Centeron CGW Series User manual

Gateway
Instruction Manual
Model: CGW Series
Document: 040214B0001
Revision: C
Dated: 28 January 2015
Notice
The information contained in this document is current as of the date of publication
but is subject to change without notice. The manufacturer makes no warranty,
expressed or implied, with regard to this material, including but not limited to
the implied warranties of merchantability and fitness for a particular purpose.
The manufacturer shall not be liable for errors contained herein or for incidental or
consequential damages in connection with the furnishing, performance, or use of
this material.
The manufacturer assumes no responsibility for the use or reliability of its products
or equipment other than that for which it is intended or for use other than in the
manner prescribed herein.
This document is protected by copyright. All rights reserved. No part of this
document may be reproduced, copied, photographed, electronically scanned, or
translated into another language without the prior written consent of the
manufacturer.
Other manufacturer or service names mentioned in this publication are trademarks,
service marks, or registered trademarks of their respective holders.
All Rights Reserved.

Gateway Instruction Manual
Page 3
Table of Contents
1Introduction 4
2Product Overview 4
2.1Description 4
2.2Operation 4
2.3Environmental Specifications 4
2.4Certifications 5
3Installation 5
3.1Gateway-Monitor RF Site Guidelines 5
3.2Gateway Site Guidelines 6
3.3Antenna Mounting 6
3.4Wiring 7
3.4.1Supply Power 7
3.4.2Backup Battery (Optional) 8
3.5Setup 9
3.5.1Cellular Gateway Setup 9
3.5.2Ethernet Gateway Setup 9
3.6Activation 9
4Service and Technical Support 10
5Appendix A – Advanced Setup 11
5.1Admin Console Setup 11
5.2Gateway Admin Console Application 11
5.3Setting Up a Static IP Address 13
5.4Activating the Cellular Modem 14
Gateway Instruction Manual
Page 4
1 Introduction
This manual describes how to install, test and service a Gateway. The Gateway is
part of the Level Monitoring System, which includes the Gateway, up to 40 Level
Monitors (hereafter referred to as Monitors), and a Data Center that provides the
user interface.
This manual does not include how to install, test, maintain, or troubleshoot the
Monitors. Refer to the individual Monitor Instruction Manuals for this information.
The Outdoor Gateway is to be installed as fixed, permanently connected
equipment. This means that the Gateway should be fastened to a support and
electrically connected to its supply by a permanent connection.
2 Product Overview
2.1 Description
The Gateway consists of a transceiver that collects Monitor information and either a
cellular modem or Ethernet port that relays this information to a centralized data
collector.
2.2 Operation
The Gateway can receive Radio Frequency (RF) signals from up to forty Monitors.
The Gateway communicates with the Data Center using a cellular or Ethernet
connection. The Gateway sends data and can receive commands, setup
information, and firmware upgrades from the Data Center.
The Level Monitoring System utilizes 2.4 GHz ISM band communications in
accordance with the Federal Communications Commission (FCC) rules.
The Gateway is powered by a DC supply, depending on the model ordered. A
terminal block or spade terminal (depending on model) inside the Cellular Gateway
housing is provided for connecting to the power source.
2.3 Environmental Specifications
The following environmental specifications should be observed when installing the
Gateway:
Ambient Temperature Range:
oOutdoor Models: -30C to +60°C
oIndoor Models: 0C to +60°C
CGW-0 Models designed for outdoor use (Raintight) provided that the
conduit connections are made in a way that maintains this level of
protection.
CGW-1 Models designed for indoor use only.

Gateway Instruction Manual
Page 5
2.4 Certifications
This equipment contains a radio module and a cellular modem that comply with
Part 15 of the FCC Rules.
3 Installation
3.1 Gateway-Monitor RF Site Guidelines
The Gateway should be mounted in accordance with Section 3.2 and the location
should be selected in accordance with the following guidelines:
Direct line of sight between the Monitor and the Gateway will provide
optimum radio reception. Optimal orientation would have the Gateway
antenna oriented towards as many of the installed Monitors as possible.
The Monitors would ideally be oriented so that the label with the serial
number faces the Gateway.
The Monitor and the Gateway can communicate at distances up to one
mile under optimum line-of-sight conditions.
When obstructions such as walls, buildings, chain link fences, and vehicles
exist between the Monitor and the Gateway the distance between these
units should be limited to less than 500 feet.
Multiple obstructions (such as two or more walls or a tank and a wall)
should be avoided, if possible.
Electrically conductive objects, such as metal buildings, concrete
reinforcing rods, tanks, silos, and vehicles reflect radio signals. This
reflection can be either an advantage or a disadvantage to good radio
reception at a particular installation site:
1 Metal objects between the Monitor and the Gateway may reflect and
scatter RF energy and reduce radio signal strength at the Gateway.
2 Metal objects behind the Monitor or Gateway may increase the radio
signal strength at the Gateway by reflecting radio signals toward the
Gateway.
Even small objects such as tank vents or toolboxes between the Monitor
and the Gateway can significantly reduce radio signal strength if they are
within a few feet of the Monitor or Gateway. These objects can reflect
radio signals and cause an RF “shadow” which may prevent radio signals
from reaching the Gateway.
Objects which are not electrically conductive such as wooden or fiberglass
buildings, non-reinforced masonry, trees, plastic, and glass have less
effect on radio signals than metal objects.
Windows and wooden doors can provide radio signals access to otherwise
closed metal buildings. However, “low-E” window glass may have a thin
metallic coating that can reflect radio signals.
Gateway Instruction Manual
Page 6
Strong electromagnetic fields such as those found in close proximity to
power lines, large electric motors, generators, electric fences and
transmitter antennas may interfere with the radio signal received by the
Gateway.
The Gateway should be mounted as high as is reasonably possible to
improve its ability to receive radio signals. For example, placing the
Gateway high on a wall would be preferable to mounting at a low level.
Installing the Gateway in an underground basement should be avoided.
Mounting the Gateway so that it has an unobstructed view of the horizon
will improve cellular communication.
3.2 Gateway Site Guidelines
Outdoor models of the Gateway are housed in a polymer enclosure designed for
mounting on a vertical surface. The enclosure is provided with four (4) small
mounting brackets. It is intended that the Gateway be mounted with the wire
entrance on the bottom.
Indoor models of the Gateway can be mounted either on a horizontal or vertical
surface.
Reference Installation Drawing at the end of this manual.
3.3 Antenna Mounting
The Gateway is supplied with an external mount antenna. Mounting the antenna in
the vertical position provides the best RF performance.
With the antenna in the “L” position and already in the vertical position shown
below, hand tighten the SMA connector of the antenna onto the gold connector
protruding from the enclosure until snug. Do not use a wrench or pliers on the
antenna connector or the interior hex head.
Gold Connector Outdoor Gateway Position Indoor Gateway Position

Gateway Instruction Manual
Page 7
3.4 Wiring
Access the Gateway wiring connections by opening the cover.
A readily accessible disconnect device shall be incorporated in the supply wiring.
3.4.1 Supply Power
The outdoor models of the Gateway enclosure are supplied with two holes for 3/4”
conduit in the bottom of the enclosure. The installer must use the proper fittings to
maintain the weatherproof integrity of the enclosure. The manufacturer does not
recommend adding additional holes to the enclosure. However, if additional
holes are added, proper Type 4 seals must be used to prevent water from
leaking into the enclosure.
The indoor models of the Gateway are supplied with two bushings installed for the
user to connect DC supply and the Ethernet cable (if used for your model).
The Gateway is a Category II device.
The outdoor models of the Gateway require an external SELV source of 12-24V
DC.
The indoor models of the Gateway require the use of a 12 – 24V DC supply.
The wiring must be in accordance with any national, state and/or local regulations.
This equipment is considered Class 1 which uses a protective earth ground.
Verify that the cables from the cover to the printed circuit board are properly
connected. Close the cover and secure the two latches.
Fuses F1 and F2 are permanently soldered on the PCB. They are installed only for
catastrophic failure and are not considered serviceable by an end user. The
connections for this power are located as follows:
Warning: Remove all power to the board before opening
the enclosure for service. Electric shock or
deathcouldoccur.
Avertissement: Enlevez tout le pouvoir de la planche avant
d'ouvrir la clôture pour le service. Le décharge électrique ou
la mort pourraient se produire.
Gateway Instruction Manual
Page 8
3.4.2 Backup Battery (Optional)
If you purchased a Gateway with a backup battery, the following information
applies.
The approved battery for use is an 18650 series rechargeable Li-Ion battery. These
are 3.7V cylindrical batteries with 2200mAh capacity.
The procedure for changing the battery in the field is to open the housing and pull
out the old battery and insert the new battery. Make sure that it is installed properly
(with the “+” terminal to the middle of the board. The “–“ terminal is toward the edge
of the board at the bottom).
DC power input:
12-24VDC +/- shown

Gateway Instruction Manual
Page 9
Warning: The cover must be closed, clasped, and screwed/fastened shut with the
supplied screws/fastener to prevent access to live circuits.
Avertissement: La couverture doit être fermée, fermée et serrée et a vissé/attaché
fermé avec les vis/attachefournies pour prévenir l'accès pour vivre des circuits.
3.5 Setup
Prior to applying power, the Gateway must be added to the Data Center (including
adding the Gateway and Monitor serial numbers into the database).
3.5.1 Cellular Gateway Setup
There are no extra cables for the Cell Gateway.
If your cellular modem was not factory provisioned or activated on a network then
follow the special instructions located in the appendix under Advanced Setup.
3.5.2 Ethernet Gateway Setup
Using an Ethernet cable, connect the Controller to a port on a network switch or
hub or any standard RJ-45 network jack where a computer could gain access to the
Internet. Longer Ethernet cables may be used, if necessary, but the total cable
length includingpermanent wiring inside the building should not exceed 300 feet.
The Gateway will connect only to the Data Center and no inbound port forwarding
rules should be required on the customer’s network firewall.
If the local network requires a static IP address,then follow the special instructions
located in the appendix under Advanced Setup.
3.6 Activation
Following wiring and setting up the Gateway, the unit can be activated by turning on
the supply power. When power is applied, the Gateway will enter a short test mode
and the two lights on the front of the housing will cycle from off to the color Yellow.
The Gateway will then enter an initialization phase, which may take several
minutes, during which timeData Center light will blink Yellow or Green. Once the
Gateway has communicated with the Data Center, it will enter normal operating
mode and the Data Center light will turn solid Green. The status indicator lights can
be interpreted as follows:
Caution: Risk of Explosion if battery is replaced by
an incorrect type.Dispose of used batteries
according to the instructions.
Prudence: Le Risque d'Explosion si la batterie est
remplacée par un type incorrect. Débarrassez-vous
des batteries utilisées selon les instructions.
Gateway Instruction Manual
Page 10
The Data Center light indicates Data Center communication status. The Data
Center light blinks approximately once per second any time Gateway is
powered.
Blinking Red – Network connection failure. (No network connection or
Loss of connection).
Blinking Yellow – System is connected to the network, but is waiting for a
response from network router or ISP. (Waiting for network)
Solid Yellow - System is starting up or connecting to the network. (Network
not ready)
Blinking Green – Connected to the network, but the Data Center has not
responded. (Waiting for Data Center to reply)
Solid Green – Connected to the network and talking to the Data Center.
(Normal operation)
The MONITOR light provides information about radio communication between
the Monitor and Gateway. The MONITOR light is normally “off”. It blinks only
when the Gateway is receiving radio transmissions.
Blinking Green – Data received from a valid Monitor.
Blinking Yellow – Some data was received from a valid Monitor but the
signal was weak or partially corrupt. Move the Gateway or Monitor and
retest until the Monitor light blinks green.
Blinking Red – Radio signals were received from an invalid source.
4 Service and Technical Support
If you experience trouble with this equipment, please contact your distributor.
CAUTION: The manufacturer does not support field changes or modifications to
any of the Level Monitoring System equipment unless they are specifically covered
in this manual. Any other modification to the equipment will void the manufacturer’s
warranty.
PRUDENCE: Le fabricant ne soutient des changements de terrain ou des
modifications à aucun des équipements de Système de surveillance de Niveau à
moins qu'ils ne soient spécifiquement couverts dans ce manuel. Autre modification
à l'équipement va le vide la garantie du fabricant.
Warning: This unit is to be serviced by qualified service personnel only.
Avertissement: Cette unité doit être assurée l'entretien par le personnel de service
qualifié seulement.

Gateway Instruction Manual
Page 11
5 Appendix A – Advanced Setup
5.1 Admin Console Setup
In the event that the Gateway needs further setup or is not functioning properly, the
system can be accessed through the admin console. The Gateway admin console
can be connected through a USB port to any computer running a terminal program,
i.e. HyperTerm or PuTTY. A free download of PuTTY is available at www.putty.org.
Click on the download button and follow the instructions.
Connect the USB A connector to your computer and the USB B connector to
Gateway’s J3 USB connection located next to the backup battery. The PC should
be a laptop or otherwise electrically isolated from the Gateway power source.
The Linux serial gadget driver must be installed on your computer and a patch is
needed for Windows 7 which is available at
www.centeron.net/downloads/setup.bat. If your driver installation fails when you
connect the USB from the Gateway to your computer, then download and run the
setup.bat patch.
When the Linux serial gadget driver is installed, you can open the terminal program
using the following communication settings:
Baud 115.2K, 8 Data bits, 1 Stop Bit, No Parity, Handshaking is off
The Port number is depended on the availability of portscurrently on your system.
You will see the following prompt when the Gateway is connected:
OpenWrt login:
If you do not see the above prompt, press <enter> and the log in prompt should
appear. If the prompt is still not visible, then re-check your communications settings
in the terminal application.
The login is “admin” and the password is “password”.
The admin console is a command line driven interface. All commands are typed in
and pressing <enter> executes the command.
5.2 Gateway Admin Console Application
To access the administrator console application type the following on the command
line:
gwadmin [option] [parameters]
The command line is case-sensitive and spaces separate the option and its
parameter(s). The following is the list of available options:
Gateway Instruction Manual
Page 12
Option
[case sensitive] Parameter(s) Description
help Displays this list
getalerts Get gateway alert enable mask
setalerts Mask
Enable/Disable gateway alert mask
1 Power up
2 Net Failure
4 Power Outage
Turn off alerts:
gwadmin setalerts 0
Turn on Power up and power outage:
gwadmin setalerts 5
gethosts Get the list of approved hosts IP addresses
resetconfig Restore default gateway configuration
reboot Safely reboot the gateway
getgwinfo Get information regarding this gateway unit
Example:
gwadmin getgwinfo
Serial Number: 000200002B
Manuf. time: 0x0
Hardware version: 0x2
Software version: 2.1.3
Up-time:
- Boot: 23981 seconds
- Network: 23756 seconds
GW MAC: 00:06:96:02:00:00
getnetif Get the active WAN connection (cell or enet).
getrssi Return the RSSI of the cell modem (not working)
getstat Return the System State and Status
getip Get the stored static IP address
setip IP Address Set the stored static IP address
Format: xxx.xxx.xxx.xxx
getnetmask Get the stored netmask
setnetmask Net Mask Set the stored netmask
Format: xxx.xxx.xxx.xxx
getnetrouter Get the stored router/gateway IP Address
setnetrouter IP Address Store the static IP Gateway/Router address
Format: xxx.xxx.xxx.xxx
getnetdns Get the DNS primary and alternate addresses
setnetdns Primary DNS
IP Addr
Alt DNS IP
Addr
Set the DNS primary and alternate addresses
Format: xxx.xxx.xxx.xxx
Alt DNS parameter is optional
getstaticip Get the enable/Disable the Static IP Address for
Ethernet

Gateway Instruction Manual
Page 13
Examples:
Get the current ip address:
gwadmin getip
Set the network gateway/router:
gwadmin setnetrouter 10.2.27.42
Get the gateway information:
gwadmin getgwinfo
Turn on all alerts:
gwadmin setalerts 7
5.3 Setting Up a Static IP Address
Once you have the terminal setup on your computer, you can now change the static
IP address of your Gateway. Enter the following admin console commands:
Note1: XXX.XXX.XXX.XXX represents your IP address or net mask.
Note2: all commands, options, and parameters are case-sensitive.
1. gwadmin setip XXX.XXX.XXX.XXX
2. gwadmin setnetmask XXX.XXX.XXX.XXX
3. gwadmin setnetrouter XXX.XXX.XXX.XXX
4. gwadmin setnetdns XXX.XXX.XXX.XXX XXX.XXX.XXX.XXX
5. gwadmin setstaticip 1
The following is an example and not meant to be used as a real configuration:
gwadmin setip 192.154.27.55
gwadmin setnetmask 255.255.255.0
gwadmin setnetrouter 192.154.27.1
gwadmin setnetdns 8.8.8.8 8.8.8.4.4
gwadmin setstaticip 1
Once the command sequence is entered, the Gateway will restart the network
interface with the new parameters. The new static IP connection should be
established in less than a minute and can be confirmed byobserving the Data
Center light as it transitions from red to yellow and then to flashing green as it waits
for communication from the Data Center.
To return to the default setup of using a DHCP server for assigning the IP
address,enter the following command:
gwadmin setstaticip 0
1= Enable Static IP Addressing
0=Enable DHCP IP addressing
setstaticip EnableStaticIP Enable/Disable the Static IP Address for Ethernet
1= Enable Static IP Addressing
0=Enable DHCP IP addressing
Gateway Instruction Manual
Page 14
The new DHCP connection should be established in less than a minute and can be
confirmed by observing the Data Center light as it transitions from red to yellow and
then to flashing green as it waits for communication from the Data Center.
5.4 Activating the Cellular Modem
The Gateway cellular modem can be provisioned or activated on Verizon
WirelessNetwork with the following steps:
1. Log into admin console as described in section 5.1
2. At the “root@OpenWrt:~#” prompt type otasp and press <enter> to start
the over the air activation.
3. Wait about 3 to 4 minutes for the process to complete. Do not remove
power during this time as configuration may become corrupted.
4. The Gateway will automatically reboot and the cellular modem is now
activated.
Note: Multiple activations should not harm the modem or configuration.
Popular Gateway manuals by other brands

B&B Electronics
B&B Electronics VFG9000-SERIAL quick start guide

PEMTECH
PEMTECH PT800 Series Operator's manual

RTA
RTA 460AQT-N2E Product user guide

Billion
Billion BiGuard 30 quick start guide

DEUTSCHMANN AUTOMATION
DEUTSCHMANN AUTOMATION UNIGATE CX-CANopen-(Mapping) - PROFIBUS DP instruction manual

Shenzhen Seener Wireless Technology
Shenzhen Seener Wireless Technology SW8021 datasheet