manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Brunton
  6. •
  7. Measuring Instrument
  8. •
  9. Brunton Sherpa Use and care manual

Brunton Sherpa Use and care manual

Calibrating / Using the BRUNTON SHERPA
FIRST TIME SETTING - The SHERPA has a setting in the BARO mode and in the ALT mode that must
be set before using the SHERPA for the first time.
BARO Mode Setting
1. Scroll to BARO mode.
2. Press and hold the "SET" button until the display disappears (approximately 3 seconds), then release.
3. A flashing altitude value indicates the SHERPA is waiting for a change.
4. Change value by pressing the "UP/DOWN" button until it reaches the altitude at your location.
* If your altitude is unknown, press "UP" button one time, and the SHERPA jumps to a calculated altitude.
* Remember, or document the setting value.
ALT Mode Setting
1. Scroll to ALT mode.
2. Press and hold the "SET" button until the display disappears (approximately 3 seconds), then release.
3. A flashing altitude value indicates the SHERPA is waiting for a change.
4. Match this altitude value with the altitude setting in the BARO mode.
Your SHERPA in now ready for use!
Note: The SHERPA uses pressure to calculate altitude. As the pressure changes so will the altitude, even
if the SHERPA has not been relocated. See page 7 in the instruction manual. In a day, it is common for
the altitude value to change by as much as 100 meters (approx. 300 ft.), due to a Low/High pressure system
coming into the area.
Hint: Document the pressure before heading out. In BARO mode, watch the changes in pressure using
the pressure history "bars". Each "bar" is divided into sections, and each "section" represents 2 mbars (2
hPa). Example: If the -2h history "bar" has 5 "sections" and the 0h history "bar" has 4 "sections" this
indicates the pressure has dropped by 2 mbars. Now use the correlation on page 7 in the instruction manual
(change of 1 mbar correlates to a change in 8 meters). Since the pressure dropped by 2 mbars, the altitude
will have increased by 16 meters. If the pressure changes drastically, you may want to reset the altitude in
the ALT mode.
RECALIBRATING THE PRESSURE SENSOR - If you have problems with altitude value, or the pressure
value not reading correctly, your calibration setting may have been adjusted accidentally.
1. Scroll to ALT mode.
2. Press and hold the "RIGHT" button until the display disappears (approximately 10 seconds), then
release.
3. A flashing pressure value indicates the SHERPA is waiting for a change.
4. Change this to 0.0 hPa (0.0 mbar).
If you make changes in this mode, you will have to reset the BARO, then the ALT mode again.
CHANGING TIME 12H / 24H
1. Scroll to ALT mode
2. If the altitude units are in feet, the SHERPA displays time in a 12 hour format.
3. If the altitude units are in meters, it displays time in a 24 hour format.
ROTATING THE WIND IMPELLER
It is possible to rotate the small impeller, which will protect the impeller form dirt and debris. When ready
to measure wind speed, just rotate until the wind has a straight line of sight through the instrument.
BRUNTON SHERPA
Technical Specifications
Altitude Display: 0-9,000 m (0-30,000 ft.)
Altitude Display Resolution: 1 meter (3 feet)
Update Rate of Altitude Display: Dependent rate of decent (1 or 10 sec.)
Air Pressure Display Resolution: 1 hPa or 0.01 inHg
Air Pressure Adjustment Range: 900 - 1100 hPa (26.60 - 32.49 inHg)
Update Rate of Air Pressure Display: 4x per hour
Accuracy of Wind Measurement: 4% (can be corrected)
Windspeed Display Resolution: 0.1 m/s
Windspeed Measurement: 0.1 m/s to 40 m/s (145 km/h)
Update Rate of Wind Measurement: 1x per second
Time for Average Windspeed: 5 to 60 seconds (5 sec. Incr.)
Accuracy of Temperature Measurement: +/- 2 degrees C
Temperature Display Resolution: 1 degree C
Temperature Measurement Range: -20 to 55 degrees C
Weight: approximately 45g (including battery)
Size: 10.3 x 4.50 x 1.80 cm (3.93 x 1.57 x 0.70 in.)
Casing: ABS
Battery Type: 3V lithium, CR2032
Battery Life: approximately 1 yr. - auto warning of low battery status
Warranty: 2 years
Made In: Switzerland
Copyright 2000, The BRUNTON Company

Other manuals for Sherpa

1

Other Brunton Measuring Instrument manuals

Brunton Sherpa User manual

Brunton

Brunton Sherpa User manual

Brunton Classic MM10601 Manual

Brunton

Brunton Classic MM10601 Manual

Brunton ADC Summit User manual

Brunton

Brunton ADC Summit User manual

Brunton MM-08 User manual

Brunton

Brunton MM-08 User manual

Brunton MM10602 User manual

Brunton

Brunton MM10602 User manual

Brunton Echo User manual

Brunton

Brunton Echo User manual

Brunton CM360LA User manual

Brunton

Brunton CM360LA User manual

Brunton F-5012 User manual

Brunton

Brunton F-5012 User manual

Popular Measuring Instrument manuals by other brands

B+K precision 601 instruction manual

B+K precision

B+K precision 601 instruction manual

Aquametro AMBUS IS Mounting instructions

Aquametro

Aquametro AMBUS IS Mounting instructions

seeed studio SARK-110 user manual

seeed studio

seeed studio SARK-110 user manual

Isotech PEGASUS PLUS 1200 Series Handbook

Isotech

Isotech PEGASUS PLUS 1200 Series Handbook

Digistar GT400 Operator's manual

Digistar

Digistar GT400 Operator's manual

Lightobject Ranger3 Operation manual

Lightobject

Lightobject Ranger3 Operation manual

Unit UT602 operating manual

Unit

Unit UT602 operating manual

Co2meter AQ500 manual

Co2meter

Co2meter AQ500 manual

AutoMeter 5336 installation instructions

AutoMeter

AutoMeter 5336 installation instructions

Pro's Kit MT-7025 user manual

Pro's Kit

Pro's Kit MT-7025 user manual

Axio MET AX-C705 user manual

Axio MET

Axio MET AX-C705 user manual

Co2meter TecPen MAP TS-200 O2 user manual

Co2meter

Co2meter TecPen MAP TS-200 O2 user manual

Aqualytic CHECKIT Comparator instruction manual

Aqualytic

Aqualytic CHECKIT Comparator instruction manual

In-situ Aqua TROLL 700 Operator's manual

In-situ

In-situ Aqua TROLL 700 Operator's manual

MH Corbin NC350 Operation manual addendum

MH Corbin

MH Corbin NC350 Operation manual addendum

Pro's Kit NT-6580 user manual

Pro's Kit

Pro's Kit NT-6580 user manual

Unit UTE310 quick guide

Unit

Unit UTE310 quick guide

Check-line TI-CMX user manual

Check-line

Check-line TI-CMX user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.