fire products and solutions
Model EIB605C Photoelectric
!Interconnect up to 12 battery powered alarms
!Optional upgrade to interconnect
!Early detection to all standard domestic fires types
!Built-in high audibility warning sounder
!Large Easy to use Test/Hush button
!Hush Feature allows nuisance alarm control
!Easy to install twist-on base design
!Aesthetically pleasing, compact design
!Innovative and robust optical chamber design
!Low battery warning
!Manufactured in Ireland to ISO 9001:2000
!Certified to AS3786
!EN 14604:2005 3rd party approved
!5 year Guarantee
Product Description
The EIB605C is an Photoelectric (Optical) Smoke Alarm
using the light scatter principle, giving a quick response
to all standard fires. It’s powered by a 9V replaceable
alkaline battery (supplied with the alarm)
The EIB605C is designed for simple installation,
commissioning and maintenance
The EIB605C has a large, easy to use, combined
Test/Hush button enables full testing of the alarm and
the ability to silence nuisance alarms.
The EIB605C has an innovative high performance optical
chamber with integral fixed insect screen reducing the
possibility of nuisance alarms.
The EIB605C maybe hardwire interconnected to twelve
battery powered alarms enabling all alarms to sound if
just one of the interconnected alarms should be
triggered.
The EIB605C modular design allows it to be upgraded
for functionality with the addition of the
EIB605MRF Radio frequency module.
Operation
!The smoke detector will activate the built in sounder
upon sensing smoke particles. It will automatically
reset and silence the alarm when the smoke
particles are no longer present in the chamber.
!The red indicating LED will flash once every 40
seconds to show that the alarm is powered and it
has performed an automatic self-test.
!The built in sounder will provide a minimum sound
output of 85dB at 3m.
!Pressing and holding the “Test/Hush” button will
perform a self test and sound the horn – checking
the chamber, electronics and horn.
!Momentarily pressing the “Test/Hush” button when
an alarm is sounding will set the alarm into “HUSH”
mode. This reduces the sensitivity for a period of 10
minutes, after which the alarm automatically resets –
providing control over nuisance alarms.
!The smoke detector will emit a beep every 40
seconds to indicate that the battery is near depletion
and needs replacing.
9V Battery Powered
Communication Capability
Australia Head Office: 4 Pike Street Rydalmere NSW 2116
Ph+61 2 9684 1466 Fx+61 2 9684 4146 Toll Free 1300 78 FIRE
New Zealand Unit 106, The Zone, 23 Edwin Street Mount Eden 1024
Ph+64 9 638 4644 Fx+64 9 6384645 Toll Free 0800 220 007
AUS Web:www.brooks.com.au NZ Web:www.brooks.co.nz
E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice. EIB605C 191110
Sydney - Melbourne - Adelaide - Brisbane - Perth - Hobart - Darwin - New Zealand
fire products and solutions
Model EIB605C Optical
Installation & Placement
Alarms should be placed in accordance with the general guidelines shown in
the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector
Please consult the Instruction Leaflet supplied with the EIB605C for detailed
instructions as to how to correctly install and position the smoke detector
Important Precaution:
Do not install the actual smoke/heat
alarm itself in new or renovated
buildings until all work is completed
(including floor coverings) and the
building has been fully cleaned.
(Excessive dust and debris from
building work can contaminate the
smoke chamber and cause problems,
and it will also invalidate the guarantee).
If it must be installed, cover it
completely, particularly around the
edges, with a dust cover (eg. a plastic
bag), until all cleaning is finished..
Specifications are subject to change
Technical Specification
Sensor: Optical, uses light scatter from
smoke particles
Sensitivity: Complies with the requirements of
BS EN 14604: 2005
Airspeed: Essentially immune to the effect
of airspeed.
Button Test: Simulates the effect of smoke to
check the chamber, electronics
and horn.
Hush: Silences nuisance alarm.
Automatically resets after
approximately 10 minutes.
Supply Voltage: 9V Battery
Power-On Indicator: Red LED flashes through cover
every 40 seconds
Alarm: Piezoelectric-horn (built-in)
Alarm Sound Output: 85dB (minimum) at 3m
Temperature Range: 0 to 40°C
Humidity Range: 15% to 95% Relative Humidity –
non condensing
Interconnect: Hardwire interconnect up to 12
battery powered alarms.
A combination of up to 12 battery
and Mains powered alarms maybe
interconnected.
Fixing: Screw fixings supplied
Dimensions: 115mm (diameter) x 45mm
(height)
Weight: 200 grams
Warranty: 5 year (limited) warranty
Approvals: Certified to AS3786
VdS approved to
BS EN14604:2005, CE approved,
Manufactured to ISO 9001:2000
quality standards.
Specifications are subject to change

Other Brooks Smoke Alarm manuals

Brooks firetracker FT1020G3 FDCIE User manual

Brooks

Brooks firetracker FT1020G3 FDCIE User manual

Brooks EIB140e Series User manual

Brooks

Brooks EIB140e Series User manual

Brooks Firetracker FT1-SB User guide

Brooks

Brooks Firetracker FT1-SB User guide

Brooks EIB605 User manual

Brooks

Brooks EIB605 User manual

Brooks EIB170RFAU Instruction sheet

Brooks

Brooks EIB170RFAU Instruction sheet

Brooks RFP6 User guide

Brooks

Brooks RFP6 User guide

Brooks Electronics EIB603CX User manual

Brooks

Brooks Electronics EIB603CX User manual

Popular Smoke Alarm manuals by other brands

CALECTRO UG-5-AFR-24V UNIGUARD SUPERFLOW manual

CALECTRO

CALECTRO UG-5-AFR-24V UNIGUARD SUPERFLOW manual

Alecto SA-50 user manual

Alecto

Alecto SA-50 user manual

Visonic SMD-429 PG2 Series Installation and operating instructions

Visonic

Visonic SMD-429 PG2 Series Installation and operating instructions

Gentec-E PH100-Si user manual

Gentec-E

Gentec-E PH100-Si user manual

COBJECT SMOCKEO Operation manual

COBJECT

COBJECT SMOCKEO Operation manual

Bellman & Symfon VISIT BE1551 user guide

Bellman & Symfon

Bellman & Symfon VISIT BE1551 user guide

Alecto SA-41 instructions

Alecto

Alecto SA-41 instructions

Bosch D7050 installation instructions

Bosch

Bosch D7050 installation instructions

olympia electronics BS-655 manual

olympia electronics

olympia electronics BS-655 manual

Alecto DOM011 instructions

Alecto

Alecto DOM011 instructions

Edwards SIGA-270 manual

Edwards

Edwards SIGA-270 manual

Det-Tronics SmokeWatch U5015 instructions

Det-Tronics

Det-Tronics SmokeWatch U5015 instructions

GE ESL 700 Series installation instructions

GE

GE ESL 700 Series installation instructions

PSA LIFESAVER LIFPE10LP manual

PSA

PSA LIFESAVER LIFPE10LP manual

First Alert SC7010B user manual

First Alert

First Alert SC7010B user manual

careium i10 user guide

careium

careium i10 user guide

Unite 7885653303 user manual

Unite

Unite 7885653303 user manual

System Sensor OSI-RIE Series Installation and maintenance instructions

System Sensor

System Sensor OSI-RIE Series Installation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.