manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CarlStahl
  6. •
  7. Power Supply
  8. •
  9. CarlStahl XLED-PS-9 User manual

CarlStahl XLED-PS-9 User manual

TECHNICAL SUMMARY
XLED-PS-9 / XLED-PS-9-C
www.x-led.de
v.08.2021
X-LED Power Supply
XLED-PS-9 / XED-PS-9-C
2www.x-led.de
www.x-led.de // +49 7162- 948150-300 // [email protected]
LUNA-RJ (X-LED version)
The MADRIX LUNA-RJ reliably distributes DMX512 data over long or short distances using Ethernet network or USB.
Its sync mode makes sure that lighting effects look their best on the LEDs.
Art-Net / Streaming ACN / USB:
Art-Net or Streaming ACN data is directly converted to DMX512.
Optimize and decentralize cabling to cover any distance to the device using Ethernet network.
Any small or large project greatly benefits from dependable data distribution and efficient operation.
Use any compatible software or hardware controller. In addition, simply connect to MADRIX 5 over USB.
3 DMX-OUT:
3 RJ45 ports (female) distribute the equal number of DMX universes per unit.
Simply use several units at the same time for larger projects.
Sync Mode:
MADRIX 5 and MADRIX hardware allow you to synchronize Art-Net data for all output ports and even across multiple devices
to get an optimal image on the LEDs without visual interruptions.
Easy Configuration:
MADRIX LUNA-RJ offers powerful features, especially in combination with MADRIX 5.
Take full advantage of pixel mapping and voxel mapping. The installation of the device is still quick and easy.
3rd-Party Controllers:
MADRIX LUNA-RJ complies with the official protocol specifications and can be used as a regular node with your other consoles,
controllers, or software solutions.
Quality Design:
They feature a fanless, noiseless, low-energy design, in our metal case. 4 indicators quickly show the status of a device.
Special Notes:
The device is ready within seconds after startup. HTP merging is automatically available for two Ethernet sources.
Firmware is upgradable for future enhancements.
Access and change the specific device settings using the built-in web configuration page.
Bandwidth:
As a receiving unit, the 100 MBit/s RJ45 Ethernet connection is more than enough.
For large projects we recommend to use Art-Net and 1 GBit/s for the network switch and network card.
For the sender of all the data, the higher bandwidth is required.
Art-Net data is normally sent in broadcast mode where all receivers get all the data, however
with MADRIX 5, we also support unicast with the Direct IP mode to just sent the required data to each single unit.
In all cases, MADRIX LUNA provides the performance you need.
3
[email protected] // +49 7162- 948150-300 // www.x-led.de
X-LED Power supply
XLED-PS-9 / XED-PS-9-C
Switch / Hub
XLED-PS / XLED-PS-C
Power supply, incl. LUNA-RJ
for max. 9 LED-LINES,
max. 56 Dots per LINE,
XLED-PS / XLED-PS-C
Power supply, incl. LUNA Controller
for max. 9 LED-LINES,
max. 56 Dots per LINE,
........
XLED-PS / XLED-PS-C
Power supply, incl. LUNA-RJ
for max. 9 LED-LINES,
max. 56 Dots per LINE,
Input device
(Media - PC)
Datacable (RJ45)
* LED Line configuration, please see X-LED LINE - Technical summary.
* 20m - 60m
* 20m - 60m
* 20m - 60m
X-LED Power Supply
XLED-PS-9 / XED-PS-9-C
4www.x-led.de
www.x-led.de // +49 7162- 948150-300 // [email protected]
Software
Stand-alone playback unit
Stand-Alone Playback:
Independently run the most sophisticated light shows from this energy-efficient playback unit via Art-Net or Streaming ACN.
Easily control up to 8 or 32 universes per device.
Live Recording:
Record any Art-Net or Streaming ACN network stream onto the inserted memory card.
Unlike any other solution, recording a beautiful light show with MADRIX 5 is as easy as pressing record and play.
Central Hub:
Simply connect compatible MADRIX hardware interfaces or third-party nodes to provide the correct output for your lighting fixtures.
Time-Controlled Shows:
Run scenes automatically with the help of the internal clock as well as the available sunrise and sunset timers.
Master-Slave Synchronization & Scalability:
Manage large projects simply by connecting several units.
The entire group is automatically synchronized across all DMX universes for flawless and uninterrupted playback.
Web Configuration:
Use the built-in web configuration page to access and change specific device settings,
such as the important IP address, subnet mask, playlist settings, and much more.
Live Control:
Encased in a non-conductive design for DIN rails or wall mounting, 8 on-device buttons allow for quick playback and recording control.
You can also directly adjust the overall speed and intensity.
Remote Control:
Trigger MADRIX AURA via HTTP commands and the built-in web server or use Art-Net/sACN.
You can even add MADRIX ORION for interactive installations.
5
[email protected] // +49 7162- 948150-300 // www.x-led.de
X-LED Power supply
XLED-PS-9 / XED-PS-9-C
Switch / Hub
Datacable (RJ45)
XLED-PS / XLED-PS-C
Power supply, incl. LUNA-RJ
for max. 9 LED-LINES,
max. 56 Dots per LINE,
XLED-PS / XLED-PS-C
Power supply, incl. LUNA Controller
for max. 9 LED-LINES,
max. 56 Dots per LINE,
........
XLED-PS / XLED-PS-C
Power supply, incl. LUNA-RJ
for max. 9 LED-LINES,
max. 56 Dots per LINE,
Stand-Alone Playback:
Independently run the most sophisticated light
shows from this energy-efficient playback unit
via Art-Net or Streaming ACN.
Easily control up to 8 or 32 universes per device.
Stand-alone
* 20m - 60m
* 20m - 60m
* 20m - 60m
* LED Line configuration, please see X-LED LINE - Technical summary.
X-LED Power Supply
XLED-PS-9 / XED-PS-9-C
6www.x-led.de
www.x-led.de // +49 7162- 948150-300 // [email protected]
Connector groups
Connector secondary
Fuses
Voltage range
Rated power
Rated current
Frequency
PF
Voltage adj. range
Current adj. range
Inrush current
Operating temperature
Protection level
Size
Network connection
Control
Housing
Operating features
Mounting options
3 x 3 groups
max. 56 Dots per group
5 fuses (per DMX-splitter)
90 - 305 VAC (L/N/PE max. 4mm² )
127 - 431 VDC (L/N/PE max. 4mm² )
3x 300 Watt
3x 15 A
50-60 Hz
> 0,94
17 VDC - 22 VDC (per DMX-splitter / Group)
7.5 A - 15 A (per DMX-splitter / Group)
COLD START 3x 70 A at 230 VAC
-20°C to +50°C
IP65 - outdoor rated
W: 490mm (465mm) D: 300mm H: 127mm
Art-Net
3 x DMX512A
Aluminum, black or grey powder coated
Power In
Wall mounting, horizontal, vertical, L-profil
300mm 465mm
490mm
125mm
57mm
335mm
7
[email protected] // +49 7162- 948150-300 // www.x-led.de
X-LED Power supply
XLED-PS-9 / XED-PS-9-C
XLED-PS / XLED-PS-C
Power supply, incl. STELLA
for max. 6 LED-LINES,
max. 56 Dots per LINE,
XLED-PS / XLED-PS-C
Power supply, incl. LUNA Controller
for max. 9 LED-LINES,
max. 56 Dots per LINE,
XLED-PS / XLED-PS-C
Power supply, incl. STELLA
for max. 6 LED-LINES,
max. 56 Dots per LINE,
........
XLED-PS / XLED-PS-C
Power supply, incl. STELLA
for max. 6 LED-LINES,
max. 56 Dots per LINE,
XLED-PS / XLED-PS-C
Power supply, incl. LUNA Controller
for max. 9 LED-LINES,
max. 56 Dots per LINE,
XLED-PS / XLED-PS-C
Power supply, incl. STELLA
for max. 6 LED-LINES,
max. 56 Dots per LINE,
up to 3x power supplies
Electrification
next 3 PSUs
min. 1.5mm²
min. 1.5mm²
X-LED Power Supply
XLED-PS-9 / XED-PS-9-C
8www.x-led.de
www.x-led.de // +49 7162- 948150-300 // [email protected]
LED-Lines LED-Lines Power In/Out
Data In
(RJ45)
USB
- GND
AADR
+ VDC
Data +
Data -
9
[email protected] // +49 7162- 948150-300 // www.x-led.de
X-LED Power supply
XLED-PS-9 / XED-PS-9-C
Wiring
1
2
3
4
5
+12VDC
Data +
Data -
GND
AADR
( marked in white )
X-LED Power Supply
XLED-PS-9 / XED-PS-9-C
10 www.x-led.de
www.x-led.de // +49 7162- 948150-300 // [email protected]
Our devices are certifi ed according to the following European and American Standards
CONFORMITY
NOTE:
This equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of these equipment in a residental area is likely
to cause harmful interference in which case the user will be required to correct the interference at his own expense.
„This Class (A) digital apparatus complies with Canadian ICES-003”
COPYRIGHT:
©Carl Stahl ARC GmbH. All rights reserved.
Specifications are subject to change without notice.
No representation or warranty as to the accuracy or completeness of the information included herein is given
and any liability for any action in reliance thereon is disclaimed.
All trademarks are owned by Carl Stahl ARC GmbH or their respectives owners.
Warranty:
We provide for our LED-Dots ( XLED-DOT-...-...) and power supply units ( XLED-PS-...) a warranty of 5 years.
Within the warranty period a failure rate of 3 % could occur. This failure rate is no claim for warranty.
We advise to order a corresponding number of spare parts. For professional replacement we provide a training by our specialists.
Requirement for our warranty is the compliance with our installation and maintenance guidlines.
Due to side and application conditions problems can occur, which are not covered by the warranty, except they where named specifically
by the client in advance. The installation has to be made by trained and skilled workers.
Clean device from dirt and residue regularly. Use solvent-free cleaning agents only and do not employ aggressive chemicals or high pressure‚
cleaner. Operate device only after complete drying.
SERVICING AND MAINTENANCE
Please check all trouble-shooting measures given in this operating manual.
For any further questions please contact our hotline.
Tel: +49 (0) 7162/948 150 300 | Fax: +49 (0) 7162/948 150 305
CUSTOMER SERVICE
CARL STAHL ARC GMBH
Siemensstraße 2
D-73079 Süssen
Fon +49 (0) 7162 / 948 150 300
Fax +49 (0) 7162 / 948 150 305
[email protected]
www.x-led.de

This manual suits for next models

1

Other CarlStahl Power Supply manuals

CarlStahl XLED-PS-6 User manual

CarlStahl

CarlStahl XLED-PS-6 User manual

CarlStahl X-LED-PS-6-C Manual

CarlStahl

CarlStahl X-LED-PS-6-C Manual

Popular Power Supply manuals by other brands

urmet domus IPerVoice 1039 manual

urmet domus

urmet domus IPerVoice 1039 manual

M-system M5DY instruction manual

M-system

M-system M5DY instruction manual

AMX PSN2.8 Specifications

AMX

AMX PSN2.8 Specifications

Extron electronics PS 1230 installation guide

Extron electronics

Extron electronics PS 1230 installation guide

H3C RPS500-A3 user manual

H3C

H3C RPS500-A3 user manual

Medistrom Pilot-12 Lite product manual

Medistrom

Medistrom Pilot-12 Lite product manual

VOLTEQ HY10500EX user manual

VOLTEQ

VOLTEQ HY10500EX user manual

BEL LDN240 Series installation instructions

BEL

BEL LDN240 Series installation instructions

Valcom VP-6124 user guide

Valcom

Valcom VP-6124 user guide

Lütze CPSB1-120-24 E instructions

Lütze

Lütze CPSB1-120-24 E instructions

Puls FIEPOS FPS300.246-049-102 instruction manual

Puls

Puls FIEPOS FPS300.246-049-102 instruction manual

Magnetek PS-A10H installation manual

Magnetek

Magnetek PS-A10H installation manual

Danfoss AK-PS150 Instructions for use

Danfoss

Danfoss AK-PS150 Instructions for use

Hantek HT3003PE instruction manual

Hantek

Hantek HT3003PE instruction manual

Philips LightLine 872790085234900 Brochure & specs

Philips

Philips LightLine 872790085234900 Brochure & specs

Farnell L30A Instruction book

Farnell

Farnell L30A Instruction book

Power XXL A Series instruction manual

Power

Power XXL A Series instruction manual

NETGEAR APS150W installation guide

NETGEAR

NETGEAR APS150W installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.