Maintenance instructions
Maintaining the unit is easy. The only serviceable/changeable component is the
life of the lamp. The lamp must be changed once a year in order to ensure
ATTENTION! The UV-lamp must be allowed to cool down before cleaning.
ATTENTION! Installation & lamp replacements must be carried out by a maintenance
mechanic or apropriately qualified person only.by a maintenance mechanic or
CAUTION! Disconnect the unit from the power supply network before servicing.
Avoid touching the lamp’s glass element.
Handle the lamp by its white end caps only
Cleaning and changing the lamp
1. Disconnect the power supply to the device
2. Open the unit in accordance with the installation instructions in this manual
3. Ensure that the lamp has cooled down. Extract the lamp from its retaining
clips (see illustration M). When handling the lamp, avoid touching the glass
4a.Cleaning the lamp: Clean the lamp with a soft cloth and an appropriate
5. Close the unit in accordance with the installation instructions in this manual.
6. Connect the power.
7. When the lamp has been replaced, dispose of the old lamp in accordance
with local regulations pertaining to hazardous waste disposal. UV-lamps
contain small traces or mercury.
Troubleshooting
In the event that the undermentioned instructions do not solve the problem,
contact your supplier.
1. The fan works, but the lamp is not on
a. Check that the lamp is properly inserted into its socket
b. The lamp may be defective. Replace the lamp with a new one
2. The lamp and the fan do not function
a. Check that the device is plugged in
b. Check that the power outlet functions properly
c. Check that the power chord is undamaged
d. Check to see if the locking shank (which also functions as an ON/OFF switch)
is fully turned and properly engaged.
RoHS
This UV-lamp is intended to produce photoplasma and is not suitable for illumination.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent, or similarly qualified persons in order to avoid a hazard.
ENGLISH
UV-lamp. If the device is located in a dusty or smoke-filled area, it is recommended
that the lamp be cleaned every three months. This will significantly lengthen the
maximum functionality and efficiency.
element with exposed fingers.
cleansing solvent (i.e. isopropyl alcohol). Reinsert the lamp.
4b.Changing the lamp: Insert a new lamp (see technical specifications in this
manual for correct lamp type). Use only a new BioZone Scientific Group lamp
(using other lamps will void the warranty).
3. The airflow is weak
a. Check to see if the grill is clogged with dust or debris
b. Check for blockages to the incoming or outgoing air flow
c. Check that the fan functions properly
Disposal/recycling
BioZone Scientific Group is an ISO-14001:2004-compliant company and is
committed to environmental sustainability.
Packaging
Packing materials can be recycled. In the interest of environmental protection,
dispose of these materials properly.
The unit and UV-lamp
If your BSG AC needs to be disposed of, do so in accordance with the
instructions pertaining to standard electrical equipment. UV-lamps contain small
traces of mercury. Old, defective or broken lamps must be disposed of in
accordance with laws related to the disposal of hazardous waste.