EXIT zone.
5. Enter and hold down key [2] for 2 seconds.
6. Zone indicator [1] and [2] will flash.
7. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key.
8. The P1 indicator will illuminate of Partition 1 is armed.
9. The P2 indicator will illuminate of Partition 2 is armed.
10. Any DAY STAY zones will be automatically bypassed shown by flashing zone indicators).
11. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
[3] + [1 or 2] + [#]
Press and hold down for 2 seconds)
1. This arming mode is ideal for NIGHT time arming with user still remains in the protected
premises.
2. In this mode, system will be armed instantly with certain preprogrammed, NIGHT STAY
zones bypassed automatically.
3. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
4. DO NOT open the ENTRY/EXIT zone.
5. Enter and hold down key [3] for 2 seconds.
6. Zone indicator [1] and [2] will flash.
7. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key.
8. The P1 indicator will illuminate of Partition 1 is armed.
9. The P2 indicator will illuminate of Partition 2 is armed.
10. Any NIGHT STAY zones will be automatically bypassed shown by flashing zone
indicators).
11. There is no ENTRY delay in this arming mode. Any violation on the active zones will trigger
the system instantly.
[4] + [1 or 2] + [#]
Press and hold down for 2 seconds)
1. In this mode, the system will be armed with EXIT delay time which allows certain violated
zones to be bypassed temporary. When the violated zones resume, the zone will be
protected again.
2. Enter and hold down key [4] for 2 seconds.
3. Zone indicator [1] and [2] will flash.
4. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key.
5. The P1 indicator will illuminate of Partition 1 is armed.
6. The P2 indicator will illuminate of Partition 2 is armed.
7. Keypad audible indicator will sound on and off for the duration of the EXIT delay. Any
bypassed zones will be shown by the flashing zone indicators.
8. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
PARTITION FORCE ARMING
PARTITION NIGHT ARMING
Table of contents
Other BLUGUARD Control Panel manuals
Popular Control Panel manuals by other brands

Nilfisk-Advance
Nilfisk-Advance MD421-P manual

Tunstall
Tunstall Flamenco operating instructions

Thermics
Thermics LUNA 2T user manual

Pego
Pego ECP300 EXPERT VD Series Operation and maintenance manual

Honeywell
Honeywell Notifier NFS-320 operating instructions

Panasonic
Panasonic AWRP501 - HYBRID CONTROL PANEL Service manual