manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Care Call
  6. •
  7. Door Opening System
  8. •
  9. Care Call CCD4A-2220-EU User manual

Care Call CCD4A-2220-EU User manual

CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENTALERT.IE Silent Alert International
TEL +353 (0)1 247 9007
MOVE KEY DOWN
TO SWITCH ON
Magnetic Activation
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5= Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10= PIR Delay 10 Mins
9& 10 = PIR Delay 15 mins
11= Zone 6
12= Zone 5
13= Zone 4
14= Zone 3
15= Zone 2
16= Zone 1
MOVE KEY DOWN
TO SWITCH ON
PUSH
PUSH
1 2 3 4 5 6 7 8
Configuration switches shown with
cover removed. Do not alter these
without referring to page 2
Status light
Magnet
Test button
Configuration
switch Cover
CCD4A-2220-EU
CARE CALL
MINI MAGNETIC
DOOR MONITOR
USE ALKALINE PP3
9 V BATTERY ONLY
Batch 06/01/14
www.silentalert.ie
Silent Alert International, IRL
Tel: +353 (0)1 247 9007
Keys 1-4 System
Channel
Key 5=10 Sec Delay
Key 6=20 Sec Delay
Keys 5+6=30 Sec Delay
Key 7 Leave ON
Key 8 Not Used
USE WITH MAGNET SUPPLIED
PP3 battery
contacts
Screw cap
Screw cap
CCD4A-2220-EU
CARE CALL
MINI MAGNETIC
DOOR MONITOR
USE ALKALINE PP3
9 V BATTERY ONLY
Batch 06/01/14
www.silentalert.ie
Silent Alert International, IRL
Tel: +353 (0)1 247 9007
Keys 1-4 System
Channel
Key 5=10 Sec Delay
Key 6=20 Sec Delay
Keys 5+6=30 Sec Delay
Key 7 Leave ON
Key 8 Not Used
USE WITH MAGNET SUPPLIED
PP3 Battery
PUSH
PUSH
The light will then will flash
green several times to show the
battery voltage.
9 flashes = 9Volts in the battery.
When a battery is first fitted the
indicator light will flash red then
green a few times then light
solid green & pause briefly.
1. Install a 9 volt PP3 alkaline or lithium battery
making sure to observe the correct polarity.
PUSH
If the light flashes red at this
point the battery is flat
and will need to be replaced.
To repeat the battery check remove the battery, press the test
button then re-insert the battery to start the sequence again.
PUSH
2.
To test the unit press the
button on the front of the unit.
Alternatively the supplied
magnet can be used to trigger
the unit by swiping it through
the pickup area.
The monitor is activated using an internal reed
switch and a magnet.
Test Button
Magnetic
switch
pickup area
NOTE* The magnet must pass within 1cm of
the pickup area to activate the unit.
3.
Secure the Mini Monitor
to the door frame
as close as possible to the
edge of the door using the
supplied screws.
The Magnet must pass
within 1cm of the pickup
area to trigger the unit.
PUSH
PUSH
4. We recommend mounting the monitor opposite to the
door hinge. The magnet does not need to be in close proximity
to the pickup area when the door is closed as the unit is
triggered when the magnet passes through the pickup area.
The magnet needs to pass within 1cm of the pickup area as
the door is opened. It is possible to mount the monitor in a
variety of positions as shown in the diagram. Experiment to
find the best position before fixing to the door frame.
Once the optimum position has been established the magnet
should be secured to the door frame using the sticky pad or
screws provided.
PUSH
Deactivating & reactivating the door monitor
PUSH
PUSH
Press and hold the test button until the light
flashes red, then release. This will
deactivate the door sensor.
Press and hold the test button until the light
flashes green, then release. This will
reactivate the door sensor.
Care
Call
Quick start guide CCD4A-2220-EU
Care Call Mini Magnetic Door Monitor
Any questions? Call us on +353 (0)1 247 9007
CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENTALERT.IE Silent Alert International
TEL +353 (0)1 247 9007
MOVE KEY DOWN
TO SWITCH ON
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5= Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10= PIR Delay 10 Mins
9& 10 = PIR Delay 15 mins
11= Zone 6
12= Zone 5
13= Zone 4
14= Zone 3
15= Zone 2
16= Zone 1
MOVE KEY DOWN
TO SWITCH ON
1.
To change the zone you need to
reset the monitor:
Remove the battery,
press the push button,
replace the battery.
Changing the Zone
The unit will by default cause zone 1 on the pager or signwave to light.
PUSH
Press and release the
button whilst the light
is green. The light will
flash red once, twice
then three times and
so on up to twelve.
3.
PUSH
To set the zone
number, briefly press
the test button at the
desired number of
flashes.
The indicator light will
flash green to confirm
the selection.
4.
The monitor will then
perform the battery voltage
level display and start as
normal. Press the test button
to confirm the correct zone
has been selected.
PUSH
1.
1 2 3 4 5 6 7 8
Remove the control key cover by
with a small flat bladed
screwdriver.
Key 7 will already be set. This
must NOT be switched off.
To activate the trigger delay move
key 5 to the on position.
5.
PUSH
After the flashing red/
green startup
sequence the light will
shine constant green.
2.
Setting trigger delays
It is possible to set trigger delays allowing a set amount of time to pass for the user to clear the door before
the monitor will transmit.
PUSH
Now when the door is
opened the monitor will flash
red for 10 seconds.
If the door doesn't shut
within this time the monitor
will transmit.
2.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
The delay can
be increased if required.
3.
1 2 3 4 5 6 7 8
10
seconds
1 2 3 4 5 6 7 8
20
seconds
1 2 3 4 5 6 7 8
30
seconds
Changing the system channel code
NOTE. In most cases it is not necessary to change the system code. However, when one or
more systems are in close proximity, system codes can be used to avoid interference from
other Care Call systems using up to a maximum of 16 channels.
The monitor is supplied with no
system code switches set (system code 1).
For reference this is the factory setting
should you need to re-set the unit.
System codes can be set using
key switches 1 - 4.
The diagram to the right shows the 16
possible combinations.
Be sure that the same system code is set on
the receiver to be used and any other
monitoring options in that system.
23456 7 8
1
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
9
1 2 3 4 5 6 7 8
10
1 2 3 4 5 6 7 8
12
1 2 3 4 5 6 7 8
11
1 2 3 4 5 6 7 8
13
1 2 3 4 5 6 7 8
14
1 2 3 4 5 6 7 8
15
1 2 3 4 5 6 7 8
16
1 2 3 4 5 6 7 8
Advanced settings CCD4A-2220-EU
Care Call Mini Magnetic Door Monitor
Care
Call
Any questions? Call us on +353 (0)1 247 9007

Popular Door Opening System manuals by other brands

Next Systems 900 INSTRUCTIONS MANUAL FOR THE USE & MAINTENANCE

Next Systems

Next Systems 900 INSTRUCTIONS MANUAL FOR THE USE & MAINTENANCE

Nabco GYRO TECH GT-1175 Wiring and Programming Manual

Nabco

Nabco GYRO TECH GT-1175 Wiring and Programming Manual

quiko Swingy QK-SW80 user manual

quiko

quiko Swingy QK-SW80 user manual

Dorex 9500 Series installation instructions

Dorex

Dorex 9500 Series installation instructions

Assa Abloy Norton 6300 Series installation instructions

Assa Abloy

Assa Abloy Norton 6300 Series installation instructions

Iseo MDC IS9100 Mounting instructions

Iseo

Iseo MDC IS9100 Mounting instructions

Assa Abloy RIXSON W50 installation instructions

Assa Abloy

Assa Abloy RIXSON W50 installation instructions

CDVI Digiway SR Easy start guide

CDVI

CDVI Digiway SR Easy start guide

Assa Abloy Besam SL500 manual

Assa Abloy

Assa Abloy Besam SL500 manual

Perko Power R104 manual

Perko Power

Perko Power R104 manual

cinetto PB15 Assembly instructions

cinetto

cinetto PB15 Assembly instructions

Optex SW-1 installation manual

Optex

Optex SW-1 installation manual

Salto Conlan CT1000 v2 installation guide

Salto

Salto Conlan CT1000 v2 installation guide

Benninca VN.15C operating instructions

Benninca

Benninca VN.15C operating instructions

Sesamo Roto K3 Installation and Wiring

Sesamo

Sesamo Roto K3 Installation and Wiring

Assa Abloy Corbin Russwin PED5000 DB Series installation instructions

Assa Abloy

Assa Abloy Corbin Russwin PED5000 DB Series installation instructions

JCM Technologies KEEROLL user manual

JCM Technologies

JCM Technologies KEEROLL user manual

Heicko Radio code G2 user manual

Heicko

Heicko Radio code G2 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.