Caretec Tape King User manual

USER MANUAL
________________________________________________________________________________________
Tape King
Talking Tape Measure,
Clinometer and Spirit Level
EN

2
TABLE OF CONTENTS
1. Introduction 3
2. Description of the Device 3
3. Power Supply 5
4. Tape King’s Functions 6
4.1. Measurement 6
4.2. Measurements with and without the Case 6
4.3. Metric and Imperial System 7
4.4. Difference Measurement - Retain Current Value 7
4.5. Memory and Memory Functions 7
4.6. Clinometer and Spirit Level Functions 8
4.7. Calibration of Clinometer and Spirit Level 9
4.8 History of Last 10 Measurements 9
4.9 Battery Level 10
4.10 Choose Language (only Multilingual-Edition) 10
5. Voice Menu Functions 10
6. Functions of the Keys 10
7. Shortcut Key Combinations 11
8. Safety Instructions 12
9. Trouble-Shooting 12
10. Cleaning 12
11. Technical Data 13
12. Guarantee and Service 13
13. Legal Notice on the Disposal of Electronic Devices 14
13.1 Disposal of Used Electronic Devices 14
13.2 Battery Disposal 14
14. Symbols Used 15
15. Manufacturer 15

3
1. INTRODUCTION
Tape King is a robust, smart talking tape measure for length up to 16.4 feet (~5
meters) and it is a talking clinometer and acoustic spirit level.
2. DESCRIPTION OF THE DEVICE
Read instructions first!
Do not operate Tape King before having read this user manual
and getting accustomed to the device and its accessories. Keep
the manual handy for quick reference and store it together with
the device.

4
Display
A ... Measurement value
B ... Fraction for values in inches
C ... Units
D ... Measurement mode with or without case
E ... Memory usage indicator
F ... Battery level indicator
G ... Indicator for retain value/difference mode
Place the device in front of you with the inclined top on the left hand side and
the belt clip on the far side pointing away from you.
Front
A large LCD display covers the upper part of the front panel. Underneath the
display are four horizontally aligned push-buttons (keys): Far left is the round
on/off key (KEY #1), followed by two smaller oval keys. The left oval key is the
PLUS-key (KEY #2) and it is marked with a single tactile dot. The right oval key
is the MINUS-key (KEY #3) which is marked with two tactile dots. The fourth key
in line is square and is marked with five tactile dots. It is the MENU-key (KEY
#4).
Side
At the bottom side of the device towards the right there is a USB port situated. It
is covered up with a rubber flap. This port is only used as a service port by the
manufacturer and is of no significance for consumers. On the left, narrow side
of the Tape King’s body you will find the actual measuring tape, which can easily

5
be pulled outward. Above the duct for the tape –in the middle of the left slope –
there is a large ribbed button for retracting the tape. Please note that the tape
should only be retracted using this button in order to avoid inaccurate
measurements. To the right of the retraction button is the ribbed speaker which
is followed by the lid of the battery compartment. To open the battery
compartment press the vise action latch and pull the lid to the right. The lid opens
to the right and remains attached to the Tape King at its hinge. In the actual
battery compartment there are two palpable battery contacts.
Rear
On the reverse side of the case you will find a clip to attach Tape King for
example to your belt.
3. POWER SUPPLY
To open the battery compartment press the vise action latch and pull the lid to
the right. The lid opens to the right and remains attached to the Tape King with
its hinge. In the actual battery compartment there are two palpable battery
contacts. Put two 1.5 Volt AAA, LR03 micro batteries or rechargeable batteries
into the battery compartment. Make sure that the negative pole (the smooth side)
of each battery points towards the respective palpable battery contact spring.
After inserting the batteries close the lid of the compartment until it locks in place.
Now the Tape King is ready for use. Turn the device on by pressing KEY #1
(ON/OFF key), the left of the 4 keys. After three minutes of inactivity Tape King
warns with an acoustic signal and turns off automatically. To avoid shut down,
press any key. To turn off the device manually (and in order to save battery
power) press and hold KEY #1 (ON/OFF-key) until you hear the shut down
signal. The device is now turned off.
Caution: If the measuring tape is extended more than 1 foot
(30 cm) always stabilise the loose end with your hand when
retracting the tape to avoid injuries.

6
4. TAPE KING’S FUNCTIONS
4.1. MEASUREMENT
In order to activate the Tape King press and hold KEY #1 (ON/OFF key) until
you hear the starting theme and the announcement ‘0 millimeter’. If the tape was
not retracted properly Tape King will announce “Tape is not in the case!”After
pulling the tape end for a little distance press the retraction button (the ribbed
button above the tape end) until the tape is completely retracted.
With the Tape King turned on and ready for use the procedure for measuring is
as follows:
Press KEY #1 (ON/OFF key) and you will hear the announcement
“0 inches”respectively “0 millimeters” which shows you that the tape is
completely retracted and ready for use.
Pull the tape end forward as far as required. You will hear the
announcement of the exact length.
4.2. MEASUREMENTS WITH AND WITHOUT THE CASE
Sometimes you will need to carry out measurements including the Tape
King’s case (e.g. within door-frames or inside closets). Tape King offers
you this possibility at the press of a button.
Pull the tape end forward as far as required. With a short simultaneous
press onto the KEY #1 (ON/OFF) and the KEY #4 (MENU key) Tape King
will announce the value measured “with case”.
Caution: In case of the Tape Kings announcement “Tape is not
in the case!” first pull the tape out for a couple of inches and then
press the tape retract button in order to completely retract the
tape into the case.

7
To hear the same measurement without the case, press (again
simultaneously) the KEYS #1 and #4 (ON/OFF- and MENU-key). This
function may also be accessed via the menu-function (see below).
4.3. METRIC AND IMPERIAL SYSTEM
In order to switch between the announcements in the metric in the imperial
system, press simultaneously both oval keys (KEY #2 and KEY #3, the PLUS-
and the MINUS-key). This function may also be accessed via the menu-function.
Within the metric system the announcements may be given either in meter,
centimetre and millimetres (for example: 2 meter, 32 centimetre and 5 millimetre)
or in centimetre and millimetre (for example: 232 centimetre and 5 millimetre) as
well as in millimetre only (for example: 2325 millimetre).
Within the imperial system the announcements may be given in decimal feet (for
example: 16,4 feet) or in feet and inches (for example: 16 feet, 4 and 5/16
inches), or in decimal inches (for example: 197,5 inches) as well as in inches
and its fractions (for example: 196 and 3/16 inches).
To switch between options in the respective system (metric or imperial) press
and hold simultaneously the KEY #2 (PLUS-key) and KEY #3 (MINUS-key).
4.4. DIFFERENCE MEASUREMENT - RETAIN CURRENT VALUE
Tape King enables you to retain values independently from the standard
memory function. After announcing of the measurement result press KEY #3
(MINUS-key). Tape King announces the measurement result and status
“retained”. For all subsequent measurements Tape King will always announce
the difference between the retained value and the current value. This function
enables you to compare different length more easily. Press KEY #3 (MINUS-
key) to return to standard measurement mode. You will hear the status info “last
measurement released”and the value is shown on the display. To listen to this
last result Press KEY #1 (ON/OFF-key) to play the announcement of this last
result.
4.5. MEMORY AND MEMORY FUNCTIONS

8
To add a current measurement to the memory, press KEY #2 (PLUS-key) and
the respective announcement follows (for example: “5cm and 3mm added to
memory”). Measurement values can be added in memory to enable measuring
of length of up to three million feet (~568 miles). The values in memory are
permanently stored even if Tape King is turned off. Please, make sure to check
the memory prior saving a new value. If necessary delete the memory.
Recall memory: with pressing and holding the KEY #2 (PLUS-key) the
content of the (total) memory will be recalled. (for example: „total value in
memory is 25 m and 10 cm“). If so far no value has been added to the
memory the tape will announce “memory clear”.
Delete memory: to delete the values in the memory, press and hold the
KEY #3 (MINUS-key) until you hear the announcement „memory deleted“.
4.6. CLINOMETER AND SPIRIT LEVEL FUNCTIONS
Tape King includes the functionality of a spirit level and of a clinometer.
Press and hold KEY #4 (MENU-key) to switch to the spirit level and clinometer
functions or select those functions using the voice menu as described in the
section “Voice Menu Functions” in this manual.
The position of Tape King is signalled with tones. If the device is horizontally or
vertically aligned it produces a steady, continuous tone to indicate that the
alignment is perfectly horizontal or vertical. E.g. alignment with the floor (0°),
with the ceiling (180°) or with a wall (+90° or -90°).
Turning the device clockwise or counter-clockwise out of alignment increases
respectively decreases the pitch of the tone and breaks the continuous tone
into a sequence of tones with increasing pauses.
Caution: Check if the memory already contains measurement
values before you are going to safe a new value.

9
When pressing KEY #1 (ON/OFF-key) for a short time the currently measured
angle will be announced and displayed. Press KEY #4 (MENU-key) to exit the
spirit level and clinometer mode.
4.7. CALIBRATION OF CLINOMETER AND SPIRIT LEVEL
You ought to calibrate Tape King’s spirit level before using it the first time. Then
repeat calibration when travelling or if you suspect the measurement results to
be inaccurate. This step is necessary to adapt to local changes in the
gravitational field.
To access the calibration mode enter the MENU-function and choose item
number 5 “spirit level calibration”. Press either KEY #2 (PLUS-key) or KEY #3
(MINUS-key) and you will hear the announcement “calibration, step one: hold
the Tape King on an even surface and press KEY #1”. Follow the instructions
and place Tape King on an even surface and press KEY #1. Then Tape King
announces “calibration, step two: rotate the device 180° degrees and press
again KEY #1”. Now rotate the device by 180° degrees and press KEY #1. Tape
King then announces “calibration finished”.
Now the calibration of Tape King’s clinometer and spirit level is finished.
4.8 HISTORY OF LAST 10 MEASUREMENTS
Within the voice MENU function 6 “history of measurements” you can display
and hear the last 10 measurements which have been saved. To store a
measurement, press KEY #1 (ON/OFF-key) immediately after measuring.
To retrieve the last 10 stored measurements, enter the MENU with KEY #4
(MENU-key) and choose function 6 “history of measurements”. Browse the
measurements either with KEY #2 (PLUS-key) or KEY #3 (MINUS-key). If there
are no measurements stored you will hear an error signal.
Caution: Do not forget to press KEY #1 (ON/OFF-Key) after
the measurement. Otherwise this measurement will not be
saved in history and cannot be accessed anymore.

10
IMPORTANT NOTE: The history of measurements gets deleted when you turn
off Tape King.
4.9 BATTERY LEVEL
To hear the current battery level enter the voice MENU with KEY #4 (MENU-
key) and choose function 7 “battery level”. Tape King will announce its battery
status for example: “Battery level is on 95%”.
4.10 CHOOSE LANGUAGE (ONLY MULTILINGUAL-EDITION)
To choose a different language enter the MENU with KEY #4 (MENU-key) and
choose “8. language”. To browse the different languages –and to choose a
specific language use either KEY #2 (PLUS-key) or KEY #3 (MINUS-key). This
function is accessible only with Tape King Multi-Lingual-Edition.
5. VOICE MENU FUNCTIONS
By shortly pressing KEY #4 (MENU-key) you will enter the voice menu. Press
KEY #4 repeatedly to step through the menu. To toggle between settings within
a particular menu function use KEY #3 (MINUS-key) and KEY #2 (PLUS-key).
The menu functions are as follows:
1. spirit level / clinometer
2. measurements with / without case
3. volume level from 1 to 10
4. unit of measurement: metric / imperial system
5. spirit level calibration
6. history of measurements
7. battery level
8. language (only Tape King with Multilingual-Edition)
6. FUNCTIONS OF THE KEYS

11
7. SHORTCUT KEY COMBINATIONS
The most often used functions can be accessed via key shortcuts which are
described in the table below:
KEY
Action
Function
KEY #1: ON/OFF
(left round key)
Short press
Announcing measurement value
Long press
Power On / Off
KEY #2: PLUS
(left oval key; marked with
tactile dot)
Short press
Add measurement to memory
Long press
Recall memory
KEY # 3: MINUS
(right oval key; marked with
two tactile dots)
Short press
Retain/Release current value
Long press
Delete memory
KEY #4: MENU
(right square key, marked
with five tactile dots)
Short press
Menu
Long press
Clinometer and spirit level function
Shortcuts
(press simultaneously)
press
(short/long)
function
MENU-key
PLUS-key
SHORT
Increase volume
MENU-key
MINUS-key
SHORT
Decrease volume
MENU-key
ON/OFF-key
SHORT
Switch between with /
without case
PLUS-key
MINUS-key
SHORT
Switch between metric /
imperial
PLUS-key
MINUS-key
LONG
Switch between unit of
measurement

12
8. SAFETY INSTRUCTIONS
Only for non-commercial, indoor use.
Do not expose the device to extreme humidity or liquids.
Do not use when device is damaged or does not function normally.
Do not use Tape King at extreme temperatures. Safe and accurate
operation is warranted at temperatures between 32 °F and 104 °F
(0 °C and 40 °C).
Remove batteries when storing the device for a longer period of time to
avoid damage from leaking batteries.
Keep out of reach of children! Tape King is not a toy.
9. TROUBLE-SHOOTING
Tape King alerts you with the sound of an emergency siren to the fact that
the batteries are almost empty. You should change the batteries as soon
as possible. When changing the batteries the retained measurement value
gets lost but all values stored in memory remain intact.
If you do not hear Tape King speaking after you have replaced the
batteries with new ones and turned the device on, please, check the
polarity of the inserted batteries (see chapter 3 power supply).
If the tape has been pulled out a lot like 5 ft. (1.5 m) or more, it may retract
slowly. You can easily speed it up by slightly tilting the duct tape towards
the floor while continuing to retract the tape.
10.CLEANING
Only use a soft cloth slightly moistened with water or rubbing alcohol to clean
Tape King’s surface! Avoid strong acid or scrubbing cleansers. Do not scrub the
surface with sharp objects or rough sponges, as it could damage the case of the
device.

13
11. TECHNICAL DATA
12. GUARANTEE AND SERVICE
Warranty periods from date of purchase:
Twenty-four (24) month on the device itself
Twelve (12) months on the accessories (e.g. power supply, batteries,
earphones, etc.)
Six (6) months on wear parts (e.g. battery, case, etc.)
For storage devices (CDs, SD cards, etc) as well as for batteries no
guarantee is provided
Measuring units:
Metric system
Imperial system
Measuring
accuracy:
Class II
Tolerance between measured and announced value up
to 2 mm (~0,08”)
Measuring length:
up to 196.85 inches, 16.4 feet, 5 meter
Power supply:
2 x 1,5 V Alkali batteries or rechargeable batteries,
Type AAA, LR03 Micro
Dimensions:
4.1 x 3.0 x 1.3 inches (103 x 75 x 33 mm)
Weight:
10.4 oz (295 g) (incl. batteries)
Storage
temperature:
14 °F to 122 °F (-10 °C to +50 °C)
Operating
temperature:
32 °F to 104 °F (0 °C to +40 °C)
Included in box:
Tape King, alkali batteries, pouch, instruction manual

14
During the warranty periods mentioned above, the product will be either
repaired or replaced free of charge. In no event shall CareTec be liable
for indirect, special or consequential damages. The exposure of the
device to liquids, strong electromagnetic fields, heat as well as dropping
the device or opening the case causes immediate loss of guarantee. In
case of problems please contact CareTec or your local distributor before
returning the device without any apparent reason. We will then inform
you about the necessary procedures. The device may only be opened
by authorized personnel!
CareTec reserves the right to make any changes or improvements to its
products without further notice.
13. LEGAL NOTICE ON THE DISPOSAL OF ELECTRONIC DEVICES
13.1 DISPOSAL OF USED ELECTRONIC DEVICES
13.2 BATTERY DISPOSAL
This product must be disposed of separately from household
waste at specially designated collection and recycling points. For
further information please contact your local authorities.
Batteries must not be disposed together with household waste.
As a consumer you are legally obligated to bring your old
batteries to public collecting points (in your community or any
shop that provides these batteries).

15
The following sign indicates contamination of the batteries: "Pb-Cd-Hg"
Pb = containing lead
Cd = containing cadmium
Hg = containing mercury
14. SYMBOLS USED
15. MANUFACTURER
Tape King EN V1.7 10/2015
Caution
Dispose of separately from household waste
Manufacturer
CareTec International GmbH
Stubenbastei 1
A 1010 Vienna, Austria
Is the manufacturer of this product.
Phone: (+43 1) 513 80 81 0
Fax: (+43 1) 513 80 81 9
Email: of[email protected]
Web: www.caretec.at

16
Table of contents
Other Caretec Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

PITSID
PITSID NIP CON SMART compact Operation manual

Benetech
Benetech GM3120 instruction manual

TESA
TESA TESATRONIC TT20 instruction manual

Anapol
Anapol EU-50 Operating Instructions and Equipment Description

Hanna Instruments
Hanna Instruments HI 9812-0 instruction manual

PCB Piezotronics
PCB Piezotronics 339A31 Installation and operating manual