Buffalo FS130 User manual

UVC Sterilising
Cabinets
FS130/FS131/FS132

As is the case with most sterilising equipment, the steriliser
cabinet should be used with caution. Please read the following
warnings to avoid potential injuries.
WARNING:
This appliance is intended for indoor use only.
To protect against fire, electrical hazards, and/or personal
injury, do not immerse cord, plugs or base in water or other
liquids.
Danger of serious injury or death! Do not attempt to service
this equipment unless you are a licensed electrician or trained
servicer.
Because this equipment utilizes high voltage, it should only be
installed and serviced by a licensed electrician or trained
servicer. Attempting to install or service the equipment yourself
could result in serious, potentially fatal injuries.
If an electrical shock is felt when touching equipment, shut off
power immediately (pull cord or turn off circuit breaker) and
call a trained servicer for repair. Failure to do so could result in
serious, potentially fatal injuries.
Always turn power switch off any time equipment is not in use.
: Danger of injury! Do not open door until timer
has completed countdown.
WARNING
WARNING
: Do not operate equipment with faulty, loose,
or missing parts. If you do, personal injury, or damage to
equipment and property could result.
WARNING:
could result in death.Read the installation, operating and
maintenance instructions thoroughly before installing or
servicing this appliance.
!
!
!Improper installation, alteration or service

This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children
without supervision.
This equipment is intended to be used for commercial
applications, for example in kitchens of restaurants, canteens,
hospitals and in commercial enterprises such as hotel, hospital
etc.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
WARNING - This appliance contains a UV emitter. Do not stare
at the light source.
Do not bypass the safety interlocks.
Do not use appliance for other than its intended use.
To reduce risk of explosion or fire, do not use near
combustibles.
For safe and proper operation, the appliance must be placed in
a stable, vertical position.
Always unplug from outlet prior to handling or cleaning.
The product instructions are available as a PDF document via
your Buffalo dealer.
* The instructions in this manual have not been followed correctly.
* Un-qualified personnel have adjusted the UVC Sterilizer Cabinet Frame.
* Non-original spare parts are used.
Congratulations on your purchase of your UVC Steriliser cabinet. Provided in this manual are necessary
details to ensure efficient, effective and safe operation of your new equipment while maintaining the best
possible performance. Please take time to carefully read through this manual.
BUFFALO will not accept liability for product failures in the event that:

BUFFALO prides itself on quality and service, ensuring that at the time of packaging the contents are
supplied fully functional and free of damage. Should you find any damage as a result of transit, please
contact your BUFFALO dealer immediately.
Remove the Sterilizer Cabinet unit from the packaging, ensuring that all protective packaging, plastic and
residues are cleaned from its surfaces. Layout all components of the Sterilizer Cabinet unit on the floor
ready for assembly.
Installation
\
Runner
Ladder
Runner is inserted into the ladder
All BUFFALO products are inspected and tested prior to packing.
This product consists of the following parts :
* UVC sterilizer cabinet
* FS130 - Small unit - 1 glass rack + 1 Cutlery rack
* FS131 - Medium unit - 3 glass racks + 1 Cutlery rack
* FS132 - Large unit - 3 glass racks + 2 Cutlery racks
* Instruction manual

Carbon filter needs to be replaced annually.
1.Unscrew the cover of the back panel with
a screwdriver and remove the cover.
2.Take out the filter frame rack and replace
it with a new carbon filter.
3.Turn the door over 180° and push the
door axle hole towards the hinge frame.
4.Insert the hinge frame from the upper
left corner to the bottom right and
tighten the screws.
2.Install the hinge frame from the lower
left corner to the right upper corner
and tighten the screws.
Reversing the door
Carbon filter replacing
Depending on the location of the appliance, it may be necessary to change the direction the door opens.
3.Install the filter frame back in place. 4.Put the cover back on and tighten the screws
1.Fully open the door, unscrew the hinge
frame with a screwdriver and remove
the door and hinge frame together
from the appliance.

WARNING: Read and follow installation instructions before plugging in machine.
.etalpgnitarehtnodeificepstahtnahtrehtoegatlovynaotdetcennocsienihcamfidioveblliwytnarraW
WARNING: Do not operate appliance unless all panels and access covers are attached correctly.
1.Fully open the door and remove the
lampshade by unscrewing the surface
screws with a screw driver.
3.Replace the new lamp tube, insert the
lamp holder and rotate 90° to fix the lamp
tube.
4.Install the lampshade back to its original
place and tighten the screws.
2.Hold the lamp to be replaced firmly with
your hand, rotate it 90° and pull it out.
Replacing the lamp

This appliance is intended for professional use only and should be operated by fully trained and qualified
personnel.
START/STOP button:
Press the button to start sterilizing /stop sterilizing
Digital timer:
To start sterilisation cycle and countdown timer
from 30 minuites press START
When the green light is illuminated
it is safe to open the door
Operating
Control Panel
When the red light is illuminated
the door must not be opened
5. To stop the cycle before 30 minuites press the STOP button. The timer will count down from 5
minuites to eliminate ozone in the unit and the door must remain shut. When the green light
illuminates the door can be opened.
6. When a cycle is complete the timer will default back to 00:00.
1. Connect the appliance to a mains power supply.
2. Open the door, place items that require sterilizing in and close the door.
3. Press START and the 30 min cycle will begin.
4. For the first 20 seconds of the cycle the door can be opened, after this the red light will illuminate
and the door must remain shut until the end of the cycle or the cycle is stopped.

WARNING:
!
If the supplied power cord or receptacle is damaged, it must be replaced by a BUFFALO Authorized
company technician, or a similarly qualified person in order to avoid a hazard.
It is recommended that this appliance be inspected by a qualified service technician for proper
performance and operation on a yearly basis.
Clean the outer shell of the machine with a damp cleaning cloth, wipe the surface of steel plate
or the outer surface of the machine lightly, when cleaning the shell, do not use corrosive cleaning fluid or
articles, do not use rigid cleaning appliances, so as not to scrape steel shell.
Cleaning, Care and Maintenance
The power supply must be disconnected before servicing, maintaining or cleaning this appliance.
The appliance is not jet stream approved. Do not clean the appliance with a water jet.
Never use the appliance as a step for cleaning or accessing the ventilation hood, Serious injury could
result from slips, trips or from contacting hot liquids.
8
Troubleshooting
The below charts are a guide to possible problems and causes. Please read through these and double
check any problems you may be having. The steps below will allow you to trouble shoot before placing a
service call.
• Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions or has
been dropped or damaged in any manner. Contact your Buffalo dealer for repair.
• Always unplug unit from power supply before servicing.
Fault Probable cause Action
Application
not working
The unit is not
switched on
Check the unit is plugged in correctly and switched on
Lamp has blown Replace lamp (Lamp must have a light wave length of
253.7nm, please contact Buffalo)
Plug and lead are
damaged A qualified technician should replace the power cord
Power supply Check power supply or call a qualified technician to
replace the power cord
The door is not
shut correctly
Shut the door or call a qualified technician to replace
the switch
Transformer fault A qualified technician should replace the transformer
Timer fault A qualified technician should replace the timer
No power in but the
power light on
A qualified technician should replace the mainboard
No UVC
light inside
UVC light fault A qualified technician should replace the light
Odour inside Fan fault A qualified technician should replace the fan
!WARNING:

Specifications
Compliance
Model Voltage UV Power
Dimmensions (mm)
Weight (kg)
Width Depth Height
FS130
220-240V
50Hz
8W 15W 430 480 400 18.1
FS131 2*8W 25W 430 480 825 32.1
FS132 2*15W 40W 600 600 1800 76.6
BUFFALO parts have undergone strict product testing in order to comply
with regulatory standards and specifications set by international,
independent, and federal authorities.
BUFFALO products have been approved to carry the following symbol:
All rights reserved. No part of these instructions may be produced or transmitted in any form or by any
means, electronic, mechanical, photocopying, recording or otherwise, without the prior written
permission of BUFFALO.
Every effort is made to ensure all details are correct at the time of going to press; however, BUFFALO
reserve the right to change specifications without notice.
The WEEE logo on this product or its documentation indicates that the product must not
be disposed of as household waste. To help prevent possible harm to human health
and/or the environment, the product must be disposed of in an approved and
environmentally safe recycling process. For further information on how to dispose of this
product correctly, contact the product supplier, or the local authority responsible for
waste disposal in your area.
9

@


FS130-FS131-FS132_ML_A5_v1_20210326