BLUGUARD SmartBus P900-T32 Series User manual

1 V1.0
SmartBus P900-T32 Series USER MANUAL
Contents
1.0 INTRODUCTION.................................................................................................................................. 3
2.0 TESTING................................................................................................................................................ 3
3.0 LIMITATIONS...................................................................................................................................... 3
3.1WARNINGS........................................................................................................................................... 3
4.0 GLOSSARY............................................................................................................................................ 4
5.0 SUMMARY OF OPERATION............................................................................................................. 5
6.0 TELEPHONY CONTROL DIAGRAM............................................................................................... 7
7.0 UNDERSTAND YOUR KEYPAD INDICATORS ............................................................................. 8
8.0 USER MENU SUMMARY DIAGRAM............................................................................................... 9
9.0 USER PROGRAMMING SUMMARY TABLE............................................................................... 10
10.0 ARMING THE SYSTEM.................................................................................................................. 13
10.1 AWAY ARMING.................................................................................................................. 13
10.2 DAY ARMING...................................................................................................................... 14
10.3 NIGHT ARMING.................................................................................................................. 14
10.4 FORCE ARMING ................................................................................................................. 15
10.5 HOLIDAY ARMING............................................................................................................ 15
10.6 REMOTE CONTROL ARMING (OPTIONAL)................................................................... 16
10.7 AUTO TIMER ARMING...................................................................................................... 16
10.8 TELEPHONE REMOTE ARMING...................................................................................... 17
11.0 DISARMING THE SYSTEM ........................................................................................................... 17
11.1 KEYPAD DISARMING........................................................................................................ 17
11.2 REMOTE CONTROL DISARMING (OPTIONAL) ............................................................. 18
11.3AUTO TIMER DISARMING ............................................................................................... 18
11.4 TELEPHONE REMOTE DISARMING................................................................................ 18
12.0 TURN ON/OFF HOME AUTOMATION POINT.......................................................................... 19
13.0 BYPASS ZONE.................................................................................................................................. 19
14.0 UN-BYPASS ZONE........................................................................................................................... 20
15.0 VIEW SYSTEM TROUBLE............................................................................................................. 20
16.0 EVENT VIEWER .............................................................................................................................. 21
17.0 CHIME MODE.................................................................................................................................. 22
18.0 VIEW ZONE VOCABULARY SETTING...................................................................................... 22
19.0 VIEW HA POINT VOCABULARY SETTING.............................................................................. 23
20.0 EMERGENCY SITUATION............................................................................................................ 23
21.0 PARTITIONING THE SYSTEM..................................................................................................... 25
22.0 ARMING A PARTITIONED SYSTEM .......................................................................................... 25
22.1 AWAY ARMING 4 PARTITIONS SIMULTANEOUSLY.................................................. 25
22.2 AWAY ARMING EITHER 1 PARTITION.......................................................................... 26
22.3 FASTKEY AWAY ARMING EITHER 1 PARTITION....................................................... 27
22.4 PARTITION DAY ARMING................................................................................................ 28
22.5 PARTITION NIGHT ARMING............................................................................................ 29

2 V1.0
SmartBus P900-T32 Series USER MANUAL
22.6 PARTITION FORCE ARMING ........................................................................................... 29
22.7 PARTITION HOLIDAY ARMING ...................................................................................... 30
23.0 PARTITION DISARMING .............................................................................................................. 30
24.0 USER CODE ...................................................................................................................................... 31
25.0 USER PROGRAMMING MODE .................................................................................................... 32
25.1 ACCESS USER PROGRAMMING MODE ......................................................................... 32
25.2 EXIT USER PROGRAMMING MODE ............................................................................... 32
25.3 PROGRAM NEW AND CHANGING EXISTING MASTER / USER CODE .................... 32
25.4 PROGRAM NEW AND CHANGING EXISTING DURESS CODE .................................. 33
25.5 ERASE USER or DURESS CODE ....................................................................................... 34
25.6 PROGRAM SYSTEM TIMER.............................................................................................. 35
25.7 PROGRAM AUTO ARM PARTITION 1/2/3/4 TIMER...................................................... 35
25.8 TO ERASE AUTO ARM PARTITION 1/2/3/4 TIMER....................................................... 36
25.9 PROGRAM AUTO DISARM PARTITION 1/2/3/4 TIMER................................................ 36
25.10 TO ERASE AUTO DISARM PARTITION 1/2/3/4 TIMER .............................................. 37
25.11 PROGRAM AUTO ON TIMER 1/2/3/4 FOR HOME AUTOMATION............................ 38
25.12 TO ERASE AUTO ON TIMER 1/2/3/4 FOR HOME AUTOMATION............................. 39
25.13 PROGRAM AUTO OFF TIMER 1/2/3/4 FOR HOME AUTOMATION .......................... 39
25.14 TO ERASE AUTO OFF TIMER 1/2/3/4 FOR HOME AUTOMATION ........................... 40
25.15 PROGRAM PERSONAL TELEPHONE NUMBER 1/2/3/4.............................................. 41
25.16 TO ERASE PERSONAL TELEPHONE NUMBER 1/2/3/4............................................... 41
25.17 PROGRAM GSM TELEPHONE NUMBER 1/2/3/4.......................................................... 42
25.18 TO ERASE GSM TELEPHONE NUMBER 1/2/3/4........................................................... 43
25.19 PROGRAM SYSTEM DATE ............................................................................................. 44
26.0 TESTING THE SYSTEM................................................................................................................. 44
26.1 WALK TEST......................................................................................................................... 44
26.2 CMS TEST (Manual Test)..................................................................................................... 45
26.3 SIREN TEST ......................................................................................................................... 45
26.4 STROBE LIGHT TEST......................................................................................................... 45
26.5 BATTERY TEST .................................................................................................................. 45
27.0 PAGE SWITCHING.......................................................................................................................... 46
28.0 SYSTEM INFORMATION............................................................................................................... 47
29.0 SYSTEM SETTING........................................................................................................................... 48

3 V1.0
SmartBus P900-T32 Series USER MANUAL
The BLUGUARD Control Panel is designed for simple operation yet provides the maximum
protection for you. Please read this manual carefully and follow the instructions contained in this
book. Fill in the system information page and store this manual in a safe place for future
reference.
Your security system consists of a main control panel, one or more keypads and home
automation (HA) modules, various sensors and detectors. An enclosure will contain the control
panel, which includes the system electronics and standby battery.
To ensure that your system is functioning, it is important that you test your system weekly. Please
refer to testing procedures section in this manual. If your system does not function properly,
please contact your system installer for services. There is normally no reason for anyone other
than the installer or service professional to have access to the control panel.
Even though BLUGUARD is an advanced security system, it does not 100% guarantee the
protection against burglary, fire or other loses. Any alarm system whether commercial or
residential is subjected to compromise or failure-to-warn for a variety of reasons. These include:
Intruders may gain access through unprotected openings or have the technical
sophistication to bypass an alarm sensor or disconnect an alarm warning device.
Intrusion detectors, smoke detectors and many sensing devices will not operate without
power. Devices powered by AC will not work if there is no AC power supply for any
reason and the back-up battery is missing, dead or improperly installed.
Alarm warning devices such as sirens may not alert people or wake up sleepers if they
are located on the other side of closed or partly closed doors.
Telephone line needed to transmit alarm events from the premise to a central monitoring
station may be out or temporary out of service. Telephone line is subject to compromise
by sophisticated method of attack.
Smoke detector used in conjunction with the alarm system may not sense fire that start
from where smoke cannot reach the detector such as wall, roof or the other side of the
doors. Smoke detector also may not sense a fire on another level of the residence or
building. In general, detectors may not always warn you about fire caused by
carelessness and safety hazards like smoking, violent explosions, escaping gas,
improper storage of flammable material, overloaded electrical circuits, children playing
with matches.
The most common cause of an alarm system not functioning properly when an intrusion
or fire occurs is inadequate maintenance. Therefore, your system should be tested
weekly to ensure all detectors or sensors are working properly.
Installing an alarm system may make you eligible for lower insurance rates but an alarm
system is not a substitute for insurance. Homeowners, property owners and renters
should continue to insure their lives and properties.
A readily accessible disconnect device shall be incorporated external to the
equipment when installation.
No operator’s replaceable batteries provided.
The caution of replacement of battery provided in installation instructions for SERVICE
PERSON.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY INCORRECT TYPE.
CAUTION: DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
The installation instructions require the external protective earthing green/yellow wire
must be at least 0.75mm2/18AWG complying with table 3B.
2.0 TESTING
3.0 LIMITATIONS
Note: All information is subject to changes without prior notice.
3.1 WARNINGS
1.0 INTRODUCTION

4 V1.0
SmartBus P900-T32 Series USER MANUAL
Alarm Memory
This is the history of the most recent violations that occurred the last time
when an alarm was triggered.
Arm
To set the system into the ARMED mode. In this mode, a zone violation will
activate an alarm condition. If the system is programmed accordingly, it will
cause a reporting code to be sent to the central monitoring station.
Bypass
To deactivate zone. When the panel is ARMED, violation of a bypassed zone
will be ignored.
Chime
A short beep sound from the keypad to indicate a zone is violated.
Day Arm
Instant arming that allows for certain preprogrammed, DAY STAY zones to be
violated while the system is armed. In this mode, an ENTRY delay time will be
given to the user to disarm using the keypad after entering the armed
premises.
Day Stay Zone
Zones that are bypassed automatically when the system is DAY ARMED.
Disarm
To deactivate the system. FIRE, PANIC and MEDICAL remain active while
the system is disarmed.
Duress Code
An ambush code which will disarm the system and simultaneously send a
silent distress signal to the central monitoring station.
Entry/Exit Zone
A zone with programmable delay time will allow user to exit the premises after
arming the system and disarm by using the keypad after entering the armed
premises. This zone is generally the last exit point and the first entry point of
the building, i.e. the front door of a house.
Follower Zone
A zone that may be temporary violated during exit delay period or after the
first violation of an ENTRY/EXIT zone. This allows the user access to disarm
the system. A FOLLOWER zone will behave as an instant zone if it is violated
prior to the violation of an ENTRY/EXIT zone.
Force Arm
Arming with exit delay that allows for certain violated zones to be bypassed
temporary. When the violated zones resume, these zones will be protected.
There is an ENTRY delay time in this arming mode.
Home
Automation
(HA)
Optional system expander module that allows you to control different light and
appliances from any keypad, remote telephone, cellular phone. It can also be
programmed to turn on/off light at certain time daily or during alarm condition.
Instant Zone
When the system is armed, any violation of an instant zone will immediately
cause an alarm condition to be registered.
Master Code
Master code is a 4-digit personal identification number that allows you to
enter certain programming mode, arm or disarm the system and remotely
control the system via telephone line.
Night Arm
Instant arming that allows for certain preprogrammed, NIGHT STAY zones to
be violated while the system is armed. In this mode, there is no ENTRY delay
time for the user.
Night Stay Zone
Zones that are bypassed automatically when the system is NIGHT ARMED.
Partitioning
A partitioned system is a single physical security system that provides
independent areas of protection intended for use by independent users.
Remote Control
Arm
Arming with a momentary or latch remote control module. In this mode, it
allows certain violated zones to be bypassed temporary. When the violated
zones resume, the zone will be protected. There is an ENTRY and EXIT
delay time in this arming mode.
User Code
User code is a 4-digit personal identification number that allows you to arm or
disarm the system.
Zone
A specific area of your premises guarded by sensors, which detect violations
of that area.
4.0 GLOSSARY

5 V1.0
SmartBus P900-T32 Series USER MANUAL
System Disarm
[4-digit User Code] + [#]
Intelligent Arming
[4-digit User Code] + [#]
Away Arm
Hold down [1] for 2 seconds
Day Arm
Hold down [2] for 2 seconds
Night Arm
Hold down [3] for 2 seconds
Force Arm
Hold down [4] for 2 seconds
Turn On/Off Home
Automation Point
Hold down [5] for 2 seconds + [HA point number 01 to 32] + [#]
Bypass Security Zone
Hold down [6] for 2 seconds + [Zone number 01 to 32] +[#]
View System Trouble
Hold down [7] for 2 seconds
View Event Log
Hold down [8] for 2 seconds
Program Chime Zone
Hold down [9] for 2 seconds + [Zone number 01 to 32] + [#]
Holiday Mode Arming
Hold down [0] for 2 seconds
Activate Fire Alarm
Hold down [F] for 2 seconds
Turn On/Off
Keypad Buzzer
Press [MODE] +[6] +[#]
On/Off Voice for
Chime Zone
Press [MODE] +[7] +[#]
Activate Panic Alarm
Press [MODE] +[8] + [#]
Activate Medical Alarm
Press [MODE] +[9] + [#]
Page Switching (Zone
1-16 or Zone 17-32)
Press []
Remark:
Press 2-digit number to enter zone number.
Example:
To enter zone number 8, press [0] + [8];
To enter zone number 15, press [1] + [5];
To enter zone number 32, press [3] + [2].
5.0 SUMMARY OF OPERATION

6 V1.0
SmartBus P900-T32 Series USER MANUAL
PARTITION SYSTEM ENABLED
Intelligent Disarm
[4-digit User Code] + [#] +
[Partition 1] or [Partition 2] or [Partition 3] or [Partition 4]
Intelligent Arming
[4-digit User Code] + [#] +
[Partition 1] or [Partition 2] or [Partition 3] or [Partition 4]
Away Arm
Hold down [1] for 2 seconds +
[Partition 1] or [Partition 2] or [Partition 3] or [Partition 4]
Day Arm
Hold down [2] for 2 seconds +
[Partition 1] or [Partition 2] or [Partition 3] or [Partition 4]
Night Arm
Hold down [3] for 2 seconds +
[Partition 1] or [Partition 2] or [Partition 3] or [Partition 4]
Force Arm
Hold down [4] for 2 seconds +
[Partition 1] or [Partition 2] or [Partition 3] or [Partition 4]
Holiday Mode Arming
Hold down [0] for 2 seconds +
[Partition 1] or [Partition 2] or [Partition 3] or [Partition 4]
TESTING THE SYSTEM
Sensor Walk Test
Press : [MODE] + [1] + [#]
or [Menu] [System Tests] [Walk Test]
CMS Reporting Test
Press : [MODE] + [2] + [#]
or [Menu] [System Tests] [CMS Test]
Siren Test
Press : [MODE] + [3] + [#]
or [Menu] [System Tests] [Siren Test]
Strobe Light Test
Press : [MODE] + [4] + [#]
or [Menu] [System Tests] [Strobe Test]
Battery Test
Press : [MODE] + [5] + [#]
or [Menu] [System Tests] [Battery Test]
SUMMARY OF OPERATION (CONT.)

7 V1.0
SmartBus P900-T32 Series USER MANUAL
Remark:
1. The system will automatically cut off telephone line if the user does not key in any number for
more than 60 seconds or key in wrong master code more than 3 times.
2. Master code, User code 2, User code 3 and user code 4 are Telephony remote access codes.
6.0 TELEPHONY CONTROL DIAGRAM6.0 TELEPHONY CONTROL DIAGRAM
Call In to System:Call In to System:
1 System Voice Report
System Call Out:
# (Terminate Telephone
Reporting Immediately)
2 Force Arm / Disarm system
3 On/Off Siren
4 On/Off
Home
Automation
Point
01 to 32
(HA
Points)
00 (On/Off
All HA
Points)
Answer
Call
Slow
beeps
[Master
Code] +
[#]
(Master
Code,
User
Code 2, 3
& 4 are
telephony
control
codes)
System
voice
report
and voice
menu
01 to 32
(Zone
number)
5 Bypass/
Unbypass
Zone
00 Bypass/
Unbypass
All Zones
Dial
Phone
Number
Wait for
Answer
System
welcome
note and
voice
menu
[Master
Code] +
[#]
(Master
Code,
User
Code 2, 3
& 4 are
telephony
control
codes)

8 V1.0
SmartBus P900-T32 Series USER MANUAL
7.0 UNDERSTAND YOUR KEYPAD INDICATORS
ZONE INDICATORS
Indicate the status of
the zones
POWER INDICATOR
The icon is displayed
when AC power is
present
5 TURN ON/OFF HA
POINT
This key will TURN
ON/OFF HA point
when hold down for 2
seconds
ARMED INDICATOR
The armed icon is
displayed when the
system is armed
7 VIEW TROUBLE
This key will activate
the VIEW TROUBLE
mode when hold
down for 2 seconds
8 VIEW ALARM
MEMORY
This key will activate
the VIEW ALARM
MEMORY mode when
hold down for 2
seconds
0 HOLIDAY MODE
This key will activate
HOLIDAY mode when
hold down for 2
seconds
MODE
This key will start the
programming or test
mode command
STAR CANCEL
/PAGE SWITCHING
This key will cancel
any unintended
entries and Page
Switching (Zone 1-16
or Zone 17-32)
Or Exit to the main
menu
9 CHIME MODE
This key will activate
the CHIME mode
when hold down for 2
seconds
HASH ENTER
This key will confirm
all commands entered
to the system
KEYLOCK INDICATOR
The icon is displayed
when the keypad is
locked
MEMORY INDICATOR
The indicator will be
blinking when the alarm
is triggered
1 AWAY ARM
This key will activate
the AWAY ARM mode
when hold down for 2
seconds
2 DAY ARM
This key will activate
the DAY ARM mode
when hold down for 2
seconds
4 FORCE ARM
This key will activate
the FORCE ARM
mode when hold
down for 2 seconds
3 NIGHT ARM
This key will activate
the NIGHT ARM mode
when hold down for 2
seconds
Fire emergency
This key will activate
The fire emergency
Warning
6 BYPASS ZONE
This key will activate
the BYPASS mode
when hold down for 2
seconds
Scroll Up
This key will scroll up
for manual &
Instructions
SERVICE INDICATOR
The icon is displayed
when the system is in
trouble condition
MUTE KEYPAD
SOUND
The icon will be
displayed when
the keypad is
muted.
Scroll Down
This key will scroll
Down for manual &
Instructions
CLOCK
Display Clock

9 V1.0
SmartBus P900-T32 Series USER MANUAL
8.0 USER MENU SUMMARY DIAGRAM
Menu
Zone Info
Zone 1 –32 vocabulary setting
HA Point Info
HA Point 1 –32 vocabulary setting
Mute Keypad
User Mode
Enter Code + [#]
Passwords
PROGRAM CODE
Master Code 01
User Code 02 - 31
Duress Code
Clock
PROGRAM CLOCK
Clock
Timers
PROGRAM TIMER
Arm P1 Timer
Disarm P1 Timer
Arm P2 Timer
Disarm P2 Timer
Arm P3 Timer
Disarm P3 Timer
Arm P4 Timer
Disarm P4 Timer
ON HA Timer 1
OFF HA Timer 1
ON HA Timer 2
OFF HA Timer 2
ON HA Timer 3
OFF HA Timer 3
ON HA Timer 4
OFF HA Timer 4
Tel Nos
PROGRAM TEL NO
User Tel No 1
User Tel No 2
User Tel No 3
User Tel No 4
GSM Tel No 1
GSM Tel No 2
GSM Tel No 3
GSM Tel No 4
Date
PROGRAM DATE
Date
Installer Mode
Enter Code + [#]
Software Info
System Tests
Walk Test
CMS Test
Siren Test
Strobe Test
Battery Test

10 V1.0
SmartBus P900-T32 Series USER MANUAL
Access User Programming Mode : [] + [MODE] + [4-digit Master Code] + [#] OR
Access from LCD Menu
Exit User Programming Mode : [] / Exit from LCD Menu
Program New or Change Existing
Password
Master Code 01
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 02
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 03
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 04
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 05
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 06
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 07
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 08
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 09
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 10
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 11
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 12
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 13
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 14
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 15
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 16
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 17
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 18
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 19
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 20
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 21
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 22
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 23
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 24
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 25
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
9.0 USER PROGRAMMING SUMMARY TABLE

11 V1.0
SmartBus P900-T32 Series USER MANUAL
User Code 26
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 27
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 28
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 29
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 30
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
User Code 31
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
Duress Code
Key in [New User Code] + [#]
[Re-confirm New User Code] + [#]
Remark:
1. Master code, User Code 2,User Code 3 and User Code 4 are telephone remote
access codes. These codes can ARM/DISARM the security system via local keypad or
via telephone remote access.
Program System Timer
Clock
Real Time Clock
Key in time [0000 to 2359] + [#]
[F # to erase the previous setting]
Program Security Timers
Timers
Arm P1 Timer
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
Disarm P1 Timer
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
Arm P2 Timer
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
Disarm P2 Timer
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
Arm P3 Timer
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
Disarm P3 Timer
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
Arm P4 Timer
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
Disarm P4 Timer
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
Program Home Automation Timers
Timers
ON HA Timer 1
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
OFF HA Timer 1
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
ON HA Timer 2
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
OFF HA Timer 2
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
ON HA Timer 3
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
OFF HA Timer 3
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
ON HA Timer 4
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]
OFF HA Timer 4
Key in time [0000 to 2359] + [#]
[F# to erase the previous setting]

12 V1.0
SmartBus P900-T32 Series USER MANUAL
Remark: All programmed timer must be in 24-hour format e.g. 7 am = 07 00, 8 pm = 20 00.
Program Reporting Telephone Numbers
Tel No’s
User Tel No: 1
Key in [16 digit Tel No.] + [#]
[F to erase the previous setting]
User Tel No: 2
Key in [16 digit Tel No.] + [#]
[F to erase the previous setting]
User Tel No: 3
Key in [16 digit Tel No.] + [#]
[F to erase the previous setting]
User Tel No: 4
Key in [16 digit Tel No.] + [#]
[F to erase the previous setting]
GSM Tel No: 1
Key in [16 digit Tel No.] + [#]
[F to erase the previous setting]
GSM Tel No: 2
Key in [16 digit Tel No.] + [#]
[F to erase the previous setting]
GSM Tel No: 3
Key in [16 digit Tel No.] + [#]
[F to erase the previous setting]
GSM Tel No: 4
Key in [16 digit Tel No.] + [#]
[F to erase the previous setting]
Remark: Button “▲” on the keypad is representing a “PAUSE” key of 5 seconds duration,
Button “▼” on the keypad is representing a “” key of telephone system.
Program System Date
Date
Current Date
[DD/MM/YY] + [#]
[F # to erase the previous setting]

13 V1.0
SmartBus P900-T32 Series USER MANUAL
There are various options for arming the system
a. Partition Arming
b. Away Arming
c. Day Arming
d. Night Arming
e. Force Arming
f. Holiday Arming
g. Remote Control Arming
h. Timer Auto Arming
i. Telephone Remote Arming
For information on how to ARM Partition system, please refer to Partitioning The System at
page 25 (Section 21.0).
[] + [USER CODE] + [#]
(Leave via ENTRY/EXIT Zone)
1. Ensure that all zone indicators are extinguished; if not, check that all protected premises
are closed.
2. Press [] key to cancel any unintended entries.
3. Enter a valid 4-digit [USER CODE]. If you enter any mistakes, press []key and re-enter
the code followed by [#] key to confirm you command.
4. will be displayed.
5. An EXIT delay countdown timer will be shown at the top right temporarily replace the
clock and the keypad audible indicator will sound on and off for the duration of the EXIT
delay.
6. Any bypassed zones will be shown by the flashing zone underline.
7. Leave the premises only via the EXIT/ENTRY zone.
8. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
9. It is also possible to AWAY arm by simply press and hold down key [1] for 2 seconds.
[1]
(Press and hold down for 2 seconds)
10.0 ARMING THE SYSTEM
10.1 AWAY ARMING

14 V1.0
SmartBus P900-T32 Series USER MANUAL
[2]
(Press and hold down for 2 seconds)
1. This arming mode is ideal for DAY time arming with user still remains in the protected
premises.
2. In this mode, the system will be armed instantly with certain preprogrammed, DAY STAY
zones bypassed automatically.
3. Ensure that all zone indicators are extinguished; if not, check that all protected premises
are closed.
4. DO NOT open the ENTRY/EXIT zone.
5. Press and hold down key [2] for 2 seconds.
6. icon will be displayed
7. The keypad audible indicator will sound 2 beeps to confirm the arming.
8. Any DAY STAY zones will be automatically bypassed which shown by flashing zone
underline.
9. User will be given an ENTRY delay time to DISARM the system when enter the protected
premises via ENTRY/EXIT zone.
[3]
(Press and hold down for 2 seconds)
1. This arming mode is ideal for NIGHT time arming with user still remains in the protected
premises.
2. In this mode, the system will be armed instantly with certain preprogrammed, NIGHT
STAY zones bypassed automatically.
3. Ensure that all zone indicators are extinguished; if not, check that all protected premises
are closed.
4. DO NOT open the ENTRY/EXIT zone.
5. Press and hold down key [3] for 2 seconds.
6. icon will be displayed
7. The keypad audible indicator will sound 2 beeps to confirm the arming.
10.2 DAY ARMING
10.3 NIGHT ARMING

15 V1.0
SmartBus P900-T32 Series USER MANUAL
8. Any NIGHT STAY zones will be automatically bypassed which shown by flashing zone
underline.
9. There is no ENTRY delay in this arming mode. Any violation on the active zones will
trigger the system instantly.
[4]
(Press and hold down for 2 seconds)
1. In this mode, the system will be armed with EXIT delay time which allows certain violated
zones to be bypassed temporary. When the violated zones resume, the zone will be
protected again.
2. Press and hold down key [4] for 2 seconds.
3. icon will be displayed
4. An EXIT delay countdown timer will be shown at the top right temporarily replace the
clock and the keypad audible indicator will sound on and off for the duration of the EXIT
delay.
5. Any bypassed zones will be shown by the flashing zone underline.
6. User will be given an ENTRY delay time to DISARM the system when enter the protected
premises via ENTRY/EXIT zone.
[0]
(Press and hold down for 2 seconds)
1. This arming mode is ideal for long away occasion (holiday).
2. In this mode, the system will be AWAY armed. Home Automation points will be random
ON/OFF every hour to simulate occupancy from 7pm to 1am.
3. Ensure that all zone indicators are extinguished; if not, check that all protected premises
are closed.
4. Press and hold down key [0] for 2 seconds.
5. icon will be displayed.
10.4 FORCE ARMING
10.5 HOLIDAY ARMING

16 V1.0
SmartBus P900-T32 Series USER MANUAL
6. An EXIT delay countdown timer will be shown at the top right temporarily replace the
clock and the keypad audible indicator will sound on and off for the duration of the EXIT
delay.
7. Any bypassed zones will be shown by the flashing zone underline.
8. Leave the premises only via the EXIT/ENTRY zone.
9. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
10. After disarming, Home Automation random ON/OFF function will be deactivated and the
system will resume to normal Home Automation ON/OFF timers setting.
1. This arming mode is ideal for remote control unit or key-switch arming.
2. The system will arm in FORCE arming mode.
3. The system will be armed with EXIT delay time which allows certain violated zones to be
bypassed temporary. When the violated zones resume, the zone will be protected again.
4. Press the remote control button or twist and release the key-switch.
5. The system will be armed instantly. Leave the premises via ENTRY/EXIT zone.
6. icon will be displayed.
7. An EXIT delay countdown timer will be shown at the top right temporarily replace the
clock and the keypad audible indicator will sound 2 beeps to confirm the arming.
8. If programmed to do so, the siren will sound briefly for this remote control arming (please
refer to Installer Programming Section –System Option Setting).
9. User will be given an ENTRY delay time to DISARM the system when enter the protected
premises via ENTRY/EXIT zone.
1. Your system can be programmed to automatically ARM itself according to a programmed
schedule.
2. This arming mode will automatically turn to FORCE ARM mode when the system timer
reaches the preset AUTO ARM time.
3. Please refer to Program Auto Arm Partition 1/2/3/4 Timer at page 35 (Section 25.7).
10.6 REMOTE CONTROL ARMING (OPTIONAL)
10.7 AUTO TIMER ARMING

17 V1.0
SmartBus P900-T32 Series USER MANUAL
1. Your system can be remotely ARM from outside the house through any normal DTMF
telephone or GSM hand phone.
2. This arming mode will automatically turn to FORCE ARM mode when the user enter a
correct Master Code through Telephone or hand phone.
3. Please refer to Telephony Control Diagram at page 7 (Section 6.0).
There are various options for disarming the system:
a. Partition Disarming
b. Keypad Disarming
c. Remote Control Disarming
d. Timer Auto Disarming
e. Telephone Remote Disarm
For information on how to DISARM Partition system, please refer to Partition Disarming at page
30 (Section 23.0).
[USER CODE] + [#]
1. To disarm the system, enter a valid 4-digit [USER CODE] followed by [#] key before
expiry of the entry delay time.
2. Enter the premises through a designated ENTRY/EXIT zone; entering via other zones will
trigger an alarm instantly.
3. The ENTRY delay begins once the ENTRY zone is violated.
4. The keypad audible indicator will sound for the duration of the ENTRY delay to indicate
that a valid user code is required.
5. If the icon remains displayed, an error has been made while entering the user code.
Press []key and re-enter the user code.
6. An ENTRY delay countdown timer will be shown at the top right temporarily replace the
clock.
7. Once the system is disarmed, the icon will extinguish and the keypad audible
indicator will stop.
10.8 TELEPHONE REMOTE ARMING
11.0 DISARMING THE SYSTEM
11.1 KEYPAD DISARMING

18 V1.0
SmartBus P900-T32 Series USER MANUAL
8. If the icon is flashing upon entry there has been an intrusion. Call for assistance. The
intruder may still be inside.
9. If no valid user code has been entered by the end of the ENTRY delay period, an
ALARM condition will be registered and stored into the system MEMORY.
10. If programmed to do so, the keypad will be locked and non-responsive for a
preprogrammed period for certain number of incorrect user codes, which are entered
consecutively more than the keypad lock counter.
11. If the ENTRY delay is too short, have your installer to change the ENTRY delay period.
1. To instantly disarm the system, press the remote control button or twist and release the
key-switch.
2. The icon will extinguish and the keypad audible indicator will sound 2 beeps to
confirm the disarming.
3. If programmed to do so, the siren will sound briefly for this remote control disarming
(Please refer to Installer Programming Section –System Option Setting).
1. Your system can be programmed to automatically DISARM itself according to a
programmed schedule.
2. Please refer to Program Auto Disarm Partition 1/2/3/4 Timer at page 36 (Section 25.9).
1. Your system can be remotely DISARM from outside the house through any normal DTMF
telephone or GSM hand phone.
2. This disarming mode will automatically turn off the security system when the user enters
a correct Master Code through Telephone or hand phone.
3. Please refer to Telephony Control Diagram at page 7 (Section 6.0).
11.2 REMOTE CONTROL DISARMING (OPTIONAL)
11.3 AUTO TIMER DISARMING
11.4 TELEPHONE REMOTE DISARMING

19 V1.0
SmartBus P900-T32 Series USER MANUAL
[5] + [HA POINT NUMBERS] + [#]
(Press and hold down for 2 seconds) (01 to 32)
1. Press and hold down key [5] for 2 seconds.
2. The screen will show “HA Info” and keypad audible indicator will sound 2 beeps.
Zone 1 to 32 will be displayed if the respective HA points are ON.
Zone 1 to 32 will not be displayed if the respective HA points are OFF.
3. Enter the HA point numbers followed by [#] key. Keypad audible indicator will sound 2
beeps to confirm the command and the system will be back to normal mode.
4. To turn On/Off all Home Automation (HA) points at once, press key [00] followed by [#].
5. Keypad audible indicator will sound 2 beeps to confirm the command and the system will
be back to normal mode.
[6] + [ZONE NUMBERS] + [#]
(Press and hold down for 2 seconds) (01 to 32)
1. Press and hold down key [6] for 2 seconds.
2. The screen will show “Bypass Info” and keypad audible indicator will sound 2 beeps.
3. Press the zone number that needs to be bypassed, e.g. press [02] + [12] + [16] if you
wish to bypass zone 2, 6 and 16.
4. Press [#] key to exit the bypass mode and keypad audible indicator will sound 2 beeps to
confirm the command.
5. To bypass all zones at once, press key [00] followed by [#].
6. The relevant ZONE underline will slow flash to indicate that the zone is bypassed now.
12.0 TURN ON/OFF HOME AUTOMATION POINT
13.0 BYPASS ZONE
To turn ON/OFF HA point 3 and 4:
Press and hold down [5] for 2 seconds + [03] + [04] + [#].
Keypad audible indicator will sound 2 beeps to confirm the
command. HA point 3 and 4 will turn ON/OFF.

20 V1.0
SmartBus P900-T32 Series USER MANUAL
7. Zones cannot be bypassed once the system is armed.
8. All bypassed zones will be automatically un-bypassed each time the system is disarmed
and must be reapplied before the next arming.
[6] + [ZONE NUMBERS] + [#]
(Press and hold down for 2 seconds) (01 to 32)
1. Press and hold down key [6] for 2 seconds.
2. The screen will show the Bypass Zones and keypad audible indicator will sound 2 beeps.
3. Press the zone number corresponding to the current bypassed zone e.g. press [02] +
[12] + [16] if you wish to un-bypass zone 2, 6 and 16.
4. Press [#] key to exit the bypass mode and keypad audible indicator will sound 2 beeps to
confirm the command.
5. To un-bypass all zones at once, press key [00] followed by [#].
6. Keypad audible indicator will sound 2 beeps to confirm the command and the system will
be back to normal mode.
7. The relevant ZONE indicator will extinguish to indicate that the zone is now active.
[7]
(Press and hold down for 2 seconds)
1. The system will monitor a number of possible trouble conditions. If one of these
conditions occurs, the icon will display until the trouble is restored.
2. Press and hold down key [7] for 2 seconds.
14.0 UN-BYPASS ZONE
15.0 VIEW SYSTEM TROUBLE
Table of contents
Other BLUGUARD Control Panel manuals