Bosch CET4-20 Assembly instructions

1
-E/F/S-190609
IMPORTANT: IMPORTANT : IMPORTANTE:
Read Before Using Lire avant usage Leer antes de usar
Operating/Safety Instructions
Consignes de fonctionnement/sécurité
Instrucciones de funcionamiento y seguridad
Call Toll Free for Pour obtenir des informations Llame gratis para
Consumer Information et les adresses de nos centres obtener información
& Service Locations: de service après-vente, para el consumidor y
appelez ce numéro gratuit ubicaciones de servicio
For English Version Version française Versión en español
See page 2 Voir page 17 Ver la página 32
1-877-BOSCH99 (1-877-267-2499) www.boschtools.com
CET4-20W
CET3-10
CET4-20

2
Work AreA
Keep your work area clean and well lit.
Cluttered
benches and dark areas increase the risks of
accidents, electric shock, re, and injury to persons.
Do not operate compressor in explosive atmospheres,
such as in the presence of ammable liquids, gases,
or dust. Keep work area well ventilated. Always locate
the compressor at least 20 ft. (6.1 m) away from work
area if spraying ammable materials. DO NOT SMOKE
if spraying ammable materials.
The compressor is
able to create sparks which may ignite the dust or
fumes. Never use the compressor in sites containing
lacquer, paint, benzene, thinner, gasoline, gases,
adhesive agents, and other materials which are
combustible or explosive. A longer hose may be
required.
Always operate the compressor in a well ventilated
area. Follow all safety instructions and use a respirator
as directed in the safety instructions provided with
the material to be sprayed.
Some sprayed materials
such as paint, paint solvents, paint remover,
insecticides, weed killers, etc contain harmful vapors
and poisons.
Keep bystanders, children, and visitors away while
operating a compressor. Do not allow children to
operate compressor.
Distractions may cause loss
of control of the tools which may cause injury to
bystanders.
Never engage in horseplay with the compressor.
Respect the compressor as a working implement.
Always operate the compressor from a stable secure
position. Never operate the compressor from a roof or
table.
Use additional air hose to allow tools to reach
high locations.
Equip the work area with a suitable re extinguisher.
PersonAl sAfety
Do not remove, tamper with, or otherwise cause
the tool operating controls to become disabled or
inoperable.
This will cause the tool to work irregularly
and may result in the risk of injury.
Dress properly. Do not wear loose clothing or
jewelry. Contain long hair. Keep your hair, clothing,
and gloves away from moving parts.
Loose clothes,
jewelry, or long hair can be caught in moving parts
and increases the risk of injury.
Always wear eye and ear protection when using this
tool. Use additional personal protective equipment
as appropriate when operating this tool.
Operators
and others in work area must wear safety glasses.
Prolonged exposure to high intensity noise is able
to cause hearing loss. Dust mask, non-skid safety
shoes, hard hat and other personal protective
equipment, must be used for appropriate conditions.
Do not operate the compressor unless you are familiar
with controls.
Users unfamiliar with controls may
operate compressor in an unsafe manner, injuring
themselves or others.
Keep handles and controls dry, clean and free from oil
and grease.
Slippery hands cannot safely control the
tool.
Stay alert. Watch what you are doing, and use
common sense when operating a compressor. Do not
use compressor while tired or under the inuence of
drugs, alcohol, or medication.
A moment of inattention
while operating the compressor may result in serious
personal injury.
Do not direct air stream at people or animals.
High
pressure air can propel dust and debris at high
speed. Compressed air from a compressor
can contain water, oil, metal particles or other
contaminants which can cause serious injury.
Do not use compressed air for breathing or
respiration. Never inhale air directly from compressor
or from breathing apparatus connected to compressor.
Compressed air stream may contain carbon
monoxide, toxic vapors or solid particles from air tank
which if inhaled could cause serious injury or death.
Use care when touching exposed metal surfaces of
compressor.
Many components such as compressor
head, engine/motor, and tubing will remain hot even
after the air compressor has been shut down. Allow
compressor to cool before moving or attempting
maintenance.
Do not stand on compressor. Keep proper footing
and balance at all times.
Proper footing and
balance enable better control of tools in unexpected
situations.
Make sure air hose is free of snags and obstructions.
Do not attach an air hose or tool to your body.
GenerAl sAfety rules
All users and employers/owners must read and understand all instructions in this manual before
operating or maintaining this compressor.
Failure to follow all instructions listed below may
result in electric shock, re, serious personal injury or death.
sAVe tHese InstruCtIons
DANGER

3
Entangled or snarled hoses can cause a loss of
balance or footing in addition to unintentional tool
operation. Attach the hose to the structure to reduce
the risk of loss of balance if the hose shifts.
Do not abuse the air hose. Protect all hoses from
kinks, restrictions, solvents or sharp objects. Keep air
hose away from heat, oil, sharp edges or moving parts.
Replace damaged hoses immediately. Damaged
hoses can burst or whip around work area.
Only use hoses with a minimum rating of 200 PSI.
Use
of hoses with a high pressure rating reduce the risk
of injury from a hose bursting.
Firmly grasp hose in hand when installing hoses.
If
hose is not held rmly or correctly installed, hose may
whip and injure personnel in the operating area.
Use care when lifting and carrying the compressor.
Some compressors are too heavy to be lifted by one
person. Get assistance before attempting to lift a
compressor to reduce the risk of injury.
When moving or loading a wheeled compressor ensure
that the compressor is always on a level surface.
If the
compressor is placed on a sloped surface, it may
move unexpectedly and result in personal injury.
This product contains chemicals, including lead,
known to the State of California to cause birth defects
and other reproductive harm.
Wash hands after
using.
tool use And CAre
Use this compressor and all accessories in accordance
with the instructions.
Compressor and accessories
must be used for the purpose for which they are
designed. Use of the compressor for operations
other than what is described in this manual can result
in a hazardous situation.
Use only accessories that are recommended by
BOSCH for your particular model.
Accessories that
may be recommended for a particular model tool
may not be suitable on other model tools and may
result in personal injury.
Before each use, inspect all ttings, hoses, pipes,
connections of the compressor. Do not operate if any
portion of the compressor is loose, missing, damaged,
malfunctioning, disconnected or altered. Never use
a compressor that appears damaged or is operating
abnormally.
If the compressor appears to be
operating unusually and/or making strange noises,
stop using it immediately and contact your local
BOSCH service center. There is a risk of bursting if
the compressor is damaged.
Before each use inspect compressor for signs of leaks
or damage. If leaks are found in the compressor pump,
air tanks or tubing, replace compressor immediately.
Never attempt repair leaks, weld or make
modications to the air tank or other uid conning
parts as there is a risk of bursting.
Do not attempt to operate this air compressor without
rst verifying the oil level in the crankcase. This
compressor is shipped with oil in the crankcase.
Serious damage of the compressor can result from
even momentary operation without proper lubrication.
Never operate the compressor without the safety
valve. Verify operation of the safety valve on a daily
basis. Do not use the safety valve for complete tank
drainage.
The safety valve is designed to relieve tank
pressure to reduce the risk of bursting.
Never operate compressor without all guards and
other safety features in place and performing intended
function.
If maintenance or servicing requires removal
of guard or safety feature, be sure to replace the
guard or safety feature before resuming operation of
the compressor. Replace damaged guards or safety
features immediately.
Never touch moving parts.
Do not place any part of
your body near compressor moving parts. Do not
reach around guards to reduce the risk of injury.
Do not operate compressor without the air lter.
Filters prevent large particles from entering the
air stream and damaging compressor internal
components.
Do not allow particulates such as sawdust to fall into
crankcase when crankcase is open for inspection.
Particulates in oil may reduce compressor life.
Do not use a detergent oil in crankcase.
Detergent
oils will leave deposits on internal compressor
components reducing compressor life and
components.
Do not use compressor for unattended operation.
Always remain in area when compressor is operating
and turn off compressor when not in use to reduce
the risk of re.
Never place objects on top or next to compressor.
Locate compressor at least 12 in. (30 cm) away from
all obstructions.
Restricting any of the compressor’s
ventilation openings can cause overheating and
could cause a re.
Do not operate the compressor with any power source
other than that specied in the tool operating/safety
instructions.
Use of alternative power sources may
result in malfunctions of the compressor and the
power source which may lead to serious injury of you
or others in your surroundings.
Follow all recommendations for sizes of hoses, ttings

4
and other compressed air accessories.
Improperly
sized tting or components may result in the risk of
injury or property damage
Never move the compressor by pulling on a hose.
The
compressor, air ttings and the air hose may become
damaged and burst.
Check air supply lines for restrictions before adjusting
tool.
Air volume is as important as air pressure.
Restricted air ow will prevent the tools from
operating as designed.
Never exceed the maximum allowable pressure
rating marked on tools and attachments. Do not use
compressor to inate low pressure objects such
as toys.
Exceeding the maximum recommended
pressure of tools and attachments can cause them
to burst. The correct pressure is the lowest pressure
that will do the job.
Drain condensate from air tanks daily with drain valve.
Draining water from the air compressor reduces the
risk of air tank corrosion. Corroded air tanks increase
the risk of bursting.
Stop the compressor, drain air tanks and allow it
to cool before making adjustments, moving the
compressor, leaving the work area, performing
maintenance or storing the compressor.
Such
precautionary safety measures reduce a risk of
injury.
Do not modify this compressor or operate compressor
at pressures or speeds greater than designed
.Any
alteration or modication is a misuse and may result
in a dangerous condition such as re or bursting.
When transporting compressor, keep level and place
on a protective mat. Do not place compressor on
its side.
Such precautions reduce the risk of re or
danger to personnel from oil fumes.
serVICe
Maintenance performed by unauthorized personnel
may result in misplacing of the internal components
which could cause serious hazard.
We recommend
that all compressor service be performed by a
BOSCH factory service center or authorized BOSCH
service station.
Develop a periodic maintenance schedule for your
tool. When cleaning a compressor be careful not to
disassemble any portion of the tool since internal
components may be misplaced or safety components
may be improperly mounted.
Certain cleaning agents
such as gasoline, carbon tetrachloride, ammonia, etc.
may damage plastic parts and o-rings.
When servicing the compressor, use only
recommended BOSCH replacement parts. Follow
instructions in the Maintenance section of this
manual.
Use of unauthorized parts or failure to follow
Maintenance Instructions can cause a risk of injury.
Replace missing or damaged warning labels.
Refer to
schematic for correct placement and part number.
Maintain compressor with care. Keep the compressor
clean and lubricated.
Properly maintained tools are
less likely to break and cause injury. Any alteration
or modication is a misuse and may result in a
dangerous condition. Clean the tool at least daily and
lubricate as required.
When not in use, store the compressor out of reach
of children and other personnel unfamiliar with
compressor operation.
When not in use, the tool
should be disconnected and stored in a dry place.
Vent the air tank. Keep out of reach of children. Lock
the storage area. Compressor can be dangerous in
the hands of users unfamiliar with its operation.

5
sAfety rules for eleCtrIC ComPressors
Power cord plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
tools. Unmodied plugs and matching outlets will
reduce risk of electric shock.
Avoid body contact with earthed or grounded
surfaces such as pipes, radiators, ranges and
refrigerators. There is an increased risk of electric
shock if your body is earthed or grounded.
Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges or
moving parts. Replace damaged cord immediately.
Damaged or entangled cords increase the risk of
electric shock.
Do not expose this compressor to rain. Do not
use in damp or wet locations. Moisture increases
the risk of electric shock with this equipment.
Do not touch plug with wet hands. Moisture
increases the risk of electric shock with this
equipment.
Keep all electrical connections dry and off the
ground. Do not allow electrical connections
to lay in water or in such a position where
water could come into contact with cord and
connection. Moisture increases the risk of electric
shock with this equipment.
When operating a power tool outdoors, use an
extension cord suitable for outdoor use and with
correct amperage capacity. Use of a cord rated for
outdoor use reduces the risk of electric shock.
Always disconnect compressor from power
supply, vent air tanks, and allow compressor to
cool before servicing. Compressors with automatic
pressure controls can restart at any time.
Always turn off the motor when not in use and
before moving compressor. Stopping the motor
prevents unintentional starting of the compressor.
Some dust created by power sanding, sawing,
grinding, drilling, and other construction
activities contains chemicals known to cause
cancer, birth defects or other reproductive harm.
Some examples of these chemicals are:
• Lead from lead-based paints,
• Crystalline silica from bricks and cement and other
masonry products, and
• Arsenic and chromium from chemically treated
lumber.
Your risk from these exposures varies, depending on
how often you do this type of work. To reduce your
exposure to these chemicals: work in a well ventilated
area, and work with approved safety equipment, such
as those dust masks that are specially designed to
lter out microscopic particles.
sAVe tHese InstruCtIons

6
funCtIonAl desCrIPtIon And sPeCIfICAtIons
Specications: CET3-10
Product Size: 16” x 18” x 16.25”
Weight: 57.3 lbs.
HP: 1
CFM @ 100 psi: 2.6
RPM: 1700
dBA: 72
Recovery Time: 14 seconds
Motor: 4-Pole Induction
Drive Type: Direct
Maintenance: Oil
Specications: CET4-20
Product Size: 16.25” x 17.75” x 19.75”
Weight: 72.7 lbs.
HP: 2
CFM @ 100 psi: 4.2
RPM: 3400
dBA: 80
Recovery Time: 12 sec.
Motor: 2-Pole Induction
Drive Type: Direct
Maintenance: Oil
5
8
11
14
16
96
17
13
15
2
4
3
12
10
7
1
5
8
11
14
16
36
17
13
15
2
4
9
12
10
7
1

7
1. Warning Label
2. Pressure Switch
3. Pump Discharge Line
4. Oil Dipstick
5. Air Compressor Pump
6. Thermal Overload
7. Pump Oil Fill Port
8. Pump Oil Drain
9. Air Filter
10. Check Valve
11. Electric Power Cord
12. Safety Release Valve
13. Pressure Gauge - Tank Psi
14. Pressure Regulator
15. Pressure Gauge - Outlet Psi
16. Outlet Fittings
17. Tank Drain Valve
Specications: CET4-20W
Product Size: 22” x 21.5” x 19.75”
(handle down)
Weight: 84.9 lbs.
HP: 2
CFM @ 100 psi: 4.9
RPM: 3400
dBA: 80
Recovery Time: 10 sec.
Motor: 2-Pole Induction
Drive Type: Direct
Maintenance: Oil
5
8
11
14
16 3
6
17
13
15 2
4
9
10
7
1
12
funCtIonAl desCrIPtIon And sPeCIfICAtIons

8
Assembly / InstAllAtIon
lubrICAtIon And oIl
Do not attempt to operate this air
compressor without first verifying
the oil level in the crankcase. This compressor is
shipped with oil in the crankcase. Serious damage
of the compressor can result from even momentary
operation without proper lubrication.
Prior to each use, verify the crankcase oil level. An
oil sight gauge with minimum and maximum oil level
marks is provided with this compressor.
Always verify that the oil level is at the maximum
mark in the oil sight gauge before operating this
unit. Do not operate the pump with an inadequate or
excessive amount of oil. The cost of failures which
occur due to incorrect oil levels will not be covered
under warranty.
To check the oil level: (see Fig. 1)
1. Place unit on a level surface.
2. Remove dipstick, wipe with a clean rag, replace
in crankcase, then remove dipstick to inspect oil
level.
3. Ifoil levelis low,addasrequired, butdonot exceed
maximum oil level.
CAUTION
Do not allow particulates such as
sawdusttofallintocrankcasewhen
crank case is open for inspection. Particulates in oil
may reduce compressor life.
CAUTION
Do not use a detergent oil in
crankcase. Detergent oils will leave
deposits on internal compressor components
reducing compressor life and performance.
dIreCtIons for InstAllInG WHeels
(Cet4-20W only See Fig. 2)
1. Take wheel spindle (A) and thread into wheel
bracket (B), which is welded to compressor frame.
Tighten spindle with wrench to secure to frame.
2. Slide wheel onto wheel spindle. Ination stem for
wheelassemblyshouldfacetowardthecompressor
frame.
3. Place screw through washer (D) and thread screw
into end of wheel spindle (C). Tighten screw to
secure to spindle.
4. Repeat these steps for second wheel.
GroundInG
This product must be grounded. In the event of an
electrical short circuit, grounding reduces the risk
of electric shock by providing an escape wire for
the electric current. This product is equipped with
a cord having a grounding wire with an appropriate
grounding plug. The plug must be inserted into an
outlet that is properly installed and grounded in
accordance with all local codes and ordinances (see
Fig. 3).
WARNING
Improper installation of the
grounding plug is able to result in
a risk of electric shock. When repair or replacement
of the cord or plug is required, do not connect the
grounding wire to either flat blade terminal. The wire
with insulation having an outer surface that is green
with or without yellow stripes is the grounding wire.
Check with a qualied electrician or serviceman
when the grounding instructions are not completely
understood, or when in doubt as to whether the
product is properly grounded. Do not modify the plug
provided; if it does not t the outlet, have the proper
outlet installed by a qualied electrician.
CAUTION
Fig. 1
MAX
MIN
Fig. 2
(A)
(B)
(D)
(C)
GROUNDING
PIN
GROUNDED
OUTLET
GROUNDED
OUTLET BOX
Fig. 3

9
This product is for use on a nominal 120-V circuit and
has a grounding plug similar to the plug illustrated on
page 8. Only connect the product to an outlet having
the same conguration as the plug. Do not use an
adapter with this product.
extensIon Cords
Use only a 3-wire extension cord that has a 3-blade
grounding plug, and a 3-slot receptacle that accepts
the plug on the product. Make sure your extension
cord is not damaged. When using an extension cord,
be sure to use one heavy enough to carry the current
your product draws.
RECOMMENDED SIZES OF EXTENSION CORDS
The maximum recommend cord length is 50 feet with
a 12 gauge cord rating.
PrePArAtIon for use
WARNING
Use this compressor and all
accessories in accordance with
the instructions. Compressor and accessories
must be used for the purpose for which they are
designed. Use of the compressor for operations
other than what is described in this manual can result
in a hazardous situation.
eleCtrIC motor
Initial Set-Up – Break-in Procedure
Before rst use of this air compressor or after the
compressor pump/motor has been replaced, perform
the following:
1. Ensure the power switch is in the OFF position.
This air compressor has an integrated power and
pressure switch. When the power is ON the pressure
switch will automatically start the compressor motor
any time the tank pressure drops below the factory
set cut-in pressure and stop the motor when the tank
pressure stops at the factory set cut-out pressure.
2. Ensuresafetyvalveisfunctioningproperlybypulling
on the valve ring and allow the valve to reset (see
Fig. 4).
The safety valve is designed to protect against high
pressure by releasing high pressure air from the air
tank when its factory set pressure (slightly higher
than the pressure switch cut-out setting) is exceeded.
WARNING
If the safety release valve vents
under normal operating
conditions, stop using the compressor
immediately. Send your compressor for service. If
the safety release valve is venting the tanks the
pressure switch may need factory adjustment.
3. Plug the power cord into the correct branch circuit
receptacle.
See the “Grounding Section” for more information on
the correct receptacle.
4. Open the drain valve to permit air to escape the
tank and prevent air pressure build up during the
break-in period.
The drain valve is located on the control panel and
is used to drain condensation from the tanks at the
end of each use. Tank pressure is used to expel the
water.
5. Move the power switch to the ON position. The
compressor will start.
6. Run the compressor for 20 minutes.
7. After 20 minutes, close the drain valve. The tank
will ll to cut-out pressure and the compressor
motor will stop.
8. Move the power switch to the OFF position and
unplug the compressor.
9. Pull the safety valve and allow to vent until tank
pressure is under 20 psi.
10. Open the drain valve to permit air to escape the
tank and to drain any moisture or particles from
tank. When tank is empty, close drain.
11. Compressor is now ready for rst use.
CAUTION
Change the crankcase oil after the
first 50 hours of operation and as
recommended in the maintenance section of this
manual. Failure to change oil according to
maintenance schedule will reduce compressor life
and performance.
Assembly / InstAllAtIon
Extension Cord Table
0 – 25 ft 25 – 50 ft.
14 ga. 12 ga.
Fig. 4

10
stArtInG tHe ComPressor
1. Position compressor on a at surface or one with
an inclination of 10° or less, in a well ventilated
area away from vapors.
2. Ensure all covers and labels are in place, legible
(for labels) and securely mounted. Do not use
compressor until all items have been veried.
3. Ensure the power switch is in the OFF position.
4. Plug the power cord into the correct branch circuit
receptacle. See the “Grounding Section” for more
information on the correct receptacle.
5. Ensure drain valve is closed in the horizontal
position (A).
The drain valve is located at the base of the control
panel and is used to drain condensation from the
tanks at the end of each use. Tank pressure is used
to expel the water.
6. Ensuresafetyvalveisfunctioningproperlybypulling
on the valve ring and allow the valve to reset.
WARNING
If the safety valve vents under
normal operating conditions, stop
using the compressor immediately and send
your compressor for service. If the safety valve is
venting the tanks the pressure switch may need
factory adjustment.
7. Check pump oil level.
CAUTION
Do not operate without oil or with
inadequate oil. Low oil levels may
damage the compressor pump.
8. Attach hoses to compressor (B).
9. TurnthepowertoON,andverifythatthecompressor
is functioning. Adjust the air pressure the desired
level for the accessory as described in adjusting
regulator (C). Verify that the compressor motor
stops when cut out pressure is reached.
motor tHermAl Cut out
The thermal protector operates to stop the motor
when a problem such as a motor overload, etc.
occurs. If the motor should stop during operation,
proceed as follows:
1. Turn the pressure switch lever to the OFF position
and disconnect the plug from the receptacle.
2. If the extension cord does not conform to the
specications given on page 9, replace with an
extensioncordsuchasthatshownonpage9.Ifthe
capacity of the power supply is insufcient, increase
the power supply capacity to remove the cause of
a ow of excessive current (over-current).
3. Waitapproximately5minutes,thenpressthereset
switch (A) of the thermal protector (see Fig. 6).
4. Start the compressor. If the motor still stops during
operation, please contact the service center.
Hot surfACes
WARNING
Use care when touching exposed
metal surfaces of compressor.
Many components such as compressor head,
engine/motor, and tubing will remain hot even after
the air compressor has been shut down. Allow
compressor to cool before moving or attempting
maintenance.
oPerAtIon
Reset
Switch (A)
Fig. 6
Fig. 5
Drain Valve (A)
Regulator (C)
1/4” Outlet
fittings (B)
CET3-10 CET4-20 and
CET4-20W

11
AdjustInG reGulAtor
This compressor is provided with an internal regulator
that controls the output pressure of two female quick
connect couplers. Regulated pressure will be equal
to or less than tank pressure depending on user
setting.
To adjust regulated pressure (see Fig. 7):
1. Pull regulator knob out (A).
2. To increase pressure, turn clockwise.
3. To decrease pressure, turn counter clockwise.
4. Whendesiredpressure isset,pushregulator knob
in to lock pressure.
5. Regulated pressure gauge is displayed as (B).
ConneCtInG AIr suPPly
WARNING
Firmly grasp the hose in hand
when installing hoses. If hose is
not held firmly or correctly installed hose may whip
and injure personnel in the operating area.
INSTALLING HOSES (See Fig. 8):
1. Graspthe hoseatthequickconnect plugandpush
the plug into the quick connect body. Coupler will
snap into place.
2. Grasp the hose and pull to ensure coupler is
seated.
oPerAtInG temPerAtures
Operating temperatures are between 32°F and 104°F
(0°C and 40°C). If operating outside recommended
temperatures, unit may have difculity starting and
will cause additional wear on components.
WARNING
Disconnect the compressor from
the power source, drain air tanks
and allow it to cool before making adjustments,
moving the compressor, leaving the work area,
performing maintenance or storing the
compressor. Such precautionary safety measures
reduce the risk of injury.
sHuttInG doWn tHe ComPressor
1. Move On/Off switch to the OFF position.
2. Turn regulator until outlet pressure gauge reads
0 psi.
3. Remove hose and assembly. See disconnecting
air supply below.
4. Drainairfromtheairtanksbyreleasingairbypulling
the safety release valve.
5. Oncetheairtankpressureisunder20psi,openthe
drain valve on the control panel to drain moisture
from the tanks (See draining tanks on page 12).
6. Allow the compressor to cool down before
storing.
dIsConneCtInG AIr suPPly
DISCONNECTING HOSES (See Fig. 8)
1. Ensure regulated pressure gauge reads 0 psi
(0 kPa).
2. Pullcoupler onquick connectbody backtorelease
quick connect plug on hose.
oPerAtIon
Fig. 7
Regulator (A)
Regulated Pressure
Gauge (B)
Fig. 8

12
WARNING
Maintenance performed by
unauthorized personnel may
result in misplacing of the internal components
which could cause serious hazard. We
recommend that all compressor service be performed
by a BOSCH factory service center or authorized
BOSCH service station.
Your air compressor requires periodic maintenance
according to the maintenance schedule outlined on
the next page, in order to keep your compressor in
peak condition.
Use a soapy water solution to inspect compressor
for leaks. If leaks are found in the compressor pump,
air tanks or tubing, replace compressor immediately.
Never attempt repair leaks, weld or make
modications to the air tank or other uid conning
parts as there is a risk of bursting.
To check the air lter, unscrew the air lter from the
compressor and visually inspect. If the lter appears
to be clogged, replace the lter. After inspection screw
the air lter back on the compressor (See Fig. 9).
serVICe
CHANGING OIL (See Fig. 10):
1. Make sure the pump is cool to avoid burn risk.
2. Take out the oil dipstick (A).
3. Prepare a suitablecontainer tocapture the oil from
the crankcase.
4. Remove crankcase drain plug (B) and allow used
oil to drain in the container.
5. Replace drain plug.
6. Return oil to recycling center or dispose of in
accordance with local regulations.
7. Rell crankcase with fresh oil. Fill oil until it reads
to maximum level of oil dipstick.
8. Replace oil dipstick (A).
Contact your BOSCH service center for instructions
and user replaceable parts. For all other repairs
contact your BOSCH service center.
drAInInG tAnks
1. Place the compressor on a level surface.
WARNING
Ensure that the compressor is on
a level surface. If compressor is not
level, water will not drain from tanks causing
corrosion, which may cause the tanks to burst.
2. Ifpressureisgreaterthan20psi,usesafetyrelease
valve to reduce tank pressure.
WARNING
Do not open drain valve with
pressure greater than 20 psi in
tanks. Such precautionary measures reduce the risk
of injury.
3. Ensurethatnopersonnelareinthedraindischarge
area in front of compressor.
WARNING
Do not direct air stream at people
or animals. High pressure air can
propel dust and debris at high speed. Compressor air
from the compressor can contain water, oil, metal
particles, or other contaminants which can cause
serious injury.
4. Turn drain valve on control panel 90°
counterclockwise. When empty, close valve.
oPerAtIon
mAIntenAnCe
Fig. 9
Fig. 10
MAX
MIN (B)
(A)

13
mAIntenAnCe
CleAnInG
WARNING
When cleaning a compressor be
careful not to disassemble any
portion of the tool since internal components
may be misplaced or safety components may be
improperly mounted.
Certain cleaning agents such as gasoline, carbon
tetrachloride, ammonia, etc. may damage plastic
parts and o-rings.
Periodically clean the compressor tool with soapy
water and a damp cloth.
storAGe
When not in use, the compressor should be
disconnected and stored in a warm and dry place.
Coil the electric cord and place within frame for
protection.
WARNING
When not in use, store the
compressor out of reach of
children and other personnel unfamiliar with
compressor operation. Lock the storage area.
Compressor can be dangerous in the hands of users
unfamiliar with its operation.
loAdInG/unloAdInG
WARNING
Use care when lifting and carrying
the compressor. Some
compressors are too heavy to be lifted by one
person. Get assistance before attempting to liff
compressor to reduce the risk of injury.
Recommendation Daily Weekly Every 200 hours
Check for proper oil level(s) and oil leaks X
Drain moisture from tanks daily or after each use X
Ensure all safety guards are correctly and securely attached X
Clean the cooling surfaces of the compressor X
Inspect air intake lter X
Check safety valves by pulling on rings X
Check system for air leaks X
Change pump oil X
Replace air lter X
If unit is operated in an excessively dirty or dusty area, increase the frequency of all scheduled maintenance
items.

14
PROBLEM SYMPTOMS RESOLUTION
Excessive air tank
pressure – safety
valve pops off
Pressure switch does not• shut of motor when com-
pressor reaches cut-out
pressure
Pressure switch cut-out• too high
Set the On/Off switch to Off, if the unit• does not shut off contact a Bosch fac-
tory service center or a Bosch authorized
service center
Contact a Bosch factory service center or• a Bosch authorized service center
Air leaks Tube fittings are not tight• enough Tighten fittings where air can be heard• escaping. Check fittings with soapy water
solution. Do not overtighten.
Air leaks in air tank or
at air tank welds Defective air tank• Air tank must be replaced. Do not repair• the leak
Warning:• Risk of bursting. Do not drill
into, weld or otherwise modify air tank or
it will weaken. The air tank can rupture or
explode.
Air leaks between
head and valve plate Leaking seals• Contact a Bosch factory service center or• a Bosch authorized service center
Air leaks from safety
valve Defective safety valve• Operate safety valve manually by pull-• ing on ring. If valve still leaks, it must be
replaced.
Knocking noise Defective safety valve•
Pump oil is low•
Carbon build-up in pump•
Operate safety valve manually by pull-• ing on ring. If valve still leaks, it must be
replaced.
Add no-detergent oil to pump.•
Contact a Bosch factory service center or• a Bosch authorized service center
Pressure reading on
the regulated pressure
gauge drops when an
accessory is used
Regulator is not adjusted • correctly for accessory
being used
It is normal for some pressure drop to•
occur when an accessory is used, adjust
the regulator.
Note:• Adjust the regulated pressure
under flow conditions while accessory is
being used.
trouble sHootInG
This section provides a list of the more frequently encountered malfunctions, their causes and corrective
actions. The operator or maintenance personnel can perform some corrective actions, and others may
require the assistance of a qualied Bosch technician or your dealer.

15
Compressor is not
supplying enough
air to operate
accessories
Prolonged excessive use of• air
Compressor is not large• enough for accessory
Hole in air hose•
Check valve restricted•
Air leaks•
Restricted air intake filter•
Decrease amount of air usage.•
Check the accessory air requirement. If• it is higher than the SCFM or pressure
supplied by your air compressor, a larger
compressor is needed to operate acces-
sory.
Replace air hose.•
Remove, clean or replace•
Tighten fittings.•
Clean or replace air intake filter.•
Regulator knob
has continuous air
leak
Regulator is damaged• Replace.•
Regulator will not
shut off air outlet Regulator is damaged• Replace.•
Moisture in pump
crankcase Unit operating in damp or• humid conditions
Detergent type oil being used• in pump
Move unit to a dry well-ventilated area.•
Drain oil and refill with non detergent oil.•
trouble sHootInG

16
Motor will not run Check valve restricted•
Motor overload protection• switch has tripped
Extension cord is wrong• length or gauge
Loose electrical connections•
Possible defective motor or• starting capacitor
Paint spray on internal motor• parts.
Fuse blown, circuit breaker• tripped
Tank pressure exceeds pres-• sure switch cut-in pressure
Pressure release valve on• pressure switch has not un-
loaded head pressure
Remove, clean or replace•
See Motor Overload under Features.•
Check proper gauge wire and cord• length. See Extension Cords under pg. 9.
Contact a Bosch factory service center• or a Bosch authorized service center.
Contact a Bosch factory service center• or a Bosch authorized service center.
Contact a Bosch factory service center• or a Bosch authorized service center.
Do not operate the compressor in the
paint spray area. See flammable vapor
warning.
1. Check fuse box for blown fuse and replace
as necessary. Reset circuit breaker. Do
not use a fuse or circuit breaker with higher
rating than that specied for your particular
branch circuit.
2. Check for proper fuse. Use only a time de-
lay fuse.
3. Check for low voltage conditions and/or
proper extension cord.
4. Disconnect the other electrical appliances
from circuit or operate the compressor on
its own branch circuit.
Motor will start automatically when tank• pressure drops below cut-in pressure of
pressure switch.
Set the On/Off switch to OFF. If the• valve does not open, replace switch.
Contact a Bosch factory service center
or a Bosch authorized service center.
trouble sHootInG

17
esPACe de trAVAIl
Gardez votre espace de travail propre et bien éclairé.
Les établis encombrés et les zones mal éclairées
augmentent les risques d’accidents, de chocs électriques,
d’incendies et de blessures aux personnes.
N’utilisez pas des compresseurs dans des
atmosphères explosives, comme en présence de
liquides, de gaz ou de poussières inammables.
Maintenez la zone de travail bien ventilée. Installez
toujours le compresseur à au moins 20 pi (6,1 m) de
la zone de travail en cas de pulvérisation de matières
inammables. NE FUMEZ PAS pendant que vous
pulvérisez des matières inammables. Le compresseur
peut produire des étincelles qui risquent d’enammer la
poussière ou les fumées. N’utilisez jamais le compresseur
à des endroits où il y a de la laque, de la peinture, de la
benzine, du diluant, de l’essence, des gaz, des agents
adhésifs ou d’autres matériaux qui sont combustibles
ou explosifs. Un tuyau exible plus long sera peut-être
nécessaire.
Utilisez toujours le compresseur dans un endroit
bien ventilé. Suivez toutes les consignes de
sécurité et utilisez un appareil de protection
respiratoire conformément auxconsignes de sécurité
accompagnant le matériau à vaporiser. Certains
matériaux vaporisés, comme la peinture, les solvants pour
peinture, les décapants pour peinture, les insecticides, les
désherbants, etc. contiennent des poisons et des vapeurs
toxiques.
Ne laissez pas d’autres personnes, des enfants et
autres visiteurs s’approcher d’un compresseur en
marche. Ne permettez pas à des enfants d’utiliser le
compresseur. Des distractions risqueraient de causer la
perte de contrôle des compresseurs, ce qui pourrait causer
des blessures aux personnes se trouvant à proximité.
Ne chahutez jamais avec le compresseur. Respectez le
compresseur comme instrument de travail.
Utilisez toujours le compresseur dans une position
stable et sûre. Ne l’utilisez jamais sur une table ou
sur un toit. Utilisez un tuyau exible à air additionnel
pour permettre aux compresseurs d’atteindre des endroits
élevés.
séCurIté Personnelle
Il ne faut pas retirer ou altérer les commandes de
l’outil, ou les désactiver ou les rendre inutilisables
de quelque façon que ce soit. Ceci causerait un
fonctionnement irrégulier de l’outil et risquerait de causer
des blessures.
Habillez-vous de façon appropriée. Ne portez pas de
vêtements lâches ou de bijoux. Connez les cheveux
longs. Gardez vos cheveux, vêtements et gants à
distance des pièces en mouvement. Les vêtements
lâches, les bijoux et les cheveux longs risqueraient d’être
happés par des pièces en mouvement et augmenter le
risque de blessure.
Portez toujours des équipements de protection des
yeux et des oreilles lorsque vous utilisez cet outil.
Utilisez des équipements de protection individuelle
additionnels suivant les besoins lorsque vous utilisez
cet outil. Les opérateurs et les autres personnes se
trouvant dans la zone de travail doivent porter des lunettes
de sécurité. Une exposition prolongée à des bruits de
grande intensité risquerait de causer une perte auditive. Il
faut utiliser un masque antipoussières, des chaussures de
sécurité à semelle antidérapante, un casque et d’autres
équipements de protection individuelle en fonction des
conditions de travail.
N’utilisez pas le compresseur si vous ne savez pas
parfaitement comment vous en servir. Les utilisateurs
qui ne connaissent pas très bien toutes ses commandes
risquent de se servir du compresseur d’une manière
pouvant être dangereuse et se blesser ou de blesser
d’autres personnes.
Maintenez les commandes et les poignées sèches et
propres, sans résidus d’huile ou de graisse. Des mains
glissantes ne peuvent pas contrôler l’outil de façon sûre.
Restez alerte. Surveillez toujours ce que vous êtes en
train de faire et faites preuve de bon sens quand vous
utilisez un compresseur. N’utilisez pas le compresseur
lorsque vous êtes fatigué ou sous l’inuence de
drogues, d’alcool ou de médicaments. Un moment
d’inattention pendant que vous utilisez le compresseur
pourrait causer des blessures corporelles graves.
Ne dirigez pas un jet d’air vers des gens ou des
animaux. De l’air sous pression peut projeter de la
poussière et des débris à grande vitesse. De l’air comprimé
d’un compresseur peut contenir de l’eau, de l’huile,
des particules de métal ou d’autres contaminants qui
risqueraient de causer de graves blessures.
N’inspirez pas et ne respirez pas d’air comprimé.
N’inhalez jamais d’air directement du compresseur ou
d’un appareil respiratoire connecté au compresseur.
Un jet d’air comprimé peut contenir du monoxyde de
carbone, des vapeurs toxiques ou des particules solides
d’un réservoir d’air qui, en cas d’inhalation, pourraient
causer des lésions graves ou même la mort.
Faites très attention lorsque vous touchez des
surfaces du compresseur en métal. De nombreux
composants tels que la tête du compresseur, son moteur
et ses tuyaux resteront très chauds même après que le
compresseur d’air aura été mis hors tension. Laissez le
compresseur refroidir avant de le déplacer ou d’effec
tuer
une opération de maintenance.
ConsIGnes GénérAles de séCurIté
AVERTISSEMENT
Tous les utilisateurs et employeurs/propriétaires doivent lire et comprendre toutes les
instructions de ce mode d’emploi avant d’utiliser cet compresseur ou de procéder à
son entretien. Le non-respect des instructions indiquées plus bas risque de causer un choc électrique, une
blessure personnelle grave ou même la mort.
ConserVer Ces InstruCtIons

18
Ne montez pas sur le compresseur. Soyez toujours
bien stable et équilibré sur vos pieds. La stabilité et un
bon équilibre vous permettent de mieux contrôler l’outil
dans des situations inattendues.
Assurez-vous qu’il n’y a pas d’obstructions ou de
coudes dans le tuyau d’air. N’attachez pas un tuyau
d’air ou un outil à votre corps. Des tuyaux enchevêtrés
ou emmêlés risquent de faire perdre l’équilibre ou de
faire tomber l’opérateur en plus de causer un mouvement
imprévu de l’outil. Attachez le tuyau à la structure pour
réduire le risque de perte d’équilibre en cas de mouvement
du tuyau.
N’utilisez pas le tuyau de façon abusive. Protégez
tous les tuyaux contre les faux plis, les restrictions,
les solvants ou les objets tranchants. Maintenez le
tuyau d’air à distance de la chaleur, de l’huile, des
bords tranchants ou des pièces mobiles. Remplacez
immédiatement un tuyau endommagé. Un tuyau
endommagé risquerait d’éclater ou d’être projeté avec
violence à travers la zone de travail.
Utilisez seulement des tuyaux conçus pour une
pression nominale minimum de 200 psi. L’utilisation de
tuyaux conçus pour une pression nominale élevée réduit
le risque de blessure pouvant résulter de l’éclatement d’un
tuyau.
Saisissez fermement le tuyau dans la main en vue de
l’installation. Si le tuyau n’est pas tenu fermement ou
installé correctement, il risquerait de se libérer de votre
prise et de fouetter et blesser des personnes se trouvant
dans la zone de travail.
Prenez toutes les précautions nécessaires lorsque
vous soulevez et transportez le compresseur. Certains
compresseurs sont trop lourds pour être soulevés par une
seule personne. Demandez de l’assistance avant de tenter
de soulever un compresseur pour réduire le risque de
blessure.
Lorsque vous déplacez ou chargez un compresseur
sur roues, assurez-vous que ce compresseur est
toujours sur une surface plate. Si le compresseur
est placé sur une surface en pente, il risquerait de se
déplacer de façon imprévisible et de causer des blessures
corporelles.
Ce produit contient des produits chimiques,
notamment du plomb, qui, selon les informations
à la disposition de l’État de Californie, causent des
malformations congénitales et d’autres problèmes
affectant la reproduction. Lavez-vous les mains après
avoir utilisé le compresseur.
utIlIsAtIon et entretIen de l’outIl
Utilisez cet compresseur et ses accessoires
conformément aux instructions. Les compresseurs
et leurs accessoires doivent être utilisés dans le but pour
lequel ils sont conçus. L’emploi de les compresseurs pour
des opérations différentes de celles qui sont décrites dans
ce mode d’emploi peut créer une situation dangereuse.
Utilisez seulement des accessoires qui sont
recommandés par BOSCH pour votre modèle
particulier. Des accessoires qui peuvent être
recommandés pour un modèle d’outil particulier ne sont
peut-être pas appropriés pour d’autres modèles d’outils et
pourraient causer des blessures corporelles.
Avant chaque utilisation, inspectez tous les raccords
et tuyaux, ainsi que les boyaux et les connexions,
du compresseur. N’utilisez pas cet compresseur si
une partie quelconque de le compresseur est lâche,
manquante, endommagée, défectueuse, déconnectée
ou altérée. N’utilisez jamais un compresseur qui
semble être endommagé ou qui fonctionne de façon
anormale. Si le compresseur ne semble pas fonctionner
normalement et/ou s’il fait des bruits inhabituels, cessez
immédiatement de l’utiliser et contactez votre centre de
service après-vente BOSCH local. Il existe un risque
d’éclatement si le compresseur est endommagé.
Avant chaque utilisation, inspectez le compresseur
pour vous assurer qu’il n’y a pas de signes de fuites
ou d’autres dommages. Si vous trouvez des fuites
dans la pompe du compresseur, les réservoirs
d’air ou les tuyaux, remplacez immédiatement le
compresseur. Ne tentez jamais de réparer des fuites, de
souder ou d’apporter des modications au réservoir d’air
ou d’autres sections contenant des liquides étant donné
que ceci créerait un risque d’éclatement.
Ne tentez pas d’utiliser ce compresseur d’air sans
avoir vérié au préalable le niveau d’huile dans le
carter du moteur. Ce compresseur est expédié avec
de l’huile dans le carter du moteur. Le compresseur
pourrait être sérieusement endommagé par un
fonctionnement même momentané sans une lubrication
adéquate.
N’utilisez jamais le compresseur sans la valve
de sécurité en place. Vériez quotidiennement le
fonctionnement de la valve de sécurité. Ne vous
servez pas de la valve de sécurité pour compléter la
vidange du réservoir. La valve de sécurité est conçue pour
diminuer la pression du réservoir an de réduire le risque
d’éclatement.
N’utilisez jamais le compresseur si tous les dispositifs
de protection et autres mécanismes de sécurité
ne sont pas à leur place ou s’ils n’exercent pas la
fonction pour laquelle ils ont été conçus. Si une
opération de maintenance ou d’entretien nécessite le
retrait d’un dispositif de protection ou d’un mécanisme
de sécurité, n’oubliez pas de remettre ce dispositif de
protection ou ce mécanisme de sécurité en place avant
de recommencer à utiliser le compresseur. Remplacez
immédiatement tout dispositif de protection ou mécanisme
de sécurité endommagé.
Ne touchez jamais une pièce en mouvement. Ne
placez aucune partie de votre corps à proximité de pièces
en mouvement du compresseur. Ne vous penchez pas
au-dessus des dispositifs de protection an de réduire le
risque de blessure.
N’utilisez pas le compresseur sans le ltre à air. Les
ltres empêchent les grandes particules d’entrer dans le
ux d’air et d’endommager les composants internes du
compresseur.
Ne laissez pas de matières particulaires telles que
de la sciure tomber dans le carter du moteur lorsque
ce dernier est ouvert pour réaliser une inspection. La
présence de matières particulaires dans l’huile risquerait

19
de réduire la durée de vie du compresseur.
N’utilisez pas d’huile détergente dans le carter du
moteur. Les huiles détergentes laisseront des dépôts
sur les composants internes du compresseur, ce qui
réduirait la durée de vie du compresseur et affecterait sa
performance.
N’utilisez pas le compresseur dans le cadre d’un
fonctionnement sans surveillance. Restez toujours
à proximité lorsque le compresseur est en marche et
éteignez le compresseur quand il n’est pas utilisé an de
réduire le risque d’incendie.
Ne placez jamais d’objets sur le compresseur ou contre
celui-ci. Installez le compresseur à au moins 12 po
(30 cm) de toutes les obstructions. La restriction de
quelconques orices de ventilation du compresseur
pourrait causer une surchauffe et entraîner un incendie.
N’utilisez pas le compresseur avec une source
d’alimentation électrique différente de ce qui est
indiqué dans les consignes d’utilisation et de sécurité
de le compresseur. L’utilisation de sources d’alimentation
électrique différentes pourrait causer un mauvais
fonctionnement de le compresseur et de la source
d’alimentation électrique, ce qui risquerait de vous blesser
grièvement ou de blesser grièvement d’autres personnes
se trouvant près de vous.
Suivez toutes les recommandations en ce qui
concerne les tailles des tuyaux, des raccords et des
autres accessoires à air du compresseur. Des raccords
ou autres composants de tailles incorrectes pourraient
entraîner des risques de blessures ou de dommages aux
biens.
Ne déplacez jamais le compresseur en tirant sur
un tuyau exible. Le compresseur, les raccords pour
la circulation de l’air et le tuyau à air pourraient être
endommagés et éclater.
Inspectez les conduites d’alimentation en air
pour vous assurer qu’il n’y a pas d’obstacles à la
circulation de l’air avant de procéder à un réglage
de l’outil. Le volume d’air est aussi important que la
pression de l’air. Un débit d’air réduit empêchera l’outil de
fonctionner conformément à ce qui est prévu.
Ne dépassez jamais la pression nominale maximum
permise qui gure sur l’outils et sur ses accessoires.
N’utilisez pas le compresseur pour goner des
objets à basse pression d’air tels que des jouets. Le
dépassement de la pression maximum recommandée des
outils et accessoires risquerait de causer leur éclatement.
La pression correcte est la pression la plus faible qui suft
à faire le travail voulu.
Drainez quotidiennement le condensat des réservoirs
d’air en utilisant la valve de purge. Le drainage de l’eau
du compresseur d’air réduit le risque de corrosion du
réservoir d’air. Les réservoirs d’air corrodés ont un risque
d’éclatement accru.
Arrêtez le compresseur, drainez les réservoirs d’air
et laissez refroidir l’outil avant de procéder à des
réglages, de déplacer le compresseur, de quitter
la zone de travail, d’effectuer une opération de
maintenance ou de ranger le compresseur. De telles
mesures de sécurité à titre de précaution réduisent le
risque de blessure.
Ne modiez pas ce compresseur et ne vous en servez
pas à une pression ou à une vitesse supérieure à la
pression ou la vitesse nominale. Toute altération ou
modication est une utilisation abusive et risquerait de
créer une condition dangereuse telle qu’un incendie ou un
éclatement.
Lorsque vous transportez le compresseur, maintenez-
le de niveau et placez-le sur un tapis protecteur. Ne
mettez pas le compresseur sur son côté. De telles
précautions réduisent le risque d’incendie ou de danger
d’inhalation de vapeurs d’huile par le personnel
.
serVICe
Toute opération de maintenance réalisée par
du personnel non autorisé risque de causer
un repositionnement erroné de composants
internes et de créer ainsi des dangers graves.
Nous recommandons que toutes les opérations de
maintenance et de réparation soient effectuées dans
un centre de service usine BOSCH ou dans une station
service agréée BOSCH.
Préparez un programme de maintenance périodique
pour votre outil. Lorsque vous nettoyez un
compresseur, faites attention de ne pas démonter
une partie quelconque de l’outil étant donné que
des composants internes risqueraient d’être mal
remis en place ou que des compo sants nécessaires
à la sécurité risqueraient d’être remontés incorrecte-
ment. Certains produits de nettoyage, tels que
l’essence, le tétrachlorure de carbone, l’ammoniac, etc.
risquent d’endommager les composants en plastique et
les joints toriques.
Utilisez seulement des pièces de rechange
recommandées par BOSCH lors de toute opération
de réparation. Suivez les instructions de la rubrique
Maintenance de ce mode d’emploi. L’utilisation de
pièces non autorisées ou le non-respect des instructions
de maintenance pourrait causer un risque de blessure.
Remplacez les étiquettes d’avertissement
manquantes ou endommagées. Reportez-vous aux
schémas pour déterminer le positionnement correct
avec le numéro de pièce.
Effectuez une maintenance soigneuse du
compresseur. Maintenez le compresseur propre
et lubrié. Des outils entretenus de façon soignée
sont moins exposés à des risques de rupture qui
pourraient causer des blessures. Toute altération ou
modication est une utilisation abusive et risquerait de
créer une condition dangereuse.
Lorsque vous ne vous en servez pas, rangez le
compresseur hors de la portée des enfants et des
autres personnes ne maîtrisant pas le fonction-
nement de le compresseur. Quand il n’est pas utilisé,
l’outil doit être déconnecté et rangé dans un endroit sec.
Gardez hors de la portée des enfants. Verrouillez le lieu
de rangement. Les compresseurs sont dangereux s’ils
tombent entre les mains d’utilisateurs ne maîtrisant pas
leur fonctionnement.

20
ConsIGnes de séCurIté Pour les ComPresseurs éleCtrIques
Les ches des cordons d’alimentation électrique
doivent être compatibles avec les prises de
courant dans lesquelles elles sont branchées. Ne
modiez jamais une che de quelque façon que
ce soit. N’utilisez pas d’adaptateurs de ches
avec des outils électriques mis à la masse (à la
terre). L’insertion de ches non modiées dans des
prises de courant assorties réduira le risque de choc
électrique.
Évitez tout contact corporel avec des surfaces
mises à la terre ou à la masse telles que celles
de tuyaux, de radiateurs, de cuisinières ou de
réfrigérateurs. Il existe un risque accru de choc
électrique si votre corps est en contact avec la terre
ou mis à la masse.
Ne traitez pas le cordon d’alimentation électrique
de façon abusive. N’utilisez jamais le cordon
pour transporter, tirer ou débrancher l’outil
électrique. Maintenez le cordon à distance de
sources de chaleur, d’huile, de bords tranchants ou
de pièces mobiles. Remplacez immédiatement tout
cordon endommagé. Les cordons enchevêtrés ou
emmêlés augmentent le risque de choc électrique.
N’exposez pas ce compresseur à la pluie. Ne
l’utilisez pas à des endroits humides ou mouillés.
L’humidité augmente le risque de choc électrique
avec cet équipement.
Ne touchez pas la che avec les mains mouillées.
L’humidité augmente le risque de choc électrique
avec cet équipement.
Gardez toutes les connexions électriques
sèches et à distance du sol. Ne laissez pas de
connexions électriques reposer à des endroits
où il y a de l’eau ou dans des positions telles que
de l’eau pourrait entrer en contact avec le cordon
d’alimentation ou une autre connexion électrique.
L’humidité augmente le risque de choc électrique
avec cet équipement.
Lorsque vous utilisez un outil électrique à
l’extérieur, employez une rallonge appropriée
pour un emploi à l’extérieur et avec une intensité
électrique de niveau correct. L’utilisation d’un
cordon conçu pour emploi à l’extérieur réduit le
risque de choc électrique.
Débranchez toujours le compresseur de la prise
de courant, ventilez les réservoirs d’air et laissez
le compresseur refroidir avant d’effectuer une
opération de maintenance. Les compresseurs
pourvus de contrôles de pression automatisés
peuvent se remettre en marche à tout moment.
Arrêtez toujours le moteur quand il n’est pas
utilisé et avant de déplacer le compresseur.
L’arrêt du moteur empêche une mise en marche
accidentelle du compresseur.
Arrêtez et mettez toujours le moteur hors tension
avant de procéder à de quelconques réglages,
de changer des accessoires, de déplacer le
compresseur, quand le compresseur n’est
pas utilisé et avant de ranger le compresseur.
L’arrêt du moteur empêche une mise en marche
accidentelle du compresseur.
Les travaux à la machine tel que ponçage,
sciage, meulage, perçage et autres travaux
du bâtiment peuvent créer des poussières
contenant des produits chimiques qui sont des
causes reconnues de cancer, de malformation
congénitale ou d’autres problèmes reproductifs.
Ces produits chimiques sont, par exemple:
• Le plomb provenant des peintures à base de
plomb,
• Les cristaux de silices provenant des briques et du
ciment et d’autres produits de maçonnerie, et
• L’arsenic et le chrome provenant des bois traités
chimiquement
Le niveau de risque dû à cette exposition varie avec
la fréquence de ces types de travaux. Pour réduire
l’exposition à ces produits chimiques, il faut travailler
dans un lieu bien ventilé et porter un équipement
de sécurité approprié tel que certains masques
à poussière conçus spécialement pour ltrer les
particules microscopiques.
ConserVeZ Ces InstruCtIons
This manual suits for next models
2
Table of contents
Languages:
Other Bosch Air Compressor manuals
Popular Air Compressor manuals by other brands

Elmo Rietschle
Elmo Rietschle V Series operating instructions

Anest Iwata
Anest Iwata SL-140EB-US instruction manual

Gude
Gude 580/10/100 EU 400V Translation of original operating instructions

Schneider Airsystems
Schneider Airsystems H812100 User manual and installation instructions

Master
Master DHA 10 User and Maintenance Book

Michelin