manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BROAD Clean Air
  6. •
  7. Respiratory Product
  8. •
  9. BROAD Clean Air AirPro Mask FB2 User manual

BROAD Clean Air AirPro Mask FB2 User manual

Popular Respiratory Product manuals by other brands

Dräger PSS Series Instructions for use

Dräger

Dräger PSS Series Instructions for use

ResMed MIRAGE SWIFT II 60891/1 user guide

ResMed

ResMed MIRAGE SWIFT II 60891/1 user guide

Omron COMP A-I-R NE-C801 instruction manual

Omron

Omron COMP A-I-R NE-C801 instruction manual

Ombra 63506 Instructions for use

Ombra

Ombra 63506 Instructions for use

Lotus M-9520A quick start guide

Lotus

Lotus M-9520A quick start guide

CERES nosko nebulizer kit manual

CERES

CERES nosko nebulizer kit manual

Dr.Frei NE-SM1 user manual

Dr.Frei

Dr.Frei NE-SM1 user manual

North 5400 series instruction manual

North

North 5400 series instruction manual

John Bunn Neb-u-Lite LX2 user manual

John Bunn

John Bunn Neb-u-Lite LX2 user manual

Philips Respironics EE Leak 1 AF541 Instructions for use

Philips

Philips Respironics EE Leak 1 AF541 Instructions for use

Sperian Panther Hip-Pac P9684 Series Operation manual

Sperian

Sperian Panther Hip-Pac P9684 Series Operation manual

Dräger X-plore 6570 quick start guide

Dräger

Dräger X-plore 6570 quick start guide

3M 8000 Series quick start guide

3M

3M 8000 Series quick start guide

Respironics SideStream HS860 Instructions for use

Respironics

Respironics SideStream HS860 Instructions for use

Sundstrom SR 500 Instructions for use

Sundstrom

Sundstrom SR 500 Instructions for use

Ambu SPUR II Instructions for use

Ambu

Ambu SPUR II Instructions for use

BLS 8000 Instructions for the use

BLS

BLS 8000 Instructions for the use

Dräger saver PP Series Instructions for use

Dräger

Dräger saver PP Series Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Filter PM2.5 by 99.9%
Model : FB2
AIRPRO MASK
BROAD Clean Air Product AirPro Collection
Today, there are many kinds of wearable products in the world to counter dirty air, but few
of them are truly useful. The BROAD AirPro Mask is an ultra-light rechargeable HEPA filter that
everyone can afford. It can filter PM2.5 by 99.9%, protecting people from air pollution
anywhere. In addition, it can increase breathing volume, and make people feel more
refreshed and energetic. The compact BROAD AirPro Mask provides a shelter from the
smog, and can be relied on by miners, construction workers, and others who work in a
polluted environment. It can also protect medical staff from infectious diseases, and offers
great hope for respiratory patients
Get rid of air pollution in any polluted environment
AIRPRO MASK
Onsite work
Welders
Miners
Renovation workers
Hospitals
Doctors
Nurses
Respiratory
patients
Sports
Running
Cycling
Fitness & Exercise
Smoggy Days
Outdoors
Indoors
In-vehicle
Sales:400-677-6666 Service:400-883-9333
www.broadair.net BROAD Town, Changsha, China
Auto particle-filtering respirator
Standard: GB2626-2006 KN95
Protection for renovation workers,
welders and miners against silicosis,
Prevention of cross-infection in hospitals,
Protection for joggers against exhaust fumes.
Air tube x 1 set
Mask x 1
Mask joint x 2
USB cable x 1
(adaptor for mobile
phone charging device)
Lanyard x 1
Velcro x 1
Standard Accessories
Air Volume Adjustment
(press the power switch for 2 secs to turn on )
HEPA Filter Replacement
(after shutdown and power off)
battery indicator
air tube
mask joint
battery case
protruding tab
mask
cover
power switch
(3 levels)
USB port
(DC 5V charging)
Structural Diagram
active carbon filter
(optional)
HEPA H13 Filter
99.95%
fresh air
fan
Troubleshooting
4
5
3
1
2
The fan does
not work
Insufficient
air volume
Charging
failure
The HEPA filter
does not fit
The air tube
is leaking
The circuit board or USB cable
or adapter is damaged
The HEPA filter is backward
Replace it
The HEPA filter is blocked
Replace or repair it
Put the protruding tab
side upwards
Replace the HEPA filter
No.
Solution
Cause
Problem
· Remove the battery separation film before
use for the first time
· Level 1 and Level 2 are for daily use
· Level 3 for physical labor and sports
· Suggestion for first time wearing: run the AirPro
for 1~2 hours to sufficiently clean out before
wearing (with air tube and mask connected)
Mask Replacement
· Prepare a new mask and draw a �12~14mm
circle on the left or right side near the nostril
· Fold the circle in half and cut the hole with scissors
· Connect the mask to the mask joint and air tube
Regular Wearing Method
· Attach the AirPro to the lanyard and hang it
on your chest, put on the face mask with the
air tube connected
· When the outdoor temperature is low, the
main unit should be put in the pocket or hung
on the chest to reduce the discomfort caused
by cold air
· You can also remove the lanyard from the
Velcro and attach the Velcro to your helmet
for easier work
Parameter Table
3.7V lithium battery
4
1.3
33
3
0.9
30
2
0.6
27
m3/h
dB(A)
W
Battery
Filter PM2.5 by 99.9%
Item
Level 1
Level 2
Level 3
Air Volume
Power
Noise
Filtration
Efficiency
· When the air volume is less than 70%, the HEPA
filter needs to be replaced
· Replace the HEPA filter: Open the cover, take
out and replace the HEPA filter. The HEPA filter
should be replaced after 500 hours of use.
When installing the HEPA filter, the protruding
tab must point upward, otherwise the HEPA
filter will not fit
· Activated carbon is useful for absorbing toxic
chemical fumes or gas, but it is very thin and
easy to saturate. It should be replaced after
100 ~ 200 hours of use. For painters and
renovation workers, replace every 2~5 days
· The mask needs to be cleaned or replaced if
it is dirty
Maintenance
· Replace the HEPA filter when needed
· Keep the AirPro away from liquid, and avoid
exposure to rain
· Avoid hitting, dropping or impacting the AirPro
· Design life: 20 years (the bearing may need to
be replaced during this period)
Name: AirPro Mask
FB2
Model:
Serial Number:
Date of Purchase:
Shop:
Inspector:
Seller:
Quality Certificate/ Warranty Card
Warranty
· 1-year warranty from the date of purchase. For
problems caused by design, manufacturing or
transportation from factory, free repair or
replacement will be provided
· If the user is unable to provide a valid proof of
purchase, the warranty period should be
extended by 3 months from the date of
production shown on the unit
· If the AirPro was damaged due to inappropriate
use or storage, or the sticker was torn off, there
will be a charge for repair
The fan or circuit board is damaged,
the battery is dead, or the battery
separation film is not removed
Repair or replace it, charge the
battery or remove the battery
separation film
The air tube is aged or broken