Certus Compact 2013 User manual

Kompakt 2013
USER MANUAL

TABLE OF CONTENTS
1. Application
2. Design features
4. Characteristic of existing heat-resistant steel. Expressions and commentaries
5. Model series
6. Specifications
7. Stove structure and operation
8. Marking and packing of the stove
9. Suitable application
10. Servicing
11. Current repair
12. Warranty
13. Storing
14. Carriage
15. Utilization
16. Delivery set

1. APPLICATION
2. DESIGN FEATURES
3.CHARACTERISTIC OF EXISTING HEAT-RESISTANT STEEL.
EXPRESSIONS AND COMMENTARIES
The wood-burning stove with stones section «Compact 2013» for heating of sauna's steam room and its
adjacent rooms. Also, the stove is destined for steam generation and water heating.
The stove is destined for private use in Russian sauna and renders possible to get all comfortable combinations
of temperature and humidity of air.
Heat-resistant or scaling resistance means capacity of metal to stand against corrosive attack of gases at high
temperatures (not to be confused with high-temperature strength).
Heat-resistant of steel is enhanced by chrome doping. Chrome creates an inactive film on a surface of steel,
which does not be subjected by corrosion till limiting temperature called as temperature of oxide scale formation
beginning.
Heat-resistant of steel and temperature of oxide scale formation beginning rises with increase of chrome
content.
Steel is deemed heat-resistant when it contents mass fraction of chrome 13 % and more.
Steel divides into low-alloyed, medium-alloy and highly alloyed depending on alloying elements content.
Steel is deemed highly alloyed when it contents alloying elements 10% and more.
Colloquially, popular phrase «stainless steel» is not standardized expression. Expression «corrosion resistant
steel» corresponds with this expression in modern materials science.
A key differentiator of corrosion resistant steel is chrome content 12,5% and more.
Temperature of oxide scale formation beginning of applied steel is not less 750C?, and it is confirmed by
certificates of manufacturers.
For comparison: temperature of oxide scale formation beginning of constructional or «carbon»steel is no more
than 400C?, it is greatly low than temperature of walls of functioning wood-burning stove.
Heat-resistant steel is more expensive than traditionally applied «carbon»steel. Its share in manufacturing
costs of stove corresponds near 50%. Therefore, in the process of selection chemical compositions of steel, a
manufacturer excludes those alloying elements and technical operations its processing which don't increase heat-
resistance and lead to unjustified increase in the cost.
Stereotypical perception of stainless steel as mirror surface is erroneous. Mirror surface of household stainless
steel products is achieved by special expensive removal of dark oxide film from surface of sheet. This action is not
needed under manufacture of wood-burning stoves.
ATTENTION! If using of the stove «Compact 2013» for commercial purposes and, also, continuous heating
of stove for more than 10 hours, when working load will increase six-tenfold. Period of working time of the
stove greatly is reduced at such conditions and manufacturer declines all warranties.
nDimensions of the stove permit to locate it in small steam-rooms.
nA special construction provides flash heat of a steam-room (capacity size to 12m3)with small wood
consumption.
nIncreased volume of stones section.
nRelief ports in a bottom side of the stones section prevent progress of corrosion during excessive water
feed.
nOrnamental external components are made with use of current technologies.
nIt is possible to use an integral or mounted tank for water heating or two tanks simultaneously.
nYou can choose model types of constructive or heat-proof steel.
Steel used in manufacture of stoves «Compact INOX 2013»- is heat-resistant, highly alloyed, corrosion
resistant (stainless) in accordance with above stated characteristics.

Model Compact Compact Compact Compact
2013 2013 WT INOX 2013 INOX 2013 WT
Calculated capacity size for space heating, CBM 6-12 6-12 6-12 6-12
Width, mm 415 415 415 415
Depth, mm (total) 730 830 730 830
Depth, mm (without including
length of a fuel canal) 495 595 495 595
Height, mm 705 705 705 705
Mass, kg 62 67 48 53
Mass of loaded stones, kg 35 35 35 35
Capacity size of stones section, l 19 19 19 19
Maximum capacity of fuel load, l 26,5 26,5 26,5 26,5
Maximum length of a log, mm 370 370 370 370
Diameter of attachable a flue, mm 115 115 115 115
Minimal height of a flue from fire bar, m 5 5 5 5
The manufacturer considers that buyers of stoves «Compact INOX 2013»shall only pay for those special
characteristics of steel which are needed for its using into wood-burning stoves.
Upon storage and operation of stoves in condition of higher humidity, traces of surface corrosion on non-
painted area are allowed. These traces don't influence upon operational characteristics of product.
There are 8 basic models produced in lots: «Compact 2013», «Compact INOX 2013», «Compact 2013 WT»,
«Compact INOX 2013 WT», «Compact 2013 Vitra», «Compact INOX 2013 Vitra», «Compact 2013 Vitra WT»,
«Compact INOX 2013 Vitra WT».
These models have general operating principle and capacity size of steam-room for their using.
Differences between models consist in the material of the firebox and the design of the fuel channel.
There is an integral tank for water heating in such models as «Compact 2013 WT», «Compact INOX 2013
WT», «Compact 2013 Vitra WT», «Compact INOX 2013 Vitra WT».
The stove has various color version of the convector.
The models «Compact 2013», «Compact INOX 2013» have modification with a short fuel channel.
Specifications are presented in Table 1-2. Overall sizes of stove are presented in figures 1-5. Installation
dimensions of the stove (aperture under fuel canal) are presented in clause 8.6.
There are following acceptable fuel types: fuel wood, peat briquette, woodchip briquette for enclosed-type
heaters, fuel pellets.
Recommended volume of hot-water tank of a samovar type «Baykal»is 55 — 72 l. Recommended volume of
outboard hot-water tank is 63 — 70 l.
Heat time of a vapor room from 20C?till 100C?is approximately 60 min subject to correct thermal protection.
Capacity of the integral tank is 24 L in the models with the tank. Size of a connecting thread of the fitting of
the integral tank is G1/2.
4. MODEL SERIES
5. SPECIFICATIONS
Table1. Specifications of the stove with stones section «Compact 2013».
ATTENTION! Hot-water tanks and heat exchange unit of samovar type «Kostakan»aren't included into
delivery set.
ATTENTION! Maximum capacity size for space heating is determined by terms of providing with effective
convection heat transfer and standards of overall thermal resistance of walling by SNIP (ÑÍèÏ)
(construction norms and rules) 23-02-2003

Figure 1. Overall sizes of the stove «Compact 2013».
Figure 3. Overall sizes of the stove «Compact 2013» ñshort of the fuel channel.
415
705
35
605
495
415
705
160
460
730
495
245
O115
255
415
830
595
160
460
200
Figure 2. Overall sizes of the stove «Compact 2013 WT»

Table2. Specifications of the stove with stones section «Compact 2013 Vitra».
205
535
750
495 415
705
500
395
245
O115
415
205
535
850
595
200
Model Compact CompactCompact Compact
2013 2013 INOX 2013 INOX 2013
Vitra Vitra WT Vitra Vitra WT
Calculated capacity size for space heating, CBM 6-12 6-12 6-12 6-12
Width, mm 500 500 500 500
Depth, mm (total) 750 850 750 850
Depth, mm (without including length of a fuel canal) 495 595 495 595
Height, mm 705 705 705 705
Mass, kg 62 67 48 53
Mass of loaded stones, kg 35 35 35 35
Capacity size of stones section, l 19 19 19 19
Maximum capacity of fuel load, l 26,5 26,5 26,5 26,5
Maximum length of a log, mm 370 370 370 370
Diameter of attachable a flue, mm 115 115 115 115
Minimal height of a flue from fire bar, m 5 5 5 5
Figure 4. Overall sizes of the stove Vitra»«Compact 2013
Figure 5. Overall sizes of the stove Vitra»«Compact 2013

6. STOVE STRUCTURE AND OPERATION
«Compact 2013» stove designed for operation in the intense combustion mode while temperature increasing
in the sauna room, and in the economy combustion mode to maintain the selected temperature. The stove overall
look and the main elements layout are shown in Figure 6.
«Compact 2013 INOX», «Compact INOX 2013 WT», «Compact INOX 2013 Vitra», «Compact INOX 2013 Vitra
WT» models' firebox (3) and stones section (1) made of heat-resistant high-alloy steel with a chromium content not
less than 13% with the wall thickness of 2 mm.
«Compact 2013», «Compact 2013 WT», «Compact 2013 Vitra», «Compact 2013 Vitra WT» models made of
structural steel 4 mm thick.
Stones section (1), divided into two parts, provides the best use of heated stones mass. The large mass of stones
laid into both parts of the stones section provides temperature stability in the steam room and operates like a
powerful steam generator. Through the ventilation gap the heat from the heated stones transferred into convection
flow, accelerating steam room warming. Excess water falling on poorly heated stones drained through special holes
on the front and rear walls in the deepest part of the stones section.
The cowl (6) prevents the smoke to get directly into the chimney (5). Through cowl use flue gases are not
emitted directly into the chimney but delayed, skirting it, and give more heat to the stones.
Convector casing (2) covering the stove heating surfaces accelerates air heating in the steam room forming a
strong convection flow. Besides of that, it shades hard infrared radiation emitted from the hot firebox walls, which
creates soft warmth in the steam room and serves to protect against accidental contact with the stove during its
operation.
Through the special afterburner channels secondary air is supplied into the stove flue ducts for exhaust gases
post-combustion and the stones section effective heating.
Outside-mounted fuel channel allows the stove firing in an adjacent room. Model with a short fuel channel is
for those who prefer to fire the stove in the steam room.
Firebox door, rotating hinged opens at an angle required for a comfortable and safety fuel loading.
«Compact 2013» model door manufactured in two interchangeable versions: the steel door (8) with an outer
panel self-cooling property and the door of the original design with translucent screen made of heat-resistant glass
Schott Robax ® (9).
Image products presented in this Manual may differ from the product accompanied by this
manual.
Figure 6. layout of the main elements of the stove .Modification with heat exchange unit.«Compact 2013»
31
1
2
3
4
5
6
7
1 0
8
9
Compact 2013
Compact 2013 Vitra
1. Ventilated stones section 6. Cowl
2. Convector casing 7. Cast iron stove bar
3. Firebox 8. Steel door
4. Sliding ash drawer 9. Door with translucent screen
5. Chimney (chimney flue. It is outside the scope of 10. Door with translucent screen in a panoramic fuel
supply) channel of the model Vitra

«Compact 2013 Vitra» model completed with a panoramic fuel channel and the door with translucent screen
made of heat-resistant glass Schott Robax ® with diagonal of 17cm (10). There is a gap in the upper part of the door
for pyrolysis self-cleaning of the translucent screen from soot settling.
Heat-resistant glass screen allows you to monitor combustion process and simply enjoy living fire.
The fire-bar (7) made of solid cast iron installed in the lower part of the firebox. The ash box with sliding ash
drawer is under the firebox (4).
With the stove operation, primary air required for combustion is supplied through the ajar ash drawer (4) and
bar (7) to the fuel. The bar provides combustion process acceleration and a powerful high-temperature flame at the
ignition moment. It provides a uniform wood burning which is so necessary for a sauna stove.
Ash falls into the ash box through the gaps of the bar and you can easily clean the stove without combustion
process interrupting.
Combustion gases are directed into the chimney through the flue pipe with diameter of 115 mm.
In the models with a tank under the convector, the tank for water heating of 24 liters is mounted to the firebox
rear wall.
The stove components without large thermal load are made of structural steel.
The stove outer surface is covered with a heat-resistant organosilicon enamel of KO-868 type.
On a stove there is an information code plate with details about a model of a stove, its mass, factory serial
number, production date of a stove and other technical features, and also the information on certificates for this
model.
A stove is packed in a transport pack. Maintenance manual in a packaging bag and components are enclosed in
the stove combustor.
On a pack of a stove at the front part there is a label with information about a model of a stove, its mass, design
features and production date.
ATTENTION! The manufacture reserves the right to introduce changes into the sauna stove design not
impairing its consumer properties.
1. Cut a packing tape
2. Remove cardboard boxes
3. Remove a polyethylene
4. Pull from a stove maintenance manual and components (if available) and take off a packing
5. Take away blocks and turn off fixing bolts
6. Remove advertising stickers from a surface of a protective film.
ATTENTION! Don't use the stove for industrial premises of categories A, B, V of fire and explosion safety in
accordance with NPB 105-95 (classification of premises and buildings of fire and explosion safety).
ATTENTION! Don't use matters as fuel which aren't mentioned under point 5.
ATTENTION! Expressly prohibited using black coal and coal briquettes as fuel.
7. MARKING AND PACKING OF THE STOVE
7.1. Marking
7.2. Packing
7.3 Procedure of remove the packaging by a consumer
8. SUITABLE APPLICATION
8.1. Operational constraints

ATTENTION! Don't use alcohol-containing means, benzene, kerosene and other highly inflammable
matters for ignition. Don't use a glossy paper, trimmings of wood particle boards, laminated flooring board,
orgalite because these matters would evolve noxious substances under burning, and would be cause of
outburst and damage of a stove.
ATTENTION! Don't use the stove with an empty heat exchange unit and a hot-water tank or an
unconnected system of water heating (if available).
ATTENTION! Don't use the stove inappropriately.
ATTENTION! Don't use the stove in autohouses, trailers and tents.
ATTENTION! Don't commit overheating of the stove at the time of its operation.
ATTENTION! At the time of the first heating of the stove applied on the metal industrial oils and light
volatile compounds of organ silicone enamel evolve smoke and smell, which aren't evolved in the following.
ATTENTION! Don't make mechanical action to a surface of a stove till complete cooling and final
polymerization of paint at the time of the first heating in order to avoid damage of a lacquer coating.
ATTENTION! The first heating of the model «Vitra» shall be carried out with opened door of combustor to
prevent smoked translucent screen.
nDoesn't have external damages of a carcass.
nA door freely revolves on hinges, closely adjoins to a carcass and is efficiently fixed by a lock.
nA translucent screen (if available) on a door doesn't have damages.
nFire bar is safe without burnouts and cracks.
nAn ash drawer has to freely move and it closely adjoins to a carcass in the closed position.
nIntegral tank (if available) doesn't have damages.
Overheating of the stove can be identified by red glow of the metal in the dark.
This situation can appear upon the uncontrolled air supply into the fire box. For example, when the door is
open. The stove warming up may lead to dangerous conditions of the stove operation and its premature breakdown.
Itisnecessary bringing in safety precautions for people with a lungs disease and owners of pet, who are sensitive
to smoke (such as birds).
The first heating of the stove it is necessary making open-air with fire prevention discipline, at least one hour,
with charging of a fire box in half in the regime of active combustion.
For correct operation of the stove, at the time of the first heating it is necessary to organize a temporary flue
with height at least 2m.
For the model with an integral tank, at the time of the first heating it is necessary to fill the tank with water.
Drain water after full cooling of the stove.
Please, make sure in normal functioning of the all components of the stove and protective constructions. A
faulty stove is not permitted to operation.
An efficient stove:
It is necessary to load special stones into stones section. The manufacturer recommends using gabbrodiabase,
peridotite, talcum peach, jadeite. These volcanic rocks possess a beautiful pattern and composed of durable minerals
against physical and chemical action. Also, these volcanic rocks don't contain harmful impurities. These volcanic
rocks possess considerable heating capacity, stand against large, repeated temperature differential. Also, stones are
fireproof and don't break. Irregular shape of stones and difference of its sizes provide maximum filling of stones
section and maximal area of heat output.
8.2. Commissioning of the stove
8.3. Stones for stones section

ATTENTION! Stones of unknown origin can contain, numerously, harmful sulfides and radionuclides,
which make its useless and even dangerous for using in a sauna.
nWalls (or partition) of inflammable materials have to be protected with plaster with thickness 25 mm on
an expanded metal or a metal plate on an asbestos paper with thickness 10 mm, from a floor to a level of
250 mm above the top of the stove.
nA wall (or partition), through which fuel canal pass, shall be from nonflammable materials from a floor to
a level of 250 mm above the top of the stove. Recommended thickness of a wall is 125 mm.
nA floor under the stove has to be protected by a foundation from brick at least two coating or other
nonflammable material at a distance of 380 mm from a wall of the stove.
nA floor of inflammable and combustible with difficulty materials in front of a door of a combustor has to
be protected with a metal plate with size 700? 500 mm with length its side along the stove.
nMake a fireproof partition in a passage of a flue through a ceiling.
nAt the time of installation of a flue in premises with a roof of inflammable materials a flue has to be
protected with a spark arrester of gauze with an opening with size no more 5?5 mm, also have to block
with nonflammable roofing materials a space around a chimney.
ATTENTION! A place of installation the stove and chimney will be done in accordance with SNIP (ÑÍèÏ)
(construction norms and rules) 41-01-2003 or, in accordance with technical standards of a country,
where the stove would be exploited.
ATTENTION! It is necessary to provide constant inflow of fresh air into the room where the stove is
operating. The breach of the condition may lead to unstable operation of the stove and appearance of
dangerous situations such as poisoning with carbon monoxide, fire breaking-out.
ATTENTION! All the stove assembly and stones setting into the stones section works shall be carried out
only after total cooling off of the stove.
ATTENTION! The stove is heavy. Make sure that you have the possibilities and equipment for its moving.
Stones shall be rinsed by scrub brush in flowing water before load.
Don't put stones higher than a top level of the stove, because stones will not heat-up to temperature needed
for quality steam formation.
üAttention! Exclude the possibility of excessive water supply to the non-burning hot stones. In this case the
intensive stones section walls oxidation process will take place due to the direct contact of water and metal. This
reduces the service time of the stones section and as the result of its burning-through.
üAttention! Hot steam exhaust from the stones section takes place when water is supplied to the non-burning
hot stones. Supply water carefully.
During the long use of the stove it is necessary to carry out the shift of stones not less than once per year. At
the same time the pebble gravel should be removed and destroyed stones should be replaced with the new ones.
Protect from fire constructions of premises:
It is recommended to organize a balanced system of ventilation for provision of good air change (see figure 7).
A hole for fresh air intake (9) with a section about 100 square centimeters is made in a floor as closely as
possible to the stove or under the stove.
A hole for used air exhaust (6) is made in a wall just below of a level of a ceiling as far as possible from the
stove. For more moist and cold air exhaust, a vertical box (8) is installed to a top hole. A vertical box possesses a vent
hole at a distance not more than 50 cm from a floor.
It is recommended to install adjustable latches (7) in air inlet and exhaust outlet for possibility to control air
exchange.
8.4. Preparation of premises to installation of the stove
8.5. Air change in a steam room
8.6. Stove assembly
34

ATTENTION! It is prohibited to install the stove in the places where the stove will create obstacles for
people moving during evacuation.
ATTENTION! It is necessary to carry out the installation of smoke sensors and gas detectors in the rooms
where the stove is installed.
nfor unprotected constructions of combustible and fire-resistant materials - 500 mm;
nfor constructions of non-combustible materials - 380 mm;
nfor constructions of combustible and fire-resistant materials protected in accordance with clause 7.2 -
380 mm;
nfor «Compact 2013» and «Compact 2013 WT» models — 480? 270 mm
nfor «Compact 2013 Vitra» and «Compact 2013 Vitra WT» models — 545? 410 mm
Mount the stove to the specially prepared place. Make sure that the stove is assembled and installed correctly.
Provided after reading this manual you still have any doubts concerning the stove correct installation you
should consult the stove assembly specialist who is aware of all the aspects of safe and correct installation of stoves.
A scheme of installation of the stove is presented in figure 7. Distance from the door of the combustor till the
wall opposite will be at least 1250 mm. Distance between the top of the stove and an unguarded ceiling will be at
least 1200 mm.
The distance between the stove external surface, flue and wall should be at least:
Do not install the stove into the niche in a wall or into the fire place.
Distance from the side of a fuel canal till a wall shall be at least 30 mm. If thickness of a wall is 125 mm then a
door of a combustor will have the most correct position.
Wall opening for fuel channel from the level of support feet shall have the following dimensions (height ?
width):
Figure 7. Installation of the stove in inflammable material premise
a metal plate on a heat-insulation material (an
asbestos paper with thickness 10 mm)
wood (inflammable material)
a thermal insulation of a nonflammable material
(haydite/dross/ basalt wool)
bricks and so on (a nonflammable material)
a material of foundation (nonflammable)
1. A sheet in front of a combustor
2. An umbrella
3. Flue with a thermal insulation of type “sandwich
construction”
4. An overlap of a nonflammable material for a roof
5. A roof splicing
6. A hole for used air exhaust
7. Adjustable latches
8. A vertical box
9. A hole for fresh air intake
Âèä À
495
380 500
1
380
30 min
9
À
6
8
7
3
2
500 min
1200 min705
4
5
1000 min
130
130

For installation of the model «Vitra»on the site of operation it is necessary:
For the models «Compact 2013» and «Compact 2013 WT», the stove
is installed on the site and then a door put on a fuel canal. A door is
included in a delivery set.
Installation of a door on the models «Compact 2013» and «Compact
2013 WT»:
The stones shall be set into the stones section after the end of the stove mounting and its connection to all the
necessary systems.
During the use of the stove, the stove pipe shall be treated very carefully.
Stove pipe (chimney stack) – is the means of air ventilation of exhausted gases, it provides the draught that
facilitates the constant air intake into the heating equipment necessary for normal burning process. The stove is
designed only for operation with natural draught.
The stove shall have its own stove pipe.
The stove pipe has two functions for the stove trouble-free operation. The first – is the piping of exhaust gases
generating during the fuel combustion. The second – is draught for air intake into the fire chamber for combustion
maintenance.
Draught – is the natural air or gases movement through the stove pipe. It generates due to the feature of warm
air to go upwards.
As far as the warm air moves in the stove pipe the low pressure is generated in the place of the stove
connection to the stove pipe. The greater pressure from the outside of the stove makes the air move into the area of
lower pressure – into the area of fire box. Thus the air intake into the fire chamber happens. This constant air inflow
1. Unscrew self-tappers 8 ps. that fixes a door with a frame to a fuel
canal and remove a door; (see Figure 8)
2. Install the stove on the site of operation (edge of a fuel canal shall
emerge from another side of a baffle);
3. Install back a door with a frame. I will be fixed by self-tappers
1. Remove a stop quick-detachable collar, then remove the axis out of the door, see figure 9.a;
2. Install the door on sleeves of a fuel canal and unite holes;
3. Set an axis from bottom to top through holes. Place a groove under a collar in the top part of an axis, see
figure 9.b;
4. Install a stop quick-detachable collar in a groove on an axis, see figure 9.c.
ATTENTION! It is prohibited to connect the stove to any air ducts except for the cases when the air duct is
designed only for operation as the stove pipe.
ATTENTION! It is prohibited to connect the stove to the stove pipe that is connected to another equipment
or heating unit.
ATTENTION! The stove does not draw. The draught is made only with the stove pipe.
8.7. Stove pipe assembly
Figure 8. Door
disassembling under
installation of the stove
«Vitra»
I
I
a)b)c)
Figure 9. Assembly of the door under installation of the stove.

is the draught.
The stove won't be operating effectively if there is no draught of the definite value.
Provided the excessive draught the considerable air flow will be entering the fire chamber and this will lead to
the stove overheating. Fire hazard may appear.
With the insufficient draught the insufficient amount of air for fuel proper and complete combustion will be
entering the fire chamber and this may lead to smoke generation in the room. The creosote generation increases
upon the formation of excessive smoke in the stove pipe and that may ignite creating the fire hazard in a house.
Creosote (from French créosote) — is colourless (sometimes yellowish or yellow-green), inflammable, hardly
soluble in water oily liquid with strong smell and pungent taste extracted from wood and coal tar. This is the
mixture of phenols mainly guaiacol and cresols. Soluble in alcohol and ether. Poisonous.
Creosote will inevitably be generated in your stove and stove pipe. To reduce the speed of its generating it is
necessary to:
Use only dried billets that were dried during the period for not less than one year.
Use hardwood of broadleaf woods that is more compact (more heavy) and combust with the higher
temperature.
Before the use of the stove check and amend all that can influence the draught. Reducing or increasing of
draught may influence the draught by set of different factors, some of them may change in the course of time.
Factors influencing the draught:
Atmospheric pressure – may act from outside of a room, from inside and from both side by turns. Weather
conditions to which the high pressure conforms (clear and cold days) usually create the perfect conditions for
combustion.
Negative pressure outside the heated room – is created with the help of ventilation facilities such as:
ventilation inside the bath room, draft hood, equipment for clothes drying, boilers with forced draught. Upon the
negative pressure the air flow in the stove pipe will go backwards at that «negative draught» or «backdraught» is
created.
Negative pressure can be neutralized by opening the door or window in the room with the stove.
The stove pipe temperature – the draught in the warmed up stove pipe is better than in the cold one. The cold
stove pipe quickly cools off hot gases going upwards and this will prevent their further going upwards. Combustion
of the first fuel charge will be enough for the stove pipe warming.
Stone stove pipes and stove pipes with section larger than the heating device are warmed up for a considerably
longer period of time.
The chimney stack shall have minimal number of elbows. The straight pipe is preferable. The use of more than
two piping may lead to the draught loss and possible smoke generation.
The manufacturer recommends to use modular thin-walled chimney stacks made of high-alloy, corrosion-
resisting steel of «Termofor» trademark with the diameter of 115 mm. They are effective, durable and required thee
minimum expenses for assembling and during operating.
For reliable fastening of the units together it is necessary to use «collar-strainer»; the use of self-drilling screws
is allowed if necessary.
In case of installation of thick-walled metal, ceramic, asbestos-cement or other chimney stack of greater weight
it is necessary to unload the stove from its weight.
The ideal solution for chimney stack – is the installation of ready-made pipe units with heat insulation of
The optimal draught for operation of stoves of «Termofor» trademark equals to 12±2 Pa.
ATTENTION! The manufacturer shall not be responsible for the influence of external factors on the
reduction of natural draught in the stove pipe.
ATTENTION! It is prohibited to use chimney stacks with galvanic coating.
ATTENTION! Do not use pipes from different manufacturers in the stove pipe.
ATTENTION! To avoid the smoke blowing into the heated room all the places of chimney stack units
connection against each other and the stove it is necessary to compact with high-temperature sealant (not
less than 1000°Ñ) providing the air-tightness of the pipe junctions.
ATTENTION! The junction of stove pipe units in overlaps and fire block is prohibited.
ATTENTION! The section of chimney stack located in the zone of sub-zero temperatures shall be obligatory
heat insulated by non-combustible material, withstanding temperatures not less than +400 °Ñ.
37

«sandwich» type of «Termofor» trademark.
In case of connection of the stove to fixed built-in stove pipe or in other cases it is not recommended to deflect
the axis of chimney stack from the vertical line for more than 45°.
In case of fire in the stove pipe it is necessary to have a clear scheme of actions that shall be elaborated by
consulting the specialist. After the fire in the stove pipe will die down, the stove pipe shall be cleaned and checked
for the destructions. Make sure that there are no flammables around the stove pipe.
The stoves with heat exchanger allow the hot water tank placing outside the steam room and set it in the wash
room. «Compact 2013» stoves provide for the use of a heat exchanger of «samovar» type, which is installed on the
chimney outlet. The water thus heated by the exhaust hot gases directed into the chimney, as in the case of
«samovar» type tank.
Exchanger of «samovar» type can be rotated in any direction with its nozzle. Heat exchangers are made of heat-
resistant high-alloy steel with a chromium content not less than 13%.
«Termofor» company recommends using of samovar type heat exchanger «Kostakan» by «Termofor» brand
with «Compact 2013» stove.
The general scheme of water heating system mounting with a heat exchanger of «samovar» type is shown in
Figure 10. Components of water heating system are not supplied.
A water heating system consists of:
At the time of installation of a water heating system, a bottom of an outboard tank for hot water shall be over
of a level of a top fitting adapter of a heat transfer device no less than 30 cm.
ATTENTION! Bath stove and chimney stack assembly shall be carried out by qualified workers from the
specialized construction and installation company in compliance with the requirements of SNIP 41-01-
2003 (construction codes and regulations) or in compliance with technical norms of the country where the
stove will be used.
ATTENTION! It is strictly prohibited to make dismountable the connections of the stove with the stove pipe
or other structural elements of the room.
ATTENTION! In case of fire in the stove pipe shut the dampers of air supply into the fire chamber, leave the
room and immediately call the firemen.
ATTENTION! Don't connect a heating system to a heat exchange unit.
nA heat exchange unit (2) with two fitting adapter;
nConnective pipes (pipeline) (8);
nAn outboard tank (5) for hot water with two fitting adapters for connecting to a heat transfer system and
one fitting adapter for installation of a tap of hot water distribution;
nA tap for hot water (6), a threeway tap (7) and a tap for water drain from a system (9).
ATTENTION! At the time of pipelines installation, don’t permit its sagging in horizontal segments. It is
recommended to install these pipelines at an angle of up no less than 30°.
ATTENTION! Don't use pipes with work temperature of operation less than +95°C for a water heating
system.
ATTENTION! Don't use connecting elements of a pipe fitting with nominal width less than nominal width
of fitting adapter of a heat exchange unit.
ATTENTION! It is prohibited to exceed the operating pressure in the water heating system for more than
0.05 MPA (0,5 kgs/cm?) during the use of «Compact 2013» bath stove with the heat exchange unit.
8.8. Stoves with heat exchange unit
8.9. Installation of a water heating system

ATTENTION! Pressure test of the system by higher pressure shall be carried out when the heat exchange
unit is switched off.
ATTENTION! Only clear water shall be filled to a water heating system. It shall meet requirements of
quality in the context of salt, iron, lime content and other.
ATTENTION! Hot water tank is the unit of extra high hazard that is why it is necessary to exercise caution
while being near it.
ATTENTION! «Termofor» company is not responsible for improper fastening of the tank.
ATTENTION! Avoid corrosive substances entering the hot water tank and water heating system.
ATTENTION! It is prohibited to pour water into the empty tank and (or) fill in empty water heating system
(if any) after stove starting up until the full cooling off of the stove and the tank.
ATTENTION! To avoid injuries and burns it is necessary to provide maximum reliable fastening of the tank
to the wall.
ATTENTION! The wall at which the remote tank is installed shall support the weight of the tank fully filled
in with water.
ATTENTION! It is prohibited to misuse the tank.
If necessary to get hot water at a short time then it will be permitted to make water distribution before its entry
to a tank. For this purpose, it is necessary to connect a threeway tap (7) to a pipe of hot line between a top fitting
adapter of a heat transfer device and a outboard tank in a convenient place for you (figures 10).
It is necessary to compact thread connections by plumbing sealant or PTFE-4 band GOST24222-80 (GOST –
national state standard).
Two types of tanks can be used for hot water with the stove «Compact 2013»: «outboard» tank and «samovar»
type.
An outboard tank is fixed on a wall of steam room or washing room in convenience place for a Consumer.
Then, it is connected to a heat transfer device through the use of pipeline (scheme of installation of a water heating
system, see point 8.9). Water in a tank is heated by its circulation through a heat-transfer.
A tank of «samovar» type is fixed on outlet branch pipe of the chimney. Water is heated by warm of outgoing
flue gases into the chimney.
When water starts to boil cold water shall be added into the tank.
Don't pour the water in tank up to the top because when water starts to boil it may spill over.
8.10. Hot water tank assembly
39
1. Chimney
2. Heat exchange unit «Kostakan»of «samovar»type
3. Stove «Compact 2013»
4. Connection with atmosphere
5. Outboard tank for hot water
6. Tap for hot water
7. Connective pipes
8. Connective pipes
9. Tap for water drain
Figure 10. Scheme of installation of a water
heating system with using the heat exchange unit
«Kostakan»of «samovar»type
7
min 30° 8
9
1
2
min 50 ìì
5
6
3
4

ATTENTION! It is prohibited to use defective tank having visual damages and (or) leakages.
ATTENTION! It is prohibited to use the tank under excessive pressure that differs from the atmospheric
one.
ATTENTION! It is prohibited to touch the warmed up to high temperatures surfaces of the tank with bare
hands or with other parts of body in order to avoid burns and damages.
ATTENTION! Before the stove firing up make sure that there is draft in the flue. Home draft testing is
performed as follows set a lighted match to the open firebox door, if the flame is pulled into the firebox
there is draft in the flue.
ATTENTION! The stove shall be used by only people, who know rules of operation to avoid personal
injuries.
ATTENTION! Don't burn the firewood in a fuel canal. It can lead to deformation of a door and smoke
spreading in a sauna.
ATTENTION! It is prohibited to stoke the stove with the open door except for the cases of re-starting up.
This may lead to appearance of dangerous modes of stove operation, smoke entering the heated room and
fire breaking-out.
ATTENTION! Don't use constrained air-feeding in the ash drawer.
ATTENTION! Don't extinguish fire with water.
The models «Compact 2013» with a tank («WT» in the name) have a built-in tank for water heating; water is
heated due to contact between the tank wall and the firebox wall and convection air flow inside the convector. Two
tanks can be used simultaneously for these stoves models.
Before regular heating of the stove, it is necessary to check the firebox and ash drawer and if it would be
necessary to clear its from ash and other items (unburned fuel, foreign objects (e.g. nails) remained from past using
of the stove.
It is necessary to lay the firewood on the fire bar through the door. At the time of heating, that to provide an
intensive ignition of a fuel and air access to a combustion zone, it is necessary to lay not tightly the firewood and a
little push the ash drawer.
Do not load the fire chamber up to the top – this may lead to a dangerous situation when the door will be
open. Always shut the door after starting the stove up.
To reduce the amount of pollutant emissions it is necessary to start the ignition from the upper part of the fuel
and during the use of the stove add firewood into the fire chamber by small portions.
Fire box shall be filled with small and medium firewood for quick achievement of high temperature in a steam
room with more economic expense of firewood (regime of temperature increase). Large-size firewood shall be put
into the bottom and smaller ones to the top. Put the kindling wood on top of the firewood.
Ash hole shall be closed and big firewood shall be loaded into the combustor for supporting of stones'
temperature and air in a steam room. Sensible quantity of firewood is 3-4 pcs.
For the emergence of a stable chimney draft after heating of the stove is needed a little time. Small smoke
emission in a premise is possible if would be opened the door of the just heated working in the regime of
temperature increasing stove. Burning of the first fuel is sufficient for flue preheat and developing of a chimney
draft which prevents fuming.
In the following, air flow, affecting the combustion rate, would be regulated with opening or closing of the ash
drawer.
For laying a regular batch of fuel, it is necessary completely close the ash drawer and to slowly open the door
after some seconds.
Be careful during the regular firewood adding to not put out the fire.
For ending of the stove's operation, please, wait till completely burning-out of a fuel, thereafter, clearing the
stove from ash and to close fully the door, the ash drawer and the gate.
8.11. Operation of the stove

ATTENTION! Little deformation of metal is possible in the combustor at the time of stove's operation. It
doesn't disturb of hermiticity of weld seams. It isn't a sign of defective products.
ATTENTION! If temperature in a premise is less than +5°C at the period of pause in the stove's work, then
water will be drained from a system of water heating.
ATTENTION! Don't leave an unattended heating stove and, also, don't trust children and people, who are
in a state of drug, alcoholic or other toxic intoxication controlling the stove.
ATTENTION! Don't touch to heated till high temperature of surfaces of the stove with hand without
defense and other exposed parts of a body to avoid burns and injuries.
ATTENTION! Don't locate a chimney, other inflammable materials on the plate in front of the combustor
or nearer of 0,5 m to the surface of the stove.
ATTENTION! To avoid an accident contact with a heat surface of the stove it is recommended to make a
barrier in the form of a netting or a fender of nonflammable material which shalln't prevent air flow near
of the stove.
ATTENTION! Don't install a closed sheathing, which would prevent free convective stream.
ATTENTION! Don't dry anyone things and objects on a partly cold surface of the stove, even.
ATTENTION! Carbon monoxide generation may be deathful.
8.12. Characteristic faults and methods of elimination
8.13. Security measures at the time of the stove operation
Before the beginning heating season the stove shall be tested. In the case of a fault, the stove shall be repaired.
A faulty stove is not permitted to operation. See signs of an efficient stove under point 8.2.
Carbon monoxide has neither smell nor colour, and is generated during the combustion of wood, coal, oil, gas
and other combustion agents. It is important to have good draught and reliable ventilation system so that
combustion products were exhausted through the stove pipe. Correctly installed stove designed so that to be
maximally safe during operation, nevertheless it is recommended to install the carbon monoxide sensors.
The sensors shall be installed at a distance from the stove to avoid false actuation. During the assembly and
service maintenance of smoke sensors it is necessary to follow the instruction provided by the manufacturer for
their assembly and location.
It is recommended to install the sensors at the level of «table» (but not close to the ceiling) to avoid false
41
Trouble type
Disturbance of a burning process
Emergence of fuming
Emergence of smell
Drops on an external surface of a
tube
Slow heating of a premise
Burnout of the fire bar and (or)
side walls
Possible cause
Chimney draft has deteriorated
Chimney draft has deteriorated
Evaporation of remains of oils and
volatile components of enamel
Insufficient impermeability of
joints of chimney
Insufficient heat insulation of a
premise
Incorrectly selected stove
Have used a fuel with high
burning temperature
Overheating of the stove
Troubleshooting
Clean the chimney
Clean the chimney
Preheat the stove in accordance
with point 8.2. in a place of
installation with maximum
ventilation of a premise
Densify joints with heat-proof
sealant
Make warmer a premise
Select a stove of higher power
Repair or replace the stove,
thereafter, use recommended fuel

actuation. Make sure that sensors actuate for the presence of carbon monoxide. In case of fire alarm (sensor
actuation):
It is strictly prohibited to change the system of air supply into the fire chamber if you want to increase the
flame. The changes of air supply into the fire chamber differing from the designed one will create dangerous
conditions for the stove use.
During the economical combustion takes place the intensive generation of tar and other organic fumes that
are mixing with exhausted steam and generated creosote. Creosote fumes condensate at relatively cold surfaces of
the stove pipe and may be accumulated there. And if afterwards they ignite this creates extreme temperatures in the
chimney stack and may lead to ignition of materials surrounding the pipe and cause fire.
Open and close the door only by the handle. Raked out ashes and drosses from the combustor shall be
extinguished with water and shall be located in a special fireproof place.
Maintenance work of the stove and the chimney shall be regularly done for most efficient and safety operation
of the stove.
Sweep chimneys and stoves (stoves) before the beginning of heating season and also during it in accordance
with the «Rules of fireproof routine in the Russian Federation» at least:
It is necessary to use the stove, out of bounds of the Russian Federation, in accordance with technical standards
of a country, where the stove would be exploited.
Involvement of experts for checking and sweeping a chimney is preferable.
The chimney can be cleaned both mechanically (with special devices, such as bristle brushes, brushes, loads,
scrapers) and chemically (with the special chemical purifier «log-sweep»). A bristle brush would be selected
depending on a form and a cross-sectional size of a tube.
nPay attention to the signs of poisoning with carbon monoxide: headache, sickness, sleepiness.
nIncrease the intensity of ventilation (open windows, doors)
nMake sure that door and ash-drawer at the stove are shut tight
nCheck – if there is smoke from the stove (through the air dampers)
nCheck the connecting pipe and stove pipe for the presence of blowing, smoke obstacle, and back-draught.
nCheck carbon monoxide sensors for false actuation.
ATTENTION! Place power lead and electrical equipment in the safety area described in the manual.
ATTENTION! Provided the creosote ignition in the stove pipe shut all air dampers of the stove, leave the
room and call the firemen.
ATTENTION! Stove for bath house (sauna) can be the reason for fire ignition.
ATTENTION! Don't perform a mechanical cleaning and servicing of the stove till its full cooling.
nOnce in three months for stoves;
nOnce in two months for continuous furnaces and fire-places;
nOnce in month for ovens and other stoves of continuous (long-term) heat.
ATTENTION! The company «Termofor» doesn't have responsibility for consequences of unqualified work
to sweeping and checking of the chimney or the stove.
ATTENTION! Take necessary measures to protect eyes and anatomical airways from a dust and soot at the
time of a mechanical cleaning of chimneys.
9. SERVICING
9.1. Servicing of the stove and the chimney

ATTENTION! Read instruction through carefully and follow recommendation of a manufacturer of
chemical purifiers. Not recommend using compositions for carbon burning-off are self-made.
1. Unscrew two nuts fixing the clamp (fig.14.I), and disassemble it and distance bushings.
2. Remove the glass from the stop.
3. Take new glass and if it doesn't have thread sealing tape stick them: tape of 20 mm in width is stuck from
the top and from below the glass, in a «Ï» shape (fig. 14.I), tape of 10 mm in width is stuck vertically,
along the lateral sides of the glass (fig. 14.II).
4. Insert the glass into the stop, at that the tape stuck from the lateral sides (vertical) shall be pressed
between the glass and the door frame (fig. 14.II).
9.2. Service maintenance of door translucent screen
10. CURRENT REPAIR
To prevent soot accumulation at the translucent screen (glass) it is necessary to clean it from time to time.
Accumulation of acidulous thin coating (of soot) will as the result erode and weaken the glass of the
translucent screen.
It is important to obey the following instructions so that the glass can be used for a long period of time.
On the regular basis inspect the glass for chips and cracks. Provided any cracks or chips are found immediately
put out the stove and address the manufacture for glass replacement issue.
Don't slam the door; don't otherwise hit the glass. When shutting the door make sure that billets and other
objects do not stick out from the fire chamber so that not to damage the glass.
Don't start up fire near the glass or in such a manner that during the burning process it may be close to the
glass.
When cleaning the glass do not use materials that can scratch or in other way damage the glass. Scratches on
the glass may during the use lead to glass destruction.
Never try to clean the glass while it is still hot. Before kindling the glass shall be completely dry.
Never put into the stove materials that can ignite explosively. Even small explosion in the closed space is
capable to smash out the glass.
Glass cleaning from sooty deposits shall be carried out as and when necessary by soft cloth wetted with special
solution for fireplace and stove glasses in accordance with the instruction.
It is prohibited to use the stove with damaged translucent screen. In case of glass damages for its replacement it
is necessary to install only high-temperature ceramic glass with thickness of 4 mm and correct dimensions. For
correct replacement order see cl. 10.
Do not use instead of the glass the heat-strengthened glass or thickened window glass. Contact the
manufacturer for the glass replacement issue.
A damage of a varnish-and-paint coating, at the time of operation, would lead to emergence of corrosion. It is
not the warranty case. The manufacturer recommends refreshing the paint of the carcass with a heat-proof
organosilicone enamel of type KO-868.
In case of translucent screen (glass) damage at the door of «Vitra» model it shall be replaced as follows (see fig.
13):
I
II
Figure 13. Repair of translucent
screen of «Vitra»model door
Door frame
Glass
Clamp
Stop
Clamp fixing
Door frame
Glass
Fastening bolt
Distance bushing
Clamp
Fastening nut
Sealing tape
of 20 mm thickness
I
Door frame
Glass
Sealing tape
of 10 mm thickness
II
Figure 14. Fastening of translucent screen of the «Vitra»model door

5. Fix the glass with the clamp and tighten the clamp with nuts
ATTENTION! Nuts fastening the clamp are screwed to the mounting bolts through the remote plugs (Figure
14.I).
1. Remove the stove from the operating site.
2. Remove the convector frame by unscrewing 4 self-driving screws (Figure 15)
3. Remove the convector by unscrewing 6 self-driving screws (Figure 16)
4. Disconnect the tank by unscrewing 2 self-driving screws (Figure 17)
5. Install the new tank, securing it in the same places.
6. Assemble the stove in thereverse order (see paragraphs 4-2).
7. Setthestoveto the operating site.
1) It has established that a defect is in 12 months from the date of transfer the Products to the Consumer;
2) It has established that a defect is due to the fault of the company «Termofor».
In case the built-in hot water tank damage while operation (cracks, leaks), it can be replaced. To replace the
tank you must:
Warranty period for the product is 12 months from the date of transfer it to the Consumer.
If the Consumer finds an inadequacy in the stated specifications (features) of the Products, the Consumer will
have the right to address his Claim to the organization (the Client) which has sold these Products.
Herewith, the Client has right to address to the Manufacturer that settle the Claim.
If an identified misstatement is satisfied the following conditions, the Manufacturer will make reworking the
Products integrally or its unit (in accordance with decision of the Manufacturer), substituting a damaged unit or its
elements, free of charge or compensating for damage by other means (with the approval of the Consumer):
Warranty doesn't apply to the Products and also its units or elements which have been changed by the
Consumer. Warranty doesn't apply to elements of the Products which shall be substituted at the time of normal
operation.
The Manufacturer doesn't give warranty to the products if the Consumer wouldn't fulfill the requirements of
the Maintenance manual.
If the Consumer (a person who has installed the product) wouldn't follow the technical requirements of
products installation and operation it leads to release of the Manufacturer from liability.
Warranties are ended from the time of determine of conditions stated above and in the future will not be
renewed.
11. WARRANTY
Figure 15. Drilling screws for
dismantling of the frame of the
convector of the stove
Figure 16. Drilling screws for
dismantling of the convector of the
stove
Figure 17. Drilling
screws for dismantling
of the tank
This manual suits for next models
7
Table of contents