Bristan Wave Single Outlet Touchpad Mounting instructions

Installation Instructions
and User Guide
Wave Single Outlet Touchpad
Models Covered:
All Wave Showers
Please keep this booklet for future
reference.
Installer, when you have read these
instructions please ensure you leave
them with the user.

2Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Contents
Contents
• Important Safety Information 3
• General Information 4
• Specifications 5
• Water Requirements 6
• Water Connections 7
• Electrical Requirements 8
• Installation - Mixer Unit 9
• Installation - Wall Outlet/Interface Unit 10
• Operating the Shower - On 11
• Operating the Shower - O 12
• System Set Up/User Customisation 13
• Maintenance 14
• Guarantee/Spares 15
Welcome to your new Bristan Digital Electronic Mixer Shower, featuring a
contemporary design, wired electronic controller and digital mixing unit.
Bristan’s Digital Electronic Mixer Shower has been designed to be easy to
install and use. It has also been designed and tested in the UK to all of the
relevant British Standards.
These instructions are for your guidance to a safe and successful installation,
so please read them thoroughly and retain for future reference.
We recommend the installation is carried out by a suitably qualified person
and must conform with current I.E.E Wiring Regulations (BS7671) and
Building Regulations (Part P and Part G).

3
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Important Safety Information
• Please read these instructions
thoroughly and retain for future use.
• All products manufactured and
supplied by Bristan are safe provided
they are installed, used correctly
and receive regular maintenance in
accordance with these instructions.
• If you are in any doubt about your
ability to install this product safely
you must employ the services of
an experienced qualified plumber/
electrically qualified person.
• This Digital Electronic Mixer
Shower needs to be installed in
accordance with, and meet the
requirements of the Water Supply
(Water Fittings) Regulations 1999 and
Scottish Byelaws 2004.
Before starting any installation
please consider the following:
• Before drilling into walls, check
that there are no hidden electrical
wires, cables or water supply pipes.
This can be checked with the aid of an
electronic detector.
• Do not install this shower unit in a
room/environment without adequate
ventilation or an extractor fitted. This
is required to prevent condensation
forming within the unit.
• Do not operate the shower unit if
the shower head or spray hose has
been damaged or is blocked.
• Do not block the flow of water
from the shower head, by placing it
(smothering it) on your hand or any
other part of your body or foreign
object.
• Do not operate the shower if
the water stops flowing during
use or if the water is leaking from
the Mixing Valve itself. Turn o at
the mains electrical supply and refer
to the Troubleshooting section or
contact Bristan Customer Services on
0330 026 6273.
Warning: Do not operate this
product if you suspect it is
frozen. Do not site the Mixing
Valve where it might be
subjected to freezing conditions.
Warning: Before installing the
new Digital Electronic Mixer
Shower it is essential that you
thoroughly flush through the
pipe work in order to remove any
remaining swarf, solder, etc.
Failure to carry out this
procedure could cause problems
or damage to the workings of
the Mixing Valve.

4Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
• Remove all packaging and check the contents for damage before starting any
installation.
• Fitting isolation valves to the inlet feeds is required as close as is practical to
the inlet connections for ease of maintenance.
• Always switch o the power at the consumer unit and isolate the electrical
supply before making any electrical connections or if you have to remove the
cover of the Control Panel.
• This product must not be modified in any way as this will invalidate the
guarantee.
General Information

5
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
5°C
28°C
Pressure
BAR
6.0
8.0
10.0
0
4.0
2.0
1.0
5.0
4.0
3.02.0
48°C
65°C
Heavy
Commercial
Maximum Static Pressure:
1.0 Pa (10.0 bar)
Inlet Water Temperature
1/2” BSP
Male Threaded
Min: 0.1 MPa
( 1 bar)
Max: 0.6 MPa
(6.0 bar)
Working Pressures
Inlet Connection
Cold Water
Supply
Tools You’ll Need
1/2” BSP
Male
Threaded
Pack Contents
Cross-head Screwdriver
Pencil Drill
Pipe Cutter
PliersPipe & Wire Detector
Spirit Level
Pressure
BAR
0
Specifications
Hot Water
Supply
Light
Commercial
Recommended Usage
Healthcare
Domestic
Measurements
1.2mm Hex Key
Silicone Gun
Safety Glasses
Adjustable
Spanner
Outlet Connection
Specifications
34
12
8
6
99 38
99
19
163 58
x1
x1
x1
x1
x2

Hose
Retainer
Bath
Spillover
Leverl
Shower Tray
Spillover Level
Minimum
20mm
Between
Showerhead
& Spillover
Wall Outlet
Controller
6Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Water Requirements
This fitting needs to be installed in accordance with
the following Installation Requirements and Notes
(IRN) to ensure they meet the requirements of the
Water Supply (Water Fittings) Regulations 1999 and
the Scottish Byelaws 2014.
The fitting shall be installed so that its outlet
discharges above the spill-over level of any fixed
appliance as indicted on the illustration to the right.
For backflow protection in premises or installations
up to, and including Fluid Category 3 and 5.
The vertical distance of the outlet above the spill-
over level shall be not less than 20mm or twice
the diameter of the inlet pipe to the fitting, which
ever is the greater. If the fitting cannot be installed
as indicated it shall be installed with a backflow
prevention arrangement suitable for the Fluid
Category.
If the shower is to be installed in a hard water area, we recommend that an in-line scale inhibitor
is fitted which will prolong the life of the shower. Please refer to your supplier for advice.
Maximum ambient temperature: 40°C.
A minimum working inlet pressure of 0.1MPa (1bar) at a minimum flow rate of 10 litres
per minute is recommended for full performance.
The maximum static inlet pressure must not exceed 1.0MPa (10bar).
The shower must be connected to a mains water supply only with a minimum working inlet
pressure of 0.1 MPa (1bar) at a minimum flow rate of 10 litres per minute. The maximum static
inlet pressure must not exceed 1.0MPa (10bar).
If it is intended to operate the shower at pressures above the maximum stated, a suitable
pressure reducing valve (PRV) should be used.
Water regulations stipulate that the shower head be ‘constrained by a fixed or sliding
attachment (hose retainer) so that it can only discharge water at a point not less than 20mm
above the spill over level of the bath or shower tray or other fixed appliance’.
If a shower head can sit within a bath, basin or shower tray, you must fit a double check valve
in the supply pipe work to prevent back siphonage. If the shower head can sit within a WC then
the air gap should be a type AUK3 not less than 20mm or twice the diameter of the inlet pipe to
the fitting, whichever is greater.
As this shower unit is already supplied with a single check valve pre-fitted in each water supply
inlet, a further single check valve would be required in such a situation, fitted in each water
supply as close as possible to the existing check valves.
Warning: The shower must not be installed in an area subject to freezing conditions.
Do not use if you suspect the shower is frozen, this will damage the shower unit.

7
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Water Connections
Plumbing Connections
Warning: Do not solder within 300mm of the Mixing Valve or allow solder or
flux to fall onto the casing.
Important: An additional independent stop valve complying with the current
water regulations must be fitted in the mains water supply as a means of
isolating the supplies to the Mixing Valve for servicing and/or maintenance
work.
It is essential that all pipe work is flushed through to remove debris and
swarf that could otherwise damage the unit. Once the pipe work has been
flushed through, turn o the water supplies at the stop/service valves.
The supplied filter washers supplied must be fitted into both inlets.
The connecting pipe work must present 1/2 BSP connectors to the male thread on
the inlet connections.
Important: The pipe work must run as straight as possible to the Mixing Valve
minimising 90º angled bends as this could aect the inlet pressure to
the Mixing Valve reducing performance.
Pumped Inputs
It is possible to use a pump to boost a low pressure system to meet the inlet
requirements.
Note: The pump must be a Bristan Twin-End Negative Head Pump - ST NHPUMP
18TN.
Pump installation must be in accordance with the Fitting Instructions supplied with
the pump.
The Negative Head Pump is required to maintain the 0.5 bar minimum static
pressure requirement.

8Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Electrical Requirements
Power Rating: 240V AC / 12V DC
The Electrical Installation and Circuit Protection of this shower must comply with
current I.E.E Wiring Regulations (BS 7671) and Building Regulations (Part P).
All products manufactured and supplied by Bristan are safe provided they are
installed, used correctly and receive regular maintenance in accordance with these
instructions.
This product must not be modified in any way as this will invalidate the guarantee.
Ensure an electric socket is near the place of installation and can be reached by the
power cord. If a socket needs to be installed, please seek the services of a qualified
electrician.
Warning: Only the power adaptor supplied
with this product must be used
If you are in any doubt about your ability to install this product safely please seek
the services of a qualified plumber.

Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors. 9
Hot Cold
Out
Mounting
Find a suitable place for the mixer unit.Find a suitable place for the mixer unit.
It must be no further than 1.2m awayIt must be no further than 1.2m away
from a socket & nofrom a socket & no
further than 3m from where thefurther than 3m from where the
interface unit will be installed.interface unit will be installed.
Mark hole & drill, fix the mixer unit toMark hole & drill, fix the mixer unit to
surface using suitable screwssurface using suitable screws
(not supplied).(not supplied).
Insert the filters &Insert the filters &
connect the waterconnect the water
supplies.supplies.
Connect outlet feed.Connect outlet feed.
Plug powerPlug power
supply cable intosupply cable into
power socket &power socket &
mixer unit. Plugmixer unit. Plug
in the interfacein the interface
unit cable.unit cable.
REMEMBER
Mixer unit must
be installed
flat on floor or
on a wall with
outlets facing
down
REMEMBER
To flush the
pipe work
before
connecting
REMEMBER
To chase the
cables down
the wall to
interface unit.
PowerPower
CableCable
InterfaceInterface
CableCable
4
3
2
1
IMPORTANT
Rear access
will be required
for future
service and
maintenance.
IMPORTANT
Fit isolation
valves for
future service
and
maintenance.
Installation - Mixer Unit

10 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Installation - Wall Outlet
Choose the location for the wall
outlet and create a
25-30mm hole in the wall.
Ensure your shower accessories
have enough reach from that
position.
Screw the wall outlet into
the 1/2” female connection,
using a suitable thread sealant
ensuring the rubber seal is fitted
to the back of the wall outlet.
Fitting a 1/2” female
connection at the hole
in the wall
(not supplied).
Installation - Interface Unit
Install the outletInstall the outlet
andand
finish the wallfinish the wall
surface. Oncesurface. Once
finishedfinished
silicone around thesilicone around the
Interface unit.Interface unit.
2
1Install suitable batonsInstall suitable batons
(if required) into the(if required) into the
cavity. Punch out section incavity. Punch out section in
top left for the cable.top left for the cable.
Thread interface cableThread interface cable
through hole & plug intothrough hole & plug into
Interface unit.Interface unit.
Interface unit
can be fixed
between tiles
& siliconed
into place
4
3
Mark the position of theMark the position of the
mounting box; drill, plugmounting box; drill, plug
hole to suit & fixhole to suit & fix
using suitable screws.using suitable screws.
(Not supplied)(Not supplied)
Fix the Interface unitFix the Interface unit
to the mounting boxto the mounting box
by tightening grubby tightening grub
screws with 1.2mmscrews with 1.2mm
hex key.hex key.

11
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Operating the Shower
On Mode
1. Pause - Press once to pause for 5 minutes, for memory setting press and hold.
2. Increase Flow Rate - To increase the flow rate by 1lpm press once, to
continuously increase the flow rate press and hold.
3. Decrease Flow Rate - To decrease the flow rate by 1lpm press once, to
continuously decrease the flow rate press and hold.
4. Increase Temperature - To increase the temperature by 1C press the red
droplet once, to continuously increase the temperature press and hold.
5. Decrease Temperature - To decrease the temperature by 1C press the blue
droplet once, to continuously decrease the temperature press and hold.
1
.
2.
3.
4.
5
NOTE
When the
shower is on
the interface
unit will be
lit up.

12 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Operating the Shower
O Mode (User Setting Memory/Cleaning)
1. Start - Press once, for start up press and hold.
2. Maximum Flow Rate - Press once.
3. Eco Flow Rate - Press once, for cleaning function press and hold.
4. Thermal Disinfection - Press and hold right droplet.
1
.
2.
3.
4.
NOTE
When the
shower is o
the interface
unit will not
be lit up.

13
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
System Set Up
User Customisation
Press & hold the On/O buttonPress & hold the On/O button
until the control keys light upuntil the control keys light up
to save settings.to save settings.
Whilst the shower is onWhilst the shower is on
select the desired flow,select the desired flow,
temperature using thetemperature using the
plus, minus & dropletplus, minus & droplet
icons.icons.
Ensure the shower is inEnsure the shower is in
o mode, Continuallyo mode, Continually
hold the Start button.hold the Start button.
Allow the shower to runAllow the shower to run
water through.water through.
12
NOTE
This shower
has a memory
setting so you
can have the
perfect shower
every time.

14 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Maintenance
2Clean filters underClean filters under
cold running watercold running water
& reverse step 1.& reverse step 1.
Filters
Thermal Disinfection
General Cleaning
Monthly Cleaning Program
1
1
Isolate the waterIsolate the water
supplies & unscrewsupplies & unscrew
connections.connections.
Remove bothRemove both
filters.filters.
Ensure theEnsure the
shower is in oshower is in o
mode,mode,
continually holdcontinually hold
the minus button.the minus button.
Leave shower toLeave shower to
clean itself.clean itself.
Ensure the shower isEnsure the shower is
in o mode,in o mode,
continually hold thecontinually hold the
right handright hand
droplet button.droplet button.
Thermal disinfectionThermal disinfection
takes 5 minutes.takes 5 minutes.
Do not use abrasive cleaners or solvents to clean this unit. The interface unit should
be cleaned with a soft, clean, damp cloth.
1
IMPORTANT
Isolate the
water supply
before
starting!

15
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Spare Parts
Guarantee
At Bristan, we want to make things as easy as possible for our
customers. That’s why we oer solid guarantees on all our
products, eective from the date of purchase, to give you peace of
mind.
To start your free guarantee simply scan the QR code
and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on
0330 026 6273 where our expert team of advisors
will be able to oer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/
guarantees.
To replace any spare parts for your shower why not scan
the QR code and search for your product.

Bristan Group Ltd.
Birch Coppice Business Park
Dordon
Tamworth
Staordshire
B78 1SG
Web: www.bristan.com
Email: enquire@bristan.com
Issue: B
Part Number: WV DVO BC
Table of contents
Popular Controllers manuals by other brands

Mitsubishi Electric
Mitsubishi Electric FX3G-8AV-BD installation manual

National Instruments
National Instruments 187970E-01 installation guide

OAK
OAK SCSI 4 user guide

HPControl
HPControl A80 user manual

Mitsubishi
Mitsubishi MELSEC Q Series Structured programming manual

TyloHelo
TyloHelo 1601-40 operating instructions