Bogen NQ-GA400P Operating manual

Specications are subject to change.
© Copyright 2022, Bogen Communications LLC
740-00157B 220209
NQ-GA400P 2-Channel AoIP Gateway
Installation and Use Guide
The NQ-GA400P is a 2-channel audio over IP (AoIP) encoder/decoder (i.e., gate-
way) incorporating two balanced line-level inputs and two balanced line-level
outputs, along with two Form-C SPDT-type 2-amp dry contact relays. Designed to
operate over a 10/100 Ethernet network, the NQ-GA400P AoIP Gateway is IEEE
802.3af–compliant and can be powered using Power over Ethernet (PoE). The
NQ-GA400P AoIP Gateway can provide two balanced line-level analog audio out-
puts to auxiliary power ampliers and can accept two balanced line-level analog
inputs from auxiliary preamplier outputs.
Notice
Every effort was made to ensure that the information in this manual was complete and accurate at the time of print-
ing; however, all information is subject to change.
This equipment is not suitable for use in locations where children are likely to be present.
Equipment is intended for use only in a restricted access area.
WARNING: To reduce the risk of re or electric shock, do not expose this apparatus to rain or moisture.
Avertissement: pour réduire le risque d’incendie ou de choc électrique, ne pas exposer cet appareil sous la pluie et
l’humidité.
The apparatus shall not be exposed to dripping or splashing and no objects lled with liquids, such as vases, shall
be placed on apparatus.
L’appareil ne doit pas être exposé aux écoulements ou aux éclaboussures et aucun objet ne contenant de liquide, tel
qu’un vase, ne doit être placé sur l’objet.
The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, ta-
ble-cloths, curtains, etc.
- il convient que l’aération ne soit pas gênée par l’obstruction des ouvertures d’aéra
No naked ame sources, such as lighted candles, should be placed on the apparatus.
- il convient de ne pas placer sur l’appareil de sources de flammes nues, telles que des bougies allumées
The apparatus should be used in moderate climates.
- si l’appareil est destiné à être utilisé sous un climat tempéré.
+
-
G G
+
-
N C CO M N O
LI N E
O U TP U T 1
LI N E
O U TP U T 2
+
-
G G
+
-
LI N E
IN P U T 1
LI N E
IN P U T 2
N C CO M N O
RE L A Y 1 RE L A Y 2

2
NQ-GA400P
Important Safety Information
WARNING: To reduce the risk of re or electric shock, do not expose this apparatus to rain or moisture.
Always comply with the following basic safety precautions when installing and using the unit:
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Clean only with dry cloth.
6. DO NOT install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including ampli-
ers) that produce heat.
7. DO NOT defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with
one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade, or
the third prong, are provided for your safety. If the provided plug does not t into your outlet, consult an electri-
cian for replacement of the obsolete outlet.
8. Protect the power cord from being walked on and/or pinched, particularly at plugs, convenience receptacles,
and the point where they exit from the apparatus.
9. Only use attachments/accessories that are specied by the manufacturer.
10. Unplug this apparatus during lightning storms or when unused for long periods of time.
11. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in
any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
WARNING:
The apparatus shall be connected to a mains socket outlet with a protective
earthing connection.
To reduce the risk of re or electric shock, do not expose this apparatus to
rain or moisture.
The apparatus shall not be exposed to dripping or splashing and no objects
lled with liquids, such as vases, shall be placed on the apparatus.
Where the mains plug or an appliance coupler is used as the disconnect de-
vice, the disconnect device shall remain readily operable.

3
NQ-GA400P
Installation
To install the NQ-GA400P AoIP Gateway:
1. If desired, attach an auxiliary preamplier to the NQ-GA400P AoIP Gateway using pins 1 and 2 of the pluggable
balanced LINE INPUT connector, taking note of the marked polarity (+/−). The G shield terminal can be used, if
necessary.
2. If desired, attach auxiliary amplifers to the NQ-GA400P AoIP Gateway using pins 1 and 2 of the pluggable bal-
anced LINE OUTPUT 1 or 2 connectors, taking note of the marked polarity (+/−). The G shield terminal can be
used, if necessary.
3. Connect a Cat5-type cable into the module’s Ethernet port and ensure the other end of the cable is correctly
connected to a PoE switch port on your network.
4. To connect a device to the NQ-GA400P AoIP Gateway Relay 1 or Relay 2 Form-C dry contact 2A relays, do one of
the following:
a. If the device is congured as normally open, connect to the device using the NO and COM terminals.
b. If the device is congured as normally closed, connect to the device using the NC and COM terminals.
5. If using a 48-V power supply, connect the PS4815W 48-VDC power supply to the module.
Viewing and Understanding LEDs
Two LEDs appear on the front of the amplier chassis. One is labeled POWER and appears
as solid red during initial power up, ashes green during a boot sequence, and appears solid
green when fully booted.
The STATUS LED uses the following indicators to provide information about the module:
• Flashing red: No network connection found.
• Solid blue: The amplifer is in an uninitialized state and is not associated to a server. (The server may be in a
discovery mode.)
• Solid green: The amplifer is registered to a Nyquist server and is in normal operation.
• Flashing green: The amplifer has an IP address but is not registered with the Nyquist server.
• Solid red: The amplifer needs to be rebooted or reset so that the Nyquist application can resume.
+
+
--
G
G
G
G
+
+
--
NNCCCCOOMMNNOO
L
L
I
I
N
N
E
E
O
O
U
U
T
T
P
P
U
U
T
T
1
1
L
L
I
I
N
N
E
E
O
O
U
U
T
T
P
P
U
U
T
T
2
2
+
+
--
G
G
G
G
+
+
--
L
L
I
I
N
N
E
E
I
I
N
N
P
P
U
U
T
T
1
1
L
L
I
I
N
N
E
E
I
I
N
N
P
P
U
U
T
T
2
2
NNCCCCOOMMNNOO
R
R
E
E
L
L
A
A
Y
Y
1
1
R
R
E
E
L
L
A
A
Y
Y
2
2
To balanced input
of auxiliary amplifier
Use shielded cable.
Aux Preamplifer
From output of auxiliary
preamplifier. Use shielded
cable.
Aux Amplifier

4
NQ-GA400P
• Flashing blue: The amplifer is updating.
Using the Reset Button
The Reset button allows you to restart the amplifer or to reset the amplier’s conguration settings
to the factory default settings.
For more information about resetting conguration settings, refer to the NQ-GA400P Conguration
Guide.
Temperature Indicator
In addition to the LEDs that appear on the actual appliance, a separate temperature status indicator appears on the
module’s web-based user interface. For more information, refer to the NQ-GA400P Conguration Guide.
Compliance
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.

5
NQ-GA400P
Limited Warranty, Exclusion of Certain Damages
The NQ-GA400P is warranted to be free from defects in materials and workmanship for ve (5) years from the date
of sale to the original purchaser. Any part of the product covered by this warranty that, with normal installation and
use, becomes defective (as conrmed by Bogen upon inspection) during the warranty period will be repaired or
replaced by Bogen, at Bogen’s option, with new or refurbished product, provided the product is shipped insured and
prepaid to: Bogen Factory Service Department: 4570 Shelby Air Drive, Suite 11, Memphis, TN 38118, USA. Repaired
or replacement product(s) will be returned to you freight prepaid. This warranty does not extend to any of our prod-
ucts that have been subjected to abuse, misuse, improper storage, neglect, accident, improper installation or have
been modied or repaired or altered in any manner whatsoever, or where the serial number or date code has been
removed or defaced.
THE FOREGOING LIMITED WARRANTY IS BOGEN’S SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASER’S
SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR
IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE
HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW. Bogen’s liability arising
out of the manufacture, sale or supplying of products or their use or disposition, whether based upon warranty,
contract, tort or otherwise, shall be limited to the price of the product. IN NO EVENT SHALL BOGEN BE LIABLE
FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROF-
ITS, LOSS OF DATA OR LOSS OF USE DAMAGES) ARISING OUT OF THE MANUFACTURE, SALE OR SUPPLYING OF
PRODUCTS, EVEN IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES. Some
States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you. This warranty gives you specic legal rights, and you may also have other rights
which vary from State to State.
Products that are out of warranty will also be repaired by Bogen Factory Service Department -- same address as
above or call 201-934-8500, at owner’s expense. Returned products which do not qualify for warranty service may
be repaired or replaced at Bogen’s option with a previously repaired or refurbished items. The parts and labor in-
volved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department. All parts
and labor charges as well as shipping charges will be at the owner’s expense.
All returns require a Return Authorization number. For most ecient warranty or repair service, please include a
description of the failure.
1/2019
Other manuals for NQ-GA400P
1
Table of contents
Other Bogen Gateway manuals