Cadel CARINA 9,5 kW User manual

©2014 CADEL srl | All rights reserved – tutti i diritti riservati
en WOOD STOVE
installation, use and maintenance manual
carina - dora

2CARINA - DORA
EN
Summary
1 MANUAL SIMBOLOGY .....................................3
2 DEAR CUSTOMER..............................................3
3 CAUTIONS.........................................................3
4 WARRANTY CONDITIONS ................................4
5 SPARE PARTS.....................................................5
6 WARNINGS FOR THE CORRECT DISPOSAL OF
THE PRODUCT...........................................................5
7 PACKAGING AND HANDLING ......................5
7.1 PACKAGING.................................................5
7.2 STOVE HANDLING.........................................5
8 CHIMNEY FLUE ................................................6
8.1 INTRODUCTION.............................................6
8.2 CHIMNEY FLUE ..............................................6
8.3 TECHNICAL FEATURES ..................................6
8.4 HEIGHT-DEPRESSION.....................................7
8.5 MAINTENANCE .............................................7
8.6 CHIMNEY POT ...............................................7
8.7 CHIMNEY COMPONENTS.............................8
8.8 EXTERNAL AIR INLET ......................................9
8.9 CHIMNEY FLUE CONNECTION.....................9
8.10
EXAMPLES OF CORRECT INSTALLATION ...
10
9 FUEL ...............................................................12
9.1 FUEL..............................................................12
10 INSTALLATION ...............................................13
10.1 INTRODUCTION..........................................13
10.2 OVERALL DIMENSIONS..............................14
10.3 GENERAL INSTALLATION ...........................15
10.4 ELECTRIC CONNECTION...........................15
11 USE ................................................................16
11.1 ATTENTION..................................................16
11.2 INTRODUCTION..........................................16
11.3 IGNITION.....................................................16
11.4 STOVE REFILLING........................................16
11.5 VENTILATION ..............................................17
11.6 ADVERSE WEATHER CONDITIONS ............17
11.7 CREOSOTE DANGER ................................17
11.8 FIRE EXTINGUISHING IN CASE OF FIRE......17
12 MAINTEINANCE ........................................17
12.1 INTRODUCTION..........................................17
12.2
BURNING POT AND ASH TRAY CLEANING ....
18
12.3 FUME PIPES ANNUAL CLEANING ............18
12.4 FANS CLEANING ......................................18
12.5 GENERAL CLEANING ...............................18
12.6 CLEANING OF PAINTED METAL PANELS 19
12.7 CLEANING OF CERAMIC PANELS ..........19
12.8 FAN REPLACEMENT .................................19
12.9 GASKET REPLACEMENT ...........................19
12.10 GLASS CLEANING ..................................19
12.11 HEART BREAK .........................................19
13 IN CASE OF ANOMALY ................................20
13.1 PROBLEM SOLVING ...................................20
14 TECHNICAL DATAS .......................................21
14.1 WIRING SCHEME........................................21
14.2 FEATURES ....................................................22

3
CARINA - DORA
EN
1 MANUAL SIMBOLOGY
• The icons with the stylized gures indicates whom the subject dealt in the paragraph is addressed to (between
the User and/or the Authorized Technician and/or the Specialized Stove-repairer).
• WARNING symbols indicates an important note.
USER
AUTHORISED TECHNICIAN
(ONLY to interpret or the Stove-manufacturer or the Authorized
Technician of Technical Assistance Service approved by the Stove-
manufacturer)
SPECIALIZED STOVE-REPAIRER
CAUTION:
READ CAREFULLY THE NOTE
CAUTION:
DANGER OR IRREVERSIBLE DAMAGE POSSIBILITY
2 DEAR CUSTOMER
• Our products are designed and manufactured in compliance with standards EN 13240 for wood stoves,
EN 14785 for pellet stoves, EN 13229 for re places, EN 12815 for wood cooker stoves, C.P.R. 305/2011 for
manufacturing products, Re n.1935/2004 for materials and objects which are in contact with foods, Dir.
2006/95/CEE for low tension, Dir.2004/108/EC for Electromagnetic compatibility.
• Read carefully the instruction contained in this manual to obtain the best efciency.
• This instruction manual is an integral part of the product: make sure it is delivered with the appliance also in
case of sold to others. In case of loss please ask a copy to your local Technical Assistance Service.
• All local regulations, including those referring to national European standards, must be respected during
appliance installation.
In Italy biomass system installation below 35 kW must comply with MD 37/08. Every qualied
installer who own these requirements, has to issue the certicate of conformity for the
installed system (“system” means: stove + chimney + air inlet).
• According to (EU) No. 305/2011 regulation, the “ Declaration of Performance” is available online at the web
sites www.cadelsrl.com / www.free-point.it.
3 CAUTIONS
• All the pictures carried in this manual are only for indicative and explanatory purpose and could therefore
slightly differ from your appliance.
• The referring appliance is those you purchased.
• In case of doubts or difculties in the comprehension or for problems not described in this manual, please
promptly contact your distributor or installer.
• It is forbidden to modify the appliance without authorization.

4CARINA - DORA
EN
4 WARRANTY CONDITIONS
The company guarantees the product, with the exception of elements subject to normal wear listed below, for
a period of 2 (two) years from the date of purchase attested by:
• a document to serve as proof of purchase (invoice and/or receipt) that shows the name of the vendor and
the date on which the purchase was made;
• forwarding of the completed certicate of guarantee within 8 days of purchase.
Furthermore, the product must be installed and started by specialised personnel who must, where provided,
issue a declaration of conformity of the plant and of the proper functioning of the product, for the warranty to
be valid and effective.
We recommend testing the product before completion with the relative nishes (claddings, painting of walls,
etc.).
Installations not meeting the current standards, improper use and lack of maintenance as expected by the
manufacturer, void the product warranty.
The guarantee is valid on the condition that the instructions and warnings contained in the use and maintenance
manual are observed, and therefore the product is used correctly.
The replacement of the entire system or the repair of one of its components does not extend the guarantee
period, and the original expiry date remains unchanged.
The guarantee covers the replacement or free repair of parts recognised as being faulty at source due to
manufacturing defects.
To benet from the guarantee, in the event of a fault, the customer must have the guarantee certicate and
present it with the proof of purchase document to the Technical Assistance Ofce.
The guarantee does not cover malfunctions and/or damage to the appliance that arise due to the following
causes:
• Damage caused during transportation or relocation.
• All parts that develop faults due to negligence or improper use, incorrect maintenance, installation that does
not comply with the manufacturer’s instructions (always refer to the installation and use manual provided
with the appliance).
• Incorrect dimensioning with regards to the use or faults in the installation or failure to adopt the necessary
devices to guarantee proper execution.
• Improper overheating of the equipment, use of fuels not conforming to the types and quantities indicated
in the instructions provided.
• Further damage caused by incorrect user interventions in an attempt to x the initial fault.
• Worsening of the damage due to the continued use of the equipment by the user, once the defect has
been noticed.
• In the presence of a boiler, any corrosions, incrustations or breaks caused by water ow, condensation,
hardness or acidity of the water, improperly performed descaling treatments, lack of water, mud or limescale
deposits.
• Inefciency of chimneys, ues or parts of the plant affecting the equipment.
• Damage caused by tampering with the appliance, atmospheric agents, natural disasters, vandalism,
electrical discharges, res, faults in the electric and/or hydraulic system.
Also excluded from this guarantee are:
• Parts subject to normal wear such as gaskets, glass, claddings and cast iron grids, painted, chrome-plated
or gilded parts, handles and electric cables, bulbs, indicator lights, knobs, all parts which can be removed
from the hearth.
• Variations in colour of the painted or ceramic/serpentine parts and craquelure ceramics as they are natural
characteristics of the material and product use.
• Masonry work.
• Plant parts (if present) not supplied by the manufacturer.
Any technical interventions on the product to eliminate the above-said defects and consequent damages must
be agreed upon with the Technical Assistance Centre, who reserves the right to accept the relative appointment
or not. However, said interventions will not be carried out under warranty but as technical assistance to be
granted at part of any eventual and specic agreed conditions and in accordance with the fee in force for the
work to be carried out.
The user will also be charged for any costs incurred to remedy the incorrect technical interventions, tampering
or damage to the appliance, not attributable to original faults.
Save for the legal or regulatory limits, the guarantee does not cover the containment of atmospheric and
acoustic pollution.
The company declines all liability for any damage which may be caused, directly or indirectly, to persons,
animals or objects as a consequence of non compliance with any prescription specied in the manual, especially
warnings regarding installation, use and maintenance of the appliance.

5
CARINA - DORA
EN
5 SPARE PARTS
For each repair or adjustment which should be necessary, please contact the dealer where you purchased your
stove or your nearest Technical Assistance Service, specifying:
• Appliance model
• Serial number
• Type of problem
Use only original spare parts which you can nd at our Technical Assistance Services.
6 WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT
The owner is the sole party responsible for demolishing and disposing of the product. This must be performed in
compliance with laws related to safety and environmental protection in force in his/her country.
At the end of its working life, the product must not be disposed of as urban waste.
It must be taken to a special differentiated waste collection centre set up by the local authorities or to a retailer
that provides this service.
Separating and recycling prevents potential negative effects on the environment and health (often caused by
inappropriately disposing of product parts). It also allows materials to be recovered in order to obtain signicant
savings in energy and resources.
7 PACKAGING AND HANDLING
7.1 PACKAGING
• The packaging is made up of recyclable cardboard boxes according to RESY standards, recyclable
expanded polystyrene inserts and wooden pallets.
• All packaging materials can be re-used for a similar use or eventually discharged as waste assimilable to the
municipal solid ones, in accordance with current regulations.
• After having removed the packaging please assure you about the integrity of the product.
Packaging are not toys and could cause suffocation or strangulation and other health
hazards! People (childreen included) with reduced mobility, psycological deseases or
without experience and knowledge must be kept away from packaging. The stove is not a
toy, please see ATTENTION page 16.
7.2 STOVE HANDLING
Both whether the stove is packed or not it is necessary to observe the following instructions for handling and
transporting the stove from its sale point to its installation point and for any future movements:
• The stove must be handled with idoneous means paying attention to the existing safety regulations;
• do not turn the stove upside down and/or upset it on one side, but keep it in vertical position or as accorded
with the constructor instructions;
• if the stove is made up of ceramic, stone, glass or any particularly fragile material components, all must be
moved with the utmost care.

6CARINA - DORA
EN
8 CHIMNEY FLUE
8.1 INTRODUCTION
This chapter about the Chimney Flue has been drawn up in cooperation with Assocosma (www.assocosma.org)
and is based on European Standards (EN 15287 - EN 13384 - EN 1856 - EN 1443 - UNI 10683:2012).
It provides instructions for a good and correct execution of the chimney ue but it does not absolutely replace
the current standards which the qualied manufacturer/installer should comply with.
Please check with your local authorities if exists any restrictive regulation which regards the
combustible air inlet, the fumes exhaust system, the chimney ue and the chimney pot.
The company declines any responsibility regarding the bad running of the stove if it is due to the use of a no
correctly dimensioned chimney ue which does not respect current regulations.
8.2 CHIMNEY FLUE
• The chimney ue or chimney is of great importance for the correct running of the heating appliance.
• It is fundamental that the chimney ue is perfectly built and always maintained with a perfect efciency.
• The chimney ue must be sole with insulated stainless-steel pipes or installed on the existing chimney ue.
• Both this solutions must be endowed with an inspection door.
8.3 TECHNICAL FEATURES
Fig. 1 - Inclined roof
LEGEND Fig. 2 page 6
1Height over the ridge of the roof = 0,5 mt
2Roof inclination ≥10°
390°
4Measured distance at 90° from the roof surface = 1,3 mt
• The chimney ue must be sealed from fumes.
• It must have a vertical run without narrowing. It must be realized with fume and condensation resistant
materials with thermal insulation and able to last against usual mechanical stresses.
It must be insulated to avoid condensation and to reduce fume cooling effects.
• The stove must be spaced out from fuels or ammable materials with an air gap or with insulating materials.
Check the distance with the chimney manufacturer.
• The chimney entrance must be placed in the same room where the appliance is installed or otherwise in

7
CARINA - DORA
EN
the adjacent room and it must be provided with a solid and condensation collection chamber under the
entrance, accessible through the sealed metal gate.
• The inner section of the chimney ue can be round (the best one) or square and the jointed sides must have
a minimum radius of 20 mm.
• The section dimension must be minimum Ø150 mm and maximum Ø240 mm.
• Made the efciency of the chimney ue overhauled by an expert stove-repairer and if necessary cover the
chimney ue with materials in compliance with current regulations.
• The ue system must be placed on the roof.
• The chimney ue must be provided CE in accordance with EN 1443 regulation. Please nd attached an
example of label:
Fig. 2 - Example of label
8.4 HEIGHT-DEPRESSION
The depression (draught) of a chimney ue depends also on its height. Check the depression with the values
provided at . Minimum height 3,5 meters.
8.5 MAINTENANCE
• The chimney ue must be cleaned, since the soot and unburnt oil deposits reduce its section so blocking the
draught. In great quantities they can are up.
• The fumes extraction pipes (fumes conduit + chimney ue + chimney pot) must always be cleaned, scrubbed
and checked by an expert stove-repairer, in compliance with current regulations, with the instructions of the
stove-manufacturer and the directives of your insurance company.
• In case of doubts, please follow the most restrictive regulations.
• Have your chimney ue and chimney pot checked and cleaned by an expert chimney sweep at least once
a week. The chimney sweep has to release a written declaration about the security of the system.
• Not cleaning compromise safety.
8.6 CHIMNEY POT
Fig. 3 - Anti-wind chimney pots
The chimney pot is important for the correct running of the heating appliance:
• We recommend using an anti-wind chimney pot, see Fig. 4 page 7.
• The hole width for fumes exhaust must be the double of the chimney ue width and tted in a way that the
fume exhaust is assured also in case of wind.
• It should prevent the inltration of rain, snow and animals.
• The outlet height in the atmosphere must be away from the reux area caused by the roof structure or by

8CARINA - DORA
EN
obstacles laying nearby (see TECHNICAL FEATURES page 6).
8.7 CHIMNEY COMPONENTS
Fig. 4 - Chimney components
LEGEND Fig. 5 page 8
1Chimney pot
2Fume outlet
3Chimney ue
4Termal insulation
5External wall
6Chimney union
7Fume pipe
8Heat generator
9Inspection door
10 Damper

9
CARINA - DORA
EN
8.8 EXTERNAL AIR INLET
Fig. 5 - Direct air inow Fig. 6 - Indirect air inow
LEGEND Fig. 6 page 9-Fig. 7 page 9
1Room to ventilate
2Adjacent room
3External air inlet
4Cleft under the door
• The room must be endowed with an external air recycling for a good climate in your ambient.
• The air inow from outside to the inner occurs directly, through an opening on the external wall of the room
(see Fig. 6 page 9); otherwise it occurs indirectly by air suction from rooms adjacent to the one to ventilate
(see Fig. 7 page 9).
• Bedrooms, garages, and store of ammable materials are excluded.
• The air inlet should have a total net surface of 100 sqcm2: the aforesaid surface is to widen if inside the room
there are other activated appliances (for example: electric ventilators for foul air suction, cooker hoods, other
stoves, etc...) which depress the environment.
• At switched on appliance it is necessary to check that the pressure fall between the room and the outside
does not exceed 4,0 Pa value: if necessary widen the air inlet (EN 13384).
• The air inlet must be realized at a height close to the oor with an external grid against birds. In such a way it
cannot be obstructed by any object.
• In case of installation with sealed-chamber the air inlet is not necessary.
8.9 CHIMNEY FLUE CONNECTION
Your stove works through a natural draught. It is obligatory to check that all pipes are realized in compliance
with the following regulation on material selection: EN 1856-1, EN 1856-2 e UNI/TS 11278. All must be effected by
specialized personnel or companies as provided by UNI 10683:2012.
• The connection between the appliance and the chimney ue should be short in order to favor the draught
and to avoid condensation in the pipes.
• The fume conduit should be equivalent or longer than the outlet joint ones.
• Some stove models are endowed with a lateral and/or back exhaust. Check that the unused exhaust is
sealed with the plug given with standard equipment.
SYSTEM TYPE Ø150 mm PIPE Ø240 mm PIPE
Minimum vertical length 1,5 mt 2 mt
Maximum length (with 1 union) 6,5 mt 10 mt
Maximum length (with 3 unions) 4,5 mt 8 mt
Maximum number of unions 3 3
Level section (minimum inclination 3%) 2 mt 2 mt
Installation at a height above 1200 m a.s.l. NO Obligatory
• Use a specic plate pipe for stoves.
• It is forbidden to use metal, bre cement or aluminium exible pipes.
• For change of direction it is obligatory always to use a T-union (or a curve not with right angle) with inspection

10 CARINA - DORA
EN
plug which enables an easy periodic cleaning of the pipes.
• Please assure you that after the cleaning the inspection plugs are sealed with its efcient gasket.
• It is forbidden to connect more appliances to the same fume conduit.
• It is forbidden to convey in the same fume conduit exhausts from overhanging cooker hoods.
• It is forbidden to exhaust ue gases directly from the wall towards the outside and closed spaces also at open
top.
• It is forbidden to connect any other appliance (wood stoves, cooker hoods, boilers, etc...).
• The fume conduit must be placed at a distance of minimum 500 mm from ammable or heat-susceptible
components.
• The fume conduit must be connected with stove exhaust in a xed and tight manner, and if required with the
insertion of a damper.
8.10 EXAMPLES OF CORRECT INSTALLATION
Fig. 7 - Example 1
LEGEND Fig. 8 page 10
1Insulating material
2Reduction from Ø150 to Ø120 mm
3Inspection plug
4Minimum safety distance = 0,5 mt
5Damper
• Chimney ue installation Ø150 mm with an enlarged drilling for pipe transit.

11
CARINA - DORA
EN
Fig. 8 - Example 2
LEGEND Fig. 9 page 11
1Insulating material
2Inspection plug
3Chimney inspection entrance
4Minimum safety distance = 0,5 mt
5Inclination ≥ 3°
6Level section ≤ 1 mt
7Damper
• Old chimney ue with an inserted pipe of minimum Ø150 mm and with an external door which enables the
chimney cleaning.
Fig. 9 - Example 3
LEGEND Fig. 10 page 11
1Insulating material
2Inspection plug
3Minimum safety distance = 0,5 mt
4Damper

12 CARINA - DORA
EN
• External chimney ue entirely made up of insulated stainless steel pipes, i.e. with double wall of minimum Ø150
mm: all must be rmly attached to the wall. For chimney against wind effects please (see Fig. 4 page 7).
• Ducting system through T-unions which enables an easy cleaning without disassembling the pipes.
We recommend to check with your chimney ue manufacturer the safety distances which
must be respected and the type of insulating material. The aforesaid regulations are valid
also for holes made on the wall (EN 13501 - EN 13063 - EN 1856 - EN 1806 - EN 15827).
9 FUEL
9.1 FUEL
• The allowed fuel is rewood and its derivatives (lignite blocks, compressed sawdust, etc.) with a maximum
water content of 20%.
• To obtain good rewood, it must be seasoned outside for at least 2 years in a place protected from the
weather.
• Using humid wood or waste bark could create condension and creosote into the ductions and in the hearth.
A heat yield of humid wood is great lower than dry wood.
Fig. 10 - Wood positioning
To know the lenght of wood log to use, check the dimensions of stove combustion chamber.
It is advisable to place the wood in horizontal position (see Fig. 11 page 12) and adjust the air ow with the aid
of the register.
To ignite proper ignitier products can be used.
It is forbidden to use any type of liquid combustible!
It is forbidden to burn wood processing waste containing glue or paint, waste in general
and cardboard!

13
CARINA - DORA
EN
• Here following some information about the quality of different type of woods:
TYPE OF WOOD QUALITY % PERFORMANCE
Oak Excellent 100
Hornbeam Excellent 100
Ash Very good 92
Maple Very good 91
Birch Good 89
Elm Good 84
Beech Good 80
Willow Sufcient 71
Spruce Sufcient 70
Red deal Fair 67
Larch Fair 66
Lime Worst 57
Poplar Worst 50
10 INSTALLATION
10.1 INTRODUCTION
• The assembly position dipends on on environment, exhaust, chimney ue.
• Check with local authorities if there are any restrictive regulations which regard the combustible air inlet,
room ventilation, fume exhaust system together with chimney ue and chimney pot.
• The manufacturer declines any responsibility in case of installation which are not in compliance with current
regulations, in case of a wrong room ventilation system, in case of an electric connection which is not in
compliance with regulations and in case of a wrong use of the appliance.
• Intallation, electric connection, operation test and maintenance must be carried out by an authorized and
skilled technician.
• Check if there is the combustible air inlet.
• Check the probable presence of other stoves or appliances which could depress the room (see EXTERNAL
AIR INLET page 9).
• Check at switched on stove if there is the presence of CO in the room.
• Check if the chimney has the necessary draught.
• Check if during the fume passage all has been executed in safety (probable fume losses and distances from
ammable materials, etc.…).
• The installation of the appliance must enable an easy access for appliance, fume exhaust pipes and chimney
ue cleaning.
• The installation must enable en easy access to the electric connection plug (see ELECTRIC CONNECTION
page 15).
• It is forbidden to install the stove in bedrooms, bathrooms and in rooms used for storing combustible materials
and in one-room ats.
• In any case the stove must not be installed in rooms where it can get in touch with water or water splashes
because this can cause burn hazards and short-circuit.
• To install more appliances, the external air inlet must be correctly dimensioned (see EXTERNAL AIR INLET page 9).
• Only in room used as kitchen is possible to use appliances for cooking with its hood without steam extractor.
• Only type “C” appliances are allowed and not type “B”: make reference to regulations active in the country
where the appliance is installed.

14 CARINA - DORA
EN
10.2 OVERALL DIMENSIONS
Fig. 11 - Overall dimensions
LEGEND Fig. 12 page 14
152 cm
292,5 cm
345,8 cm
414 cm
526 cm
6Exhaust fumes d.12 cm

15
CARINA - DORA
EN
10.3 GENERAL INSTALLATION
Fig. 12 - General installation
LEGEND Fig. 13 page 15
1Stove
2Minimum lateral distance = 300 mm
3Minimum rear distance = 300 mm
4Minimum front distance = 1000 mm
• Please check that the oor has an adequate load capacity. If the existing one does not satisfy this requirement,
appropriate measure should be provided (for example a plate for distributing the load).
• It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air ow of 300
mm on the sides and 300 mm on the back, to enable an ecient appliance cooling and a good distribution
of heat in the room (see Fig. 13 page 15).
• For safety re regulations the distances from ammable or sensible to heat objects (sofas, pieces of furniture,
wooden covering, etc...) must be respected, has described in Fig. 13 page 15.
• If there are highly ammable objects (curtains, tted carpet, etc...), all these distances must be further
increased with 1 meter.
• If the walls are made up of ammable materials, check the safety distances (see Fig. 13 page 15).
• At maximum power check that the wall temperature does not ever exceed 80°C. If it would be necessary
please install a re resistant plate on the concerned walls.
• In some countries also masonring load-bearing walls are considered ammable.
10.4 ELECTRIC CONNECTION
Some wood stove models are endowed with a forced ventilation system, so they need an electric connection.
Warning: the appliance must be installed by an authorized technician!
• The electric connection occurs through a cable with plug put in an electric socket which is able to support
charge and tension specic of every model, as described in the technical datas table (see FEATURES page
22).
• The plug must be easily accessible when the appliance is installed.
The cable must not get in touch with the fume exhaust pipe and nor with every other part
of the stove.

16 CARINA - DORA
EN
• Please further assure you that your network is endowed with an efcient earth connection: if it does not exist
or if it is not efcient, please endow you with one in compliance with the law.
• Do not use extension cables.
• If the feeder cable is damaged, it must be replaced by an authorized technician.
• When the stove is not going to be used for a long period of time, it advisable to remove the plug from the
socket on the wall.
11 USE
11.1 ATTENTION
This appliance must not be used by people (childreen included) with reduced mobility,
psycological deseases or without experience and knowledge except in case of supervision
or instruction about the use of the appliance by people responsible for their safety.
Childreen must be constantly overseen in order to assure that they do not play with the
appliance.
During its running, the stove reaches high temperatures: keep away childreen and animals
and for your safety please use appropriate reproof devices, such as heat-protecting gloves.
11.2 INTRODUCTION
To have the best performance with the lowest consumption please follow the here descripted instructions.
• Wood ignition occurs very easily if the installation is correct and if the chimney ue is efcient.
• By rst ignition of the stove hold a slow re for at least 4-5 hours in order to allow the material of which
the heater and the hearth are made up of to adjust the inner mechanical stresses. This operation must be
executed at least 3-4 times a year.
• Plant fat waste and varnishes can release bad smells and smoke during rst working hours: it is advisable to
ventilate the room because they can be noxious to people and animals.
Do not use ammable liquids during the ignition (alcool, petrol, oil, etc...).
11.3 IGNITION
• If inside the combustion chamber there are booklets, manuals, etc..., remove them.
• Check if the plug is correctly inserted in the electric socket (only for stoves with forced ventilation).
• Completely open the primary air inlet register and the damper.
• Put the re-starter bars and seasoned wood logs into the burning pot.
• Ignite the bars and right after insert well seasoned wood logs and close the oven door.
For a better yield, as soon as there is a live ame, iti is advisable to close the primary air valve to the minimum
and keep the damper at 45° in order to have the maximum performance (nominal output) with the lowest fuel
consumption.
11.4 STOVE REFILLING
During stove relling do not wear ammable or large clothing.

17
CARINA - DORA
EN
Do not open and close the re door violently: the glass can brake!
Open the re door with naked ames can be dangerous for user and/or home.
During operation some external parts can reach high temperatures. During relling fases use
proper protection gloves given as equipment.
• It is advisable to rell the stove only when on the rebox are only embers.
• Please proceed as follows: close the primary air valve, open the re door slowly, shake the ash with the
appropriate instrument, insert wood in the hearth, close the door and adjust again the primary air valve.
During regular working is dangerous to keep open the ash drawer and/or the re box to
increase air draught! There are appropriate instruments to adjust combustion air (primary air
valve, register, etc...).
11.5 VENTILATION
Some models are endowed with a forced ventilation system with a manual reset: turn it on and off through the switch.
The air blowed by fans keeps the stove at a lower temperature thus avoiding excessive stresses to materials of
which the stove is made up and at the same time heats the environment homogeneously.
Make periodically sure about the effective operation on the fan.
In case of black out or if the ventilation is out of order, the stove can work in the same way
provided that using a low ame.Thus do not load the hearth with wood excessively. In case
that the fan is out of order, contact an authorized technician who will replace it woth an
original spare part.
11.6 ADVERSE WEATHER CONDITIONS
When the external temperatures are severe and/or there are adverse weather conditions (strong wind), the
chimney is subjected to a lack in draught thus impeding a correct fume expulsion.
• Fill the heart with few wood logs and keep air register valves opened completely.
11.7 CREOSOTE DANGER
The use of humid and/or bad quality wood (for example resinous wood) cause creation of creosote along the
chimney ue obstructing fume passages. The creosote is ammable and if amassed over the time it must be
removed in order to prevent the risk of re of the chimney ue.
• In case of re close air register valves and contact immediately the remen.
• When the chimney has stopped burning, have the chimney ue checked by an expert stove-repairer.
11.8 FIRE EXTINGUISHING IN CASE OF FIRE
In case it would be necessary to extinguish the re emitted by the stove or by the chimney ue, use a re-
extinguisher or contact the remen. DO NOT use water to extinguish the re inside the burning pot.
12 MAINTEINANCE
12.1 INTRODUCTION
For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.

18 CARINA - DORA
EN
• Fume outlet pipes (fume conduit + chimney ue + chimney pot) must always be cleaned, scrubbed and
checked by an authorized technician in compliance with local regulations, with the instructions of the
manufacturer and those of your insurance company.
• If there are no local regulations and no instruction from your insurance company, it is necessary to have your
fume pipe, chimney ue and chimney pot cleaned at least once a year.
• It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and
the electronical elements (if there are) checked at least once a year.
All these operations must be planned in time with your Autorized Technical Assistance
Service.
• After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust.
• If the stove had been using continuously and intensely, the whole system (chimney included), must be
cleaned and checked more frequently.
• In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer.
Before any movement let the re inside the combustion chamber extinguish till the total
cooling and always disconnect the plug from the socket (if there are).
12.2 BURNING POT AND ASH TRAY CLEANING
For a good combustion, before of every stove ignition, remove the ash which has settled in the burning pot. The
abundant ash obstructes the primary air ow which is fundamental for a good combustion.
• Remove ash from the burning pot by shaking it to let it fall in the ash tray.
• If full, the sah tray must be empty.
• Ash must be kept in a metal container with sealed cap, the same container must not ever be in contact with
ammable materials (for example lent over a wooden oor), as ash inside keeps embers glowing for a long time.
• Only when the ash is completely extinguished can be throuwn in the organic waste.
• Clean the ash also in the ash compartment.
12.3 FUME PIPES ANNUAL CLEANING
Clean once a year from soot with brushes.
The cleaning operation must be executed by a specialized stove-repairer who will provide for the cleaning of
fume pipe, chimney ue and chimney pot. He will also check their eciency and will release a written declaration
of the safety of the appliance. This operation must be executed at least once a year.
12.4 FANS CLEANING
For models with ventilation, clean every year the room fan from ash or dust which can cause a blade unbalance
and a greater noise.
As this operation is so delicate it must therefore be executed by an Authorized Technician.
12.5 GENERAL CLEANING
For cleaning external and inner parts of the stove do not use steel wools, muriatic acid or other corrosive and
abrasive materials.

19
CARINA - DORA
EN
12.6 CLEANING OF PAINTED METAL PANELS
To clean painted metal panels use a soft cloth. Do not use degreasant agents like alcool, diluents, acetone,
gasoline because these could irremediably damage the varnish.
12.7 CLEANING OF CERAMIC PANELS
Some stove models has an external lining made up of ceramic. These pieces are handmade therefore they
could inevitably present crazings, seedinesses, shadings.
To clean ceramic panels use a soft and dry cloth. If using any cleaners this will seep through the crazings putting
them in evidence.
12.8 FAN REPLACEMENT
For fan replacement proceed as follows:
• Extract the plug from the socket.
• Remove the ceramics to prevent breakage.
• Disconnect the chimney, tilt the stove and place it on the oor on the back side.
• Unscrew the 4 screws at the sides of the casing of the fan.
• Disconnect the faston and unscrew the failure fan screws.
• Replace the fan and repeat the inverse operation.
12.9 GASKET REPLACEMENT
In case of deterioration of re door gasket and/or ash door gasket it is necessary to replace them by an autorized
technician in order to guarantee the good running of the stove.
Use exclusively original spare parts.
12.10 GLASS CLEANING
The glass-ceramic of the re door is able to stand till 700°C but not to thermal shocks.
The probable cleaning with usual sale product for glass cleaning must be effected at cool glass in order to avoid
explosions.
12.11 HEART BREAK
Probable cast iron or refractory heart break are due to an excessive overheating caused by too much fuel or
by too much combustion air. Have the damaged elements immediately replaced in order to avoid feather
damages to the stove.
Use exclusively original spare parts.

20 CARINA - DORA
EN
13 IN CASE OF ANOMALY
13.1 PROBLEM SOLVING
In case of doubts regarding the use of the stove, please contact ALWAYS the Authorized
Technician on order to avoi irreparable damages!
PROBLEM CAUSE SOLUTION INTERVENTION
Ignition difculties
Too large wood Use small and well dried wood logs during ignition, before
bigger wood logs.
Too humid wood Use well seasoned wood.
Lack of chimney
draught
Open the registers completely. (If the problem persists,
contact and expert stove repairer who will check the
chimney ue efciency).
Ambient without
air recycling Create immediately a ventilation grid.
Creation of
condensation
Large chimney
ue section
Reduce the chimney ue section with thermal insulater
pipes.
No insulated
chimney ue Cover the chimney ue with insluating material.
Too slow
combustion
Open air registers in order to increase the re and fume
output temperature.
Fume leakage
from the heart
No insulated
chimney ue Cover the chimney ue with insulating material.
Adverse wheather
conditions No windproof chimney pot: have it replaced.
Too humid wood Use well seasoned wood.
This manual suits for next models
1
Table of contents
Other Cadel Wood Stove manuals
Popular Wood Stove manuals by other brands

RAIS
RAIS attika NEXO 100 GAS installation guide

WoodPro
WoodPro WS-TS-1500 owner's manual

Contura
Contura C 586W installation instructions

Palazzetti
Palazzetti EVA GENERAL INFORMATION - WARNINGS - INSTALLATION - MAINTENANCE

Lopi
Lopi 1250 Republic owner's manual

Panadero
Panadero CAPRI 3V Usage and maintenance instructions