BRYANT DENTAL Dentair User manual

MANUAL - FOZKYGB-03
A BRYANT DENTAL PRODUCT

Combining innovative technology with outstanding design, we bring
you a sophisticated dental air purication system to ensure the highest
levels of protection and reassurance for your team and your patients.
Our world-class DentAir®system eliminates the invisible contaminants in a
room and disperses clean air that’s free from viruses, bacteria and particulates.
With its ultra-high power 24W UVC technology, 360-degree air intake and ve-
stage ltration process, it’s quick, efcient and quiet, allowing you to work safely
without disruption. Designed and developed for quality and longevity with widely
trusted technology, DentAir®gives you peace of mind, with the exceptional
levels of service you can be sure of from Bryant Dental.
Pioneering Safer Dentistry
Appliances that are obviously
damaged must not be operated.
Follow Instructions for use
before opening the appliance.
+44 (0)1932 320064 |+44 (0)7990 113723

Take out the
power cord
Installation
Unpack the product
and take out the
power cord.
Follow instructions on Page 05.
Insert UVC Bulb
Control panel
Venturi Air Outlet
Air inlets
Humidity and temperature
sensor / laser dust sensor /
TVOC odour sensor (internal)
Combined lter (internal)
Product details
at the bottom
of the unit cap
(replacement
lter)
dentair.co.uk |03
Connect the power
cord at the bottom
of the unit power
supply interface,
and then plug into
a power supply.
Turn on the power

Changing
the lters
Please use regular PPE when
changing the lters and
dispose in clinical waste.
Disconnect the power supply
and ensure the unit is off.
Turn the bottom cover anti-
clockwise to access the lters.
Disconnect the UVC bulb wire
and draw out the lters from
the unit. Remove the carbon
lter from inside the HEPA lter
before removing the UVC bulb.
Re-connect UVC bulb to the new
HEPA lter cartridge, before
replacing the carbon lter and
then insert back into the unit.
Re-connect UVC Bulb wire then
put the cover back in place and
turn clockwise to lock. Press the
sleep button for three seconds.
5
+44 (0)1932 320064 |+44 (0)7990 113723
Filters
Pre-lter
This consists of an omnidirectional
antibacterial bre mesh fabric capable
of capturing and ltering large particles
such as dust, hairs and skin akes. This
prolongs the lifespan of the HEPA lter
and improves system efciency.
ATP-HEPA antimicrobial peptide lter
High-density ATP-HEPA antimicrobial
peptide lter to remove airborne particulate
matter with a mean aerodynamic diameter
of 2.5 µm.
High-efciency activated carbon layer
This is a large honeycomb-structured
lter which works to remove harmful
substances such as mercury and benzene.
It can subsequently reduce dental odours
in the surgery.
Please visit the DentAir®website to buy
high-performance combined lters.
Pre-lter and
ATP-HEPA lter
cartridge
UVC Bulb
High-efciency
activated
Carbon lter

dentair.co.uk |05
Changing
the UVC Bulb
Re-connect
UVC Bulb wire
Turn cover
clockwise to lock
Sleep mode
(3 seconds)
Please use regular PPE when
changing the UVC Bulb and
dispose correctly.
UV radiation is dangerous for the
eyes and skin. Do not operate the
UV-C emitter outside the appliance.
Disconnect the power supply
and ensure the unit is off.
Turn the bottom cover anti-
clockwise to access the lters.
Disconnect the UVC Bulb
and then remove the lters.
Remove the UVC bulb by gently
pulling away from the cartridge
base. Insert new bulb by
inserting into the empty slots.
Re-connect UVC wire then put
cover back in place and turn
clockwise to lock. Press the sleep
button for three seconds.
5
5

+44 (0)1932 320064 |+44 (0)7990 113723
Figure
Reecting Air
Quality
PM 2.5 Inspection
Levels of air
quality
Temperature
level
Humidity
level
Light Strips
Reecting Air
Quality (ashing
if it is time
to replace
the lter)
Fan Speed

dentair.co.uk |07
Start Button
When you turn the air purier on, the start button will
turn red and go to ‘stand by’ mode. Press the button to
start the unit. When on stand by, the power consumption
is less than 2W. To shut it down completely unplug from
the power source. When in ReAKT mode, the anion
function runs automatically and the sensor begins to
inspect the unit.
ReAKT Button
When started, the air purier defaults to smart mode, then
automatically switches wind speed in accordance with the
air quality at that time. When you press another button the
unit changes from smart mode to manual.
WiFi
When you start the air purier for the rst time, press
the ReAKT button for 3 seconds and the icon on
the control panel with ash. Scan the QR code on the
unit to access the DentAir®app. Once the connection
is complete, you will be able to control the unit via
a mobile phone. When you are using this mode the
light will be on.
Screen display introduction
Wind Speed Button
Press the wind speed button on the control panel or
relevant buttons on the remote controller to set the
wind speed at low, medium, high and max and back
to low in circles. When you choose a certain speed
the corresponding indicator light will turn on.
Sleep Mode
To put the unit into sleep mode, press the sleep button
on the control panel or the remote control. During sleep
mode the air purier runs at the slowest speed and only
the sleep button will light up on the control panel.
To exit sleep mode, press any button (other than start)
and the unit will return to the previous setting.
Lock Timer
Press the timer button for 3 seconds and the red light
will come on, indicating the air purier will run in the
child lock mode. If you press the button for another
3 seconds the light will go off, the unit will exit this
mode and all other buttons will be unlocked.

+44 (0)1932 320064 |+44 (0)7990 113723
Filter replacement alert / instructions
When started, the air purier will automatically calculate the
remaining usage of the lter, according to the unit’s running
conditions and the internally stored algorithm. When the lter
needs to be replaced, the light on the panel will continuously
ash to alert you. Once you’ve replaced the lter, start the unit
and press the sleep button for 3 seconds to turn the lter light
off. The time memory will now re-set itself.
Please handle lters as medical
waste and treat accordingly.
This appliance contains a UV-C emitter.
Timer Setting
When you start the air purier, it will show the current PM 2.5
conditions on the control panel. Press the timer button and
the panel will show a string of numbers. If you select the zero,
the purier will exit timer mode and the timer light will go
off. When you’ve chosen your timing length, wait ten seconds
and the unit will switch to that mode automatically (if no other
buttons have been pressed).
User guide
Tilt Detection
If the air purier tilts at an angle of 90 degrees or more, it will
automatically power off. When placed back upright it will default
to stand by. Press the start button and if the machine enters the
smart mode then it is safe to use.

dentair.co.uk |09
H13 clean air delivery rate: 60-600m3/h*
Particulate matter CCM: P4-level
Particulate matter purication-
related energy efciency:
10.9 (high-efcient level)
Sterilization rate: 99.99%
Effective coverage area: 42-72m2
Timer settings: 1-8 hours
Fan speed settings: 1-2-3-4-Auto
Pollution-level identication: Numerical value; light strips
Remote control: ≤6m
EN 1822: Class 13 HEPA +/- Activated Carbon Filter
TUV Certied for European Low Voltage Directive
(Directive 2014/35/EU ) and the Electromagnetic
Compatibility Directive ((EMC) Directive 2014/30/EU)
Parameters
Certication
Name: DentAir®
Model: FOZKYGB-03
Rated voltage: 220V-230V
Rated frequency: 50/60Hz
Input power: 78W
Main material: Aerospace Cold-rolled Steel Housing
Dimensions: (H)800 x (W)300 mm
Sensors: Laser dust sensor / humidity and
temperature sensor / TVOC odour sensor
Net weight: 15kg
Standby-power: ≤2W
Noise level: ≤60dB (A)
Indication: LED indicators and gures
Control: Touch, remote and WiFi
DC motor: Nidec motor from Japan
Specications
Specications
*
CADR values are ±10% and given with the H13 Filter in place, values will
vary depending on wind speed settings and your chosen lter conguration.
You can use the calculator on our website www.dentair.co.uk for a guide to air changes per hour.

+44 (0)1932 320064 |+44 (0)7990 113723
Cleaning and Maintenance
Always turn off the power by disconnecting
the plug from the socket before carrying out
maintenance, cleaning or changing the fan position.
Please make sure that your air purier is completely
stopped before cleaning.
Do not attempt to clean the HEPA/Carbon lter
with a grinding sponge, scouring pad or hard brush.
Do not ush or drench the air lter.
Do not beat the air lter to clean any gathered dust.
When not in use, please store in a dry place
with good ventilation.
Please ensure maintenance work is carried
out by an authorised service centre.
If the power line or plug of the appliance
is damaged, immediately stop using.
Cleaning and user maintenance shall not
be made by children without supervision.
1
8
9
2
3
4
5
6
7

dentair.co.uk |11
Warnings
Terms and conditions
Bryant Dental will repair
any DentAir®issue arising
from a structural defect for a
period of 5 years and from an
electrical defect for a period
of 2 years, without charge.
The liability will not exceed
the amount you originally paid
for the product. The warranty
does not cover defects arising
from negligence, product
modication, unauthorised
repairs, accidental damage,
theft, loss or acts of God.
Please keep the original
purchase invoice as evidence
of purchase.
Warranty
Moving
To move your air purier ensure
it’s switched off and unplugged
from its power source.
Installation
» The air purier cannot work
if the lter cover plate is not
installed correctly.
» Always ensure the inlet is more than
20cm away from anything that could
obstruct the airflow, such as walls.
AC power cord
» Do not excessively twist, pinch,
bend or turn back the power
cord, or the wire core will be
exposed to the air or broken.
» Do not drag or pull the power
cord when unplugging.
» Do not use an AC socket that
is not compatible.
» Do not use the provided power
cord in other devices.
In use
» If the unit makes unusual sounds, smells,
overheats, or the fan rotates irregularly,
immediately turn the unit off.
» Do not insert anything into the air inlet
or outlet of the unit.
» Keep hair, fabric and other items away
from the unit as they may be sucked in,
which can cause injury, and damage to
the system.
» Do not sit on the air purifier, stand too
close to it or tilt it in any way.
» Open the ventilation system when using
with another combustion appliance in order
to prevent carbon monoxide poisoning.
Precautions
» The appliance is not to be used by persons
(including children) with reduced physical,
sensory or mental capabilities, or lack of
experience and knowledge, unless they are
supervised or have been given instruction.
» Children must not play with the
appliance and should be supervised
around it at all times.

dentair.co.uk
IFU_EN1_0/IF June 2020
Bryant Dental, The Barns, Hilltop Farm, Lyne Lane, Lyne, KT16 0AW
DentAir®and Bryant Dental®are registered trademarks in the United Kingdom and Australia.
Registered in England & Wales No. 10396020. Registered in Australia No. 634 752 980
+44 (0)1932 320064 |+44 (0)7990 113723
First Repair Record:
User Name:
Product Model:
Contact Information:
Date of Purchase:
Date of Repair:
Malfunction Information:
Repair Progress:
The Original Serial No.:
Warranty Product details
This product helps protect against certain particulate contaminants
but does not eliminate exposure to or risk of contracting disease or infection.
This manual suits for next models
1
Table of contents