42009085-013 R1
The Programmer should be mounted at a level where the
display can be seen clearly and the ambient temperature is
within the range of 0 to 45°C. The unit is for use in normal
domestic environments.
To remove the unit from the
wallplate, slacken the two securing
screws and hinge the unit up to
separate the two halves.
CAUTION: Isolate power supply and
make safe before wiring the unit to
prevent electric shock and equipment
damage. Installation should be
carried out by a qualified electrician
or competent heating engineer.
Installation Guide
for EHE0200160 Programmer
Introduction
EHE0200160 is an Electronic Full Programmer providing accurate
time control for central heating installations with separate
programmes for heating and hot water. It can be used to
program a heating schedule for weekdays (Monday – Friday) and
weekends (Saturday and Sunday) independently.
Specification
Power Supply : 230V~, 50…60Hz, 8VA
Switch Action : 2 x SPDT
Switch Rating : 230V~, 50…60Hz, 3(3)A
Timing Accuracy : ±1min./month
Power Reserve : typically 4 days
Approvals : CE marked
Mounting
Mounting Options
Heating
Hot Water
ON
-
OFF
OVERRIDE EXTRA HOUR
Mon Tue Wed Thu Fri Sat Sun
ON
-
OFF ON
-
OFF
RECOMMENDED CLEARANCE DISTANCES:
ABOVE WALLPLATE: 40mm
BELOW WALLPLATE: 100mm
LEFT/RIGHT OF WALLPLATE: 10mm
b. Flush switchbox Fixing
holes are spaced to suit
BS4662 requirements
c. Surface mounting with
surface wiring in
mini trunking
a. Surface mounting
concealed wiring
Wiring
A switch, having contact separation of at least 3mm in all poles
(formerly Class ‘A’), must be incorporated in the fixed wiring as
a means of disconnecting the supply.
The unit is a Class II (double insulated) device. An earth
terminal is provided for external earth continuity.
The system must be appropriately fused. A fuse rated at no
more than 3 Amps should be installed.
The unit has 4 knockouts for surface wiring, care must be taken
to ensure that the cable or mini-trunking completely fills the
knockout hole without leaving any gaps.
ALL WIRING MUST BE IN ACCORDANCE WITH I.E.E.
REGULATIONS. THIS UNIT IS FOR FIXED WIRING ONLY.
Replacing Other Manufacturers’ Time Controls
This Programmer will mount directly onto many existing
manufacturers’ back-plates, without the need for re-wiring.
However, it is also supplied complete with a wiring
back-plate, should this not be the case.
Wiring Connections for EHE0200160 Programmer
Internal Wiring Notes
1. The Programmer is a Class II (double insulated) device. An earth parking
terminal is provided for earth wiring continuity, if required.
2. In the SUNDIAL S, W, and Y Plan wiring diagrams, connections are shown to
basic boilers only. For wiring connections to Pump over-run boilers refer to
Boiler manufacturers’ instructions.
3.
The Programmer is not suitable for basic gravity hot water control, unless using
a C-Plan, because it incorporates independent heating and hot water switching.
Final Assembly
Clip the unit onto the hinges on the top of the wallplate and
hinge down into position. Tighten the two securing screws
using a screwdriver.
Switch on the power – the Programmer will now be operating
according to the built-in programme. Refer to “USER GUIDE”
for programming details.
If the display remains blank press the RESET button, located
under the controls cover, with a blunt instrument (e.g. Pencil)
Y-Plan
C-Plan
S-Plan
W-Plan
ROOM STAT
2 3 1
CYL. STAT
2 1
C
MID-POSITION VALVE
BLUE
G/YELLOW
WHITE
GREY
ORANGE
3 AMPS
MAX
L
N
230V~
50...60Hz
BOILER
PUMP
E N L
L
N
E
EHE0200160
*NOTE 1
N
L 1 2 3 4
1 2 3 4 5 6 7 8 9 10
ROOM STAT
2 3 1
CYL. STAT
2 1
C
2 PORT ZONE VALVE
HEATING
BLUE
G/YELLOW
BROWN
ORANGE
GREY
2 PORT ZONE VALVE
HOT WATER
BLUE
G/YELLOW
BROWN
ORANGE
GREY
3 AMPS
MAX
L
N
230V~
50...60Hz
BOILER
PUMP
E N L
L
N
E
EHE0200160
*NOTE 1
12345678910
N
L1234
2 PORT ZONE VALVE
BLUE
G/YELLOW
BROWN
WHITE
ORANGE
GREY
3 AMPS
MAX
L
N
230V~
50...60Hz
BOILER
PUMP
E N L
L
N
E
EHE0200160
*NOTE 1
CYL. STAT
2 1
C
N
L 1 2 3 4
ROOM STAT
2 3 1
1 2 3 4 5 6 7 8 9 10
ROOM STAT
2 3 1
DIVERTING VALVE
G/YELLOW
BROWN
BLUE
CYL. STAT
2 1
C
3 AMPS
MAX
L
N
230V~
50...60Hz
BOILER
PUMP
E N L
L
N
E
EHE0200160
*NOTE 1
N
L 1 2 3 4
1 2 3 4 5 6 7 8 9 10
Clock
N L 1 2 3 4
3 AMPS MAX
HW OFF HW ON
CH OFF CH ON
N
L
OFF ON OFF ON
230V~
50...60Hz
EHE0200160
Timed Outputs
Whilst every care has been taken to ensure that the information included in this document
was accurate at the time of printing, we reserve the right to change specifications at any time.
The photographs reproduced in this publication are within the constraints of the printing
process and are NOT to be used for matching purposes. E&OE.
For further information telephone 0870 8506538
Ref:4277

Popular Control Panel manuals by other brands

HEIDENHAIN ND 1200 - V2.16 operating instructions

HEIDENHAIN

HEIDENHAIN ND 1200 - V2.16 operating instructions

Protege LCD User Station user manual

Protege

Protege LCD User Station user manual

Satel CA-10 Quick user guide

Satel

Satel CA-10 Quick user guide

Biamp TEC-X 1000 Installation & operation guide

Biamp

Biamp TEC-X 1000 Installation & operation guide

Satel PERFECTA-IP-32 Installer manual

Satel

Satel PERFECTA-IP-32 Installer manual

Bosch FPA-5000 System Information

Bosch

Bosch FPA-5000 System Information

ZKTeco InBio160 user manual

ZKTeco

ZKTeco InBio160 user manual

Cooper Security M2000 user guide

Cooper Security

Cooper Security M2000 user guide

Snow Switch LCD-7A quick start guide

Snow Switch

Snow Switch LCD-7A quick start guide

Bosch FPA-5000 System information guide

Bosch

Bosch FPA-5000 System information guide

Junkers TR 100 instruction manual

Junkers

Junkers TR 100 instruction manual

Honeywell nfs2-3030 Operation manual

Honeywell

Honeywell nfs2-3030 Operation manual

INIM Electronics PREVIDIA MAX System guide

INIM Electronics

INIM Electronics PREVIDIA MAX System guide

NAPCO MAGNUM ALERT RP1008 KEYPAD manual

NAPCO

NAPCO MAGNUM ALERT RP1008 KEYPAD manual

TIFATECH HTCLG instruction manual

TIFATECH

TIFATECH HTCLG instruction manual

System Sensor PDRP-2001E instruction manual

System Sensor

System Sensor PDRP-2001E instruction manual

Winmate W05FA3S-ELT1 quick start guide

Winmate

Winmate W05FA3S-ELT1 quick start guide

WAREMA Climatronic 3 Series Operation

WAREMA

WAREMA Climatronic 3 Series Operation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.