WHAT’S INCLUDED
• Vive Precision Oral Thermometer
• Storage Case
• User Manual
WARNING
• Read instructions thoroughly before using the
digital thermometer.
• Choking Hazard: Thermometer cap and battery may be
fatal if swallowed. Do not allow children to use this device
without adult supervision.
• Do not use thermometer in the ear. Designed use is for
oral, rectal and armpit (axilla) readings only.
• Do not place thermometer battery near extreme heat as
it may explode.
• Use of a probe cover may result in a 0.1°C (0.2° F)
discrepancy from actual temperature.
• It is recommended that the performance should be
checked every two years.
• Remove the battery from the device when not in
operation over long periods of time.
• The performance of the digital thermometer may be
degraded if one or more of the following occur:
a) Operation outside the stated temperature and
humidity range
b) Storage outside the stated temperature and
humidity range
c) Mechanical shock
d) Patient temperature is below ambient temperature
• Do not bend or drop digital thermometer.
It is not shockproof.
• Do not boil probe to disinfect.
• Do not store in direct sunlight or in areas of extreme heat.
• Do attempt to disassemble or repair thermometer. See
BATTERY REPLACEMENT to replace the battery. Do not place in
domestic trash. Recycle or dispose of as hazardous waste.
Battery contains mercury.
• Avoid strong electromagnetic interference such as
microwave ovens and cell phones.
• After each use, disinfect thermometer, especially in case
the device is used by more than one person.
HOW TO CHANGE BETWEEN CELSIUS AND FAHRENHEIT
Temperature readings are available in both Celsius and
Fahrenheit (°C/°F is displayed in the upper right corner
of the LCD screen). With the device turned off, press and
hold the On/Off button for approximately three seconds to
change the current settings.
OPERATING INSTRUCTIONS
1. Wipe the probe with isopropyl alcohol to disinfect.
2. Press the On/Off button next to the LCD display to turn
the device on. A tone will sound as the display shows ’ ’
. The display will then show the current temperature scale,
followed by the last temperature reading or Lo if no
reading was taken. The thermometer is now in
testing mode.
3. Position thermometer in the desired location (mouth,
rectum, armpit)
E
M
,
Figure 1
Figure 2
b.) Rectal use: Lubricate silver probe tip with petroleum
jelly for easy insertion. Gently insert sensor approximately
1 cm (less than 1/2”) into the rectum. Normal temperature
range for a rectal reading is between 36.2°C and 37.7°C
(97.2°F and 99.9°F).
c.) Armpit use: Wipe armpit dry. Place probe in the armpit
and keep arm firmly pressed at side. From a medical
viewpoint, this method will always provide inaccurate
readings, and should not be used in precise readings
are required. Normal temperature range for an axilla
reading is between 35.2°C and 36.7°C (95.4°F and 98.1°F).
a.) Oral use: Place thermometer
probe under the tongue as
indicated by the check mark in
Figure 2. Close your mouth and
breathe evenly through the nose
to prevent the measurement from
being influenced by inhales/exhaled
air. Normal temperature range for
an oral reading is between 35.7°C
and 37.3°C (96.3°F and 99.1°F).
Probe
LCD
ON/OFF Button
4. When the peak temperature is reached, the degrees
sign will stop flashing and an audible alarm will sound.
Note: A normal temperature will sound as steady beeps
“Bi-Bi-Bi-Bi”; alarm sounds more rapidly when temperatures
of 37.8°C (100°F) are detected “Bi-Bi-Bi-----Bi-Bi-Bi---”.
5. To prolong battery life, press the On/Off to turn the
device off after testing. If no action is taken, the device will
automatically shut off after ten minutes of inactivity.
6. Wipe the probe with isopropyl alcohol to disinfect and
store in provided protective case.
BATTERY REPLACEMENT
1. Replace battery when the “ ” appears in the lower right
corner of the LCD display.
2. Using a thin board, such as a coin, turn the fillister
counter-clockwise until the battery cover is off.
(See figure below)
3. Use a non-metal instrument to remove the old battery
from the battery holder. Dispose of the old battery,
according to local law.
4. Place a new 3.0V DC button battery type CR2032 into the
thermometer with the positive side facing up.
Replace battery cover and turn clockwise to firmly lock the
cover into position.
CLEANING AND DISINFECTING
For general cleaning, wipe the thermometer down with
a damp cloth and mild detergent. Dry immediately with a
soft, dry cloth. Disinfect the thermometer probe by wiping or
dipping the tip in a solution of isopropyl alcohol.
PRODUCT DISPOSAL
Please ensure environmental protection. Batteries do
not belong in domestic waste but should be treated as
hazardous waste. Please dispose of them at a designated
collection point or recycling center according to local law.
LEGAL REQUIREMENTS AND GUIDELINES
This thermometer is manufactured according to the
system of EN12470-3:2000+A1:2009, ASTME1112-00. This
thermometer complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
this thermometer may not cause harmful interference,
and (2) this thermometer must accept any interference
received including interference that may cause undesired
operation. And the manufacturer is ISO 9001: 2008 and
ISO 13485:2003 + AC: 2007 certified.
SPECIFICATIONS
GUARANTEE REGISTRATION
You are protected by Vive Health’s industry leading
guarantees and customer service:
If you did not purchase through vivehealth.com, please
register at vivehealth.com/register to validate
your guarantee.
Product Code: DMD1026GRY
© Copyright and Distributed by Vive Health
8955 Fontana Del Sol Way, Naples, FL 34109
All Rights Reserved. Made in China.
Email: [email protected]
Type: Digital Thermometer (Not Predictive)
Range: 32.0°C ~ 42.9°C (90.0°F ~ 109.9°F) (°C/°F chosen
by manufacturer)
Accuracy: ±0.2°C under 35.5°C or over 42.0°C
(±0.4°F under 95.9°F or over 107.6°F)
at ambient temperature of 18°C to 28°C
(64.4°F to 82.4°F)
Display: Liquid crystal display, 3 1/2 digits
Memory: Last 10 memory
Battery: One 3.0V DC button battery type CR2032
Battery Life: Approx 200 hours
Dimension: 13.5cm x 3.4cm x 1.8cm (LxWxH)
Weight: Approx 21 grams including battery
Using Environment: Temperature: 5°C ~ 40°C (41°F ~ 104°F)
Relative humidity: 15% ~ 95%RH
Storage and
Transportation
Condition:
Temperature: -20°C ~ 55°C (-4°F ~ 131°F)
Relative humidity: 15% ~ 95%RH
Ingress Protection
Rating: IP27
Classication: Type BF
Figure 3 Figure 4 Figure 5 Figure 6 Figure 7
VIVE GUARANTEE

Other Vive Thermometer manuals

Vive DMD1024GRY User manual

Vive

Vive DMD1024GRY User manual

Vive DMD1010 User manual

Vive

Vive DMD1010 User manual

Popular Thermometer manuals by other brands

TQC TE1005 instruction manual

TQC

TQC TE1005 instruction manual

PCE Instruments PCE-779N manual

PCE Instruments

PCE Instruments PCE-779N manual

Timex TX1002 Specifications

Timex

Timex TX1002 Specifications

VOLTCRAFT PTM-120 operating manual

VOLTCRAFT

VOLTCRAFT PTM-120 operating manual

Terdens 2109 Manual User

Terdens

Terdens 2109 Manual User

TESTO 845 instruction manual

TESTO

TESTO 845 instruction manual

Inovalley WIRELESS POOL THERMOMETER user manual

Inovalley

Inovalley WIRELESS POOL THERMOMETER user manual

ETI DISHTEMP operating instructions

ETI

ETI DISHTEMP operating instructions

SW-Stahl 72360L instruction manual

SW-Stahl

SW-Stahl 72360L instruction manual

Digoo DG-IR805 Quick user guide

Digoo

Digoo DG-IR805 Quick user guide

Dr.Frei MI-200 user manual

Dr.Frei

Dr.Frei MI-200 user manual

DeltaTRAK JXB-178 user guide

DeltaTRAK

DeltaTRAK JXB-178 user guide

nilan VPL 28 user manual

nilan

nilan VPL 28 user manual

ACU-RITE 603 instruction manual

ACU-RITE

ACU-RITE 603 instruction manual

Maverick ET-73 REDI CHECK SMOKER instruction manual

Maverick

Maverick ET-73 REDI CHECK SMOKER instruction manual

Omega OS425-LS user guide

Omega

Omega OS425-LS user guide

Levenhuk Wezzer PLUS LP30 user manual

Levenhuk

Levenhuk Wezzer PLUS LP30 user manual

Exergen TemporalScanner TAT-5000S-RS232-CORO Operator's manual

Exergen

Exergen TemporalScanner TAT-5000S-RS232-CORO Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.