Thermostat Digital TH26
Voltage 230V
Consumption:<1W
Temperature control range:5- 0 ℃
Temperature limitation range:16-60 ℃
Temperature switch deviation:Default 1 ℃
(0.5-10 ℃ adjustable )
Ambient temperature:0-50 ℃
Protection class:IP20
Load capacity:16A
Connecting Cable:RVV0.5
Housing material:Anti-flame PC
:
Parameter
1 Switch on and off
Press button .
2 Temperature setting
Press to set temperature.
3 Clock setting
Press and together for 5s to enter clock setting
mode. Press to switch parameter and press
to revise.
4 Manual / Time period mode selection
Press to switch between Manual mode and Time
period mode
5 lock
Press together for 5s to lock or unlock the
buttons.
.
.
button
.
button
button
button
.
button
.
.Button
button
The display interface and user settings
Temperature
calibration Temperature adjustment
Adjust by orbutton
Function
Symbol
No .
1
6
4
5
7
8
Default OFF
The setting range is
after activation
5~10 ℃
2
3
5(rest on Sat and Sun. Default)
6 rest on Sun
no rest day
OFF
( )
( )
(shut off Weekly program)
7
thermostat is in off mode
ON:
OFF: thermostat stays in the same
mode before power off (Default)
Press button until --- is displayed
Advanced Settings
These settings are for professional technical personnel.Usually
finished at the initial installation.Press together
when the thermostat is switched off,and then switch on the
thermostat to enter Advanced Settings. Press to switch
menu. Press to exit current operating mode.
button
button
button
LCD Digital Thermostat can work in Manual mode
or Energy-saving mode. It can be used in electric
heating control system.
It means the internal sensor malfunction when ER0 appears.
Sensor malfunction
Manual Mode
Thermostat works according to the manual set temperature.
Not controlled by program.
Period Mode
Weekly recycle. You can set 4 time periods and corresponding
temperature every day for auto operation.
Time period, temperature, rest days can be programmed upon
the customers' request.
Temporary Mode
Thermostat is temporarily switched to manual mode from
current time period mode.
Thermostat will automatically restore to time period mode
when the next time period comes.
Operating mode description
Hold key for at least 5s to enter period programming
Revise
Revise
Option Symbol Default
Time
Default
Temp.
Time
Period
Working
days
Rest
days
Revise time
1
2
3
4
1
2
20℃
15℃
22℃
15℃
15℃
06:00
08:00
17:00
22:00
08:00
23:00
Period programming
22℃
Model
TH26
DescriptionCurrent
16A Control and limit
by double sensors Increase button
Decrease button
Menu button ON/OFF button
Time period mode
Manual mode
Button lock
Anti-freeze function
Heating
Mon~Sun
Time period
Revise
temperature
Restore to
factory settings
Thermostat status
when power on
Set the upper
temperature limit
Switch deviation 0.5~10 ℃.Default 1.0 ℃
Set range .
16~ 0 ℃
Default 35 .0℃
Anti-freeze function
Rest day selection
and shut off Weekly
program
Installation Instructions
1-8 2-8 3-8 4-8
1 2 3 4 5 6 7
menred
Sensor mode
IN: built-in sensor
OUT: floor sensor
ALL: controlled by built-in sensor
and limited by floor sensor (Default)
Floor limit
temperature setting 16~60 ℃.Default 45 ℃