
1 2 3 4 5 6
7 8 9 10 11 12
1. Typical DIP Switches Setting
To access switches open the back lid. Switches are located on the right side of
the lid, as observed from the bezel. The “up” state is defined as the switch
position closer to the top cover of the lid.
1-st Bill Enable controlled by host
2-nd Bill Enable controlled by host
3-rd Bill Enable controlled by host
4-th Bill Enable controlled by host
5-th Bill Enable controlled by host
6-th Bill Enable controlled by host
7-th Bill Enable controlled by host
8-th Bill Enable controlled by host
2. Interface Connector Pinout
Mating Connector:
Socket 43025-1200 (Molex);
Contact 43030-0002 (Molex).
3. Power connections
+12 V lines must be connected together directly at the connector.
Power ground lines must be connected together directly at the connector,
thus forming a power ground star point; 12V power source must use this star
point.
Signal ground may not be connected to power ground star point; it should be
connected to the host signal ground instead.
Bus reset line, host Rx and Tx lines are all RS232 signal level lines.
4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
Boot-related flashes (green flashes on red background)
Memory write error –check memory stick for proper contact
Firmware set incomplete –please obtain the missing part and
install
A required card is missing –please install the card required;
normally reported when the main firmware component is
missing/corrupt
Update policy violation –please install the card required to
regain policy rights; most common reason –a ONE UPDATE
or NDEG card is missing
Generic error –a fatal boot error, please contact technical
support
Operation flashes (red flashes on dark background)
Box removed –please verify the drop box is secured in place
Boot invocation error –please verify that a required card is in
place
Box full –check the drop box and make sure it’s not full
Stacker plate stuck –verify that drop box is fully inserted and
stacker plate has room to move inside the drop box
Optical sensor failure –contact technical support
Magnetic sensor failure –contact technical support
Bill jam –please verify the bill pathway is clear
Firmware integrity problem –please verify that all firmware
components are installed