II Contents Rexroth IndraDrive Mi
DOK-INDRV*-KCU+KSM****-PR01-EN-P
4 General Specification of the Components 4-1
4.1 Certifications................................................................................................................................. 4-1
4.2 Transport and Storage.................................................................................................................. 4-2
Transporting the Devices......................................................................................................... 4-2
Storing the Devices ................................................................................................................. 4-2
4.3 Installation Conditions................................................................................................................... 4-2
Ambient and Operating Conditions.......................................................................................... 4-2
Type of Construction and Mounting Positions......................................................................... 4-4
Compatibility with Foreign Matters .......................................................................................... 4-4
Prime Coat and Housing Varnish............................................................................................ 4-4
4.4 Capacity Utilization....................................................................................................................... 4-5
5 Technical Data of the Components 5-1
5.1 Explanation of Terms and Definitions........................................................................................... 5-1
5.2 Distributed Servo Drive KSM........................................................................................................ 5-5
KSM Data Sheet...................................................................................................................... 5-5
KSM Characteristics................................................................................................................ 5-7
Dimensions and Technical Design........................................................................................ 5-10
Bearings and Shaft Load....................................................................................................... 5-12
5.3 Electronic Control System KCU.................................................................................................. 5-14
Brief Description and Applications......................................................................................... 5-14
Technical Data....................................................................................................................... 5-14
5.4 Hybrid Cables RKH..................................................................................................................... 5-17
Technical Data....................................................................................................................... 5-17
Selecting Ready-Made Cables.............................................................................................. 5-17
Interconnection Diagrams for Ready-Made Hybrid Cables................................................... 5-19
6 Connection Points 6-1
6.1 Connection Points of System ....................................................................................................... 6-1
Equipment Grounding Conductor............................................................................................ 6-1
Ground Connection ................................................................................................................. 6-2
6.2 Connection Points of KCU............................................................................................................ 6-3
Positions of the Connection Points.......................................................................................... 6-3
X1, Module Bus ....................................................................................................................... 6-4
X20 TX, X21 RX (SERCOS interface)..................................................................................... 6-5
X50, E-Stop Input .................................................................................................................... 6-6
X51, Master Communication SERCOS................................................................................... 6-6
X52, Status Messages............................................................................................................. 6-7
X53, Control Voltage Output.................................................................................................... 6-7
X54, DC Bus, Equipment Grounding Conductor Output KSM................................................ 6-8
DC Bus Connection L+, L-....................................................................................................... 6-9
Control Voltage Supply +24V, 0V.......................................................................................... 6-11
Connection Accessory........................................................................................................... 6-12
6.3 Connection Points of KSM.......................................................................................................... 6-13
Positions of the Connection Points........................................................................................ 6-13
X2 Serial Interface, Service Input "Release Brake"............................................................... 6-14