1
REPLACEMENT OUTLET/CONVERSION KIT TO
PLUG-IN TRANSFORMER
MODEL K76-36296-1
OVERVIEW
To reduce the risk of SEVERE INJURY or DEATH:
• ANY maintenance to the operator or in the area near the
operator MUST NOT be performed until disconnecting the
electrical power (AC or solar and battery) and locking-out
the power via the operator power switch. Upon completion
of maintenance the area MUST be cleared and secured, at
that time the unit may be returned to service.
• Disconnect power at the fuse box BEFORE proceeding.
Operator MUST be properly grounded and connected in
accordance with national and local electrical codes.
NOTE: The operator should be on a separate fused line of
adequate capacity.
• ALL electrical connections MUST be made by a qualified
individual.
• DO NOT install ANY wiring or attempt to run the operator
without consulting the wiring diagram. We recommend that
you install an edge sensor BEFORE proceeding with the
control station installation.
• ALL power wiring should be on a dedicated circuit and well
protected. The location of the power disconnect should be
visible and clearly labeled.
• ALL power and control wiring MUST be run in separate
conduit.
The Replacement Outlet/Conversion Kit is ONLY compatible with
120 Vac LA500 gate operators with a standard control box. The
Replacement Outlet/Conversion Kit can replace the current
accessory outlet and/or convert to a plug-in transformer system.
The kit comes with a replacement accessory outlet and a junction
box cover. A plug-in transformer (not provided, Model APOW3) is
necessary for the conversion.
NOTE: The replacement accessory outlet may not be used.
REMOVE THE TOROID ASSEMBLY
1 Disconnect ALL POWER.
2 Open the control box cover and unplug the battery connector
from the J15 plug on the control board (Figure 1-A).
3 Cut the red and black wires going from the battery connector
to the bridge rectifier on the toroid assembly (Figure 1-B). Cap
the wires with wire nuts since they will no longer be used.
4Remove the toroid assembly from the control box by
loosening the four screws and lifting the assembly up and out
(Figure 1-C).
5Disconnect the incoming power wires from the toroid
assembly (Figure 1-D).
6 Disconnect the wires from the accessory outlet to the toroid
assembly (Figure 1-E).
7 Discard the toroid assembly.
Accessory Outlet
white
black
Power Wires
white
black
white
black
ground
ground
(back of toroid assembly)
Standard Control Box
Accessory Outlet
Toroid Assembly
Bridge Rectifier
Battery Connector
J15 Plug on
control board
(cut from
Bridge
Rectifier)
(connected
to batteries)
FIGURE 1
A
B
C
D
E
WARNING: This product can expose you to chemicals
including lead, which are known to the State of California to
cause cancer or birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov
2
INSTALL THE TRANSFORMER
The transformer can be installed inside the control box or it can
be connected to an external receptacle. Follow the instructions
according to your application.
CONTROL BOX INSTALLATION
1Run the AC power wires to the control box (if applicable).
2Connect the green wire from the accessory outlet to the
incoming earth ground rod wire using a wire nut (Figure 2-A).
3Connect the white wire from the accessory outlet to the
incoming NEUTRAL (white) power wire using a wire nut
(Figure 2-A).
4Connect the black wire from the accessory outlet to the
incoming HOT (black) power wire using a wire nut (Figure
2-A).
5Install the junction box cover (Figure 2-B). Ensure the wires
are not pinched.
6Wire the transformer (not provided) to the CHARGER input on
the control board (positive to positive and negative to
negative) (Figure 2-C).
+ -
CHARGER
BLU RED
Battery Connector
J15 Plug on
control board
Accessory Outlet
white
black
ground
white
black
ground
Power Wires
Plug-in Transformer
Model APOW3 (not
provided)
Junction Box Cover
black (-)
white (+)
(connect to transformer)
FIGURE 2
A
B
C
D
7Plug the transformer into one of the accessory outlets.
8Plug the battery connector to the J15 plug labeled BATT(-)(+)
DC(-)(+) on the control board (Figure 2-D). The control board
will power up. NOTE: You may see a small spark when
plugging the J15 plug into the board.
9Turn ON AC power to the operator.
3
Wire Distance Wire Gauge
65 feet 18
100 feet 16
165 feet 14
265 feet 12
420 feet 10
!
+ -
CHARGER
BLU RED
FIGURE 3
Longer wire runs are susceptible to surges and lightning strikes.
Control Box
Operator
Dedicated
Outlet Transformer
INSTALL THE TRANSFORMER
EXTERNAL RECEPTACLE INSTALLATION
1Run low voltage wire between the control box and the external
receptacle (Figure 3-A). The transformer must be located in a
dry location that is protected from weather conditions, such
as inside the house or garage.
2Install the junction box cover (Figure 3-B). Ensure the wires
are not pinched.
3Wire the transformer (not provided) to the CHARGER input on
the control board (positive to positive and negative to
negative) (Figure 3-C).
4Plug the transformer into the external receptacle (Figure 3-D).
5Plug the battery connector to the J15 plug labeled BATT(-)(+)
DC(-)(+) on the control board (Figure 2-E). The control board
will power up. NOTE: You may see a small spark when
plugging the J15 plug into the board.
black (-)
white (+)
(connect to
transformer)
C
A
B
Battery Connector
J15 Plug on
control board
E
D
Junction Box Cover
©2012 The Chamberlain Group, Inc.
01-36760C All Rights Reserved
www.liftmaster.com
STANDARD CONTROL BOX
WIRING DIAGRAM
LA500 WIRING DIAGRAM PLASTIC E-BOX
(TRANSFORMER RUN)
47-36589-10-D
ECN: 16363
Reference: 06-36238F
09/27/12
Attach to Outlet
Metal Chassis
With a Single Screw
SET OPEN SET CLOSE
MOVE
GATE
OFF
5
10
60
180 MIN MAX
(SECONDS)
OFF ON
OPEN CLOSE STOP
INPUT POWER
BATT CHARGING
TIMER
GATE MOVING
BATT LOW
ACC PWR OVLD
DIAGNOSTIC
CODES
STATUS:
SBC
“FIRE
DEPT.”
OPEN
EXIT
SHADOW
CLOSE
EYES/
INTERRUPT
LOCK
N.O.
COM
N.C.
+ -
+ -
ACCESSORY
POWER
ON SW.
EXP.
BOARD
XMITTER
NETWORK
PRESS &
RELEASE
TO BEGIN
SETUP
CLASS 2 SUPPLY
24VOLTS
1
LIMIT
2
- + + -
+ -
CHARGER
Photoelectric Sensors
Photoelectric Sensors
Edge
Edge
J15
Field Wiring
EXPANSION BOARD
Yellow
Blue
Black
Red
+
-
+
-
+ -
BATT
- +
DC
POWER
ID RESET ALARM
Piezo Alarm
White
White
Purple
Reset Switch
Red
Black
GROUND
BR GRN WT YE BLU RED BR GRN WT YE BLU RED
Loop Detector
Field Wiring
Wire Loop
Wire Loop
Wire Loop
Field Wiring
N.C.
Brown
Purple
Transformer 200 VA
+
-
-
-Bridge Rectier
Wire Nut
Gray
Blue
12V 7AH Battery
Black
Red
12V 7AH Battery
To J15
Primary Operator
Secondary Operator
Black
Red
Yellow
White
Red
Orange
N
GND
GND
L
N
Input Power Connection
Input Power Connection
EMI FILTER/SURGE PROTECTION BOARD
L
Switch/5A Breaker
Tranformer Run Kit (Optional)
Accessory Power
Outlets
Attach to Metal Chassis
Black
Black
Red
White
Ground
Connect Outlets
to Transformer
Kit
LOCK
N.O.
COM
N.C.
Maglock
(Optional)
(not provided)
LOCK
N.O.
COM
N.C.
Solenoid Lock
(Optional)
(not provided)
GROUND
Attach to Outlet Metal Chassis
With a Single Screw
Two 12V Solar Panels in Series
+
-
-+
Black
Red
Black
Red
Transformer
(Optional)
+
-
Blocking
Diode
Coaxial Antenna Cable
Antenna
To protect against fire and
electrocution:
• DISCONNECT power and battery
BEFORE installing or servicing
operator.
For continued protection against fire:
• Replace ONLY with fuse of same
type and rating.
(+)
(-)
(+)
(-)

Other manuals for ELITE Series

17

This manual suits for next models

1

Other Chamberlain Transformer manuals

Chamberlain LiftMaster 41C168 User manual

Chamberlain

Chamberlain LiftMaster 41C168 User manual

Chamberlain 041C0168 User manual

Chamberlain

Chamberlain 041C0168 User manual

Popular Transformer manuals by other brands

Universal ECO Series Installation instructions manual

Universal

Universal ECO Series Installation instructions manual

ferroamp Rogowski 600A installation manual

ferroamp

ferroamp Rogowski 600A installation manual

Audioplex TVC 600 installation manual

Audioplex

Audioplex TVC 600 installation manual

CHOWEL PATC--150A-EU instruction manual

CHOWEL

CHOWEL PATC--150A-EU instruction manual

DX Engineering Maxi-Core DXE-BAL450H10-BP Connection instructions

DX Engineering

DX Engineering Maxi-Core DXE-BAL450H10-BP Connection instructions

Viessmann 5200 Operation manual

Viessmann

Viessmann 5200 Operation manual

Delixi BK Series user manual

Delixi

Delixi BK Series user manual

Siemens MICROMASTER 440 GX Maintenance instructions

Siemens

Siemens MICROMASTER 440 GX Maintenance instructions

Omnitronic MCX-4250 user manual

Omnitronic

Omnitronic MCX-4250 user manual

Goobay 55400 user manual

Goobay

Goobay 55400 user manual

Bogen WMT-1A user guide

Bogen

Bogen WMT-1A user guide

Pulsar AWT845 Assembly instructions

Pulsar

Pulsar AWT845 Assembly instructions

Intermatic PX Series Installation, operation & service manual

Intermatic

Intermatic PX Series Installation, operation & service manual

Clas Ohlson SET-70M-IM quick start guide

Clas Ohlson

Clas Ohlson SET-70M-IM quick start guide

ABB VT Guard Pro Instructions for installation, use and maintenance

ABB

ABB VT Guard Pro Instructions for installation, use and maintenance

Aetechron T1000 instruction sheet

Aetechron

Aetechron T1000 instruction sheet

Tripp Lite S3MT Series owner's manual

Tripp Lite

Tripp Lite S3MT Series owner's manual

HAMPTON BAY SL-120-12A Use and care guide

HAMPTON BAY

HAMPTON BAY SL-120-12A Use and care guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.