Calix E7-2 User manual

Calix E7-2 Installation Guide
May 2013
#220-00320, Rev. 13


Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
Contents
About This Guide......................................................................5
Chapter 1: Calix E7-2 Product Overview ...............................7
Introducing the Calix E7-2 ........................................................................................8
Product Dimensions................................................................................................10
Chapter 2: Installation Considerations................................11
Installation Guidelines ............................................................................................12
Safety Recommendations and Notices..................................................................13
Required Items.........................................................................................................14
Preparations Before You Begin..............................................................................16
Chapter 3: Installing the Calix E7-2......................................17
Installing the E7-2 Chassis.....................................................................................18
Grounding the Chassis...........................................................................................21
Connecting DC Power.............................................................................................23
Installing the Fan Module........................................................................................24
Installing E7-2 Line Cards.......................................................................................26
Installing a Fiber Guide...........................................................................................28
Installing an Intake/Exhaust System......................................................................31

4
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
Chapter 4: Wiring the E7-2 Network Interfaces...................33
Connecting the E7-2 Management Interfaces.......................................................34
Connecting to the Ethernet Management Ports..............................................34
Connecting to the RS-232 Serial Port.............................................................36
Wiring the External Alarm and Timing Interfaces.................................................37
Wiring External Alarms ...................................................................................37
Wiring the BITS Timing Interface....................................................................39
Connecting the E7-2 Line Interfaces......................................................................41
Installing Pluggable Transceiver Modules.......................................................42
Connecting Fibers...........................................................................................43
Connecting to the Copper Access Interfaces..................................................44
Chapter 5: Maintenance ........................................................47
Replacing Pluggable Transceiver Modules...........................................................48
Replacing an E7-2 Line Card..................................................................................49
Replacing the Fan Module......................................................................................50
Fan Filter Maintenance............................................................................................51
Chapter 6: Reference Information........................................53
E7-2 Specifications..................................................................................................54
E7-2 LED Behavior ..................................................................................................55
RS-232 Serial Port Pins...........................................................................................57
RJ-21 Pin Assignments...........................................................................................58
Fiber Handling Techniques.....................................................................................60

5
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
About This Guide
This document provides a general installation practice for the Calix E7-2 Ethernet service
access platform. This document includes guidance for planning, power installation, cabling,
and maintenance.
Intended Audience
This document is intended for use by network planning engineers, outside plant engineers,
CO technicians, and field support personnel, as well as craft personnel responsible for
equipment installation, cabling, and maintenance. Familiarity with standard telecom and
datacom terminology and practices, as well as standards-based Ethernet technologies and
conventions, is recommended.
Related Documentation
You can access all Calix product documentation, including Calix E7-2 configuration
practices, from the Calix Resource Center online at www.calix.com
(https://www.calix.com/portal/site/resourcecenter/).
Safety Notices
This document uses the following safety notice conventions.
DANGER! Danger indicates the presence of a hazard that will cause
severe personal injury or death if not avoided.
WARNING! Warning indicates the presence of a hazard that can cause
severe personal injury if not avoided.
CAUTION! Caution indicates the presence of a hazard that can cause
minor to moderate personal injury if not avoided.
ALERT! Alert indicates the presence of a hazard that can cause damage to
equipment or software, loss of data, or service interruption if not avoided.

6
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
DANGER! CLASS 1 LASER PRODUCT. INVISIBLE LASER RADIATION
MAY BE PRESENT. Fiber optic radiation can cause severe eye damage or
blindness. Do not look into the open end of an optical fiber.
CE Marking Conformity
The Calix E7-2 product complies with the Council of European Communities
Directive 93/68/EEC. A copy of the CE marking EC Declaration of
Conformity for the Calix E7-2 is available upon request. Contact your Calix
Sales Engineer for more information.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
Chapter 1
Calix E7-2 Product Overview
This chapter introduces the Calix E7-2 Ethernet service access platform and provides a
general overview of the E7-2 small form factor chassis and components.
Topics Covered
This chapter covers the following topics:
Introducing the Calix E7-2
Product dimensions

8
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
Introducing the Calix E7-2
The Calix E7-2 Ethernet service access platform is a compact IP services networking system
that provides high performance Ethernet-based transport, aggregation, and FTTP services
delivery from an environmentally hardened, small form factor chassis.
Calix E7-2 system
The Calix E7-2 delivers a wide array of high performance applications, including 10GE
Ethernet transport, high-density residential triple play services over GPON and point-to-
point Ethernet, Metro Ethernet Forum (MEF) compliant business services, mobile backhaul,
and protected GE aggregation.
Calix E7-2 shelf views
The Calix E7-2 system consists of the 2-slot E7-2 chassis, a removable fan module, and up to
two high capacity line cards in universal card slots.
Calix E7-2 (front)
The Calix E7-2 line cards and fan module install into the front of the E7-2 shelf. When
equipped with line cards, the E7-2 front panel also terminates system line interfaces (fibers).
The E7-2 fan module is equipped with Craft Ethernet and serial ports for management and
features several system status indicators.
Calix E7-2 (rear)

9
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
The E7-2 power inputs (A/B), ground, alarm I/O, Craft management, and BITS timing
interfaces are located on the rear of the E7-2 shelf. The E7-2 rear panel also has four RJ-21
copper interface connectors.
Calix E7-2 cards
The Calix E7-2 is equipped with two universal line card slots, supporting a flexible array of
high capacity line cards, including:
Fiber access service line cards: Calix E7-2 fiber cards provide optical ports for front
access termination.
Copper access service line cards: Calix E7-2 copper cards (e.g., VDSL2) terminate on
the E7-2 rear panel.
All E7-2 line cards use pluggable transceiver modules for optical and copper-based interfaces,
including industry standard SFP, SFP+ and XFP modules. Each port on each card has an
LED to indicate an established link and data traffic activity. For detailed information on the
E7-2 line cards, see the Calix E7 User Guide.
An E7 'blank' card (equipped with no electronics) ships with every E7-2 shelf. The blank
card plugs into either of the two universal slots and is used to maintain emissions and
facilitate proper airflow in E7-2 systems with only one line card. Whenever an E7-2 shelf
operates with only one line card, a blank card must be installed in the other slot.

10
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
Product Dimensions
E7-2 chassis dimensions
The Calix E7-2 chassis exterior dimensions follow:
Height: 1.7 inches (4.3 cm)
Width: 17.5 inches (44.5 cm)
Depth: 11.45 inches (29.1 cm)
E7-2 fan module dimensions
The Calix E7-2 fan module exterior dimensions follow:
Height: 1.63 inches (4.1 cm)
Width: 2.67 inches (6.8 cm)
Depth: 10.82 inches (27.5 cm)

Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
Chapter 2
Installation Considerations
This section discusses general installation considerations and guidelines. Review this
information before starting the installation process.
Topics Covered
This section covers the following topics:
Installation guidelines
Safety recommendations and notices
Items required for installation (tools and materials)
Preparations before you begin

12
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
Installation Guidelines
Review the following guidelines before starting installation activities.
General guidelines
Follow these general guidelines and practices:
Read this document completely before starting any installation activities.
Only qualified, professional personnel should perform the procedures described in this
document.
Follow standard safety precautions when performing installation and maintenance tasks.
Always wear standard safety gear when performing installation and maintenance tasks
(hardhats/safety headgear, reflective vest, eye protection, insulated gloves).
For safety, keep bystanders and other unauthorized personnel away from work
operations at all times.
If the E7-2 is to be installed in an outdoor cabinet, do not perform installation activities
during thunderstorms or when the threat of lightning is present.
The E7-2 installation kit includes power and ground cables that are 12 feet (3.66 m) in
length. If you cannot locate the E7-2 within 12 feet (3.66 m) of the power/ground
source, you must supply your own cables.
Calix offers a 3rd party DC distribution panel with dual power feed, 10+10 (A+B) GMT
fuse positions (Calix part number 100-02234).

13
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
Safety Recommendations and Notices
WARNING! The intra-building port(s) of the equipment or subassembly is
suitable for connection to intra-building or unexposed wiring or cabling only.
The intra-building port(s) of the equipment or subassembly MUST NOT be
metallically connected to interfaces that connect to the Outside Plant (OSP)
or its wiring. These interfaces are designed for use as intra-building
interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE,
Issue 4) and require isolation from the exposed OSP cabling. The addition
of Primary Protectors is not sufficient protection in order to connect these
interfaces metallically to OSP wiring.
WARNING! This product should be protected by a surge protector that
meets the applicable criteria of GR-974-CORE or GR-1361-CORE. Failure
to utilize an appropriate surge protector could result in susceptibility to
lightning surges or create a potential hazard due to power faults.
WARNING! Only qualified technical personnel should perform the
procedures in this document. These procedures involve potentially
hazardous activities that could cause injury to untrained personnel.
DANGER! Risk of high power current surge and electric shock. Read and
understand all power procedures before performing tasks. Take necessary
precautions and use appropriate insulated tools when working with power.
This equipment must be installed, operated, and serviced by qualified
technical personnel only.
DANGER! CLASS 1 LASER PRODUCT. INVISIBLE LASER RADIATION
PRESENT. Fiber optic radiation can cause severe eye damage or
blindness. Do not look into the open end of an optical fiber.
ESD ALERT! Beware of electrostatic discharge. Follow standard ESD
precautions. Always wear a grounded ESD wristband to avoid damaging the
electronic equipment.

14
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
Required Items
Verify that the following items are on hand before you begin the installation.
Calix-supplied items
The Calix E7-2 installation package includes the following items:
Qty Description
1 Calix E7-2 two-slot chassis (1 RU)
1 Calix E7-2 fan module
1 Calix E7-2 blank line card
4 Rack mounting ears; 19-inches (48.26-cm) (2 ea.) and
23-inches (58.42-cm) (2 ea.)
8 Flathead Phillips screws, 4-40 x .1875 inches (.6 cm)
(for attaching mounting ears)
4 Self-tapping mounting screws, 12-24
(for rack mounting)
1 Power cable, A/B inputs;18 AWG, 12 ft (3.66 m)
1 Ground cable; 8 AWG, 12 ft (3.66 m), plus termination hardware (2 ea. washers,
nuts)
1 Spare 2-hole ground lug (8 AWG)
4 Cable tie mounts
(for RJ-21 connector using a 90 degree exit)
4 Panhead Phillips screws, 4-40 x .25 inches (.6 cm)
(for securing cable tie mounts to RJ-21 connectors that use a 90 degree exit)
The following optional equipment is ordered and packaged separately, as required:
Pluggable transceiver modules (required for line termination)
Fiber guide suitable for all E7-2 deployments, including ETSI racks
Cool air intake and rear heat exhaust system to redirect airflow to the rear of the chassis
RS-232 console cable (DB-9F to RJ-11M) to connect to a PC for console management

15
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
User-supplied items
The following user-supplied tools and materials are required for installation.
Power drill with universal sockets and screwdriver bits
Socket wrench/nut driver set (standard)
Screwdriver set (standard)
Cable ties (tie-wraps)
Wire stripper
Compression crimping tool
Digital multi-meter
Fiber splicer
Fiber jumpers (LC for Ethernet interfaces; SC/UPC for GPON interfaces)
Fiber management system (distribution, ducts, raceways, etc.)

16
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
Preparations Before You Begin
Complete the following preparations before you begin the installation process.
Site requirements
Before starting the installation, verify that the following conditions are true:
All materials are onsite and inventoried.
An equipment rack and grounding system are available
Minimum clearances are met for each device.
Access to a -48 VDC power source with fuse-protected distribution is available.
The installation site has restricted access.
Cable lengths and wire gauges are adequate for the services provided.
Thermal budget is accounted for and approved.
Assignments for power, transport, services, alarms, timing, and other interfaces have
been defined.
Determining an installation location
For indoor rack-mounted units, keep the following requirements in mind when choosing an
installation location:
As an environmentally hardened system, the Calix E7-2 is suitable for installation in
network telecommunication facilities including outside plant (OSP) locations.
The E7-2 requires one rack unit (1 RU) of mounting space on a standard 19- or 23-inch
(48.26- or 58.42-cm) equipment rack.
The E7-2 fan module is located on the right side of the unit. The system requires
adequate airflow space on the right side (intake) and left side (exhaust) of the unit for
proper cooling. For this reason, EIA or 23-inch (58.42-cm) racks are preferred over 19-
inch (48.26-cm) telco racks.
Note: Calix offers an optional cool air intake and rear heat exhaust system to assure
adequate airflow. Refer to Installing an Intake/Exhaust System (on page 31) for installation
instructions.
Locate the E7-2 near power supply and ground termination locations.
Note: The power and ground cables supplied with the E7-2 installation kit are 12 feet
(3.66 meters) long.
Power, ground, and alarm wiring at the rear of the E7-2 must be properly secured with
strain relief.
Fibers attached to pluggable transceiver modules on the front of the E7-2 unit must be
appropriately dressed and secured with strain relief to avoid exceeding the manufacturer's
bend radius standards.

17
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
Chapter 3
Installing the Calix E7-2
This section describes how to install the Calix E7-2 chassis and components onto a standard
equipment rack.
Topics Covered
This section covers the following topics:
Installing the E7-2 chassis
Grounding the E7-2 chassis
Connecting DC power to the E7-2 chassis
Installing the E7-2 fan module
Installing E7-2 line cards

18
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
Installing the E7-2 Chassis
This topic describes how to install the E7-2 chassis into an equipment rack.
Calix offers the following rack mount options:
E7-2 vertical mounting kits for vertical chassis orientation in 19- or 23-inch racks
E7-2 ETSI rack mounting kit to provide a 75 mm forward offset limitation from the rack
mounting rail
To install the E7-2 chassis
1. Get a pair of mounting ears and (8) flat head screws from the installation kit.
Note: The kit includes two sets of mounting ears, one pair for 19-inch (48.26-cm) racks
and another for 23-inch (58.42-cm) racks.
2. Attach (2) mounting ears to the E7-2 chassis using supplied hardware. You can install the
ears in a flush-mount or projection-mount position as required.
3. Mount the E7-2 chassis onto the equipment rack:
a. Identify the E7-2 mounting location on the rack.
b. Position the E7-2 chassis against the rack at the identified location, aligning its ear
holes with the counterpart holes on the rack.
c. Install (4) mounting screws to secure the unit in place.

19
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
To install an E7-2 vertical mounting frame
1. Identify the exact mounting location on the equipment rack for the E7-2 mounting
frame. The frame requires approximately 22 inches (55.88 cm) of vertical rack space.
2. Install the mounting frame's top bracket as follows:
a. Orient the bracket with its equipment-mounting flange on the top.
b. Position the bracket against the rack at the identified location, aligning the bracket's
mounting holes with counterpart holes on the rack.
c. Attach the top bracket to the rack using (4) supplied mounting screws (2 per side).
3. Install the mounting frame's bottom bracket as follows:
a. Orient the bracket with its equipment-mounting flange on the bottom.
b. Position the bottom bracket against the rack 19 inches (48.26 cm) below the top
bracket, aligning the bracket's mounting holes with counterpart holes on the rack.
c. Attach the bottom bracket to the rack using (4) supplied mounting screws (2 per
side).

20
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
4. Install the heat deflector above or below the mounting frame (typically above) as follows:
a. Orient the deflector with the baffle directly above the mounting frame's top bracket.
b. Position the deflector against the rack at the identified location, aligning the
deflector's mounting holes with counterpart holes on the rack.
c. Attach the deflector to the rack using (4) supplied mounting screws (2 per side).
After the vertical mounting frame is installed, you can install Calix E7-2 units onto the frame
as required. Mount the E7-2 chassis with its right side (fan tray) on the bottom, to direct
airflow upward.
To install an E7-2 with the ETSI rack mounting kit
1. Get the pair of ETSI rack mounting ears from the installation kit.
2. Attach each mounting ear to the E7-2 chassis as follows:
a. Position the bracket against the side of the chassis, aligning the bracket's (4)
equipment mounting holes with the counterpart holes on the chassis.
b. Attach the mounting ear to the E7-2 chassis using (4) supplied flat head screws.
3. Mount the E7-2 chassis onto the equipment rack:
a. Identify the E7-2 mounting location on the rack.
b. Position the E7-2 chassis against the rack at the identified location, aligning its ear
holes with the counterpart holes on the rack.
c. Install (4) mounting screws to secure the unit in place.
Other manuals for E7-2
1
Table of contents
Other Calix Wireless Access Point manuals
Popular Wireless Access Point manuals by other brands

Pakedge
Pakedge WX-1 quick start guide

EnGenius
EnGenius ENS200 quick start guide

Compex
Compex NetPassage WP18 Quick install guide

H3C
H3C WA2210-AG_INDOORSINGLEBANDAP installation manual

Vimar
Vimar PLANA 14195 quick start guide

Ascent Communication Technology
Ascent Communication Technology AP201C Series Quick reference guide

Beyerdynamic
Beyerdynamic UNITE AP4 installation instructions

Atlantis
Atlantis NetFly AP5 W300N quick start guide

TRENDnet
TRENDnet TPL-110AP - 125Mbps 802.11g Wireless Powerline Access... user guide

EnGenius
EnGenius ENS202EXT Quick installation guide

LEGRAND
LEGRAND DA1101 Instruction/installation sheet

Atlantis Land
Atlantis Land A02-AP2-W54M manual