OPERATION MANUAL
Technical changes reserved
0141 0315-20 02.12.2015
Infrared thermometer
Flashbeam 8869
DescriptionDescription
Product description
The infrared thermometer FlashBeam 8869 is a handy and precise de-
vice for contactless temperature measurements. It‘s features are:
• Laser sight
• Switchable between °C / °F
• Automatic Hold function
• Automatic switch-off
• Illuminated display
• Fixed emissivity
• Battery change indicator
Safety
• Use extreme caution when the laser beam is turned on.
• Do not let the beam enter your eye, another person’s eye or the eye
of an animal.
• Be careful not to let the beam on a reective surface strike your eye.
• Do not allow the laser light beam impinge on any gas which can
explode.
Operating elements
Operation
Operating element Description
Power ON/OFF The meter automatically powers when the
ON/HOLD key is pressed. Press the MEASU-
RE key to take a reading. Read the measured
temperature on the LCD. The meter powers
OFF automatically approximately 5 seconds
after the ON/HOLD key is released.
Selecting
Temperature units
(°C/°F)
Select temperature units (degrees C or F)
by rst pressing the ON/HOLD key and then
pressing the °C/°F key. The units will blink
on the LCD. Press the °C/°F key until the
desired units are shown on the LCD.
Data Hold This meter automatically holds the last tem-
perature reading on the LCD for ve seconds
after the ON/HOLD key is released. No extra
key presses are necessary to freeze the
displayed reading.
Backlite LCD Select backlite by rst pressing the ON/HOLD
key and then pressing the BACKLITE key.
Repeat the procedure to turn the backlight
OFF.
Laser Pointer To turn the laser pointer ON, press the
LASER key while pressing the ON/HOLD key.
Repeat the procedure to turn the laser OFF.
B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen
Fon +49 771 83160 | Fax +49 771 8316-50 | [email protected] | bb-sensors.com
1 / 2
OPERATION MANUAL
Technical changes reserved
0141 0315-20 02.12.2015
Infrared thermometer
Flashbeam 8869
Measurement conditions
Holding the meter by its handle, point the IR Sensor toward the object
whose temperature is to be measured.
The meter automatically compensates for temperature deviations
from ambient temperature. Keep in mind that it will take up to 30
minutes to adjust to wide ambient temperature changes.
When low temperatures are to be measured followed by high tempe-
rature measurements, some time (several minutes) is required after
the low (and before the high) temperature measurements are made.
This is a result of the cooling process which must take place for the
IR sensor.
Battery replacement
A ashing display is the indication that the battery voltage has
fallen into the critical region (6.5 to 7.5 V). Reliable readings can be
obtained for several hours after the rst appearance of the low battery
indication. Open the Battery Compartment and remove the batte-
ry,then install a new battery and replace the cover.
Optical resolution
Technical data
Features Values
Measuring range -20...+420 °C
Operating conditions 0...50 °C, max. 80% RH
Accuracy ±2 °C (-20...+100 °C),
±3% or ±3 °C (+1000...+420 °C)
Resolution 1 °C
Response time 1 s
Emissivity 0,95 xed
Optical resolution 8:1
Battery 9 V
Dimensions 170x44x40 mm, 200 g
CE-conformance 2004/108/EG
Electromagnetic
conductivity
EN 61326-1:2013
Articlenumber 0560 8869
B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen
Fon +49 771 83160 | Fax +49 771 8316-50 | [email protected] | bb-sensors.com
2 / 2

Other B+B Sensors Thermometer manuals

B+B Sensors DM-Compact Series User manual

B+B Sensors

B+B Sensors DM-Compact Series User manual

B+B Sensors HM 1150 User manual

B+B Sensors

B+B Sensors HM 1150 User manual

B+B Sensors 8856 User manual

B+B Sensors

B+B Sensors 8856 User manual

B+B Sensors FlashBeam 8869 User manual

B+B Sensors

B+B Sensors FlashBeam 8869 User manual

B+B Sensors A307 User manual

B+B Sensors

B+B Sensors A307 User manual

B+B Sensors IR 8895 User manual

B+B Sensors

B+B Sensors IR 8895 User manual

Popular Thermometer manuals by other brands

Clas Ohlson talk th1091 user manual

Clas Ohlson

Clas Ohlson talk th1091 user manual

Fluke 5626/5628 user guide

Fluke

Fluke 5626/5628 user guide

Livan BT0512-03 user manual

Livan

Livan BT0512-03 user manual

Oregon Scientific RMR383HG user manual

Oregon Scientific

Oregon Scientific RMR383HG user manual

Yamato BF200 manual

Yamato

Yamato BF200 manual

ETI THERMAMITE operating instructions

ETI

ETI THERMAMITE operating instructions

Weber 32908 quick start guide

Weber

Weber 32908 quick start guide

Extech Instruments RH10 user guide

Extech Instruments

Extech Instruments RH10 user guide

Sechang Instruments TM-969 Operation manual

Sechang Instruments

Sechang Instruments TM-969 Operation manual

optris CTlaser LT Operator's manual

optris

optris CTlaser LT Operator's manual

Microlife MT 710 user manual

Microlife

Microlife MT 710 user manual

Omega Engineering HH806W instruction sheet

Omega Engineering

Omega Engineering HH806W instruction sheet

TESTO 925-2 instruction manual

TESTO

TESTO 925-2 instruction manual

Braun BNT 400B manual

Braun

Braun BNT 400B manual

Xylem Ebro TMX Series manual

Xylem

Xylem Ebro TMX Series manual

Optex THERMO-HUNTER BUILT-IN instruction manual

Optex

Optex THERMO-HUNTER BUILT-IN instruction manual

Omega Engineering HH-21A user guide

Omega Engineering

Omega Engineering HH-21A user guide

miniland baby THERMO ADVANCED manual

miniland baby

miniland baby THERMO ADVANCED manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.