Challenger SLFLF15P2 User manual

Challenger_SLFLF15P2_30P2_50P2_Instructions_Rev01
INSTALLATION INSTRUCTION
SLFLF15P2, SLFLF30P2, SLFLF50P2
Please read these instructions before installation and retain for the user maintenance engineer for future
reference
Specification:
•Operating Temperature -20°~+40°c
•IP65
IMPORTANT
•Installation must be carried out by a skilled electrician who is familiar with the appropriate
standards and technical requirements of the appliance also taking in to consideration the latest
building regulations.
•The person carrying out the installation is to check and verify that the total load on the circuit,
including the rating of the cable, fuse and or circuit breaker is not exceeded
•Ensure there is adequate ventilation around the luminaire
•Ensure the AC supply is isolated before installing or servicing
•This product must be earthed
•DO NOT look or stare at the LED fitting directly when in close proximity once illuminated
•Never modify the unit, there are no user serviceable parts inside.
Item Model Input
Voltage
Power
Factor Watt
Color
Temperature
Total Watt
Incl Driver
Output
Lumen
CRI
Dimensions
(mm)
Input
Current Weight
A SLFLF15P2
230v AC
≥0.9
15W 5000K 13.8~16.2W
1728LM
>70
148*128*45 0.18A 0.62kg
B SLFLF30P2 30W 5000K 27.6~32.4W
3900LM
>70
216*190*50 0.35A 1.23kg
C SLFLF50P2 50W 5000K 46~54W
6600LM
>70
247*238*52 0.6A 1.67kg
A
B
C

Challenger_SLFLF15P2_30P2_50P2_Instructions_Rev01
Insta ation
•Ensure the electrical AC power is OFF before and during installation
•Ensure the luminaire is securely fixed to a surface free from vibration.
•The sensor is designed for optimum performance when mounted 2.0-2.5 meters above ground
level
•For the AC supply cable and connections a cable that is rated to 90°C should be used
•The external flexible cable of this luminaire cannot be replaced; if damaged, the luminaire should
be replaced
•Keep enough length of cable to ensure adjusting the angle of the fitting is unhindered
•A suitable IP rated junction box is required for the premade AC electrical connections (Brown = Live,
Blue = Neutral and Yellow Green = Earth), this luminaire require a suitable earth
Installation Steps:
Refer to the following diagram when you install the luminaire.
1.
Directly fix the bracket to a mounting surface
SLFLF15P2
SLFLF30P2
SLFLF50P2

Challenger_SLFLF15P2_30P2_50P2_Instructions_Rev01
1. Do not remove any part of the fixture; there are no serviceable parts inside.
2. Use suitable fixing to secure the luminaire to the mounting surface.
3. Keep enough slack in the cable to ensure adjusting angle of the luminaire unhindered.
Connect the wires into a suitable IP rated connection box; B ue wire to “Neutra ”, Brown wire to “Live”,
Green/Ye ow wire to “Earth”.
4. The sensor is designed for optimum performance when mounted 2.0-2.5 meters above ground level.
5.
Any external connections need to be made in suitable IP rated enclosure, preferably with cable entry at the
bottom.
PIR Specification
Detection: 180°
Range: Max. 10m
Installation Height: 2.0-2.5m
Time: 8 ± 5 seconds to 12 ± 2minutes adjustable
Light Control: 3~1000lux adjustable
Detection Motion Speed: 0.6-1.5m s
Operating Temp: -20 ~ +40°C
PIR FUNCTION :
Day and night settings: If required for the luminaire to work in the daytime and also at night, rotate
the adjuster to the position. For night time operation only, adjust to the position, until
satisfactory operation. If fully adjusted to the position then it will only work in ambient light
less than 3LUX
SENS adjustab e: It can be adjusted according to user location. The detection distance of low
sensitivity could be 5m and high sensitivity could be 10m dependent of mounting height and angle of
the sensor flood light. The PIR is more sensitive with movement across the PIR and is less sensitive
with movement towards the PIR sensor.
Time adjustab e: The time duration can be adjusted between 5 seconds to 12 minutes. If adjusted to
the position, the time will be 5 seconds, when adjusted to the position will be 12 minutes.
MANUAL OVERRIDE FUNCTION:
1. To override the automatic mode, the sensor must be switched ON in the automatic mode. Now switch
wall the switch OFF-ON, OFF-ON powering the light twice within 2 seconds. The sensor will now hold the
light ON continuously for 5 hours.
2. To return your sensor to the automatic mode, switch your wall switch OFF, then switch ON after 10
seconds, or switch OFF-ON, OFF-ON powering the light twice.

Challenger_SLFLF15P2_30P2_50P2_Instructions_Rev01
TEST:
Turn the time adjuster to position, turn the adjuster to .
Switch on the power; the sensor will operate after Warm-up period of 35 seconds. If the sensor
receives a signal, the lamp will turn on. While there is further trigger signals the light should turn off
within 8 ± 5sec. (Note: please wait 5 seconds between successful activation during testing)
Once the testing has been completed please adjust the adjusters to the desired time and lux levels.
Maintenance
Repairs should only be carried out by a suitably qualified person.
Regular cleaning of luminaires should be carried out at regular intervals not only to ensure good optical
performance but also ensure that dirt does not accumulate to such an extent as to impair the electrical or
thermal safety of the fitting. This should be done with the luminaire switched off isolated and a soft
damp cloth should be used, do not use any chemicals or abrasives.
Light Source Maintenance: the light source of this luminaire is not replaceable; in case the light source
need to be replaced (e.g. at the end of its life), the whole luminaire shall be replaced.
Warranty:
This product is covered by an extended warranty for 5 years from date of purchase.
The extended warranty is available for installations in the UK or Ireland by a competent person in
accordance with the current building and IEE wiring regulations.
If the defective product is no longer available then Challenger may provide alternatives of similar
specification and quality.
The ambient temperatures and environment and voltage range according to manufacturer specifications
are not exceeded
The product is not exposed to any adverse mechanical stresses or impact
For full terms and conditions in regards to our extended warranty please refer to the website.
Due to our policy of continuous improvement we reserve the right to change specification without prior notice.
Errors and omissions excepted. These instructions have been carefully checked prior to publication. However, no
responsibility can be accepted by Challenger for any misinterpretation of these instructions.
CHALLENGER SECURITY PRODUCTS
10 Sandersons Way,
Blackpool, FY4 4NB
Email: enquiries@challenger.co.uk
Web: www.challenger.co.uk
This manual suits for next models
2
Table of contents
Other Challenger Spotlight manuals
Popular Spotlight manuals by other brands

Black & Decker
Black & Decker BSL301 instruction manual

Oase
Oase LunAqua 10 Halogen operating instructions

Titanium
Titanium TT-29-3000-O quick start guide

Larson Electronics
Larson Electronics GL-2110-F Instruction guide

Philips
Philips Ledino 57910/31/16 user manual

Larson Electronics
Larson Electronics LE Series instruction manual