Volume crated: 195 cu. ft.
Shipping weight crated: 1100 lbs.
Dimensions shown in inches
TABLE B - BOOSTER CONNECTION
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
Utilities
1 Electrical
AMachine connection (see Table A)
BBooster connection (see Table B)
2 Hot Water
3/4” NPT 180°F/82°C min. hot water
connection. (Machine without booster.)
3/4” NPT 140°F/60°C min. hot water
connection. (40°F/22°C rise booster)
3/4” NPT 110°F/49°C min. hot water
connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.
3 Drain
1-1/2” NPT machine connection.
Maximum flow 15 gpm.
4 Steam
A3/4” NPT machine connection.
Flow pressure 15-30 PSI. (Steam coil)
B3/4” NPT machine connection.
Flow pressure 15-30 PSI.
(Steam injector)
5 Condensate (no back pressure)
1/2” NPT machine return to boiler
6 Vents
ALoad end: 200 CFM @ 1/4” S.P.
BUnload end: 400 CFM @ 1/4” S.P.
(With blower-dryer increase room
ventilation by 600 CFM.)
64” Two Tank with Heavy Duty 36” Prewash
Rack Conveyor
Dishwashing Machine
MODEL 100 HDPW
SPECIFICATIONS
Capacity
Racks per hr. (NSF rated) 277
Wash tank (US gal.) 21
Conveyor speed (ft/min.) 7.7
Motor Horsepower
Drive 1/6
Prewash 1
Wash2
Rinse 2
Water Consumption
US Gal. per hr. (max. use) 124
US Gal. per rack .45
Heating
Tank Heat, electric (kW) 25
Tank heat, steam
(lbs/hr. required at
15 PSI flow pressure) 75
Electric booster (built-in)
(kW supplied for 40°F rise) 15
Electric booster
(kW supplied for 70°F rise) 24
Steam booster (lbs./hr.
required for 40°F rise) 120
Steam booster (lbs./hr.
required for 70°F rise) 205
Venting
Load end (minimum CFM) 200
Unload end (minimum CFM) 400
Standard 20” x 20”
rack complement
Peg 2
Flat 1
Venting Notes: Fabricated duct size:
3-7/8” x 15-7/8” (Outside dimensions)
Plumbing Notes: Because of the variation
in house-supplied steam and water pressures,
steam and water pressure regulating valves
(PRVs) may be needed. (Water PRV is standard on
machines with booster.) The PRVs can either be
purchased from Champion or obtained locally.
Warning: Plumbing and electrical
connections should be made by qualified
personnel who will observe all the applicable
plumbing, sanitary, safety codes and the
National Electrical Code.
Note: Water Hammer Arrestor (meeting ASSE-
1010 standard or equivalent) to be supplied (by
others) in common water supply line at service
connection.
40°F/22°C Rise – 15kW
Electric built-in booster (booster only)
Minimum Maximum
Supply Ckt. Overcurrent
Elec. Rated Conductor Protective
Specs. Amps Ampacity Device
208/60/3 42 50 50
240/60/3 36 45 45
480/60/3 18 25 25
575/60/3 15 20 20
70°F/39°C Rise – 24kW
Electric built-in booster (booster only)
Minimum Maximum
Supply Ckt. Overcurrent
Elec. Rated Conductor Protective
Specs. Amps Ampacity Device
208/60/3 67 80 80
240/60/3 58 70 70
480/60/3 29 35 35
575/60/3 24 30 30
Machine only
Minimum Maximum
Supply Ckt. Overcurrent
Elec. Rated Conductor Protective
Specs. Amps Ampacity Device
208/60/1 171 225 225
240/60/1 150 200 200
208/60/3 95 125 125
240/60/3 83 100 100
480/60/3 41 50 50
575/60/3 32 40 40
TABLE A - MACHINE CONNECTION
Machine and steam built-in booster
Minimum Maximum
Supply Ckt. Overcurrent
Elec. Rated Conductor Protective
Specs. Amps Ampacity Device
208/60/1 41 50 50
240/60/1 36 50 50
208/60/3 20 25 25
240/60/3 17 25 25
480/60/3 9 15 15