
new RIVER IDRO T2 - TESIS Airtight T2 - MIRA T2 - MAYA idroT2
2
SUMMARY
1 MANUAL SIMBOLOGY....................................3
2 PACKAGING AND HANDLING..........................3
2.1 PACKAGING .............................................................3
2.2 PREPARATION AND UNPACKING .............................3
2.3 STOVE HANDLING....................................................5
3 CHIMNEY FLUE .............................................5
3.1 PREPARING THE SMOKE EXPULSION SYSTEM.........5
3.2 CHIMNEY COMPONENTS.........................................5
3.3 SMOKE DUCT SMOKE FITTING..............................6
3.4 FLUE CHIMNEY OR PIPED DUCT ...........................6
3.5 CHIMNEY POT..........................................................7
3.6 MAINTENANCE........................................................8
4 COMBUSTION AIR.........................................8
4.1 AIR INLET ................................................................8
4.2 COMBUSTIBLE AIR INLET FOR SEALEDCHAMBER
INSTALLATION ...................................................................9
5 EXAMPLES OF INSTALLATION DIAMETERS AND
LENGTHS TO BE SIZED ......................................10
6 INSTALLATION............................................11
6.1 INTRODUCTION.....................................................11
6.2 MINIMUM DISTANCES...........................................12
6.3 OVERALL DIMENSIONS .........................................13
6.4 STOVE DOOR REMOVAL/INSTALLATION................14
6.5 MIRA 1622 TESIS 1623 AIRTIGHT FRAME
ASSEMBLY........................................................................15
6.6 FITTING THE METAL FRAME OF RIVER IDRO 162323
H2O ..............................................................................16
6.7 FITTING THE MAIOLICA FRAME OF RIVER IDRO 16
23 23 H2O.......................................................................16
6.8 MAYA IDRO 1624 FRAME ASSEMBLY...................17
6.9 ASSEMBLING TESIS 1623 AIRTIGHT.....................18
6.10 ASSEMBLING THE TOP CLADDING AND BOTTOM
DOOR ..............................................................................19
6.11 ELECTRIC CONNECTION.........................................19
7 SMOKE OUTLET CONNECTION IDRO MAYA 16 24
.................................................................20
7.1 GENERAL WARNINGS ............................................20
7.2 REAR OUTLET CONNECTION..................................20
7.3 TOP OUTLET CONNECTION IDRO MAYA 16 24 .....20
8 PLUMBING CONNECTION.............................21
8.1 PLUMBING SYSTEM CONNECTION.........................21
8.2 CONNECTION DIAGRAM RIVER IDRO 16 23 MIRA
1622 TESIS 1623 AIRTIGHT.........................................21
8.3 CONNECTION DIAGRAM RIVER IDRO 23 H2O........22
8.4 CONNECTION DIAGRAM IDRO MAYA 16 24 ........23
8.5 3 BAR DISCHARGE VALVE......................................23
8.6 WASHING THE SYSTEM .........................................24
8.7 FILLING THE SYSTEM.............................................24
8.8 WATER CHARACTERISTICS ....................................24
8.9 SYSTEM CONFIGURATION .....................................25
8.10 CONFIGURATION 1.................................................25
8.11 CONFIGURATION 2.................................................26
8.12 CONFIGURATION 3.................................................29
8.13 CONFIGURATION 4.................................................30
8.14 CONFIGURATION 5.................................................32
8.15 CONFIGURATION WITH STORAGE TANK AND
AUXILIARY WALLMOUNTED BOILER EXAMPLE...........33
8.16 OPERATING MODE.................................................34
8.17 ELECTRICAL CONNECTIONS...................................34
9 SPECIAL MAINTENANCE ..............................35
9.1 INTRODUCTION.....................................................35
9.2 FUME CONDUIT CLEANING....................................36
9.3 SMOKE EXTRACTOR COMPARTMENT CLEANING...36
9.4 CLEANING THE SMOKE EXTRACTION SYSTEM AND
GENERAL CHECKS ............................................................36
9.5 DOOR CLOSING FUNCTIONALITY PERIODIC CHECK37
9.6 FUME PASSAGES CLEANING..................................37
9.7 REPLACING THE OVERPRESSURE RELIEF VALVE FOR
THE COMBUSTION CHAMBER ..........................................38
10 BOILER HEAD CLEANING .............................39
10.1 FUME PIPES ANNUAL CLEANING ..........................40
10.2 GASKET REPLACEMENT.........................................40
11 IN CASE OF ANOMALY..................................40
11.1 PROBLEM SOLVING ...............................................40
11.2 PROBLEM SOLVING THERMOSTOVE...................43
12 TECHNICAL DATAS ......................................45
12.1 REPAIR INFORMATION ..........................................45
13 ELECTRONIC BOARD ...................................46
14 FEATURES ..................................................47