When in the SETUP MODE, pressing the “MAN”
(Manual) button steps up thru the entire list of
parameters. The pattern of the top six LEDs, LEDs
Bank 1 is used to indicate which parameter is
selected. The pattern will change once each time
the “MAN” button is pressed.
Pressing the “OFF” button steps up thru all the
available values for each parameter. The pattern
of the bottom five LEDs, LEDs Bank 2 is used to
indicate which value is selected. The pattern will
change once each time the OFF button is pushed.
Pressing the “AUTO” button stores the
displayed value.
LEDs Bank 1
LEDs Bank 2
Setting Up the Cascade
To enter the SETUP Mode, first remove DC power to the Cascade controller for approximately 10 seconds.
On the back of the controller are four DIP switches, set switch #1 to ON (see schematic at right) then restore DC power.
The AUTO mode LED will blink to indicate that the Cascade is in the SETUP MODE.
If any value is changed, it will blink until stored, except a value of zero. If any value is changed but not stored, and the parameter is changed, the value will still be
what was shown originally.
If you accidentally go past a desired parameter or value, you can step back by pressing the down arrow button.
The complete parameter/value list and corresponding LED indication are shown on Table 1 –Parameter Values and Corresponding LED indication. (see pages 15-
18 of the Installation and Operations Manual) via the following link; Product Information (enovationcontrols.com).
When you are finished with setup, set switch #1 to the Normal Operating Position (OPEN) remove DC power for 10 seconds, then restore DC power.