-4- -5-
*The automatic setting of the limit function must be performed in mode 1; It's freely to set the upper limit or lower limit
firstly; If there is no limits, the motor will be jog running, or press UP or DOWN button 2S, then the motor will be
continuous running; After the limits have been set, the motor will be continuously running.
1 Manually set upper limit
Press UP for 2S, operate the motor to desired
upper position, press and hold UP and STOP
buttons simultaneously for 2S (2 jogs and 3 beeps),
upper limit is set.
Press UP for 2S,the motor will run upward and
stop after detecting obstacle, the stop position is
the upper limit; then the motor will run downward
automatically and stop after detecting the obstacle,
the curtain is pulled in reverse according to the
weight of the bottom beam, after the tension is
applied, the motor stops here and is the lower limit.
→
UP UP STOP
+
2 Manually set lower limit
Press DOWN for 2S,operate the motor to desired
lower position, press and hold DOWN and STOP
buttons simultaneously for 2S (2 jogs and 3 beeps),
lower limit is set.
STOP
→
DOWN DOWN
+
3 Setting Upper and Lower Limits
4 Automatically set upper limit, manually set lower limit3 Automatic limits setting
UP
Press UP for 2S,the motor will run upward and stop
after detecting the obstacle, the stop position is the
upper limit; then the motor will run downward
automatically to the desired lower position, press and
hold DOWN and STOP buttons simultaneously for 2S
(2 jogs and 3 beeps), the lower limits has been set
→
UP DOWN STOP
+
4 Add A Preferred Position
1 Set preferred position
P2
→ →
P2
STOP STOP
Check both upper and lower limits are set. Operate
the product to desired preferred position. Press P2
(1 jog and 1 beep), press STOP(1 jog and 1 beep),
STOP again (2 jogs and 3 beeps), the preferred
position is set.
2 Remove preferred position
P2
→ →
P2
STOP STOP
Press P2 (1 jog and 1 beep), press STOP(1 jog and
1 beep), STOP again (1 jog and long beep once), the
preferred position is deleted.
*Press STOP for 2S,the motor moves to preferred position automatically; In the automatic return function state, at the
return limit position of the lower limit position, want to press STOP to run to preferred position,the motor will first run
to the lower limit position, this action is to release ofthe curtain, and then run to preferred position.
*This must be done in mode 1; after entering the limit fine adjusting status 2MIN, if no new limits are set , then the
motor will exit the limit fine adjusting status and remain the old limits.
5 Adjust Limits
1 Adjusting the upper limit position
2 Adjusting the lower limit position
→ → →
STOPUP DOWNUP
or
+
STOPUP
+
The new upper
limit position
Press and hold UP and STOP buttons simultaneously for 5S (1 jog and long beep once), operate the
product to desired new upper limit position, press and hold UP and STOP buttons simultaneously for 2S
(2 jogs and 3 beeps), the new upper limit is programmed successfully.
Press and hold DOWN and STOP buttons simultaneously for 5S (1 jog and long beep once), operate the
product to desired new lower limit position, press and hold DOWN and STOP buttons simultaneously for 2S
(2 jogs and 3 beeps), the new lower limit is programmed successfully.
DOWN STOP
+
DOWN STOP
+
DOWNUP
or
→ → →
The new lower
limit position
6 Activate / Deactivate Jog / Tilt Mode
*It must be done after setting the upper limit and the lower limit.
DOWN
→
STOPUP
+Press and hold UP and DOWN buttons simultaneously for 5S (1 jog),
press STOP (1 jog and long beep once), Jog / tilt mode is activated.
If motor jogs twice and beeps 3 times, Jog / tilt mode is deactivate.
• Repeat same procedure will unpair additional emitter.
*(a) as existing emitter, (b) as new emitter to pair/unpair.
7 Pair / Unpair Additional Emitter
P2 P2
→ →
P2
P2(a) P2(a) P2(b)
Press P2 (1 jog and 1 beep) and P2 (1 jog and 1 beep) on existing
emitter, press P2 on new emitter to add (2 jogs and 3 beeps), new
emitter is paired to the motor.
Method one
Press P2 (1 jog and 1 beep) and P2 (1 jog and 1 beep) on existing
emitter, press STOP on new emitter for 2S to add (2 jogs and 3 beeps),
new emitter is paired to the motor.
Method two
P2 P2
→ →
P2(a) P2(a) STOP(b)
Press P1 button for 2S (1 jog), release button and long beep once,
press STOP on new emitter for 2S to add (2 jogs and 3 beeps), new
emitter is paired to the motor.
Method three
STOP(b)
→
P1
P1
→ →
8 Remove All Emitters
P2
P2
P2
P2
STOP
→ →
P2
P2
P2
P2
DOWN
9 Deleting All Limits
*After deleting all emitters, keep the original limit information.
*This operation is deleted along with the preferred position.
Press P2 (1 jog and 1 beep), STOP (1 jog and 1 beep), and P2 (2 jogs
and 3 beeps), all emitters are deleted.
Press P2 (1 jog and 1 beep), DOWN (1 jog and 1 beep), and P2 (2 jogs
and 3 beeps), all limits are removed.
→ →
10 Motor Mode Switching
P2
P2
*Factory default mode 1 motor;
Mode 1 motor is applied to the zib screen motor with no self-locking structure, can automatically set the limit and
automatically adjust the limit 50 times, without the automatic return function of the lower limit;
Mode 2 motor is equipped with zib screen motor with self-locking structure, and automatic return function for lower
limit (automatic locking and unlocking).
Press P2 (1 jog and 1 beep), UP(1 jog and 1 beep), UP again (1 jog
and long beep once), switch to mode 1 motor. If motor jogs twice and
beeps 3 times, switch to mode 2 motor.
UP UP
STOP
11 Motor Lower Limit Return Function
DOWN
→ →
P2
P2
Press P2 (1 jog and 1 beep), STOP(1 jog and 1 beep), and DOWN
(1 jog and long beep once), motor turns on automatic debugging and
return function. If motor jogs twice and beeps 3 times, motor turns on
manual debugging and return function.
*It can only be done when the motor is under mode 2; The factory default motor turns on automatic debugging and
return function.