manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Center
  6. •
  7. Control Panel
  8. •
  9. Center EHE0200160 User manual

Center EHE0200160 User manual

42009085-013 R1
The Programmer should be mounted at a level where the
display can be seen clearly and the ambient temperature is
within the range of 0 to 45°C. The unit is for use in normal
domestic environments.
To remove the unit from the
wallplate, slacken the two securing
screws and hinge the unit up to
separate the two halves.
CAUTION: Isolate power supply and
make safe before wiring the unit to
prevent electric shock and equipment
damage. Installation should be
carried out by a qualified electrician
or competent heating engineer.
Installation Guide
for EHE0200160 Programmer
Introduction
EHE0200160 is an Electronic Full Programmer providing accurate
time control for central heating installations with separate
programmes for heating and hot water. It can be used to
program a heating schedule for weekdays (Monday – Friday) and
weekends (Saturday and Sunday) independently.
Specification
Power Supply : 230V~, 50…60Hz, 8VA
Switch Action : 2 x SPDT
Switch Rating : 230V~, 50…60Hz, 3(3)A
Timing Accuracy : ±1min./month
Power Reserve : typically 4 days
Approvals : CE marked
Mounting
Mounting Options
Heating
Hot Water
ON
-
OFF
OVERRIDE EXTRA HOUR
Mon Tue Wed Thu Fri Sat Sun
ON
-
OFF ON
-
OFF
RECOMMENDED CLEARANCE DISTANCES:
ABOVE WALLPLATE: 40mm
BELOW WALLPLATE: 100mm
LEFT/RIGHT OF WALLPLATE: 10mm
b. Flush switchbox Fixing
holes are spaced to suit
BS4662 requirements
c. Surface mounting with
surface wiring in
mini trunking
a. Surface mounting
concealed wiring
Wiring
A switch, having contact separation of at least 3mm in all poles
(formerly Class ‘A’), must be incorporated in the fixed wiring as
a means of disconnecting the supply.
The unit is a Class II (double insulated) device. An earth
terminal is provided for external earth continuity.
The system must be appropriately fused. A fuse rated at no
more than 3 Amps should be installed.
The unit has 4 knockouts for surface wiring, care must be taken
to ensure that the cable or mini-trunking completely fills the
knockout hole without leaving any gaps.
ALL WIRING MUST BE IN ACCORDANCE WITH I.E.E.
REGULATIONS. THIS UNIT IS FOR FIXED WIRING ONLY.
Replacing Other Manufacturers’ Time Controls
This Programmer will mount directly onto many existing
manufacturers’ back-plates, without the need for re-wiring.
However, it is also supplied complete with a wiring
back-plate, should this not be the case.
Wiring Connections for EHE0200160 Programmer
Internal Wiring Notes
1. The Programmer is a Class II (double insulated) device. An earth parking
terminal is provided for earth wiring continuity, if required.
2. In the SUNDIAL S, W, and Y Plan wiring diagrams, connections are shown to
basic boilers only. For wiring connections to Pump over-run boilers refer to
Boiler manufacturers’ instructions.
3.
The Programmer is not suitable for basic gravity hot water control, unless using
a C-Plan, because it incorporates independent heating and hot water switching.
Final Assembly
Clip the unit onto the hinges on the top of the wallplate and
hinge down into position. Tighten the two securing screws
using a screwdriver.
Switch on the power – the Programmer will now be operating
according to the built-in programme. Refer to “USER GUIDE”
for programming details.
If the display remains blank press the RESET button, located
under the controls cover, with a blunt instrument (e.g. Pencil)
Y-Plan
C-Plan
S-Plan
W-Plan
ROOM STAT
2 3 1
CYL. STAT
2 1
C
MID-POSITION VALVE
BLUE
G/YELLOW
WHITE
GREY
ORANGE
3 AMPS
MAX
L
N
230V~
50...60Hz
BOILER
PUMP
E N L
L
N
E
EHE0200160
*NOTE 1
N
L 1 2 3 4
1 2 3 4 5 6 7 8 9 10
ROOM STAT
2 3 1
CYL. STAT
2 1
C
2 PORT ZONE VALVE
HEATING
BLUE
G/YELLOW
BROWN
ORANGE
GREY
2 PORT ZONE VALVE
HOT WATER
BLUE
G/YELLOW
BROWN
ORANGE
GREY
3 AMPS
MAX
L
N
230V~
50...60Hz
BOILER
PUMP
E N L
L
N
E
EHE0200160
*NOTE 1
12345678910
N
L1234
2 PORT ZONE VALVE
BLUE
G/YELLOW
BROWN
WHITE
ORANGE
GREY
3 AMPS
MAX
L
N
230V~
50...60Hz
BOILER
PUMP
E N L
L
N
E
EHE0200160
*NOTE 1
CYL. STAT
2 1
C
N
L 1 2 3 4
ROOM STAT
2 3 1
1 2 3 4 5 6 7 8 9 10
ROOM STAT
2 3 1
DIVERTING VALVE
G/YELLOW
BROWN
BLUE
CYL. STAT
2 1
C
3 AMPS
MAX
L
N
230V~
50...60Hz
BOILER
PUMP
E N L
L
N
E
EHE0200160
*NOTE 1
N
L 1 2 3 4
1 2 3 4 5 6 7 8 9 10
Clock
N L 1 2 3 4
3 AMPS MAX
HW OFF HW ON
CH OFF CH ON
N
L
OFF ON OFF ON
230V~
50...60Hz
EHE0200160
Timed Outputs
Whilst every care has been taken to ensure that the information included in this document
was accurate at the time of printing, we reserve the right to change specifications at any time.
The photographs reproduced in this publication are within the constraints of the printing
process and are NOT to be used for matching purposes. E&OE.
For further information telephone 0870 8506538
Ref:4277

Popular Control Panel manuals by other brands

Ampac ZoneSense Plus Operation & programming manual

Ampac

Ampac ZoneSense Plus Operation & programming manual

Microm FX-3500 Installation and operation manual

Microm

Microm FX-3500 Installation and operation manual

Honeywell Domonial CMI Series Installer manual

Honeywell

Honeywell Domonial CMI Series Installer manual

WURM FRIGOLINK 1 ANI-C quick start guide

WURM

WURM FRIGOLINK 1 ANI-C quick start guide

U-Prox IP100 Installation and programming manual

U-Prox

U-Prox IP100 Installation and programming manual

Sub-Zero CRC-2052 user manual

Sub-Zero

Sub-Zero CRC-2052 user manual

Siemens SINUMERIK ONE MCP 2400 Equipment manual

Siemens

Siemens SINUMERIK ONE MCP 2400 Equipment manual

AUTOTERM PU-27 Operation manual

AUTOTERM

AUTOTERM PU-27 Operation manual

Channel Safety Systems AlarmSense 2 ZONE manual

Channel Safety Systems

Channel Safety Systems AlarmSense 2 ZONE manual

LSIS iXP2 Series user manual

LSIS

LSIS iXP2 Series user manual

Divus Touchzone Series user manual

Divus

Divus Touchzone Series user manual

U-Prox MP LTE user manual

U-Prox

U-Prox MP LTE user manual

Siemens Series 2300 installation instructions

Siemens

Siemens Series 2300 installation instructions

FM Electronics FM4000X installation instructions

FM Electronics

FM Electronics FM4000X installation instructions

Garmin GPSMAP 12 3 Series owner's manual

Garmin

Garmin GPSMAP 12 3 Series owner's manual

GE IC754CSF15CTD Hardware user's guide

GE

GE IC754CSF15CTD Hardware user's guide

Galletti MCA 10 M manual

Galletti

Galletti MCA 10 M manual

DMP Electronics XR200 installation guide

DMP Electronics

DMP Electronics XR200 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.