Caple DD930BK User manual

DD930BK
Downdraft
Induction
Hob
Downdraft Induction Hob
Technical information



Item Part Code Description Qty
175072099999 LA31 300MM S-DD2 ACTUATOR GROUP 1
242030999999 TRANSFORMER 50 W 1
375071505033 ASS. R. FILTRO S-DD5 90 2014 LFI-N033 1
475025729011 ASS. R. PANN. SDD5 90 GLASS BL X304 MAGNETI 1
542041999999 CAPACITOR 5MF 1
651070102737 FRONT JOINT 1
777001052999 A.S.A. SDD2 CON MOTORE 1
842030122320 TRANSFORMER EL. DC 12V EFU 122320 1
975062200140 ASS. R. BORDO INST. S-DD9 1
10 90002420417 LIBR. ISTR. S-DDH1 CAPLE 1
11 51070102735 PIPE SIDE CONNECTION 1
12 75025100335 BUTTON 6A 1
DD930BK
- Downdraft Induction Hob
13 60041092553 MAGNET 20X3 1
14 75074516018 S-DD2 CHAIN 1
15 75076000188 ASS. R. FRONTALE GLASS BLACK S-DDH CAPLE 1
16 75162200136 ASS. R. BORDO CARCASSA S-DDH1 1
17 75159217374 ASS. R. STAFFE DX-SX S-DDH1 1
18 75119211533 ASS. R. CABL. S-DD2-L EM S.UK. LED 1
19 75470199999 EMERGENCY SWITCH/START NEON 1
20 75072600100 S-DD2 WIRING BOX 1
21 75071439999 WIRING BOX SET 1
22 75010515012 ASS. R. BARRA LEDD 515mm 10W 12V 4500°K 1
23 60180030021 S-DD1 CM 90 GEAR ROD 1
24 60180030400 S-DD1 GEAR 1
25 51501000015 S-DD1 ROD BRASS BUSH 1
26 75025700150
A
SS. R. COPERTURA CALAMITE E MICRO SDD5 XS304 1
27 63504000312 MAGNETIC SENSOR 1
28 60181734380 SLIDE KA1730/380 M4 1
29 44001599999 MAIN BOARD S-DD1 POWER 1
30 44002409999 MAIN WIRING BOARD S-DD2_L 1
31 75102300076
A
SS. R. COPERTURA LED SDD5 XS304 1
32 81020 RIDUZ.DA 230X80 A DIAM=150_V2 NERO 1
33 75021002150 METAL PLATE 1
34 75036099999
A
SS. R. DUE CREMAGLIERE DD PDI-A036 1
40 75729063717
A
SS. R. VETRO PIANO COTTURA S-DDH1 90 NEUTRO 1
41 75031045001 ASS. R. S-DDH INDUCTION PLATE OCTA-A 1
42 75031045002 ASS. R. S-DDH INDUCTION PLATE OCTA-B 1
43 75031045003
A
SS. R. S-DDH INDUCTION PLATE OCTA-C 1
44 75102450009
A
SS. R. PULSANTIERA T.C. VERT. S-DDH1 1
45 75031045011
A
SS. R. S-DDH1 FILTER BOARD 1

Item Part Code Description Qty
DD930BK
- Downdraft Induction Hob
46 75031037001
A
SS. R. S-DDH1 POWER BOARD 1
47 75031045012 ASS. R. S-DDH1 TOUCH CONTROL SLAVE 1
48 75031045013 ASS. R. S-DDH1 TOUCH CONTROL MASTER 1
49 75030002001 ASS. R. S-DDH SWITCH BOX COVER 1
50 75030005001
A
SS. R. S-DDH CABLE BLOCKING FOR INDUCTION 1
51 75030006001
A
SS. R. S-DDH JUMPER FOR INDUCTION 1
52 44029999544 CAVO PIATTINA S-DDH1 EFI-A544 1
53 75030029001
A
SS. R. S-DDH COOKERHOOD TOUCH CONTROL RES
A
1
54 75031037002
A
SS. R. S-DDH FUN 1
55 75030019001
A
SS. R. SET ACCESSORIES 1
56 75030307001 ASS. R. COOKERHOOD TOUCH CONTROL COVER 1

DD600BK
DD600BK
DD600SS
DD605BK
DD605SS
DD900BK
DD900SS
DD910BK
DD910SS
DD910WH
DD910SS
Trouble shooting

2
PROBLEM
THE DOWNDRAFT EXTRACTABLE UNIT DOES
NOT OPEN, THE SUCTIONING SYSTEM DOES
NOT WORK AND THE PUSH-BUTTON PANEL IS
OFF.
Possible solutions
Check if the network voltage is working
Check if the red power button is in on position
Check if the male and female connections in the 9 pole connector
are connected properly
Check if the circuit of the grease filters panel presence is closed
Check if the grease filters cover panel is disengaged
Check if the grease filter panel presence keys are working properly
Check integrity of the grease filters panel presence residual circuit
Replace the main electrical system board
Replace the power supply system board
Check the connection of the push-button panel connector
Replace the upper front panel
PROBLEM
THE EXTRACTABLE UNIT OPENS BUT THE
SUCTIONING UNIT DOES NOT WORK AT ANY
SPEED
Check if the 6 pole connector of the suctioning unit cable is
connected properly to the wiring and if all the connector pins are
properly inserted into the connector itself.

3
Check if the suctioning unit 6 pole connector wires in the main
electrical system board are connected properly and if all the
green connector pins are properly inserted inside the board.
Only with on-board motor Check if the suctioning unit 6 pole
connector is connected properly and if all the connector pins are
properly inserted inside the connector itself
Check if the relays inside the board switch over properly with
pressure of speed change from the push-button.
Replace the main electrical system board
Replace the suctioning unit
PROBLEM
THE BODY LINER IS DAMAGED
Possible solutions
Replace the body liner
PROBLEM
THE SUCTIONING SYSTEM WORKS PROPERLY
BUT THE EXTRACTABLE UNIT DOES NOT OPEN
Possible solutions
Check if the electrical system connectors are connected properly .
Check the actuator inside connection
Check if the electro-mechanical transformer placed inside the
electrical system box is working properly
Replace the actuator.

4
PROBLEM
THE EXTRACTABLE UNIT RE-OPENS BY ITSELF
DURING AND AFTER ITS CLOSING
Possible solutions
Check if the safety sensor is working properly
Carry out the calibration reset
Make the calibrationReplace the push-button front panel
Replace the main electrical system board
PROBLEM
THE PUSH-BUTTON PANEL DOES NOT LIGHT
UP
Possible solutions
Check if the push-button connector is connected properly
Replace the push-button panel
Replace the main electrical system board
PROBLEM

5
LIGHTING DOES NOT LIGHT UP
(ONLY FOR SDD2-L)
Replace the neon tube
Check if the neon supports are not damaged and are connected
properly.
Replace the neon tube supports
Check if the ballast input voltage is 230V
Replace the ballast.
PROBLEM
THE FILTERS ALARM SIGNAL AFTER 30 HOURS
WORKING DOES NOT RESET WHEN PRESSING
THE TIMER KEY
Possible solutions
Disconnect and restore power supply
Replace the push-button front panel.
Replace the main electrical system board.
PROBLEM
THE DOWNDRAFT AIR –CAPACITY IS
INADEQUATE
Check the suction duct length
Check the air outlet pipe section
Make sure there are no obstructions along the pipe
Check if the charcoal filters are still in good conditions in case of
Filtering version

6
Check efficiency of all speeds in the suctioning unit .
Check if the non-return valve tongues can move freely
PROBLEMa RISCONTRATo
THE EXTRACTABLE UNIT OPENS, BUT IT DOES
NOT STOP WHEN REQUIRED, AFTER 180 mm,
AND THE SUCTIONING SYSTEM WORKS WHEN
THE EXTRACTABLE UNIT IS COMPLETELY
OPEN, AND STOPS WHEN THE EXTRACTABLE
UNIT IS COMPLETELY CLOSED.
(ONLY FOR SDD2)
Check if the 180mm sensor is working properly.
Replace the 180mm sensor

7
PROBLEMA RISCONTRATO
1. THE DOWNDRAFT EXTRACTABLE UNIT
DOES NOT OPEN, THE SUCTIONING
SYSTEM DOES NOT WORK AND THE
PUSH-BUTTON PANEL IS OFF.
POSSIBLE SOLUTION
CHECK IF THE NETWORK VOLTAGE IS WORKING.
Make sure the magnetic circuit breaker ( life-saving switch) has not
tripped and the system protection fuses are in good conditions. In
this case you need to call a specialized technician in order to fix the
problem.
CHECK IF THE RED POWER BUTTON IS IN ON POSITION
ON
OFF

8
CHECK IF THE MALE AND FEMALE CONNECTIONS IN THE 9
POLE CONNECTOR ARE CONNECTED PROPERLY
ATT: NEI MODELLI SDD2 E SDD2L I CONNETTORI NON SONO
DISPOSTI NELLO STESSO MODO INOLTRE NEL MODELLO SDD2-
L NON E’ PRESENTE IL CONNETTORE DI RETE.
Disconnect power supply by pressing the red button placed in the
electrical system box
Release the movable connector wires by removing the black
sheath.
OFF

9
Check if the connector inner contacts are inserted properly, by
using a screwdriver. Carry out this check in both the fixed and the
movable connectors.
Nel connettore a 9 poli sono presenti 7 fili nel modello SDD2-L
mentre 9 fili nel modello SDD2 (dato che in questo modello è
presente il sensore dei 180mm) e precisamente:
Grease filters panel presence buttons
PIN 3 RED COLOUR
PIN 6 BLACK COLOUR
Magnetic safety circuit breaker
PIN 4 YELLOW COLOUR
PIN 7 GREY COLOUR
Actuator
PIN 9 BROWN COLOUR
PIN 8 BLUE COLOUR
Ground connection
PIN 5 yellow/green

10
sensore magnetico Cm. 180 ( solo per SDD2)
PIN 2 Colore viola
PIN 1 Colore bianco
Schemi elettrici
SDD2-L
SDD2

11
IMPIANTO ELETTRICO SDD2-L

12
IMPIANTO ELETTRICO SDD2

13
VERIFICARE CHE IL CIRCUITO DELLA PRESENZA PANNELLO FILTRI
SIA CHIUSO.
“The downdraft is equipped with buttons, placed behind the grease
filters covering panel which, in the case of opening, prevent the
downdraft from starting any functions. The cooker-hood is packaged by
the manufacturer and the panel is carefully secured with an adhesive
tape, in order to prevent it from being disengaged during transport.
If the adhesive tape is removed before installation operations are
completed , it is likely that the panel will open when the extractable unit
is closed , preventing the cooker-hood from proper working.
Disconnect the 9 pole connector
Set the multimeter in the “ohm” function and place the test prods in
the female connector of the downdraft panel into the pins
corresponding to the red and black wires of the male connector .

14
If the multimeter shows “000” continuity it means that the circuit
is closed and the panel is positioned properly.
If the multimeter shows NO continuity it means that the circuit is
open somewhere and the downdraft does not work.
CHECK IF THE PANEL IS UNHOOKED
If the extractable unit is closed and the panel accidentally
unhooks , causing the opening of the contact of the filters
panel position , it is necessary to hook it again in order to
restore operation.
Disconnect the downdraft from the power supply.
OFF

15
Scollegare tutti i connettori.
Remove the brackets which fix the downdraft to the cabinet.
In case of internal motor version, remove the motor fixing
screws and remove the suctioning unit.
.
In case of external motor version (EM) remove the air-outlet
flange
Other manuals for DD930BK
1
Table of contents
Other Caple Hob manuals

Caple
Caple C706G User manual

Caple
Caple C861I User manual

Caple
Caple C994i User manual

Caple
Caple C981G User manual

Caple
Caple C742G User manual

Caple
Caple C876I User manual

Caple
Caple C705G User manual

Caple
Caple C743G User manual

Caple
Caple C864I User manual

Caple
Caple C703G Operating and safety instructions