English | 9
Bosch Power Tools 1 619 929 J69 | (5.8.11)
fDonotoperate the measuringtool in explosiveenviron-
ments, such as in the presence of flammable liquids,
gases or dusts. Sparks can be created in the measuring
tool which may ignite the dust or fumes.
Product Description and
Specifications
Intended Use
The measuring tool is intended for determining and checking
horizontal and vertical lines.
The measuring tool is suitable exclusively for operation in
enclosed working sites.
Product Features
The numbering of the product features shown refers to the
illustration of the measuring tool on the graphic page.
1Exit opening for laser beam
2Automatic levelling indicator
3On/Off switch
4Latch of battery lid
5Battery lid
6Contact surface
7Laser warning label
8Tripod mount 1/4"
9Protective pouch
10 Laser viewing glasses*
11 Tripod*
* The accessories illustrated or described are not included as
standard delivery.
Technical Data
Assembly
Inserting/Replacing the Battery
Alkali-manganese batteries are recommended for the meas-
uring tool.
Toopen thebattery lid5, presson the latch 4and fold the bat-
tery lid up. Insert the batteries. When inserting, pay attention
to the correct polarity according to the representation on the
inside of the battery compartment.
Always replace all batteries at the same time. Only use batter-
ies from one brand and with the identical capacity.
fRemove the batteries from the measuring tool when
not using it for extended periods. When storing for ex-
tended periods, the batteries can corrode and discharge
themselves.
Operation
Initial Operation
fProtectthe measuring tool against moisture and direct
sun light.
fDo not subject the measuring tool to extreme tempera-
tures or variations in temperature. As an example, do not
leave it in vehicles for longer periods. In case of large varia-
tions in temperature, allow the measuring tool to adjust to
the ambient temperature before putting it into operation.
fAvoid heavy impact to or falling down of the measuring
tool. Damage to the measuring tool can impair its accuracy.
After heavy impact or shock, compare the laser line with a
known horizontal or vertical reference line.
fSwitch the measuring tool off during transport. When
switching off, the levelling unit, which can be damaged in
case of intense movement, is locked.
Switching On and Off
To switch on the measuring tool, push the On/Off switch 3to
the “On” position. Immediately after switching on, the meas-
uring tool sends two laser beams out of the exit opening 1.
fDo not point the laser beam at persons or animals and
do not look into the laser beam yourself, not even from
a large distance.
To switch off the measuring tool, slide the On/Off switch 3to
the “Off” position. When switching off, the levelling unit is
locked.
fDonotleavethe switched onmeasuring tool unattended
and switch the measuring tool off after use. Other per-
sons could be blinded by the laser beam.
Working with Automatic Levelling (see figures A–B)
Position the measuring tool on a level and firm support, hold
itby the contactsurfaces 6against avertical surfaceor attach
it to a tripod 11.
After switching on, the levelling function automatically com-
pensates irregularities within the self-levelling range of ±4°.
The levelling is finished as soon as the laser beams do not
move any more. The indicator 2lights up green.
Cross-line Laser PCL 10
Article number 3 603 K08 1..
Working range to approx. 10 m
Levelling Accuracy ±0.5 mm/m
Self-levelling range, typically ±4°
Levelling duration, typically 4s
Operating temperature +5 °C...+40 °C
Storage temperature –20 °C...+70 °C
Relative air humidity, max. 90 %
Laser class 2
Laser type 635 nm, <1 mW
C6>10
Tripod mount 1/4"
Batteries 2x1.5VLR06(AA)
Operating life time, approx. 15 h
Weight according to
EPTA-Procedure 01/2003 0.4 kg
Dimensions (length x width x height) 108x66x92mm
Please observe the article number on the type plate of your measuring
tool. The trade names of the individual measuring tools may vary.
OBJ_BUCH-693-003.book Page 9 Friday, August 5, 2011 9:01 AM