SSS Siedle Smart Gateway Training manual

SG150-0
Commissioning instruction
Smart Gateway

2
Contents
These commissioning instructions
supplement/are supplemented by:
• Product Information
SmartGatewaySG 150-0
• System Manual In-Home bus:
Video
The relevant current edition is
located in the download area on
www.siedle.com
Subject to printing errors.
We reserve modications depending
on technical improvements.
Quick overview –
Commissioning 3
Safety remarks
Observe the safety instructions! 4
Servicing 4
Product registration 4
Automatic logout 4
Overview
System overview 5
Commissioning sequence 6
Bus addresses in the
In-Home bus 7
Functions applicable
across individual lines 7
Connection of bus
and IP address 7
Example – Single line system 8
Example – Multiple line system 8
System limits 8
Preparation
Menu structure User interface 9
Information on programming 10
Programming with Bus pro-
gramming software BPS650-… 10
Manual programming,
also called “Teach-In” 10
Remarks on the Finder function 10
Direct LAN connection 11
Indirect LAN connection
with active DHCP server 11
Indirect LAN connection
with inactive DHCP server 12
Commissioning
requirements
Step-by-step through the
commissioning process 14
Register product 14
Downloading and installing the
bus programming software 14
Commissioning
Manual programming 15
Programming using the PC
and bus programming
software (BPS650-…) 16
Performing a system update 16
Change user prole / password 17
Setting the date and time 17
Check/change the
network settings 17
Setting video memory/door call 17
Video settings 17
Creating IP users 18
Deleting IP users 18
Creating IP groups 18
Storey call –
Dening IP users/IP group 18
Registering IP users 18
Programming in
the In-Home bus 18
Import In-Home bus
conguration 19
Siedle app 19
Commission the Siedle app 19
Telephony connection
Siedle Axiom 19
Set up SIP client 20
Link Siedle Axiom 20
Call number prexes 20
Mobile network connection
Sequence: Install the mobile
network connection 21
Infographic: Connecting
a Mobile Terminal to a
Smart Gateway 21
Minimum requirements for
stationary internet connection 22
Minimum requirements
for mobile terminals 22
Commission the Siedle app 22
Infographic: Mobile phone
network requirements 23
Reset or check the settings
Resetting the system 24
Restarting the Gateway 24
IP address and password reset 24
DHCP server – Changes 24
Optional commissioning
steps
Reserving bus addresses 25
Licenses 25
User licences 25
Function licences 25
Logging 26
Backing up/Restoring
the system 26
Index 27

3
Quick overview – Commissioning
Observe the safety instructions! 4
Checking, selecting and preparing the network connection 17
Fullling commissioning requirements 14
Register product 14
Downloading and installing the bus programming software 14
Programming the Gateway in the In-Home bus
and exporting the conguration 10
Login on the Gateway 16
Performing a system update 16
Change user prole / password 17
Setting the date and time 17
Check/change the network settings 17
Setting video memory/door call 17
Import In-Home bus conguration 19
Creating IP users / Creating IP groups 18
Storey call – Dening IP users/IP group 18
Registering IP users 18
Set up the mobile network connection 21
Carry out a function check 24

4
Safety remarks
Observe the safety instructions!
Read and observe the safety
instructions and content of the
following documents before using
theGateway for the rst time:
• Product information sheet
• Commissioning instructions
• System Manual In-Home
bus:Video
Explain the content of the safety
instructions and dangers inherent in
using technically complex products
to children and those requiring
assistance in a way that is easily
understandable.
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualied
electrician.
Servicing
Statutory warranty conditions apply.
If the device requires servicing,
contact your specialist dealer or elec-
trical installer.
Customer service in the Furtwangen
factory
+49 7723 63-434
Protect your property!
Lock front doors or apartment doors
during the daytime if there is nobody
home. Unlocked doors allow thieves/
burglars to gain easy access to your
property.
The Siedle app can be used from
any location as a door release.
Keep smartphones on which the
Siedle app is activated safe from
theft. Protect these devices against
unauthorized usage with a code/
password. Always use the latest
protection mechanisms available for
your smartphone.
Protect your network!
Only use up-to-date components
and terminals in the network in
line with the latest state of the art.
Regularly update the operating sys-
tems of all components and termi-
nals. Exchange obsolete components
and terminals for up-to-date models.
Use professional protective software
(antivirus, rewall, …) in all termi-
nals. Issue secure passwords. Secure
your network with the highest secu-
rity standards available in the net-
work. Protect your network against
unauthorized attack from inside and
outside.
If you are no longer using an smart-
phone with the Siedle app installed,
either temporarily or over longer
periods (repair, sale, exchange),
uninstall the app from this device.
Never hand over an smartphone
with an operable app to a third
person!
Delete the affected IP user from
the Gateway. This ensures that the
affected IP user no longer has access
to the door station.
In case of emergency:
• Pull the network cable out of the
LAN connection of the Gateway
or
• Deactivate the WLAN of the WLAN
router
• Block any existing external access
to the LAN network.
Legal notice
Photographs of individuals taken
without their knowledge may not be
published or stored in publicly acces-
sible video memory facilities.
Individuals who have been photo-
graphed without their knowledge
are entitled to request that pictures
be deleted based on the right of
persons to their own likeness. Never
store pictures of persons you do
not know in social networks or
send them by email to others/public
groups. This will infringe their per-
sonal rights.
If stored images are used as part of
private / criminal law proceedings or
in a police investigation, this requires
prior clarication with a lawyer or
the responsible police authority.
Systems with video cameras which
are operated within the European
Union and are aimed at a publicly
accessible area or part of one, and
lm and record this, are subject
to the EU General Data Protection
Regulation (EU GDPR) as of May
25, 2018. It is the sole responsibility
of the operator to operate such
systems in accordance with data
protection regulations.
Product registration
Siedle software is continuously
updated and further developed. To
ensure that you make use of all the
product benets and to obtain reg-
ular future updates, we recommend
that you register your product in the
My Siedle Service Portal:
www.siedle.com/mysiedle
Automatic logout
For security reasons, the Gateway
logs out of any session with a
logged-in user if no entry has been
made in the user interface for 10
minutes. In order to prevent the
session time from being extended
articially due to the changes to the
time settings, after every change of
time setting, an automatic system
logout takes place.

5
System overview
Simplied layout showing arrange-
ment of the Gateway, Siedle app
and the installed Siedle intercom in
the overall system.
Possible IP clients*:
• Siedle app
• Siedle Axiom
• Jung TKM-Client
(Jung Smart-Control)
*From software version 2.0.1,
the scope of functions is optionally
expandable (see page25).
Integrable networking
components:
• IP cameras (linked via e.g.
Siedle Axiom)
Overview
BVNG 650-...
Siedle intercom system
building installation
Door station
WLAN
SG150-…
Mobile phone
with installed
Siedle app for
Smart Gateway
WLAN
Internet
SG150-…
ERT
ETb
TbM
S1
S1
–
+
E1
E1
PE
PE
TaM
0000000000000
SmartGateway
SG 150-0
IP20
www.siedle.com Link
In-Home
Status
Reset
Prog.
ERT
ETb
TbM
S1
S1
–
+
E1
E1
PE
PE
TaM
0000000000000
SmartGateway
SG 150-0
IP20
www.siedle.com Link
In-Home
Status
Reset
Prog.
IP network 2
IP network 1
Mobile phone
with installed
Siedle app for
Smart Gateway
Router/Switch
Internet
Router/Switch
3G / 4G
In-Home-Bus
LAN
Jung Smart Panel

6
Overview
Commissioning sequence
Mount the Gateway, connect to the In-Home bus / IP network and switch on. See Product Information/
System Manual
Congure the Gateway. 10
Optionally: Reserve additional In-Home bus addresses. 25
Programming the In-Home bus
(manually or using the bus programming software).
10
Export the In-Home bus conguration from the bus programming software. 18
Import the In-Home bus conguration. 19
Install the software (Siedle app) on the terminals (mobile phone)
and log in at the Gateway. 19,22
Mobile network connection 21
Carry out a complete function test and hand over the documentation/les
to the customer. 24

7
Bus addresses in the In-Home bus
As a one-line bus system, the
In-Home bus is restricted to a max-
imum of 31 bus addresses (bus
users). A bus video line rectier is
required for the one-line system. If
more than 31 bus addresses (bus
users) are required, up to 15 bus
lines can be coupled with each other
in the multiple line bus system. For
each bus line, you require a dedi-
cated bus video line rectier (e.g. 2
bus lines => 62 bus addresses (bus
users) => 2 bus video line rectiers).
Irrespective of whether you have a
one or multiple line bus system, the
SmartGateway can only reserve the
free bus addresses in the bus line
in which it is operated. Bus address
reservation across different lines is
not possible.
Please note that within a bus line,
the maximum functional scope is
available which has been made
available by the relevant program-
ming mode. In cross-line operation
between 2 different bus lines, indi-
vidual functions are not available for
technical reasons.
Functions applicable across
individual lines
Door calls, selective door dialling and
switching and control functions can
also be used across individual lines.
Internal speech communication and
call forwarding between users is only
possible within a line.
Connection of bus and IP address
If you are operating the Siedle
intercom and the Gateway in the
single-line bus system, each com-
ponent of the intercom is assigned
the technically stipulated number
of bus addresses (indoor station =
1 bus address and door station = 2
bus addresses). Of a maximum of 31
bus addresses available in the bus
line, only the unassigned quantity of
bus addresses is then available for
additional use in the Gateway. As
standard, one bus address is already
assigned to the Gateway during
programming. Additionally required
bus addresses must be manually
assigned to the Gateway using the
reservation function in the Gateway.
Every bus address assigned in the
Gateway can be used for connection
of an iP user or an IP group, in order
to allow these to be directly called
individually.

8
Example – Multiple line system
Use of at least 2 but no more than
15 bus lines.
Installation example
The Siedle call station comprises
2 door stations (main and side
entrance), 2 indoor stations (storey 0
and 1), 1 Gateway and 2 bus video
line rectiers.
The Siedle intercom is supplied via
the rst bus line and the Gateway
via the second bus line. Calculation
of the additional bus addresses
which can be used in the Gateway:
1. Bus line
Components Bus
adresses
Door call station Main
entrance 2
Door call station Side
entrance 2
Internal call station 1 1
Internal call station 2 1
Sum 6
Max. number of bus
addresses per bus line 31
Additionally usable free
bus addresses 25
2. Bus line
Components Bus
adresses
Gateway 1
Max. number of bus
addresses per bus line 31
Additionally usable free
bus addresses 30
The result: A maximum of 31
bus addresses can be used in the
Gateway for the connection of
IP users or IP groups (30 free bus
addresses + 1 already assigned
bus address of the Gateway).
Example – Single line system
Use of one bus line.
Installation example
The Siedle call station comprises
2 door stations (main and side
entrance), 2 indoor stations (storey 0
and 1), 1 Gateway and 1 bus video
line rectier.
Calculation of the additional bus
addresses which can be used in the
Gateway:
1. Bus line
Components Bus
adresses
Door call station Main
entrance 2
Door call station Side
entrance 2
Internal call station 1 1
Internal call station 2 1
Gateway 1
Sum 7
Max. number of bus
addresses per bus line 31
Additionally usable free
bus addresses 24
The result: A maximum of 25
bus addresses can be used in the
SmartGateway for the connec-
tion of IP users or IP groups (24
free bus addresses + 1 already
assigned bus address of the
SmartGateway).
System limits
Gateway
Characteristics: Quantity
Maximum number of
assignable bus addresses 31
Maximum amount of
IP users per gateway
(5userlicenses for a total
of 5IPusers are included
in the scope of delivery of
the gateway). From device
version 2.0.1, SiedleAxiom
and the JUNGTKM client
no longer require user
licenses. 10
Maximum number of IP
groups –
Maximum number of IP
users per IP group 6
Cascading: IP group in IP
group 0
With an In-Home bus address, you
can:
• Selectively call 1 IP user individually
through the In-Home bus (e.g. door
station)
or
• Selectively call 1 IP group (with a
maximum of 6 IP users) individually
through the In-Home bus (e.g. door
station).
With 31 In-Home bus addresses,
you can:
• Selectively call 31 IP users individ-
ually through the In-Home bus (e.g.
door station)
or
• Selectively call 31 IP groups (with a
maximum of 6 IP users) individually
but in total no more than 10 IP users
per Gateway through the In-Home
bus (e.g. door station)
or
• In a mixed conguration with a
maximum of 10 IP users, selectively
call individual IP users or IP groups
(with a maximum of 6 IP users)
through the In-Home bus (e.g. door
station)
Overview

9
Menu structure User interface
Menu level 1 Menu level 2
Status Overview
IP users
Device information
User User prole
Change the password
Basic settings Date / time
Network
Video memory / Door call
Video
Call number prexes
In-Home bus Bus adresses
Bus users
Network user Licences
IP users
IP groups
Telephony link
Help Documentation
Commissioning software
Support
System Protocols
Safe/Restore
Update
Reset
Restarting
Log out
Preparation

10
Information on programming
In order to use the door intercom
system, at least one door call must
be programmed in the In-Home bus.
Programming is described in detail
in the system manual In-Home bus:
Video.
In addition to the basic functions,
you can program additional func-
tions using the programming soft-
ware BPS650-… . For connecting
the PC to the In-Home bus:Video,
a programming interface
PRI602-…USB and a ZBVG650-…
plug-in card are required.
The Gateway can be integrated
into the In-Home bus in 2 ways:
Programming with the bus program-
ming software (recommended) or
manual programming (Teach-In).
Programming with Bus program-
ming software BPS650-…
When integrating the Gateway in
the In-Home bus using bus program-
ming, a greater functional scope is
available at the Gateway (basic func-
tions and supplementary functions).
Manual programming, also called
“Teach-In”
When integrating the Gateway in
the In-Home bus using manual pro-
gramming, only individual functions
are available at the Gateway. When
carrying out manual programming,
you can assign only one bus address
to the SmartGateway, to allow
either an IP user or an IP group to be
selectively called. If this is not ade-
quate, you must carry out program-
ming using the bus programming
software. If you decide in favour
of manual programming, the steps
with bus programming software are
omitted.
Remarks on the Finder function
In the bus programming software
(BPS), the Finder function can be
used in order to determine the IP
address of the Gateway.
Using the Finder function, you can
locate all Gateways existing in the
network, provided these are located
in the same network as the commis-
sioning PC.
Important: A Gateway can only
locate the Finder function in the
network if the Gateway is in the
same subnet of your network (i.e.
the rst three blocks of the local IP
address must be the same – e.g.
192.168.178.xxx).
If the Gateway is not located in the
same subnet, you will need to con-
nect your commissioning PC/laptop
directly to the Gateway to be able to
carry out the conguration.
Important:
The Gateway must be operated in
the local network using a static IP
address (not DHCP operation).
Preparation

11
Direct LAN connection
Direct LAN connection between
commissioning laptop/PC and
Gateway.
LAN
SG150-...
ERT
ETb
TbM
S1
S1
–
+
E1
E1
PE
PE
TaM
0000000000000
SmartGateway
SG150-0
IP 20
www.siedle.com Link
In-Home
Status
Reset
Prog.
Conditions:
• Gateway and commissioning
laptop/PC are ready for operation.
• The network setting of the
Gateway is in the as-delivered status
(DHCP client active).
• The DHCP client is enabled on
your commissioning Laptop/PC, to
be able to request a network address
from the DHCP server (router/wire-
less LAN router/managed switch/
server).
Procedure:
1 Directly connect the commis-
sioning laptop/PC to the Gateway
using a network cable.
2 Open the web browser and enter
the IP address 169.254.1.1 of the
Gateway.
3 The Login page of the Gateway is
opened.
Important:
Your browser must accept cookies,
otherwise it will not be possible to
log in on the login page.
Accessibility of theGateway:
The IP address 169.254.1.1 can also
have been used by other device
manufacturers. This IP address
should therefore only be used with a
direct LAN connection.
Indirect LAN connection with
active DHCP server
LAN connection by an existing net-
work (router/wireless LAN router/
managed switch/server) with active
DHCP server.
LAN
Router
DHCP = ON
LAN
SG150-...
ERT
ETb
TbM
S1
S1
–
+
E1
E1
PE
PE
TaM
0000000000000
SmartGateway
SG150-0
IP20
www.siedle.com Link
In-Home
Status
Reset
Prog.
Conditions:
• Gateway and commissioning
laptop/PC are ready for operation.
• The network is active.
• Gateway and PC/Laptop are con-
nected to each other by each net-
work cable on an existing network
(router/wireless LAN router/managed
switch/server).
• The network setting of the
Gateway is in the as-delivered status
(DHCP client active).
• The DHCP client is enabled on
your commissioning Laptop/PC, to
be able to request a network address
from the DHCP server (router/wire-
less LAN router/managed switch/
server).
Remarks:
• In the delivery status, the Gateway
is delivered with an active DHCP
client and requests a network
address from the DHCP server
(router/wireless LAN router/managed
switch/server), whenever a network
connection is available.
• Otherwise, nd out the IP address
of the Gateway either using the
Siedle Finder or the bus program-
ming software, via the router/Wi-Fi
router/managed switch/server in
the area Network/Network settings
with the aid of a dedicated network
scanner.
• For regular operation, a perma-
nent static IP address is required.
This ensures that the Gateway can
always be reached under the same
IP address.
Procedure:
1 Connect the Gateway via a net-
work cable to the existing network
(router / wireless LAN router / man-
aged switch / server).
2 Connect the commissioning
laptop/PC via a network cable to
the existing network (router / wire-
less LAN router / managed switch /
server).
3 Determine the IP address of the
Gateway using one of the previously
described possibilities. Using the
Siedle Finder, the login page of the
Gateway can be opened directly via
a web browser.
4 Open the web browser and enter
the determined IP address of the
Gateway (e.g. 192.168.178.100).
5 The Login page of the Gateway is
opened.
Important:
Your browser must accept cookies,
otherwise it will not be possible to
log in on the login page.
Accessibility of theGateway:
The Gateway can be reached under
the IP address assigned by the DHCP
server (e.g.192.168.178.100).

12
Indirect LAN connection with
inactive DHCP server
LAN connection by an existing net-
work (router/wireless LAN router/
managed switch/server) with static IP
adresses (inactive DHCP server).
LAN
Router
DHCP = OFF
LAN
SG150-...
ERT
ETb
TbM
S1
S1
–
+
E1
E1
PE
PE
TaM
0000000000000
SmartGateway
SG150-0
IP20
www.siedle.com Link
In-Home
Status
Reset
Prog.
Conditions:
• Gateway and commissioning
laptop/PC are ready for operation.
• The network is active.
• The IP address range (IP address
and subnet mask) of the network
(router/wireless LAN router/managed
switch/server) must be known.For
the Gateway and your commis-
sioning laptop/PC you need a dif-
ferent IP address and subnet mask,
to be able to connect both devices
with the existing network.
• The network setting of the
Gateway is in the as-delivered status
(DHCP client active). This is necessary
for the initial direct LAN connection.
• The DHCP client is enabled on
your commissioning Laptop/PC, to
be able to request a network address
from the DHCP server (router/wire-
less LAN router/managed switch/
server).
Procedure:
Part A:
1 Directly connect the commis-
sioning laptop/PC to the Gateway
using a network cable.
2 Open the web browser and enter
the IP address 169.254.1.1 of the
Gateway.
3 The Login page of the Gateway is
opened.
4 If applicable, select a different
language.
5 Enter the user name admin.
6 Enter the relevant password
(standard: admin).
7 Click on Log in.
8 The administrator user interface of
the Gateway appears.
9 Click on Basic settings > Network.
10 The network settings are dis-
played.
11 Remove the tick under Obtain IP
address automatically by DHCP.
12 The network settings are now
highlighted in white and can be
changed.
13 Execute the changes at the net-
work settings.
14 Click on the “Apply” button.
15 You have changed the network
settings, the Gateway will restart.
Part B:
16 Connect the Gateway via a net-
work cable to the existing network
(router / wireless LAN router / man-
aged switch / server).
17 Connect the commissioning
laptop/PC via a network cable to
the existing network (router / wire-
less LAN router / managed switch /
server).
18 Change the network settings on
your commissioning laptop/PC, in
accordance with the prescribed net-
work address range (IP address and
subnet mask) an save the changings.
19 Open the web browser and enter
the static IP address of the Gateway
(e.g. 192.168.178.100).
20 The Login page of the Gateway
is opened.
Accessibility of theGateway:
The Gateway is available under the
manually assigned static IP address
(e.g. 192.168.178.100).
Remark:
For regular operation, a perma-
nent static IP address is required.
This ensures that the Gateway can
always be reached under the same
IP address.
Important:
Your browser must accept cookies,
otherwise it will not be possible to
log in on the login page.
Preparation

13
Commissioning requirements
Standard login data/
Known login data
Standard user name: admin
Standard password: admin
Required network properties Direct LAN connection between the Gateway and commissioning laptop/PC
(zero conguration networking: 169.254.1.1) or DHCP-capable network for
initial commissioning. For regular operation, a permanent static IP address
is required. This ensures that the Gateway can always be reached under the
same IP address. Otherwise, nd out the IP address of the Gateway either
using the Siedle Finder or the bus programming software, via the router/Wi-Fi
router/managed switch/server in the area Network/Network settings with the
aid of a dedicated network scanner.
Time setting • Manual time settings: If there is no facility for automatic time setting,
the time must be entered manually.
• Automatic time setting: You will require an internet connection to a time
server in the internet or the address of an internal time server in the LAN
in order to adjust this during the conguration. This data must be made
available by the customer/system administrator.
Remark: If the Automatic option has not been selected for Time/date,
then the time must be reset after each power failure or reset, as there is no
buffer battery. Alternatively, you can operate the Gateway with manual time
setting at an uninterruptible power supply.
Sufcient number of user licences For each IP user (Siedleapp, etc.) one user licence is required.
There are 5 user licences contained in the scope of supply.
Other user licences can be ordered under www.siedle.com/mysiedle.
Necessary commissioning software • Bus programming software BPS 650-0 – Version: (Latest edition)
The bus programming software can be downloaded under
www.siedle.com.
• Siedle nder (component of the bus programming software installation)
• Standard web browser (latest version)
Required documentation • Product information Smart Gateway Professional SG150-0
• Commissioning instruction
• System Manual In-Home bus: Video (Latest edition)
Required hardware • Commissioning laptop/PC
• Network cable (RJ45)
• USB cable (A->B)
• Programming interface PRI602-…USB
• Bus supply unit accessory ZBVG650-…
Local access points • Local access to the bus video line rectier and Gateway
• RJ45 connection to the DHCP-capable LAN/IP network,
which is located in the direct vicinity of the Gateway.
Necessary operating software/apps • Siedle App for use on smartphones with Android/iOS operating system.
Download: Via your terminal with access to the App Store.
Commissioning requirements

14
Fullling commissioning
requirements
In order to allow the Gateway to be
commissioned, the following work
must have been completed:
1 The door intercom system has
been correctly installed/mounted
in accordance with the In-Home
bus: Video system manual and has
been prepared with a programming
interface for programming using a
PC/laptop (does not apply when pro-
gramming manually).
2 The geographical position of all
devices and all required button
assignments/functions for the indi-
vidual devices are documented.
3 A commissioning PC/laptop with
the latest version of the BPS pro-
gramming software installed is avail-
able for commissioning.
4 Network information is available.
5 The commissioning technician has
knowledge of network technology.
6 The commissioning laptop/PC
automatically refers to its IP address
(DHCP = active).
7 The intercom has been completely
documented for the In-Home bus
and for the IP network.
8 The Gateway has been mounted,
is ready for operation, connected
to the In-Home bus and the com-
missioning laptop/PC (directly by
LAN cable or via a DHCP-capable IP
network).
9 The commissioning laptop (USB)
and the bus video line rectier (RJ45)
have been connected via the pro-
gramming interface (USB/RJ45).
10 The Gateway has been registered
with Siedle:
www.siedle.com/mysiedle
11 Any existing updates have been
saved on the commissioning laptop.
12 The bus programming software
BPS650-0 is ready for operation
and there is an active connection to
the bus video line rectier (does not
apply when programming manually).
Register product
Siedle software is continuously
updated and further developed. To
ensure that you make use of all the
product benets and to obtain reg-
ular future updates, we recommend
that you register your product in the
My Siedle Service Portal:
www.siedle.com/mysiedle
For registration, you require
the MAC address (hardware
address of the Gateway: e.g.
00:10:20:30:a1:b2). The MAC
address of the Gateway can be
found on the packaging, on the
device sticker and in the device
information of the browser-based
user interface.
Procedure:
1 Register your Gateway on the
mysiedle service portal.
2 Download existing system updates
and save these on your commis-
sioning laptop.
Downloading and installing the
bus programming software
For bus programming of the
Gateway, you will need the bus
programming software BPS650. In
order to determine the IP address
of the Gateway, you will require the
Siedle Finder. The Siedle Finder is
installed at the same time as the bus
programming software. The bus pro-
gramming software can be down-
loaded under www.siedle.com.
Procedure:
1 Download the bus programming
software completely to your com-
missioning laptop/PC.
2 Install the bus programming
software completely on your com-
missioning laptop/PC.
Step-by-step through the
commissioning process
The following commissioning steps
are described over the following
pages:
1 Register product
2 Dene the type of programming
(manual programming or program-
ming using the bus programming
software).
3 Establish the network connection
to the Gateway (directly using the
LAN cable (Zero Conguration
Networking) or indirectly using a
DHCP-capable IP network).
4 Downloading and installing the
bus programming software (Only
when programming with bus pro-
gramming software).
5 Program/congure the In-Home
bus with the bus programming soft-
ware or with manual programming.
6 Congure the Gateway
7 Install, congure and commission
the Siedle app on the terminals.
8 Complete function check
9 Hand over the complete docu-
mentation, system backups and
updates to the customer / system
administrator.
10 Instruct the customer to issue
a new and secure password which
must not be known to the person
carrying out the commissioning.
Important: Observe all safety and
warning instructions! Also observe
all other instructions in this docu-
ment.
Commissioning requirements

15
4 s
OFF
1 s
ERT
ETb
TbM
S1
S1
–
+
E1
E1
PE
PE
TaM
0000000000000
Smart Gateway
SG 150-0
IP 20
www.siedle.com Link
In-Home
Status
Reset
Prog.
3 s
ON
1 s
4 s
5The call button is now assigned
to the Gateway and the basic func-
tions of the In-Home bus are set up.
Program additional users using the
same procedure or quit the pro-
gramming mode.
3The In-Home LED at the Gateway
lights up in green (ready for oper-
ation). Press the Prog. button at
the Gateway for 3 seconds. The
In-Home LED then ashes green.
Manual programming
Procedure:
On principle, the In-Home bus can
be commissioned and programmed
by one person. However, as work
has to be executed both at the door
loudspeaker and the bus indoor
device, we recommend that commis-
sioning be carried out by two people
for larger-scale projects.
2At the door station, hold down
the light/programming button for
4seconds. A protracted acknowl-
edgement tone is then audible
which is repeated every 5seconds
as long as the programming mode
remains active.
1Switch on the programming mode.
At the BNG/BVNG650-…, press the
programming mode button briey.
The LED1 ashes in a 2-second
rhythm to indicate that the program-
ming mode is active.
4On the door station, press and
hold the desired call button for
4seconds until a sustained tone can
be heard from the door loudspeaker.
The call button is now assigned to
the bus indoor device.
• Complete the installation
• Check the switch positions at the
BNG/BVNG650-…, in new systems
set the switch setting to Norm.
• Activate the programming mode
at the bus line rectier
• Set the door station to the pro-
gramming mode
• Program the users
• Quit the programming mode
While the bus line rectier is in the
programming mode, several steps
can be programmed in sequence.
There is no need to quit the pro-
gramming mode after every oper-
ation.
Commissioning

16
Programming using the PC
and bus programming software
(BPS650-…)
Log into the Gateway using one of
the possible connections. On rst
registering at the Gateway, mes-
sages appear about licensing agree-
ments and product registration:
• To be able to use the Gateway,
conrm the licensing agreement
with OK.
• Conrm the registration prompt
with Register now, if you have not
yet registered, and complete the
product registration. If registration is
not possible at the current time, click
on Later. Click on Do not show
again if you have already registered
the product.
Procedure:
1 Start your web browser, enter
the IP address of the Gateway (e.g.
169.254.1.1 or 192.168.178.100)
and conrm your entry.
2 The Login page of the Gateway is
opened. The language of the login
page depends on the language
settings of your commissioning
laptop/PC.
3 If applicable, select a different
language.
4 Enter the user name admin if this
is not already entered
5 Enter the relevant password
(standard: admin).
6 Click on Log in.
7 Conrm the licence conditions
with OK.
8 Conrm the registration prompt
if you have already registered,
otherwise complete the product
registration.
Performing a system update
Every time before updating the
system (upgrade/downgrade), carry
out a complete system backup.
Ensure that all system backups are
safely and permanently stored.
During the update process, the
power supply must not be inter-
rupted, as otherwise the Gateway
will be damaged. During the
update, the status LED ashes.
Important: After every system
update, the option “Persistently
store protocols” is deactivated to
enable the ash memory for the
updating process. This deletes
all saved protocols. You should
therefore save all protocols to your
laptop/PC before every system
update.
The system update only affects the
Gateway and the connected hard-
ware.
Update via local update tool
Procedure:
1 To access the latest software
update, please download the update
tool from www.siedle.de/sg-150
2 Save the le with the extension
.exe to your hard drive.
3 Activate the installation process by
double-clicking and run the tool.
4 Conrm any pop-up queries about
whether you really want to run the
tool.
5 Select the network connection via
which the Gateway can be reached.
6 On the Gateway’s user interface,
activate System > Update > Use local
update URL
7 Copy the update URL shown in
the local update tool and paste it
into the Gateway user interface in
the following location: System>
Update> Use local update URL
8 Click the Set update URL button
9 Click the Start update button
10 The current system version and
the update version are shown.
11 Select whether a system backup
is available or not needed.
12 Click the Update system button.
During this update process, the
Gateway and then the connected
hardware will be updated to the
latest software version– provided a
newer version than the one already
installed is available.
Important
Do not close the tool until all update
processes for all devices have com-
pletely nished.
Update via server
If you have a continuous Internet
connection, you can also carry out
the update via the Siedle update
server.
Procedure:
1 On the Gateway’s user interface
activate the option in the following
location: System> Update> Use
Siedle update server
2 Click the Check for updates
button.
3 The current system version and the
update version are shown.
4 Select whether a system backup is
available or not needed.
5 Click the Update system button.
During this update process, the
Gateway and then the connected
hardware will be updated to the
latest software version– provided a
newer version than the one already
installed is available.
Commissioning

17
Change user prole / password
Procedure:
1 Click on User > User prole.
2 Change/Complete the input elds.
3 Conrm your input by clicking on
Apply.
4 Click on User > Change password.
5 Enter the old password (Standard:
admin).
6 Issue a new password.
7 Click on Apply in order to change
the password.
Setting the date and time
For correct local time, and winter/
summer time changeover, the rel-
evant time zone must be set. The
following values are pre-set in the
as-delivered status of the Gateway:
• German timezone (UTC+01:00)
• Automatic summer time change-
over deactivated
• Automatic time setting (NTP
server) activated
Procedure:
1 Click on Basic settings > Date /
time.
2 Select your time zone.
3 Click on automatic summer time
setting if your location changes over
between summer and winter time.
4 Select how you wish the time
setting to take place (automatically/
manually). Observe the information
on time setting in the commissioning
requirements.
5 Click on Apply to save your set-
tings/changes.
6 You are automatically logged out
of the Gateway.
Check/change the
network settings
Procedure:
1 Click on Basic settings> Network.
2 Check the network settings for
correctness. Change the IP settings
if other IP addresses are required or
necessary.
3 To create a connection with the
Internet, the Gateway requires
valid network information. If this is
entered incorrectly, no connection
can be established with the time
server in the Internet, or the Apple
Push Notication Service for the
Siedle app cannot be reached.
4 Check the settings you have car-
ried out for correctness. Click on
Apply to save any changes you have
made.
Setting video memory/door call
In the menu Basic settings> Video
memory/Door call, you can carry
out settings relating to the video
memory and door call. Both setting
ranges are visually separated by a
frame.
Procedure:
1 Click on Basic settings> Video
memory/door call.
Video memory settings:
2 Activate the automatic video
memory if you wish an image to
be taken of the person calling after
every door call.
3 Activate the manual video memory
if you wish users of the Siedle app to
be able to manually take additional
images.
4 Set the time in seconds after
which you wish an image to be
automatically taken after a door call
(standard setting: 5seconds).
5 Enable automatic deletion of
images to automatically delete
images that have exceeded the set
age (GDPR functionality).
6 For automatic deletion of images,
set the maximum age of images in
days.
Door call option settings:
7 Activate the direct door call if you
wish users to be able to call door call
stations directly.
8 Activate the camera observation if
you wish users (except for the Siedle
app) to be able to display a live pic-
ture from the respective accessible
bus/IP camera.
Existing bus cameras can be selected
directly.
IP cameras can be additionally
integrated into the Siedle IP users
(except for the Siedle App). This
requires the bus cameras for the
camera observation function to have
been activated in the Gateway (SG:
Basic settings> Video memory/door
call >Activate camera observation).
With the Siedle IP users, you can
select the bus cameras in the oper-
ating menu.
9 If you install a storey call button in
your building, this can be connected
directly to the Gateway. However,
it is only possible to select a user
(except for the Siedle App) for the
storey call once you have created an
IP user / IP group.
Video settings
The standard bus camera on the
door supports the PAL colour trans-
mission system.
If an NTSC camera is used on the
door, then the camera mode must
be changed in the Gateway’s basic
settings.
Procedure:
1 Click on Basic settings> Video.
2 Activate NTSC camera mode.
3 Click on the “Apply” button.

18
Creating IP users
One licence is required per IP user.
There are 5 user licences for IP users
contained in the scope of supply. If
you require additional user licences,
these can be ordered from Siedle
at www.siedle.com/mysiedle
and imported into the Gateway. For
subsequent login of an IP user at the
Gateway, the login data issued in the
Gateway will be required:
User name (e.g. user0001)
Password
IP address of the Gateway (e.g.
192.168.178.100)
Procedure:
1 Click on Network users > IP users.
2 Click on Create IP user.
3 Select a user type (e.g. Siedle
Axiom).
4 Complete the information.
5 Issue a password according to the
system requirements.
6 Select the In-Home bus address
for the IP user (bus address refer-
ence). As standard, the Gateway
is assigned one bus address in the
In-Home bus.
(For each IP user / group which you
wish to call separately, an additional
In-Home bus address must be
reserved via the Gateway.)
7 Click on Save.
Deleting IP users
All IP users which are registered
at the SmartGateway can only be
deleted via the browser-based user
interface of the SmartGateway so
that they are no longer displayed as
internal users. If a smartphone with
registered app is switched off, defec-
tive or removed from the reception
range of the WiFi router/local area
network, or if the app is uninstalled,
the created IP user is still displayed
as an internal user, even if it can no
longer be reached.
In the Status > IP users menu, all the
created IP users are listed with the
respective login status (idle/ofine/
busy/unknown).
The user can only be reached in Idle
login status.
Creating IP groups
If several IP users have to be called
over the same call button, you can
collate these in one IP group. To
allow the IP group to be reached via
the In-Home bus, a free In-Home
bus address must exist.
An IP Group can contain up to 6 IP
users.
Procedure:
1 Click on Network user > IP groups
2 Click on Create IP group.
3 Assign the group name.
4 Select the In-Home bus address
through which you wish this group
to be reachable (bus address refer-
ence).
5 Click on Add IP user.
6 Select the IP users for the IP group
by clicking on Add and conrming
your selection with Close.
7 Save the IP group by clicking on
Save.
Storey call – Dening IP users/
IP group
The call button for the storey call is
connected directly at the Gateway
(terminal ERT and ETb) and is there-
fore independent from the rest of
the In-Home bus. A door call via the
storey call is processed directly in the
Gateway.
A storey call can be assigned to one
or more IP users (IP group)(except
for the Siedle App). The relevant IP
users/IP groups must have already
been created.
Procedure:
1 Click on Basic settings> Video
memory/door call.
2 Under users for storey calls, select
the relevant IP users / IP group in the
drop-down menu.
3 Click on Apply to save your set-
tings/changes.
Registering IP users
To allow the IP users to be con-
nected to the Gateway, the Gateway
must be capable of being reached
over the network by the relevant
IP user.
Programming in the In-Home bus
Procedure:
1Connect the PC/laptop to the
programming interface using a USB
cable.
2 Start the programming software
BPS650-…
3Click on Connect, to establish an
active connection to the In-Home
bus.
4Click on Search in order to export
the system.
5Click on Find all and add.
6 Conrm the dialogue: Do you
also want to enter the congura-
tion of all In-Home devices? with
Yes. The In-Home bus is completely
exported. After terminating the pro-
cess, you will see a device structure
at the left-hand side of the BPS soft-
ware which contains all the devices
detected in the In-Home bus.
7 Congure all devices and the
Gateway.
8Enter easily understandable and
meaningful device designations,
as these will later appear on all
displays.
9 Click on the Gateway symbol.
10 Select all the devices (eg. door
station) that should be accessible via
the Gateway IP side.
11 Export the XML conguration
le for the Smart Gateway (BPS:
SG150/650 > Create conguration
le …) and save this (e.g. cong.xml)
on your commissioning laptop.
12 Save the BPS system congura-
tion on your PC/laptop.
13 Click on the BPS taskbar on
Write.
14 Click in the conrmation dia-
logue on Select all.
15 Click on Write conguration.
The BPS conguration is saved.
16 Disconnect from the BPS and end
the programming software.
Commissioning

19
Telephony connection
Siedle Axiom
External telephone calls (public
network telephony) are possible
with Siedle Axiom if the device is
connected to a telephone system via
the Gateway.
To do so, a telephony licence is
required. You can nd this licence at
www.siedle.com/mysiedle
The connection to the TC system
must be congured as SIP client in
the Gateway.
A Siedle Axiom can be connected via
a SIP client.
Important
From rmware version 2.0 optionally
three additional function licenses can
be purchased for the Smart Gateway
SG 150-0:Bus license for BLSHT
250-0 bus software in-house tele-
phone. This license enables the use
of the software in-house telephone
(BSHT) function in the SG 150.
• Bus licence for external device BLF
250-0. This license enables the use
of a VoIP telephone in the SG 150
(optionally with video decoupling).
• Bus licence BLT 250-0 for con-
nection to a telephone system.
Buyers of Siedle Axiom receive the
equivalent BLT 251-0 licence as a
free functional extension for their
Smart Gateway or Smart Gateway
Professional.
With the two licences BLSHT and
BLF, the Smart Gateway SG 150-0
gets the functionality of the Smart
Gateway Professional SG 650-0. The
limitation to 10 IP users remains with
the SG 150-0.
For commissioning of the addi-
tional functions, please use the
SmartGatewayProfessional
SG650-0 commissioning instruc-
tions. (www.siedle.com/sg-650).
Siedle app
The Siedle App is the software-based
solution to allow your smartphone
to be integrated as a user in the
door intercom system. You must
install and start the Siedle App on
your smartphone and log in using
the login data (QR code) assigned in
the Gateway.
For successful login, both devices
must be connected to the Internet.
Always use the latest version
of the Siedle app!
Commission the Siedle app
1 Install the Siedle App on your
Smartphone. You can obtain the
Siedle App from the App Store or
Play Store.
2 Create a new IP user (Siedle App)
in the Smart Gateway.
3 A QR code is generated on the
Smart Gateway administration inter-
face that you can use to log on to
the Siedle app of the mobile device.
4 Check whether the Internet
connection of the mobile device is
active.
5 Start the Siedle App on the mobile
device.
6 Scan the QR code from the Smart
Gateway administration interface.
7 Alternatively, you can download a
PDF document of the QR code, print
it out if necessary and scan the code
later, keeping the validity period
in mind. A new QR code must be
generated after the expiration of
the period.
8 The Siedle App is now linked to
the system.
9 Carry out a complete function test
with the Siedle app.
10 The function test must be carried
out over the local Wi-Fi connection
and over the external mobile phone
network.
Import In-Home bus
conguration
In order to allow the In-Home bus
conguration to be transferred
to the Gateway, you will require
the XML conguration le of the
Gateway (e.g. cong.xml), which
was exported with the bus program-
ming software.
Procedure:
1 In the Gateway, click on In-Home
bus > Bus users.
2 Click on Select le to select the
XML conguration le.
3 Click on Upload le to import the
conguration le into the Gateway.
4 Edit the individual bus users by
clicking on the pencil symbol and
entering the information.
5 Click on Apply to save your set-
tings/changes.

20
Set up SIP client
1 Click on Network user > Telephony
connection.
2 Click on Create connection.
3 Select the required mode (SIP
client) under Connection type.
4 Assign a name, which will later
enable unique identication and
assignment.
5 Enter the IP address of the TC
system under Address.
6 Enter the port specied by your TC
system under Port.
7 Select the value supported by the
TC system under Audio packet size.
8 Enter the name that the Gateway
uses to log in to the TC system under
TC login name.
9 Enter the password that the
Gateway uses to log in to the TC
system under TC password.
10 When logging in with SIP client,
enter the realm specied by the TC
system, if required.
11 When logging in with SIP client,
enter the user authentication speci-
ed by the TC system, if required.
12 Select the supported DTMF mode.
13 If required, dene a call number
prex.
14 Click on the “Apply” button.
Commissioning
Link Siedle Axiom
Procedure:
1 Create the Siedle Axiom in the
Gateway as an IP user.
2 Under Network users > Telephony
connection, open the SIP client
that you want to use to link Siedle
Axiom.
3 Select the relevant Siedle Axiom
under call destination.
4 Click on the “Apply” button.
5 Siedle Axiom is now connected to
the TC system.
Call number prexes
In this area, the system prex
(default: *2) for the internal
telephony between the IP subscribers
is displayed and can be changed
here. The prex for the telephone
connection is not displayed until the
telephony connection has been set
up and a prex has been assigned.
This manual suits for next models
1
Table of contents
Other SSS Siedle Gateway manuals

SSS Siedle
SSS Siedle SG 650-0 User manual

SSS Siedle
SSS Siedle SET CVSG 850-1 Guide

SSS Siedle
SSS Siedle SG 150-0 User manual

SSS Siedle
SSS Siedle Smart Gateway Professional User manual

SSS Siedle
SSS Siedle Smart Gateway Professional Training manual

SSS Siedle
SSS Siedle SG 650-0 Installation and operation manual

SSS Siedle
SSS Siedle AGW 671-0 User manual

SSS Siedle
SSS Siedle FPM 611-02 User manual

SSS Siedle
SSS Siedle SET VVSG 850-1 User manual

SSS Siedle
SSS Siedle SG 650-0 User manual