9307 EN - 6
General Technical Data
Sampling rate: 10 kHz
Signal sampling: ∆X, ∆Y, ∆t in any combination
Measurement curves: Y1 (X) and Y2 (X)
Digitalization: 16 bit
Evaluation time: 15 ms
Measurement programs:
32 (5,000 value pairs)* / 128 (400 value pairs)
Power supply: 90 ... 264 VAC / 47 ... 63 Hz / typically 30 VA
Delay in real-time limit signals S1 ... S4: < 10 ms
Operating temperature range: + 5 ... + 23 ... + 40°C
Protection class: IP30 / IP65 panel-mounted
Display: 5,7“ TFT LCD (640 x 480)
Keypad: numerical, congurable function keys
* Factory-installed device rmware. Firmware can be changed via
PC software DigiControl.
Compatible Sensors
Flexible assignment of physical channels A ... F to measurement
graphs (X/Y1/2 coordinates)
Channel A, B (strain gauge, potentiometer, process signals)
Strain gauge sensors
Measurement ranges: ± 1 ... 40 mV/V
Bridge resistance: 120 Ω ... 5 kΩ
Excitation voltage: 2.5 V, 5 V, 10 V
Excitation current: 35 mA or 70 mA @ 10 V
Cut-off frequency: 5 ... 5,000 Hz in discrete bands
Total error: < 0.05 % F.S. @ ≥ 1 mV/V
< 0.1 % F.S. @ < 1 mV/V
Potentiometer, process signals
Excitation voltage: 5 V / 10 V
Transmitter excitation: 24 V, 150 mA
Measurement ranges: ± 5 V, ± 10 V
Excitation current: 100 mA max.
Cut-off frequency: 5 ... 5,000 Hz in discrete bands
Total error: < 0,05 % F.S.
Channels A and B
support burster TEDS (SN 530000 onwards)
Channel C incremental sensors, EnDat 2.2, SSI
Signal: TTL / RS422, sinusoidal voltage 1 Vpp,
sinusoidal current 11 µA
Counter depth: 32 bit, ± 2EXP31
Cut-off frequency: 1 MHz
Reference mark: single, multipoint, distance-coded
Absolute value: EnDat 2.2, SSI,
reference travel for distance encoding
Transmitter excitation: 5 V, 300 mA
Channel D combined channel analog/incremental (option)
Strain gauge or process signal: ± 1 ... 40 mV/V, ± 5 V, ± 10 V
Total error: according to channels A, B
Incremental interface: TTL/RS422, Sinus 1 Vpp, Sinus 11 µA
Transmitter excitation: 5 V, 300 mA / 15 V, 200 mA
Channel E resistance measurement (option)
Measurement ranges: 200 mΩ, 2 kΩ, 100 kΩ
Total error: < 0.5 % F.S. @ 200 mΩ, 2 kΩ
< 1 % F.S. @ 100 kΩ
Channel F Piezoelectric (option)
Measurement ranges: 1 nC ... 1 µC in discrete bands
Cut-off frequency: 5 ... 5,000 Hz in discrete bands
Total error: < 1 % F.S.
Fieldbus Interfaces
I/O interface
Two parallel PLC ports to EN 61131-2, 24 VDC, opto-isolated
23 inputs D-SUB-37 (male)
31 outputs, of which 23 congurable,
maximum load IMAX 200 mA,
D-SUB-37 (female)
PROFIBUS (option)
D-SUB9
Bau drate max. 12 MBaud
Communication protocol cyclic service DP-V0
acyclic service DP-V1
PROFINET, EtherNet/IP, EtherCAT (option)
2 port western-socket (RJ45)
Communication protocol cyclical realtime process data
non cyclical parameter data
Communication Interfaces
Device parameterization, data backup (up/download), high-speed
measurement data logging
USB Slave port (model B)
front panel
Data rate ~ 1 Mbaud
RS232 D-SUB9
(PC connecting using 1 : 1 cable 9900-K333)
Format 8.1
Data rate 9600 baud ... 115.2 Kbaud
Ethernet 10/100 Mbit, Western socket (RJ45)
Housing
Combined desktop/panel-mounted housing (W x H x D):
205 x 160 x 240 [mm]
Desktop version: 4 rubberized feet (fitted as standard)
Front panel (W x H): 220 x 175 [mm]
Front panel cut-out (W x H): 206 x 161 [mm]
Weight: approx. 5 kg
Accessories
Fixing kit for panel mounting Model 9300-Z003
PC-Software
DigiControl PC software for convenient device conguration inclu-
ding backup function (upload/download), laboratory mode for manual
reading and analysis of measurement curves, and data-log wizard with
print and export functions.
Supplied with the instrument and available free of charge from
www.burster.com
DigiControl PC software including USB data cable 9900-K349
Model 9307-P101
PC software DigiControl: PLUS version including high-speed, in pro-
cess logging of measurement data, Data-log wizard, ASCII raw data,
EXCEL, PDF and SQL export Model 9307-P100
Cables and connectors
Connecting cable for burster displacement sensors
8710 ... 8719 series, length 3 m Model 99209-591A-0090030
Connecting cable for torque sensor model 8651/8661 incl. angular
measurement to option channel D, length 3 m
Model 99163-540A-0150030
Adapter cable (Y-type) for torque sensor model 8661 incl. angular
measurement to standard channels A/B and C (only to use together
with model 99163-540A-015xxxx) Model 99209-215A-0090004
Connecting plug for A, B and E channel, D-SUB-9
(pack of 2 included with device) Model 9900-V209
Connecting plug for C and D channel, D-SUB-15
Model 9900-V163
burster TEDS
Connecting plug 9-pin, Min-D including
memory chip for the transducer electronic data sheet
Model 9900-V229
Fitting the connector including programming
of the electronic data sheet 99011
Adjustment of a complete measuring chain
Adjustment and scaling of up to 3 sensors including test certicate
93ABG
Order Code
DIGIFORCE®9307 - V
Standard 0 0 0 0
Analog option
Piezo interface X 1 X X
Combined channel analog / INCR (D)
and resistance measurement (E) X 2 X X
Fieldbus option
EtherCAT X X X 1
PROFIBUS (DP-V0/DP-V1) X X X 2
PROFINET X X X 3
EtherNet/IP X X X 4