10 From the local console or from a remote session such as a PuTTY session over Telnet or
SSH to the default IP address 192.168.2.100 of the 10/100 Ethernet port (eth 0), perform the
following tasks:
1. Login to the CLI using the root login and the casa password.
2. Enable the CMTS privileged mode to configure the CMTS.
running configuration. The default password is casa.
3. Display the CMTS software version.
4. Enable configuration mode.
5. Change the default IP address of the CMTS management port. See the example IP address below.
.
CASA-CMTS login> root
Password: casa
CASA-CMTS> enable
Password: casa
CASA-CMTS# show version
Running Image: SMM Rel 5.4, Ver 21, build 12, Tue Mar 29 09:21:33 EST 2011,(mlin)
Configured boot device: net
Target IP: 192.168.2.100, Host IP: 192.168.2.100
Boot Image: casa_6000.gz.rel5.4.21.build12
CASA-CMTS# config
CASA-CMTS(config)# interface eth 0
CASA-CMTS(config-if-eth 0)# ip address 135.2.0.0 255.255.255.0
11
Configure the CMTS software, interfaces, routing protocols, BPI,
load balancing, spectrum management, modulation profiles, etc.
Refer to the following documents, available as downloads
in PDF format from the Casa FTP site.
Casa Systems -- CMTS Release Notes
Casa Systems -- C2200 CMTS Hardware Installation Guide
Casa Systems -- CMTS Software Configuration Guide
Casa Systems -- CMTS Debugging and Diagnostics Reference
Casa Systems -- CMTS Network Solutions Guide
C
A S A
CASA
CASA SYSTEMSCASA SYSTEMS
C2200C2200
S
Y
S
S
T
A
T
M1
M2
M3
M4
G1
G2
G3
G4
BITS RED 10/100 G1 G2 G3 G4
DB-9F to DB-9F
null modem/console cable
Connect PC or terminal to SMM for local setup.
Console settings:
115200 bps
8 data bits
No parity
1 stop bit
No flow control
onso
e settings
15200 bps
8 data bit
No par
t
sto
bit
No
low contro
7Connect RF I/O cables up to upstream and
downstream ports. Tighten F-connectors
to 15 inch-lbs of torque.
DQM QAM
downstream
RF output
DCU
upstream
RF input
C2200 CMTS Quick Installation (cont.)
9
Connect AC or DC power cabling. See the Hardware Installation Guide
for information on power sources and redundancy requirements.
Apply system power when ready. Turn on local console to confirm
successful. system bootup. The CASA-CMTS# prompt will display on
console. Check LEDs for operational status.
l
0
AC power supply
AC power cord
to power source
0l
FUSE
B
A
A
L
M
AB
-48A RTN -48B RTN
(-) (+) (-) (+)
-48A RTN -48B RTN
(-) (+) (-) (+)
OUT (-) GND OUT (+)
Representative DC power
source connection points
AWG 12
DC power supply