Celsicom T603 User manual

User manual
TC603
Quick Guide
Register as a customer and create an account for the Celsiview cloud service
At the moment, the Celsiview cloud service, version two, can be tested, it can be accessed by click-
ing on the ”Celsiview 2 Beta” button on celsiview.se. The registration of accounts and sensors is
now done in Celsiview version 2.
Click on the ”Create new account” button. Fill in all the information needed to create the account.
A verication email will then be sent to the email address provided in the registration process.
Click on the link in the email to verify the account. If you do not receive an email, please check the
spam mail. Once the account is veried, a page will appear with a link to the login page.
Adding the sensor to your sensor registry
Go to the Celsiview 2 login page by clicking on ”Celsiview 2 Beta” on celsiview.se and log in. Select
”Sensor” from the menu and then ”Add new sensor”. Now scan a sensor or enter the data manual-
ly (S/N + control code written on the sensor). After the sensor data is displayed, click on ”Add this
sensor”. The cost of the sensor is now presented. NOTE! Activate also the concrete strength calcu-
lation function if it is to be used. Accept by adding the sensor to the shopping cart. Now scan the
remaining sensors in the same way.
Click on the shopping basket and view the contents. A summary of the costs is now displayed. Se-
lect or create an invoice recipient. The invoice recipient should contain all the information needed
to be accepted by your nance department. The references, cost centre, etc. will appear on your
invoice. Click on ”Complete transaction!” to activate the sensor.
Start and activate the sensor(s)
Open the lid of the sensor via the buckle on one side. Pull the entire front panel upwards/
outwards out of the yellow box by holding some of the four pole screws.
Connect 2 alkaline AA/LR6 batteries (1.5V) to the battery holder. The sensor will now beep to
indicate that it is booting up and an orange LED on the circuit board will light up. Both the orange
and green LEDs light up shortly thereafter in a constant light while the sensor is searching for a
mobile connection. The connection to the mobile network may take several minutes.
When the sensor is properly connected, the orange LED goes out and the green LED starts ashing
and three short beeps are heard. The green LED now ashes the mobile signal strength every 30
seconds for 15 minutes. 3 blink=high level, 2=medium and 1=low. Feel free to move the transducer
to achieve the best possible strength. A better signal strength gives a longer battery life.
For 45 minutes, the sensor will now send data every 3 minutes. After a total of 60 minutes, the
sensor will switch to transmitting less frequently to save battery power. To restart the above pro-
cess press the ”Install mode” button on the front panel.

Start a concrete measurement
If you already have a TC603 concrete sensor and want to use your new sensor together with the
other sensors, you can use Celsiview version 1 as before. This is to be able to work with all your
sensors together in different castings. If the new sensor(s) will be used completely separately
from your already purchased and activated sensors, Celsiview version 2 should be used, this way
you will have access to the very latest features. Eventually, version 1 will also be discontinued
and no longer available for use. Below is a description for Celsiview version 1 and one for ver-
sion 2. Follow the instructions that best suit your way of working.
Main use of Celsiview version 1
Go to celsiview.se and click on ”Celsiview 2 Beta” and log in. Click on ”Sensors” in the menu, you
will now see the sensors that were activated in the previous steps of this manual. Click on the
plus sign (Create measurement locations for all channels of the sensor) at the far right of the
line for the sensor to be used. A suggested name for the measurement locations is now presen-
ted. Change the name if necessary, e.g. ”Box 01” or similar. Click on ”OK”. Measurement locations
have now been created for that sensor. Now log in to version 1 of Celsiview on celsiview.se and
work with casts/locations as before.
Main use in Celsiview version 2
Click on ”Concrete” and ”Jobs” in the menu. Then click on ”+ New job”. Enter a name for the cas-
ting. Set the start and stop time of the casting (can be adjusted afterwards if needed). Select the
concrete recipe and strength class.
Click on ”Create a cast job (simplied mode)”
A list of selectable registered sensors with their technical data is now displayed. Click on the
sensor/box to be used for the casting. It is also possible to search for a sensor in the list, e.g. by
serial number or name/alias if specied. Click on ”OK”.
A yellow TC603 box has three channels. Channels 1 and 2 (marked on the front of the box) are
for thermocouple wire and measurement of temperature and strength of the concrete. Channel 3
is for measuring ambient air temperature and its sensor is located inside the TC603.
The rst selection now displayed is for channel 1. Click on ”Add this channel to my measurement”
if it is to be used in the casting. Enter a name for the channel, e.g. its location in the casting or
similar. In the next step, the same applies to channel 2. If it is not to be used, click on ”Skip this
channel”. The last step is for channel 3, ambient air temperature.
The casting is now saved and the measurement starts at the designated start time. In the other
settings on the page, e.g. low temperature alarm (frost warning) and message about certain
achieved strength can now be entered. Click on ”Save casting”.
Reports, settings and favourites
In the menu ”Concrete” > ”Jobs”, all castings projects are now listed. Three icons on the right of
each line are shortcuts to all the items for that casting. The choices are for settings, reports and
making a casting a favorite which then appears on the ”Home” page. The menu choices are also
accessible by clicking on a row for a casting when a quick selection box appears.

My business
When a new casting is saved, it appears in ”My business”. A group/folder is automatically created
for each casting, with the same name as the casting name. The folder contains the measure-
ment locations/values that were created when the casting was saved. The name of the folder
can be changed by right-clicking on it and selecting ”Change name”.
A casting/folder/group can also be shared with someone else. Right-click on the folder and
select ”Share”. Select a recipient or create a new one. Create a new user by entering the email
address of that person (which will also be the username when logging into the cloud service).
Do not remove any ticks from the checkboxes, both should be selected. Click on ”OK”. Now select
the new recipient from the list. Also select the rights of the user. Read/View cannot change
anything among the settings, only view reports. An Administrator has full rights. The new user
will now receive an e-mail for password selection and can then log in with their details.
Other information
Support
All support is handled by our distributors. See celsicom.se for more information. User manuals
and other support material are available at support.celsicom.se.
Working with thermocouple wire
Important! Twist the wires together at the end of the measurement (approx. 10 mm) using a
pair of pliers for to get proper galvanic contact. Twisting only with nger force is usually not
sufcient for a stable contact. Poor contact will result in unusable measurement data.
Contact your distributor for suitable
thermocouple wire. A thinner wire
is preferable since it takes up
less space through the box
rubber strip in the lid.

User manual
T603
Celsicom AB
Härdgatan 28 A, 432 32 Varberg
SVERIGE
celsicom.se
support.celsicom.se
Version of user manual: 11 Made in Sweden
Model Measured value Range Maximal
avvikelse
Certicate
TC603 3 x temperatur=
2 x thermocouple
1 x internal sensor
Depending on ther-
mocouple type**
Thermocouple
±0.5°C *
Internal sensor
±0,5°C
CE
Connection NB-IoT (LTE Cat NB1) B20. Power 23 dBm
Batteries 2 x AA/LR6 1,5V (included)
Battery time Depending on the transmission interval. Example at 20°C, good signal
quality, measurement every 5 minutes and transmission every 3 hours: > 12
months
Measurement and transmissi-
on interval
Adjustable by users via the Celsiview cloud service.
Memory 200 measurements
Size Enclosure 125 (b) x 200 (h) x 75 (d) mm
Weight 620 grams (incl. batteries)
Certicate CE
Mounting method Mounted with the mounting hook facing upwards
*/ Accuracy instrument, without transducer.
**/ The sensor is switchable between different types of thermocouples. Type T is standard.
This manual suits for next models
1
Table of contents
Other Celsicom Accessories manuals
Popular Accessories manuals by other brands

ORION TELESCOPES & BINOCULARS
ORION TELESCOPES & BINOCULARS EZ Finder II instruction manual

BIOS LIVING
BIOS LIVING 57106 instruction manual

iOptron
iOptron SmartEQ Pro Plus instruction manual

SmartLabs
SmartLabs TriggerLinc 2421 quick start guide

Safety Technology International
Safety Technology International STI-33010 Instruction guide

Datalogic
Datalogic SG-LP SERIES manual