EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cannon
  6. •
  7. Indoor Fireplace
  8. •
  9. Cannon FFITZROY PROFILE PWR User manual

Cannon FFITZROY PROFILE PWR User manual

Other Cannon Indoor Fireplace manuals

Cannon CANTIB User manual

Cannon

Cannon CANTIB User manual

Cannon FITZPIB User manual

Cannon

Cannon FITZPIB User manual

Cannon FITZPIBPWR User manual

Cannon

Cannon FITZPIBPWR User manual

Cannon FITZIB-SDSEB-NG User manual

Cannon

Cannon FITZIB-SDSEB-NG User manual

Cannon CANTERBUR User manual

Cannon

Cannon CANTERBUR User manual

Cannon CANTERBURY User manual

Cannon

Cannon CANTERBURY User manual

Cannon FITZFS-SDSEB-NG User manual

Cannon

Cannon FITZFS-SDSEB-NG User manual

Cannon CANTERBURY User manual

Cannon

Cannon CANTERBURY User manual

Cannon Fitzroy Inbuilt User manual

Cannon

Cannon Fitzroy Inbuilt User manual

Cannon Canterburry User manual

Cannon

Cannon Canterburry User manual

Cannon Latitude User manual

Cannon

Cannon Latitude User manual

Cannon Fitzroy User manual

Cannon

Cannon Fitzroy User manual

Cannon CANTERBURY User manual

Cannon

Cannon CANTERBURY User manual

Cannon Fitzroy Powerflue In-built User manual

Cannon

Cannon Fitzroy Powerflue In-built User manual

Cannon FITZPIB-02-NG User manual

Cannon

Cannon FITZPIB-02-NG User manual

Cannon CANTERBURY FREESTANDING User manual

Cannon

Cannon CANTERBURY FREESTANDING User manual

Cannon Fitzroy canterbury User manual

Cannon

Cannon Fitzroy canterbury User manual

Cannon FITZIB-SDENB User manual

Cannon

Cannon FITZIB-SDENB User manual

Cannon CANT User manual

Cannon

Cannon CANT User manual

Cannon FITZPIBPWR-02-NG User manual

Cannon

Cannon FITZPIBPWR-02-NG User manual

Cannon Canterbury CANTIB-SDEEB User manual

Cannon

Cannon Canterbury CANTIB-SDEEB User manual

Cannon CANTERBURY CANTIB-02-NG User manual

Cannon

Cannon CANTERBURY CANTIB-02-NG User manual

Cannon FITZP User manual

Cannon

Cannon FITZP User manual

Popular Indoor Fireplace manuals by other brands

Brigantia 35-DVRS31N-2 User's installation, operation and maintenance manual

Brigantia

Brigantia 35-DVRS31N-2 User's installation, operation and maintenance manual

Nordpeis Bergen Installation and user manual

Nordpeis

Nordpeis Bergen Installation and user manual

Superior BCT2536TMN Installation and operation instructions

Superior

Superior BCT2536TMN Installation and operation instructions

Quadra-Fire 5100I-GD-B owner's manual

Quadra-Fire

Quadra-Fire 5100I-GD-B owner's manual

Renaissance RUMFORD 1000 user manual

Renaissance

Renaissance RUMFORD 1000 user manual

Lacunza IV-800 Instruction book

Lacunza

Lacunza IV-800 Instruction book

Baxi 940 Installer and owner guide

Baxi

Baxi 940 Installer and owner guide

Dru Maestro 60/2 Tall RCH installation manual

Dru

Dru Maestro 60/2 Tall RCH installation manual

Diamond Fireglass SS-O22 General assembly, installation, and operation instructions

Diamond Fireglass

Diamond Fireglass SS-O22 General assembly, installation, and operation instructions

HearthStone Windsor Bay 8830 Owner's manual and installation guide

HearthStone

HearthStone Windsor Bay 8830 Owner's manual and installation guide

Napoleon ASCENT B42 quick start guide

Napoleon

Napoleon ASCENT B42 quick start guide

Enviro E33GI owner's manual

Enviro

Enviro E33GI owner's manual

Smeg L30 FABE Installation & user's instructions

Smeg

Smeg L30 FABE Installation & user's instructions

KEDDY K700 Installation instructions care and firing instructions

KEDDY

KEDDY K700 Installation instructions care and firing instructions

Godin 3451 manual

Godin

Godin 3451 manual

Jøtul Jotul GI 535 DV IPI New Harbor Installation and operation instructions

Jøtul

Jøtul Jotul GI 535 DV IPI New Harbor Installation and operation instructions

Desa CCFPDFT Owner's operating & installation manual

Desa

Desa CCFPDFT Owner's operating & installation manual

Miles Industries Vogue 1300IRN Installation & operating instructions

Miles Industries

Miles Industries Vogue 1300IRN Installation & operating instructions

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

CANNON
FITZROY PROFILE PWR
TO SUIT MOCK FIREPLACE INSTALLATIONS
INSTALLATION INSTRUCTIONS FOR FITMENT
INTO A COMBUSTIBLE ENCLOSURE
This heater is for use with Natural Gas
Read these instructions in conjunction with heater
installation instructions
REF: F3084-C
REVISION “C” DATED: FEB 2007
CONTENTS NOTES
ITEM PAGE.
GENERAL AND SAFETY WARNINGS P ge 1
a
CLEARANCE FROM COMBUSTIBLE P ge
a2
OVERALL DIMENSIONS OF CABINET P ge
a 3
- 5
Pa 4
g
e
FITMENT OF SPACER BRACKETS AND BLANKET
CAVITY CLEARANCE REQUIREMENTS Pa
ge 6
7
INSTALLATION DETAIL ADVICE P g
a e
g
CONTACT FOR MAINTENANCE ATTENTION a 8
e
P
Page 9.
GENERAL
THIS HEATER SHALL ONLY BE INSTALLED BY AN AUTHORIZED
PERSON. THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS, AG 5601,
MUNICIPAL BUILDINGS CODES, ELECTRICAL WIRING REGULATIONS
AND ANY OTHER STATUTORY REGULATIONS.
TO CONFORM WITH THE AUSTRALIAN STANDARDS APPROVAL
REQUIREMENTS, THE SPACERS MUST BE PERMANENTLY FITTED
TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLE
MATERIALS.
THESE MOCK FIREPLACE INSTALLATION INSTRUCTIONS AND
SAFETY WARNINGS SHALL BE READ IN CONJUNCTION WITH THE
HEATER INSTALLATION BOOKLET AND THE SAFETY WARNING IN
THAT MANUAL. (SEE PAGES 3&4)
Page 1.
IMPORTANT NOTE:
WHEN INSTALLING THIS POWER FLUE HEATER INTO A MOCK
FIREPLACE , A MOCK FIREPLACE INSTALLATION KIT MUST BE USED.
FOR INSTALLATION INTO A (MOCK) COMBUSTIBLE FIREPLACE
CONSTRUCTED FROM TIMBER AND / OR PLASTERBOARD, THE FLUE
WILL NEED TO BE SUPPORTED TO MAINTAIN MIN CLEARANCES
FROM ANY COMBUSTIBLE MATERIALS.
THE HEATER MUST BE INSTALLED WITH IT’S INTEGRAL FLUE
CORRECTLY INSTALLED (SEE INSTALLATION INSTRUCTION BOOKLET)
FOR THIS HEATER TO OPERATE PROPERLY. IF THE FLUE SYSTEM
IS NOT CORRECTLY INSTALLED AND MAINTAINED, POISONING BY
CARBON MONOXIDE (CO) COULD RESULT AND POSSIBLY CAUSE
DEATH.
THE APPLIANCE SHOULD BE INSPECTED PRIOR TO USE, WITH
REGULAR INSPECTIONS (ANNUALLY) TO BE MADE BY A LICENSED
SERVICE PERSON. IT IS IMPORTANT THAT CIRCULATING AIR
PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN, DIRT AND LINT
FREE, FOR A SAFE AND EFFICIENT OPERATION OF THE HEATER.
SAFETY WARNINGS
MAINTENANCE
IF YOUR HEATER REQUIRES ATTENTION CONTACT:
SAMPFORD AND STAFF PTY LTD
ON
PH 1300 727 421
FAX 1300 727 425
Page 8.
CLEARANCE FROM COMBUSTIBLES.
(SEE FIG 1.)
INSTALLATION DETAIL
MIN 630 mm
MAX 650 mm
MIN 745 mm
MAX 840 mm
CLEARANCE FROM COMBUSTIBLES.
BETWEEN HEATER CABINET AND OTHER
COMBUSTIBLE SURFACES.
* 50 mm CLEARANCE FROM BOTH TOP
AND SIDE SURFACES.
* 50 mm CLEARANCE FROM REAR.
* 50 mm CLEARANCE BETWEEN SIDE OF
THE HEATER FRONT AND
COMBUSTIBLES.
ADDITIONAL CLEARANCES ARE SPECIFIED.
(SEE FIG 6, PAGE 6)
FIG 1.
Page 2. Page 7.
DEPTH OF CAVITY : MIN 440 mm
MAX 740 mm
REFER TO THE INSTALLATION BOOKLET SUPPLIED WITH THE
HEATER
CAVITY REQUIREMENTS. OVERALL DIMENSIONS OF THE INSERT CABINET.
(SEE FIG 2 AND 3. )
735mm
FIG 3.
FIG 6.
Page 3.
Page 6.
* HEIGHT 625 mm
* WIDTH 735 mm
* DEPTH 430 mm
625 mm
430mm
THE HEATER FOR INSTALLATION INTO A MOCK
FIREPLACE IS SUPPLIED WITH THE FOLLOWING PARTS.
F1404 REAR BRACKETS
F1405 TOP & SIDE SPACER BRACKETS
F1406 INSULATION BLANKET (ALREADY FITTED TO THE HEATER)
F3084 INSTRUCTION BOOKLET
2 OFF
4 OFF
1 OFF
1 OFF
FIG 2.
CLEARANCES FOR INSTALLATION INTO A COMBUSTIBLE ENCLOSURE
USING A MOCK FIREPLACE KIT. (Pt No F3084)
(SEE FIG 6.)
CEILING
MANTLE
300 MIN
1000 MIN
CLEARANCE
380
485
605
650 MIN
440 MIN
695
50 50
795 MIN
PLAN VIEW
SIDE VIEW
160 mm
GAS SUPPLY
10 mm
75 mm GAS SUPPLY
FLUE DIA 100 mm
FLUE TERMINAL
Page 4. Page 5.
FITMENT OF SPACER BRACKETS
1. THE SPACER LOCATION ARE MARKED ON THE HEATER
CABINET INSERT. (SEE FIG 4 )
2. REMOVE THE FIXING SCREWS NEXT TO THE SHADED SECTIONS
MARKED ON THE HEATER CABINET INSERT.
( SEE FIG 4.)
3. FIT TOP AND SIDE BRACKETS TO HEATER CABINET ON DIAGONAL
CORNERS AS SHOWN EACH SIDE. FIT AS PER SPACER BRACKET
LOCATIONS USING EXISTING SCREW POSITIONS
.
4. FIT REAR SPACER BRACKETS TO HEATER CABINET ON DIAGONAL
CORNERS AS SHOWN. ( SEE FIG 5.)
( SEE FIG 5.)
FIG 4.
FLUE ENTRY
FIXING SCREWS
No8 x 3/8" SELF TAPPING
REAR BRACKET
TOP & SIDE
BRACKETS
INSULATIVE BLANKET
PLACED ON TOP OF
HEATER CABINET.
FIG 5.
FOR MOCK
INSTALLATION
ONLY.
SCREW BRACKETS
HERE
DI NA ERS
AGO L CORN
AO A CR ER
DI G N L O N S
Page 4. Page 5.
FITMENT OF SPACER BRACKETS
1. THE SPACER LOCATION ARE MARKED ON THE HEATER
CABINET INSERT. (SEE FIG 4 )
2. REMOVE THE FIXING SCREWS NEXT TO THE SHADED SECTIONS
MARKED ON THE HEATER CABINET INSERT.
( SEE FIG 4.)
3. FIT TOP AND SIDE BRACKETS TO HEATER CABINET ON DIAGONAL
CORNERS AS SHOWN EACH SIDE. FIT AS PER SPACER BRACKET
LOCATIONS USING EXISTING SCREW POSITIONS
.
4. FIT REAR SPACER BRACKETS TO HEATER CABINET ON DIAGONAL
CORNERS AS SHOWN. ( SEE FIG 5.)
( SEE FIG 5.)
FIG 4.
FLUE ENTRY
FIXING SCREWS
No8 x 3/8" SELF TAPPING
REAR BRACKET
TOP & SIDE
BRACKETS
INSULATIVE BLANKET
PLACED ON TOP OF
HEATER CABINET.
FIG 5.
FOR MOCK
INSTALLATION
ONLY.
SCREW BRACKETS
HERE
DI NA ERS
AGO L CORN
AO A CR ER
DI G N L O N S
CAVITY REQUIREMENTS. OVERALL DIMENSIONS OF THE INSERT CABINET.
(SEE FIG 2 AND 3. )
735mm
FIG 3.
FIG 6.
Page 3.
Page 6.
* HEIGHT 625 mm
* WIDTH 735 mm
* DEPTH 430 mm
625 mm
430mm
THE HEATER FOR INSTALLATION INTO A MOCK
FIREPLACE IS SUPPLIED WITH THE FOLLOWING PARTS.
F1404 REAR BRACKETS
F1405 TOP & SIDE SPACER BRACKETS
F1406 INSULATION BLANKET (ALREADY FITTED TO THE HEATER)
F3084 INSTRUCTION BOOKLET
2 OFF
4 OFF
1 OFF
1 OFF
FIG 2.
CLEARANCES FOR INSTALLATION INTO A COMBUSTIBLE ENCLOSURE
USING A MOCK FIREPLACE KIT. (Pt No F3084)
(SEE FIG 6.)
CEILING
MANTLE
300 MIN
1000 MIN
CLEARANCE
380
485
605
650 MIN
440 MIN
695
50 50
795 MIN
PLAN VIEW
SIDE VIEW
160 mm
GAS SUPPLY
10 mm
75 mm GAS SUPPLY
FLUE DIA 100 mm
FLUE TERMINAL
CLEARANCE FROM COMBUSTIBLES.
(SEE FIG 1.)
INSTALLATION DETAIL
MIN 630 mm
MAX 650 mm
MIN 745 mm
MAX 840 mm
CLEARANCE FROM COMBUSTIBLES.
BETWEEN HEATER CABINET AND OTHER
COMBUSTIBLE SURFACES.
* 50 mm CLEARANCE FROM BOTH TOP
AND SIDE SURFACES.
* 50 mm CLEARANCE FROM REAR.
* 50 mm CLEARANCE BETWEEN SIDE OF
THE HEATER FRONT AND
COMBUSTIBLES.
ADDITIONAL CLEARANCES ARE SPECIFIED.
(SEE FIG 6, PAGE 6)
FIG 1.
Page 2. Page 7.
DEPTH OF CAVITY : MIN 440 mm
MAX 740 mm
REFER TO THE INSTALLATION BOOKLET SUPPLIED WITH THE
HEATER
GENERAL
THIS HEATER SHALL ONLY BE INSTALLED BY AN AUTHORIZED
PERSON. THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS, AG 5601,
MUNICIPAL BUILDINGS CODES, ELECTRICAL WIRING REGULATIONS
AND ANY OTHER STATUTORY REGULATIONS.
TO CONFORM WITH THE AUSTRALIAN STANDARDS APPROVAL
REQUIREMENTS, THE SPACERS MUST BE PERMANENTLY FITTED
TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLE
MATERIALS.
THESE MOCK FIREPLACE INSTALLATION INSTRUCTIONS AND
SAFETY WARNINGS SHALL BE READ IN CONJUNCTION WITH THE
HEATER INSTALLATION BOOKLET AND THE SAFETY WARNING IN
THAT MANUAL. (SEE PAGES 3&4)
Page 1.
IMPORTANT NOTE:
WHEN INSTALLING THIS POWER FLUE HEATER INTO A MOCK
FIREPLACE , A MOCK FIREPLACE INSTALLATION KIT MUST BE USED.
FOR INSTALLATION INTO A (MOCK) COMBUSTIBLE FIREPLACE
CONSTRUCTED FROM TIMBER AND / OR PLASTERBOARD, THE FLUE
WILL NEED TO BE SUPPORTED TO MAINTAIN MIN CLEARANCES
FROM ANY COMBUSTIBLE MATERIALS.
THE HEATER MUST BE INSTALLED WITH IT’S INTEGRAL FLUE
CORRECTLY INSTALLED (SEE INSTALLATION INSTRUCTION BOOKLET)
FOR THIS HEATER TO OPERATE PROPERLY. IF THE FLUE SYSTEM
IS NOT CORRECTLY INSTALLED AND MAINTAINED, POISONING BY
CARBON MONOXIDE (CO) COULD RESULT AND POSSIBLY CAUSE
DEATH.
THE APPLIANCE SHOULD BE INSPECTED PRIOR TO USE, WITH
REGULAR INSPECTIONS (ANNUALLY) TO BE MADE BY A LICENSED
SERVICE PERSON. IT IS IMPORTANT THAT CIRCULATING AIR
PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN, DIRT AND LINT
FREE, FOR A SAFE AND EFFICIENT OPERATION OF THE HEATER.
SAFETY WARNINGS
MAINTENANCE
IF YOUR HEATER REQUIRES ATTENTION CONTACT:
SAMPFORD AND STAFF PTY LTD
ON
PH 1300 727 421
FAX 1300 727 425
Page 8.