May, 2011 Brooks®1250-55 Series Flowmeters
Brooks®Models 1250-55
Standard glass tube flowmeters are available in various
ranges and configurations. The meters have 65
millimeter and 150 millimeter reference scales, and are
supplied with flow curves for air and water. At your
request, flow curves for other gases and liquids can be
supplied, and direct read scales are available on a
special order basis.
UNPACKING
Precautions have been taken to prevent any damage
from occurring during shipment. However, if the meter
is received damaged, report it to the carrier
immediately. Verify that you have the model and flow
range that you require.
MILLIMETER REFERENCE SCALES
To ensure accurate flowrate readings on all flowmeters
with millimeter reference scales, the following should be
verified: the tube part number and revision level printed
on the top of the tube (for example, 1G04 R4) should
correspond with the tube number and revision level on
the Flow Curve Data Sheet. The gas or liquid flowing
through the meter and the float material should also
match the specification on the Flow Curve Data Sheet.
ACHIEVING ACCURATE FLOWRATES
To obtain an accurate flowrate, the float must be read
from the center of the ball. Additionally, the flowmeter
should be installed in a manner, which minimizes both
external vibrations and internal flow variations. Special
care should be taken so that the connections to the
meter's inlet and outlet fittings do not overly restrict the
liquid or gas flow being metered. This could result in a
reduced flow volume, preventing the meter from
reaching its maximum flowrate. Furthermore, internal
pressures could be affected, which can cause
inaccurate flow readings. Prior to use, any air/gas
trapped in the meter should be slowly purged and the
meter should be checked for leaks.
INSTALLATION
The flowmeter is capable of being panel mounted or
mounted on a leveling tripod base. In order to mount
the meter on a panel, two clearance holes must be
drilled. (Refer to Figure 1 for the correct locations of the
19/32" diameter clearance holes.) The meter is
secured to the panel using the pal nuts, which are
supplied with the meter. The meter can also be
mounted on an optional leveling tripod base for
freestanding use. The meter is supplied with 1/8-27
FNPT non-rotating fittings. When installing the fittings
the meter, place the appropriate size wrench on the hex
to prevent the inlet and outlet fittings from rotating.
(Use pipe thread sealant or Teflon®tape to achieve a
positive seal.) When installing the 1/8-27 MNPT fittings
into the meter, torque to 60 in-lbs. maximum. Failure to
hold the inlet/outlet fittings or over-torquing the fittings
could cause serious damage to the fittings or the meter
backplate.
CLEANING
Occasional cleaning may be required if dirt appears in
the flow tube or if float movement becomes restricted.
The tube assembly can be removed from the meter
frame for cleaning or replacement of parts without
removing the meter from the process line. The tube
and float should be cleaned with a mild liquid detergent
and a soft brush or swab. All pieces should be rinsed/
flushed with clean water, and dried thoroughly with
clean dry air or nitrogen.
DISASSEMBLY
If the meter is to be disassembled for any reason; be
sure to first bleed off any pressure in the meter. With a
5/32" Allen wrench, turn the jackscrew counter-
clockwise until it reaches a stop. Gently remove the
tube assembly from the meter frame. Remove the lens
caps and shield. Remove the top float stop and the
float from the top of the tube. Next, remove the bottom
float stop from the bottom of the tube. To remove a
control valve, turn counter-clockwise with a ½" wrench.
REASSEMBLY
Check to make sure that all parts are clean and dry.
Install the bottom float stop into the bottom of the flow
tube. Install the ball float and the top float stop from the
top of the tube. Install the bottom lens caps on the
tube. Insert the tube in the lens shield and install the
top lens cap. Check the top and bottom gaskets and
replace, if necessary. Carefully slide the tube assembly
back into the meter, making sure that it is properly
aligned with the scale facing forward. Tighten the
jackscrew by turning clockwise until the gaskets make
contact with the tube. Carefully torque to 1-1¾ in-lbs. to
achieve a positive seal. Do not over-tighten. To
replace a control valve, turn clockwise with a ½" open-
end wrench. Close the valve and slowly pressurize the
meter. Check for leaks before resuming operation.
Brooks®1250-55 Series Flowmeters
Installation and Operation Manual
X-VA-1250-55 Series-eng
Part Number: 541B164AAG
May, 2011
Figure 1 Dimensions for Brooks 1250-55 Series Flowmeters
Due to Brooks Instrument’s continuous improvement of our products, all specifications are subject to change without
notice. When ordering parts please include part description, item number (see Figure 2) and type of material required.
If you have any questions regarding installation, maintenance, replacement or use of this flowmeter, please visit our
website at www.BrooksInstrument.com for Customer Service contact information.
Figure 2 Parts List for Brooks 1250-55 Series Flowmeters
Number Description
1 Frame Assembly
2 Tube Assembly
3 Lens
4 Lens End Cap(s)
5 Fitting
6 Jack Screw O-ring
7 Jack Screw
8 Jack Plug
9 Jack Plug O-ring
10 Top Gasket
11 Bottom Gasket
12 Retaining Clip
13 Optional Valve
14 Valve Knob
15 Valve O-ring
16 Panel Nuts
SPECIFICATIONS
ACCURACY: ± 10% Full Scale – 65 mm
± 5% Full Scale – 150 mm
FLOATS:
Black Glass Ball Float
Sapphire Ball Float
Stainless Steel Ball Float
Tungsten Carbide Float
Tantalum Float
FRAME BACKPLATE: Anodized Aluminum
END BLOCKS AND
ELASTOMERS:
Aluminum with Buna-N
Brass with Buna-N
Stainless Steel with Viton®
fluoroelastomer
FITTINGS: ⅛-27 FNPT Fittings
GLASS TUBE: Precision Formed Borosilicate
MAXIMUM
TEMPERATURE: 200°F (93 °C)
MAXIMUM
PRESSURE: 200 PSI (13.8 Bar)

Other Brooks Measuring Instrument manuals

Brooks MT3809G Metal Tube User manual

Brooks

Brooks MT3809G Metal Tube User manual

Brooks 5850 S User manual

Brooks

Brooks 5850 S User manual

Brooks 5851E User manual

Brooks

Brooks 5851E User manual

Brooks GT1600 User manual

Brooks

Brooks GT1600 User manual

Brooks MT 3809 User manual

Brooks

Brooks MT 3809 User manual

Brooks Glass Tube Full-View 1110 User manual

Brooks

Brooks Glass Tube Full-View 1110 User manual

Brooks SLA5850 User manual

Brooks

Brooks SLA5850 User manual

Brooks 5860i User manual

Brooks

Brooks 5860i User manual

Brooks 4850 User manual

Brooks

Brooks 4850 User manual

Brooks MT3809G Metal Tube Owner's manual

Brooks

Brooks MT3809G Metal Tube Owner's manual

Brooks Ar-Mite MT3750 User manual

Brooks

Brooks Ar-Mite MT3750 User manual

Brooks 1307 User manual

Brooks

Brooks 1307 User manual

Brooks SLA5850 User manual

Brooks

Brooks SLA5850 User manual

Brooks 0254 User manual

Brooks

Brooks 0254 User manual

Brooks SLAMf50 User manual

Brooks

Brooks SLAMf50 User manual

Brooks HART MT3809G Series User manual

Brooks

Brooks HART MT3809G Series User manual

Brooks MT3809G Metal Tube User manual

Brooks

Brooks MT3809G Metal Tube User manual

Brooks Sho-Rate 1350E User manual

Brooks

Brooks Sho-Rate 1350E User manual

Brooks Quantim QmB Series User manual

Brooks

Brooks Quantim QmB Series User manual

Brooks Smart Series User manual

Brooks

Brooks Smart Series User manual

Brooks 5861E User manual

Brooks

Brooks 5861E User manual

Brooks GF Series Owner's manual

Brooks

Brooks GF Series Owner's manual

Brooks 5863 User manual

Brooks

Brooks 5863 User manual

Brooks SLA5850 User manual

Brooks

Brooks SLA5850 User manual

Popular Measuring Instrument manuals by other brands

GeoMax ZIPP10 pro series quick guide

GeoMax

GeoMax ZIPP10 pro series quick guide

ATP ATP Instrumentation Ltd ET-935 user manual

ATP ATP Instrumentation Ltd

ATP ATP Instrumentation Ltd ET-935 user manual

PCB Piezotronics M352C67 Installation and operating manual

PCB Piezotronics

PCB Piezotronics M352C67 Installation and operating manual

Innolas Laser nanio Series User and installation manual

Innolas Laser

Innolas Laser nanio Series User and installation manual

Bender ISOMETER iso1685DP manual

Bender

Bender ISOMETER iso1685DP manual

Extech Instruments MO50 user guide

Extech Instruments

Extech Instruments MO50 user guide

Sungrow PC-4 user manual

Sungrow

Sungrow PC-4 user manual

Zico ZI-9940 Operating	 instruction

Zico

Zico ZI-9940 Operating instruction

JFA Electronicos VS5HI instruction manual

JFA Electronicos

JFA Electronicos VS5HI instruction manual

AXE MMX-L manual

AXE

AXE MMX-L manual

Duratool D03121 quick guide

Duratool

Duratool D03121 quick guide

City Theatrical RadioScan 5988 user manual

City Theatrical

City Theatrical RadioScan 5988 user manual

Tektronix P2100 instructions

Tektronix

Tektronix P2100 instructions

Aeotec DSB28-ZWAU user manual

Aeotec

Aeotec DSB28-ZWAU user manual

Tegam Advanced Energy GEMINI 5540A Operation manual

Tegam

Tegam Advanced Energy GEMINI 5540A Operation manual

Leica TPS1200+ Series Field manual

Leica

Leica TPS1200+ Series Field manual

Thermo Orion Star user guide

Thermo

Thermo Orion Star user guide

BBC MA 4S user manual

BBC

BBC MA 4S user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.