Caho DTS961 User manual

CAH0
DIGITAL CONTROLLER WITH TIMER+STEAM INSTRUCTION MANUAL
ON / OFF
SR-D961
*
*
No、hi、lo、dFh、dFl
No、hi、lo、dFh、dFl
A2Y
A1Y
A2F
A1F
Td2
Td1
Act
f
Il
LOL
TYP
ON
SPO
PVO
Hys
Ct
P
A1
A2
CH
CL
VER
LOL~HIL
LOL~HIL
0~100
0~50%FS
-99~50%FS
0~100
1、2、3
K . J
0~SV
0~100
H/C
0、5、10、30
0~100
0~500
0~500
0~A2
0~A1
℃
℃
℃
℃
℃
℃
℃
℃
℃
%
type
CT=0
H:C:
10
20
0
2
0
0
1
K
0
400
2
H
0
0
NO
1
1
470
90
HL
I
A1F
A2F
PANEL DESCRIPTION
UP / DOWN KEY
OUTPUT
INDICATOR
ON / OFF BUTTON KEY: Power on/off button key. It is also used to
enter each parameter level for setting.
UP KEY: Is used to increment set value.
Whether the power had directly applied or by pressing the ON/OFF power button, the
screen will display the set temperature value (flashing) first, then to be followed by the
current temperature value.
Regardless of what parameter level you are in, if left idle within 5 secs, the display
will automatically return to its original operation mode.
PARAMETER DESCRIPTION LIST AND SETTING:
CODE DESCRIPTION SETTING RANGE UNIT DEFAULT
VALUE REMARKS
LEVEL 1
LEVEL 2
LEVEL 3
ALARM1 SET VALUE
ALARM2 SET VALUE
IF SET NO, NO DISPLAY
IF SET NO, NO DISPLAY
PROPORTIONAL BAND
BECOMES ON/OFF CONTROL
IF P=0
CYCLE TIME
PARAMETER NOT AVAILABLE IF P=0
AVAILABLE IF P=0
HYSTERESIS
PV OFFSET
SV OFFSET
ON/OFF SETTING MODE
REFER TO NOTE (1) -
ON/OFF MODE SETTING DESC.
INPUT SELECTION TYPE
LOWEST TEMP. SETTING LIMIT
HIGHEST TEMP. SETTING LIMIT
FILTER SETTING
CONTROL ACTION SETTING HEATING COOLING
SV LOOP DISPLAY SETTING
ALARM DELAY TIME SETTING
SEC.
SEC.
ALARM1 MODE SETTING
ALARM2 MODE SETTING
REFER TO NOTE (3) -
ALARM OUTPUT TYPES
REFER TO NOTE (3) -
ALARM OUTPUT TYPES
ALARM1 HYSTERESIS SETTING
SEC.
ALARM2 HYSTERESIS SETTING
4-20mA OUTPUT HIGHEST SETTING
4-20mA OUTPUT LOWEST SETTING
VERSION
(PRESS AND HOLD ON/OFF BUTTON FOR 5 SECS)
ONLY APPEARS WHEN
CT=0
ONLY APPEARS WHEN
2017 NO. 1
RELAY = 10 SEC
SSR = 2 SEC
SCR = 0 SEC
SV~400
、4
、5
TON
TIME-ON SELECTION
TeD
TIME-END SELECTION
、OFF
A. FOR TEMPERATURE CONTROL PARAMETER
TEMPERATURE
KEY SETTING
TIMER KEY
SETTING DOWN KEY: Is used to decrement set value.
“OFF”
NOTE (1): ON/OFF MODE SETTING DESCRIPTION:
CODE MODE DESCRIPTION
SCREEN DISPLAY
“OFF”
ALL OFF
NO DISPLAY
OUTPUT STOP, ALARM OFF
OUTPUT STOP, ALARM ON
OUTPUT STOP, ALARM OFF
4
5
POWER ON:
OUTPUT STOP, ALARM OFF
SCREEN DISPLAYS
“OFF” WHEN
POWER ON
POWER ON:
OUTPUT STOP, ALARM OFF
DECIMAL POINT
LIT ON
NOTE (3): ALARM OUTPUT TYPES ILLUSTRATION:
(A1F AS EXAMPLE)
DFL
DFH
lo
hi
No
CODE DESCRIPTION TYPE ILLUSTRATION
NO ALARM NONE
ABSOLUTE VALUE
UPPER LIMIT
ABSOLUTE VALUE
LOWER LIMIT
DEVIATION
UPPER LIMIT
DEVIATION
LOWER LIMIT
A1
A1 ON
SV
A1
A1 ON
SV
A1 ON
A1
It refers to the difference between the display temperature
value and the setpoint value.
TON
NOTE (2): Setting the value range for
For instance:
SV = 100
TON = 1
It indicates that once the temperature reaches 99 degrees
celcius, the controller timer will start automatically.
OFF BUTTON KEY: Is used to stop/halt output. Screen display “OFF”,
flashing together with the current temperature value alternately.
ON BUTTON KEY: Output ON. Display SV temperature (flashing)
first, then in a few seconds it will display the current temperature after.
IF = on, OUTPUT
TURNS OFF AUTOMATICALLY.
- 1 -
TeD
NO
REFER TO NOTE (2) -
SETTING TON VALUE
B. EXPLANATORY NOTE:
LED ON: OUTPUT ON
LED OFF: OUTPUT OFF
(PRESS AND HOLD ON/OFF BUTTON FOR 5 SECS TO ENTER EACH PARAMETER LEVEL)
、60
1~300
(PRESS AND HOLD ON/OFF BUTTON FOR 5 SECS)
DB
-
-50~50 0SETTING NOT AVAILABLE
、on OFF
-99~50%FS
OFF
OFF

℃
1 0
ON
OFF
CAHO
Timer
ON
DTS961
Digital Temperature Controller with Timer
Steam
TIMER
BUTTON KEY
Use to run and stop
timer after setting.
STEAM
BUTTON KEY
Use to activate and
deactivate steam.
A1 ON
A1
C. FOR TIMER PARAMETER
SW1
REL
UNI
HH.M
CODE DESCRIPTION SETTING RANGE UNIT DEFAULT
VALUE REMARKS
LEVEL 1
UNIT OF MEASUREMENT
RELAY OUTPUT
-
、
MMM
、
SSS
H
M
s
: Hour
: Min
: Sec
10 MINUTES
A. B
MMM
A
OUT OFF
-
-
OFF
-
SEC
0
SW2
STEAM FUNCTION SEC
3
(PRESS AND HOLD RUN/STOP BUTTON FOR 5 SECS TO ENTER EACH PARAMETER LEVEL)
SPECIAL CHARACTER GUIDE
DIMENSION
PANEL CUT-OUT 91*91mm
DTS961
A B C D Eabcd
96 96 12 92 90 91 91 120 110
+0.5
0
+0.5
0
MODEL
(Unit: mm)
T1
RL1
RL2
WIRING DIAGRAM
A
B
ON
OFF
CAHO
ON
DTS961
Digital Temperature Controller with Timer


C D
E
c
b
ad
ORDERING CODE
計時+蒸氣 TS
Timer + Steam
附加功能
Option
DTS 961
0~100
0~200
0~300
0~400
C
D
R
E
2
A1
A1& A2
1
0
0~999
- 2 -
SETTING NOT AVAILABLE
SETTING NOT AVAILABLE
OUTPUT CONTACT RL2
1. Relay output - suitable for ON/OFF or P control mode.
2. S.S.R. output - suitable for ON/OFF or P control mode.
3. 4-20mAoutput - suitable for P control mode only.
4. Alarm output : Absolute (upper/lower) limit , deviation (upper/lower) limit.
Note:
OUTPUT CONTACT T1

Popular Controllers manuals by other brands

Omron SmartVision MX user guide

Omron

Omron SmartVision MX user guide

Hitecsa pGD user manual

Hitecsa

Hitecsa pGD user manual

dbx ZC-9 How to use

dbx

dbx ZC-9 How to use

Samson TROVIS 5500 Mounting and operating instructions

Samson

Samson TROVIS 5500 Mounting and operating instructions

Bürkert 8691 operating instructions

Bürkert

Bürkert 8691 operating instructions

National Instruments PCI-7352 Getting started

National Instruments

National Instruments PCI-7352 Getting started

Niobrara QUCM Installation and programming manual

Niobrara

Niobrara QUCM Installation and programming manual

Bestway 62102 instructions

Bestway

Bestway 62102 instructions

Otai Fusion 256 user manual

Otai

Otai Fusion 256 user manual

Zeva EVMS Lite quick start guide

Zeva

Zeva EVMS Lite quick start guide

Danfoss OPTYMA Plus OP-LPQM manual

Danfoss

Danfoss OPTYMA Plus OP-LPQM manual

AC STAG 400 installation manual

AC

AC STAG 400 installation manual

BobsCNC KL7 Series Assembly manual

BobsCNC

BobsCNC KL7 Series Assembly manual

TimeTec Security BLE-16 installation guide

TimeTec Security

TimeTec Security BLE-16 installation guide

Cressi T10 S.C. Directions for use

Cressi

Cressi T10 S.C. Directions for use

Mitsubishi Electric Melservo MR-J3-10B instruction manual

Mitsubishi Electric

Mitsubishi Electric Melservo MR-J3-10B instruction manual

SpeedyBee F405 V4 BLS 55A 30x30 Stack user manual

SpeedyBee

SpeedyBee F405 V4 BLS 55A 30x30 Stack user manual

Centork 482 Series Installation and Maintenance user Manual

Centork

Centork 482 Series Installation and Maintenance user Manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.